qemu/qemu-options.hx

4274 lines
168 KiB
Haxe
Raw Normal View History

HXCOMM Use DEFHEADING() to define headings in both help text and texi
HXCOMM Text between STEXI and ETEXI are copied to texi version and
HXCOMM discarded from C version
HXCOMM DEF(option, HAS_ARG/0, opt_enum, opt_help, arch_mask) is used to
HXCOMM construct option structures, enums and help message for specified
HXCOMM architectures.
HXCOMM HXCOMM can be used for comments, discarded from both texi and C
DEFHEADING(Standard options:)
STEXI
@table @option
ETEXI
DEF("help", 0, QEMU_OPTION_h,
"-h or -help display this help and exit\n", QEMU_ARCH_ALL)
STEXI
@item -h
@findex -h
Display help and exit
ETEXI
DEF("version", 0, QEMU_OPTION_version,
"-version display version information and exit\n", QEMU_ARCH_ALL)
STEXI
@item -version
@findex -version
Display version information and exit
ETEXI
DEF("machine", HAS_ARG, QEMU_OPTION_machine, \
"-machine [type=]name[,prop[=value][,...]]\n"
" selects emulated machine ('-machine help' for list)\n"
" property accel=accel1[:accel2[:...]] selects accelerator\n"
" supported accelerators are kvm, xen, hax or tcg (default: tcg)\n"
" kernel_irqchip=on|off|split controls accelerated irqchip support (default=off)\n"
" vmport=on|off|auto controls emulation of vmport (default: auto)\n"
" kvm_shadow_mem=size of KVM shadow MMU in bytes\n"
" dump-guest-core=on|off include guest memory in a core dump (default=on)\n"
" mem-merge=on|off controls memory merge support (default: on)\n"
" igd-passthru=on|off controls IGD GFX passthrough support (default=off)\n"
" aes-key-wrap=on|off controls support for AES key wrapping (default=on)\n"
" dea-key-wrap=on|off controls support for DEA key wrapping (default=on)\n"
" suppress-vmdesc=on|off disables self-describing migration (default=off)\n"
" nvdimm=on|off controls NVDIMM support (default=off)\n"
" enforce-config-section=on|off enforce configuration section migration (default=off)\n"
" s390-squash-mcss=on|off (deprecated) controls support for squashing into default css (default=off)\n",
QEMU_ARCH_ALL)
STEXI
@item -machine [type=]@var{name}[,prop=@var{value}[,...]]
@findex -machine
Select the emulated machine by @var{name}. Use @code{-machine help} to list
available machines.
For architectures which aim to support live migration compatibility
across releases, each release will introduce a new versioned machine
type. For example, the 2.8.0 release introduced machine types
``pc-i440fx-2.8'' and ``pc-q35-2.8'' for the x86_64/i686 architectures.
To allow live migration of guests from QEMU version 2.8.0, to QEMU
version 2.9.0, the 2.9.0 version must support the ``pc-i440fx-2.8''
and ``pc-q35-2.8'' machines too. To allow users live migrating VMs
to skip multiple intermediate releases when upgrading, new releases
of QEMU will support machine types from many previous versions.
Supported machine properties are:
@table @option
@item accel=@var{accels1}[:@var{accels2}[:...]]
This is used to enable an accelerator. Depending on the target architecture,
kvm, xen, hax or tcg can be available. By default, tcg is used. If there is
more than one accelerator specified, the next one is used if the previous one
fails to initialize.
@item kernel_irqchip=on|off
Controls in-kernel irqchip support for the chosen accelerator when available.
@item gfx_passthru=on|off
Enables IGD GFX passthrough support for the chosen machine when available.
@item vmport=on|off|auto
Enables emulation of VMWare IO port, for vmmouse etc. auto says to select the
value based on accel. For accel=xen the default is off otherwise the default
is on.
@item kvm_shadow_mem=size
Defines the size of the KVM shadow MMU.
@item dump-guest-core=on|off
Include guest memory in a core dump. The default is on.
@item mem-merge=on|off
Enables or disables memory merge support. This feature, when supported by
the host, de-duplicates identical memory pages among VMs instances
(enabled by default).
@item aes-key-wrap=on|off
Enables or disables AES key wrapping support on s390-ccw hosts. This feature
controls whether AES wrapping keys will be created to allow
execution of AES cryptographic functions. The default is on.
@item dea-key-wrap=on|off
Enables or disables DEA key wrapping support on s390-ccw hosts. This feature
controls whether DEA wrapping keys will be created to allow
execution of DEA cryptographic functions. The default is on.
@item nvdimm=on|off
Enables or disables NVDIMM support. The default is off.
@item s390-squash-mcss=on|off
Enables or disables squashing subchannels into the default css.
The default is off.
NOTE: This property is deprecated and will be removed in future releases.
The ``s390-squash-mcss=on`` property has been obsoleted by allowing the
cssid to be chosen freely. Instead of squashing subchannels into the
default channel subsystem image for guests that do not support multiple
channel subsystems, all devices can be put into the default channel
subsystem image.
@item enforce-config-section=on|off
If @option{enforce-config-section} is set to @var{on}, force migration
code to send configuration section even if the machine-type sets the
@option{migration.send-configuration} property to @var{off}.
NOTE: this parameter is deprecated. Please use @option{-global}
@option{migration.send-configuration}=@var{on|off} instead.
@end table
ETEXI
HXCOMM Deprecated by -machine
DEF("M", HAS_ARG, QEMU_OPTION_M, "", QEMU_ARCH_ALL)
DEF("cpu", HAS_ARG, QEMU_OPTION_cpu,
"-cpu cpu select CPU ('-cpu help' for list)\n", QEMU_ARCH_ALL)
STEXI
@item -cpu @var{model}
@findex -cpu
Select CPU model (@code{-cpu help} for list and additional feature selection)
ETEXI
DEF("accel", HAS_ARG, QEMU_OPTION_accel,
"-accel [accel=]accelerator[,thread=single|multi]\n"
" select accelerator (kvm, xen, hax or tcg; use 'help' for a list)\n"
help: Add newline to end of thread option help text The help text for the thread sub option of the accel option is missing a newline at the end. This is annoying as it makes it hard to see the help text for the next option. Add the new line so that the following option help text (-smp) is displayed on a new line rather on the same line and directly after the thread help. Before patch: -accel [accel=]accelerator[,thread=single|multi] select accelerator (kvm, xen, hax or tcg; use 'help' for a list) thread=single|multi (enable multi-threaded TCG)-smp [cpus=]n[,maxcpus=cpus][,cores=cores][,threads=threads][,sockets=sockets] set the number of CPUs to 'n' [default=1] maxcpus= maximum number of total cpus, including offline CPUs for hotplug, etc cores= number of CPU cores on one socket threads= number of threads on one CPU core sockets= number of discrete sockets in the system After patch: -accel [accel=]accelerator[,thread=single|multi] select accelerator (kvm, xen, hax or tcg; use 'help' for a list) thread=single|multi (enable multi-threaded TCG) -smp [cpus=]n[,maxcpus=cpus][,cores=cores][,threads=threads][,sockets=sockets] set the number of CPUs to 'n' [default=1] maxcpus= maximum number of total cpus, including offline CPUs for hotplug, etc cores= number of CPU cores on one socket threads= number of threads on one CPU core sockets= number of discrete sockets in the system Signed-off-by: Suraj Jitindar Singh <sjitindarsingh@gmail.com> Signed-off-by: Michael Tokarev <mjt@tls.msk.ru>
2017-05-31 14:11:50 +08:00
" thread=single|multi (enable multi-threaded TCG)\n", QEMU_ARCH_ALL)
STEXI
@item -accel @var{name}[,prop=@var{value}[,...]]
@findex -accel
This is used to enable an accelerator. Depending on the target architecture,
kvm, xen, hax or tcg can be available. By default, tcg is used. If there is
more than one accelerator specified, the next one is used if the previous one
fails to initialize.
@table @option
@item thread=single|multi
Controls number of TCG threads. When the TCG is multi-threaded there will be one
thread per vCPU therefor taking advantage of additional host cores. The default
is to enable multi-threading where both the back-end and front-ends support it and
no incompatible TCG features have been enabled (e.g. icount/replay).
@end table
ETEXI
DEF("smp", HAS_ARG, QEMU_OPTION_smp,
"-smp [cpus=]n[,maxcpus=cpus][,cores=cores][,threads=threads][,sockets=sockets]\n"
" set the number of CPUs to 'n' [default=1]\n"
" maxcpus= maximum number of total cpus, including\n"
" offline CPUs for hotplug, etc\n"
" cores= number of CPU cores on one socket\n"
" threads= number of threads on one CPU core\n"
" sockets= number of discrete sockets in the system\n",
QEMU_ARCH_ALL)
STEXI
@item -smp [cpus=]@var{n}[,cores=@var{cores}][,threads=@var{threads}][,sockets=@var{sockets}][,maxcpus=@var{maxcpus}]
@findex -smp
Simulate an SMP system with @var{n} CPUs. On the PC target, up to 255
CPUs are supported. On Sparc32 target, Linux limits the number of usable CPUs
to 4.
For the PC target, the number of @var{cores} per socket, the number
of @var{threads} per cores and the total number of @var{sockets} can be
specified. Missing values will be computed. If any on the three values is
given, the total number of CPUs @var{n} can be omitted. @var{maxcpus}
specifies the maximum number of hotpluggable CPUs.
ETEXI
DEF("numa", HAS_ARG, QEMU_OPTION_numa,
"-numa node[,mem=size][,cpus=firstcpu[-lastcpu]][,nodeid=node]\n"
"-numa node[,memdev=id][,cpus=firstcpu[-lastcpu]][,nodeid=node]\n"
"-numa dist,src=source,dst=destination,val=distance\n", QEMU_ARCH_ALL)
STEXI
@item -numa node[,mem=@var{size}][,cpus=@var{firstcpu}[-@var{lastcpu}]][,nodeid=@var{node}]
@itemx -numa node[,memdev=@var{id}][,cpus=@var{firstcpu}[-@var{lastcpu}]][,nodeid=@var{node}]
@itemx -numa dist,src=@var{source},dst=@var{destination},val=@var{distance}
numa: add '-numa cpu,...' option for property based node mapping legacy cpu to node mapping is using cpu index values to map VCPU to node with help of '-numa node,nodeid=node,cpus=x[-y]' option. However cpu index is internal concept and QEMU users have to guess /reimplement qemu's logic/ to map it to a concrete cpu socket/core/thread to make sane CPUs placement across numa nodes. This patch allows to map cpu objects to numa nodes using the same properties as used for cpus with -device/device_add (socket-id/core-id/thread-id/node-id). At present valid properties/values to address CPUs could be fetched using hotpluggable-cpus monitor/qmp command, it will require user to start qemu twice when creating domain to fetch possible CPUs for a machine type/-smp layout first and then the second time with numa explicit mapping for actual usage. The first step results could be saved and reused to set/change mapping later as far as machine type/-smp stays the same. Proposed impl. supports exact and wildcard matching to simplify CLI and allow to set mapping for a specific cpu or group of cpu objects specified by matched properties. For example: # exact mapping x86 -numa cpu,node-id=x,socket-id=y,core-id=z,thread-id=n # exact mapping SPAPR -numa cpu,node-id=x,core-id=y # wildcard mapping, all cpu objects that match socket-id=y # are mapped to node-id=x -numa cpu,node-id=x,socket-id=y Signed-off-by: Igor Mammedov <imammedo@redhat.com> Message-Id: <1494415802-227633-18-git-send-email-imammedo@redhat.com> Reviewed-by: David Gibson <david@gibson.dropbear.id.au> Signed-off-by: Eduardo Habkost <ehabkost@redhat.com>
2017-05-10 19:30:01 +08:00
@itemx -numa cpu,node-id=@var{node}[,socket-id=@var{x}][,core-id=@var{y}][,thread-id=@var{z}]
@findex -numa
Define a NUMA node and assign RAM and VCPUs to it.
Set the NUMA distance from a source node to a destination node.
numa: add '-numa cpu,...' option for property based node mapping legacy cpu to node mapping is using cpu index values to map VCPU to node with help of '-numa node,nodeid=node,cpus=x[-y]' option. However cpu index is internal concept and QEMU users have to guess /reimplement qemu's logic/ to map it to a concrete cpu socket/core/thread to make sane CPUs placement across numa nodes. This patch allows to map cpu objects to numa nodes using the same properties as used for cpus with -device/device_add (socket-id/core-id/thread-id/node-id). At present valid properties/values to address CPUs could be fetched using hotpluggable-cpus monitor/qmp command, it will require user to start qemu twice when creating domain to fetch possible CPUs for a machine type/-smp layout first and then the second time with numa explicit mapping for actual usage. The first step results could be saved and reused to set/change mapping later as far as machine type/-smp stays the same. Proposed impl. supports exact and wildcard matching to simplify CLI and allow to set mapping for a specific cpu or group of cpu objects specified by matched properties. For example: # exact mapping x86 -numa cpu,node-id=x,socket-id=y,core-id=z,thread-id=n # exact mapping SPAPR -numa cpu,node-id=x,core-id=y # wildcard mapping, all cpu objects that match socket-id=y # are mapped to node-id=x -numa cpu,node-id=x,socket-id=y Signed-off-by: Igor Mammedov <imammedo@redhat.com> Message-Id: <1494415802-227633-18-git-send-email-imammedo@redhat.com> Reviewed-by: David Gibson <david@gibson.dropbear.id.au> Signed-off-by: Eduardo Habkost <ehabkost@redhat.com>
2017-05-10 19:30:01 +08:00
Legacy VCPU assignment uses @samp{cpus} option where
@var{firstcpu} and @var{lastcpu} are CPU indexes. Each
@samp{cpus} option represent a contiguous range of CPU indexes
(or a single VCPU if @var{lastcpu} is omitted). A non-contiguous
set of VCPUs can be represented by providing multiple @samp{cpus}
options. If @samp{cpus} is omitted on all nodes, VCPUs are automatically
split between them.
For example, the following option assigns VCPUs 0, 1, 2 and 5 to
a NUMA node:
@example
-numa node,cpus=0-2,cpus=5
@end example
numa: add '-numa cpu,...' option for property based node mapping legacy cpu to node mapping is using cpu index values to map VCPU to node with help of '-numa node,nodeid=node,cpus=x[-y]' option. However cpu index is internal concept and QEMU users have to guess /reimplement qemu's logic/ to map it to a concrete cpu socket/core/thread to make sane CPUs placement across numa nodes. This patch allows to map cpu objects to numa nodes using the same properties as used for cpus with -device/device_add (socket-id/core-id/thread-id/node-id). At present valid properties/values to address CPUs could be fetched using hotpluggable-cpus monitor/qmp command, it will require user to start qemu twice when creating domain to fetch possible CPUs for a machine type/-smp layout first and then the second time with numa explicit mapping for actual usage. The first step results could be saved and reused to set/change mapping later as far as machine type/-smp stays the same. Proposed impl. supports exact and wildcard matching to simplify CLI and allow to set mapping for a specific cpu or group of cpu objects specified by matched properties. For example: # exact mapping x86 -numa cpu,node-id=x,socket-id=y,core-id=z,thread-id=n # exact mapping SPAPR -numa cpu,node-id=x,core-id=y # wildcard mapping, all cpu objects that match socket-id=y # are mapped to node-id=x -numa cpu,node-id=x,socket-id=y Signed-off-by: Igor Mammedov <imammedo@redhat.com> Message-Id: <1494415802-227633-18-git-send-email-imammedo@redhat.com> Reviewed-by: David Gibson <david@gibson.dropbear.id.au> Signed-off-by: Eduardo Habkost <ehabkost@redhat.com>
2017-05-10 19:30:01 +08:00
@samp{cpu} option is a new alternative to @samp{cpus} option
which uses @samp{socket-id|core-id|thread-id} properties to assign
CPU objects to a @var{node} using topology layout properties of CPU.
The set of properties is machine specific, and depends on used
machine type/@samp{smp} options. It could be queried with
@samp{hotpluggable-cpus} monitor command.
@samp{node-id} property specifies @var{node} to which CPU object
will be assigned, it's required for @var{node} to be declared
with @samp{node} option before it's used with @samp{cpu} option.
For example:
@example
-M pc \
-smp 1,sockets=2,maxcpus=2 \
-numa node,nodeid=0 -numa node,nodeid=1 \
-numa cpu,node-id=0,socket-id=0 -numa cpu,node-id=1,socket-id=1
@end example
@samp{mem} assigns a given RAM amount to a node. @samp{memdev}
assigns RAM from a given memory backend device to a node. If
@samp{mem} and @samp{memdev} are omitted in all nodes, RAM is
split equally between them.
@samp{mem} and @samp{memdev} are mutually exclusive. Furthermore,
if one node uses @samp{memdev}, all of them have to use it.
@var{source} and @var{destination} are NUMA node IDs.
@var{distance} is the NUMA distance from @var{source} to @var{destination}.
The distance from a node to itself is always 10. If any pair of nodes is
given a distance, then all pairs must be given distances. Although, when
distances are only given in one direction for each pair of nodes, then
the distances in the opposite directions are assumed to be the same. If,
however, an asymmetrical pair of distances is given for even one node
pair, then all node pairs must be provided distance values for both
directions, even when they are symmetrical. When a node is unreachable
from another node, set the pair's distance to 255.
Note that the -@option{numa} option doesn't allocate any of the
specified resources, it just assigns existing resources to NUMA
nodes. This means that one still has to use the @option{-m},
@option{-smp} options to allocate RAM and VCPUs respectively.
ETEXI
DEF("add-fd", HAS_ARG, QEMU_OPTION_add_fd,
"-add-fd fd=fd,set=set[,opaque=opaque]\n"
" Add 'fd' to fd 'set'\n", QEMU_ARCH_ALL)
STEXI
@item -add-fd fd=@var{fd},set=@var{set}[,opaque=@var{opaque}]
@findex -add-fd
Add a file descriptor to an fd set. Valid options are:
@table @option
@item fd=@var{fd}
This option defines the file descriptor of which a duplicate is added to fd set.
The file descriptor cannot be stdin, stdout, or stderr.
@item set=@var{set}
This option defines the ID of the fd set to add the file descriptor to.
@item opaque=@var{opaque}
This option defines a free-form string that can be used to describe @var{fd}.
@end table
You can open an image using pre-opened file descriptors from an fd set:
@example
qemu-system-i386
-add-fd fd=3,set=2,opaque="rdwr:/path/to/file"
-add-fd fd=4,set=2,opaque="rdonly:/path/to/file"
-drive file=/dev/fdset/2,index=0,media=disk
@end example
ETEXI
DEF("set", HAS_ARG, QEMU_OPTION_set,
"-set group.id.arg=value\n"
" set <arg> parameter for item <id> of type <group>\n"
" i.e. -set drive.$id.file=/path/to/image\n", QEMU_ARCH_ALL)
STEXI
@item -set @var{group}.@var{id}.@var{arg}=@var{value}
@findex -set
Set parameter @var{arg} for item @var{id} of type @var{group}
ETEXI
DEF("global", HAS_ARG, QEMU_OPTION_global,
"-global driver.property=value\n"
"-global driver=driver,property=property,value=value\n"
" set a global default for a driver property\n",
QEMU_ARCH_ALL)
STEXI
@item -global @var{driver}.@var{prop}=@var{value}
@itemx -global driver=@var{driver},property=@var{property},value=@var{value}
@findex -global
Set default value of @var{driver}'s property @var{prop} to @var{value}, e.g.:
@example
qemu-system-i386 -global ide-hd.physical_block_size=4096 disk-image.img
@end example
In particular, you can use this to set driver properties for devices which are
created automatically by the machine model. To create a device which is not
created automatically and set properties on it, use -@option{device}.
-global @var{driver}.@var{prop}=@var{value} is shorthand for -global
driver=@var{driver},property=@var{prop},value=@var{value}. The
longhand syntax works even when @var{driver} contains a dot.
ETEXI
DEF("boot", HAS_ARG, QEMU_OPTION_boot,
"-boot [order=drives][,once=drives][,menu=on|off]\n"
" [,splash=sp_name][,splash-time=sp_time][,reboot-timeout=rb_time][,strict=on|off]\n"
" 'drives': floppy (a), hard disk (c), CD-ROM (d), network (n)\n"
" 'sp_name': the file's name that would be passed to bios as logo picture, if menu=on\n"
" 'sp_time': the period that splash picture last if menu=on, unit is ms\n"
" 'rb_timeout': the timeout before guest reboot when boot failed, unit is ms\n",
QEMU_ARCH_ALL)
STEXI
@item -boot [order=@var{drives}][,once=@var{drives}][,menu=on|off][,splash=@var{sp_name}][,splash-time=@var{sp_time}][,reboot-timeout=@var{rb_timeout}][,strict=on|off]
@findex -boot
Specify boot order @var{drives} as a string of drive letters. Valid
drive letters depend on the target architecture. The x86 PC uses: a, b
(floppy 1 and 2), c (first hard disk), d (first CD-ROM), n-p (Etherboot
from network adapter 1-4), hard disk boot is the default. To apply a
particular boot order only on the first startup, specify it via
@option{once}. Note that the @option{order} or @option{once} parameter
should not be used together with the @option{bootindex} property of
devices, since the firmware implementations normally do not support both
at the same time.
Interactive boot menus/prompts can be enabled via @option{menu=on} as far
as firmware/BIOS supports them. The default is non-interactive boot.
A splash picture could be passed to bios, enabling user to show it as logo,
when option splash=@var{sp_name} is given and menu=on, If firmware/BIOS
supports them. Currently Seabios for X86 system support it.
limitation: The splash file could be a jpeg file or a BMP file in 24 BPP
format(true color). The resolution should be supported by the SVGA mode, so
the recommended is 320x240, 640x480, 800x640.
A timeout could be passed to bios, guest will pause for @var{rb_timeout} ms
when boot failed, then reboot. If @var{rb_timeout} is '-1', guest will not
reboot, qemu passes '-1' to bios by default. Currently Seabios for X86
system support it.
Do strict boot via @option{strict=on} as far as firmware/BIOS
supports it. This only effects when boot priority is changed by
bootindex options. The default is non-strict boot.
@example
# try to boot from network first, then from hard disk
qemu-system-i386 -boot order=nc
# boot from CD-ROM first, switch back to default order after reboot
qemu-system-i386 -boot once=d
# boot with a splash picture for 5 seconds.
qemu-system-i386 -boot menu=on,splash=/root/boot.bmp,splash-time=5000
@end example
Note: The legacy format '-boot @var{drives}' is still supported but its
use is discouraged as it may be removed from future versions.
ETEXI
DEF("m", HAS_ARG, QEMU_OPTION_m,
"-m [size=]megs[,slots=n,maxmem=size]\n"
" configure guest RAM\n"
" size: initial amount of guest memory\n"
" slots: number of hotplug slots (default: none)\n"
" maxmem: maximum amount of guest memory (default: none)\n"
"NOTE: Some architectures might enforce a specific granularity\n",
QEMU_ARCH_ALL)
STEXI
@item -m [size=]@var{megs}[,slots=n,maxmem=size]
@findex -m
Sets guest startup RAM size to @var{megs} megabytes. Default is 128 MiB.
Optionally, a suffix of ``M'' or ``G'' can be used to signify a value in
megabytes or gigabytes respectively. Optional pair @var{slots}, @var{maxmem}
could be used to set amount of hotpluggable memory slots and maximum amount of
memory. Note that @var{maxmem} must be aligned to the page size.
For example, the following command-line sets the guest startup RAM size to
1GB, creates 3 slots to hotplug additional memory and sets the maximum
memory the guest can reach to 4GB:
@example
qemu-system-x86_64 -m 1G,slots=3,maxmem=4G
@end example
If @var{slots} and @var{maxmem} are not specified, memory hotplug won't
be enabled and the guest startup RAM will never increase.
ETEXI
DEF("mem-path", HAS_ARG, QEMU_OPTION_mempath,
"-mem-path FILE provide backing storage for guest RAM\n", QEMU_ARCH_ALL)
STEXI
@item -mem-path @var{path}
@findex -mem-path
Allocate guest RAM from a temporarily created file in @var{path}.
ETEXI
DEF("mem-prealloc", 0, QEMU_OPTION_mem_prealloc,
"-mem-prealloc preallocate guest memory (use with -mem-path)\n",
QEMU_ARCH_ALL)
STEXI
@item -mem-prealloc
@findex -mem-prealloc
Preallocate memory when using -mem-path.
ETEXI
DEF("k", HAS_ARG, QEMU_OPTION_k,
"-k language use keyboard layout (for example 'fr' for French)\n",
QEMU_ARCH_ALL)
STEXI
@item -k @var{language}
@findex -k
Use keyboard layout @var{language} (for example @code{fr} for
French). This option is only needed where it is not easy to get raw PC
keycodes (e.g. on Macs, with some X11 servers or with a VNC or curses
display). You don't normally need to use it on PC/Linux or PC/Windows
hosts.
The available layouts are:
@example
ar de-ch es fo fr-ca hu ja mk no pt-br sv
da en-gb et fr fr-ch is lt nl pl ru th
de en-us fi fr-be hr it lv nl-be pt sl tr
@end example
The default is @code{en-us}.
ETEXI
DEF("audio-help", 0, QEMU_OPTION_audio_help,
"-audio-help print list of audio drivers and their options\n",
QEMU_ARCH_ALL)
STEXI
@item -audio-help
@findex -audio-help
Will show the audio subsystem help: list of drivers, tunable
parameters.
ETEXI
DEF("soundhw", HAS_ARG, QEMU_OPTION_soundhw,
"-soundhw c1,... enable audio support\n"
" and only specified sound cards (comma separated list)\n"
" use '-soundhw help' to get the list of supported cards\n"
" use '-soundhw all' to enable all of them\n", QEMU_ARCH_ALL)
STEXI
@item -soundhw @var{card1}[,@var{card2},...] or -soundhw all
@findex -soundhw
Enable audio and selected sound hardware. Use 'help' to print all
available sound hardware.
@example
qemu-system-i386 -soundhw sb16,adlib disk.img
qemu-system-i386 -soundhw es1370 disk.img
qemu-system-i386 -soundhw ac97 disk.img
qemu-system-i386 -soundhw hda disk.img
qemu-system-i386 -soundhw all disk.img
qemu-system-i386 -soundhw help
@end example
Note that Linux's i810_audio OSS kernel (for AC97) module might
require manually specifying clocking.
@example
modprobe i810_audio clocking=48000
@end example
ETEXI
DEF("balloon", HAS_ARG, QEMU_OPTION_balloon,
"-balloon none disable balloon device\n"
"-balloon virtio[,addr=str]\n"
" enable virtio balloon device (default)\n", QEMU_ARCH_ALL)
STEXI
@item -balloon none
@findex -balloon
Disable balloon device.
@item -balloon virtio[,addr=@var{addr}]
Enable virtio balloon device (default), optionally with PCI address
@var{addr}.
ETEXI
DEF("device", HAS_ARG, QEMU_OPTION_device,
"-device driver[,prop[=value][,...]]\n"
" add device (based on driver)\n"
" prop=value,... sets driver properties\n"
" use '-device help' to print all possible drivers\n"
" use '-device driver,help' to print all possible properties\n",
QEMU_ARCH_ALL)
STEXI
@item -device @var{driver}[,@var{prop}[=@var{value}][,...]]
@findex -device
Add device @var{driver}. @var{prop}=@var{value} sets driver
properties. Valid properties depend on the driver. To get help on
possible drivers and properties, use @code{-device help} and
@code{-device @var{driver},help}.
Some drivers are:
@item -device ipmi-bmc-sim,id=@var{id}[,slave_addr=@var{val}][,sdrfile=@var{file}][,furareasize=@var{val}][,furdatafile=@var{file}]
Add an IPMI BMC. This is a simulation of a hardware management
interface processor that normally sits on a system. It provides
a watchdog and the ability to reset and power control the system.
You need to connect this to an IPMI interface to make it useful
The IPMI slave address to use for the BMC. The default is 0x20.
This address is the BMC's address on the I2C network of management
controllers. If you don't know what this means, it is safe to ignore
it.
@table @option
@item bmc=@var{id}
The BMC to connect to, one of ipmi-bmc-sim or ipmi-bmc-extern above.
@item slave_addr=@var{val}
Define slave address to use for the BMC. The default is 0x20.
@item sdrfile=@var{file}
file containing raw Sensor Data Records (SDR) data. The default is none.
@item fruareasize=@var{val}
size of a Field Replaceable Unit (FRU) area. The default is 1024.
@item frudatafile=@var{file}
file containing raw Field Replaceable Unit (FRU) inventory data. The default is none.
@end table
@item -device ipmi-bmc-extern,id=@var{id},chardev=@var{id}[,slave_addr=@var{val}]
Add a connection to an external IPMI BMC simulator. Instead of
locally emulating the BMC like the above item, instead connect
to an external entity that provides the IPMI services.
A connection is made to an external BMC simulator. If you do this, it
is strongly recommended that you use the "reconnect=" chardev option
to reconnect to the simulator if the connection is lost. Note that if
this is not used carefully, it can be a security issue, as the
interface has the ability to send resets, NMIs, and power off the VM.
It's best if QEMU makes a connection to an external simulator running
on a secure port on localhost, so neither the simulator nor QEMU is
exposed to any outside network.
See the "lanserv/README.vm" file in the OpenIPMI library for more
details on the external interface.
@item -device isa-ipmi-kcs,bmc=@var{id}[,ioport=@var{val}][,irq=@var{val}]
Add a KCS IPMI interafce on the ISA bus. This also adds a
corresponding ACPI and SMBIOS entries, if appropriate.
@table @option
@item bmc=@var{id}
The BMC to connect to, one of ipmi-bmc-sim or ipmi-bmc-extern above.
@item ioport=@var{val}
Define the I/O address of the interface. The default is 0xca0 for KCS.
@item irq=@var{val}
Define the interrupt to use. The default is 5. To disable interrupts,
set this to 0.
@end table
@item -device isa-ipmi-bt,bmc=@var{id}[,ioport=@var{val}][,irq=@var{val}]
Like the KCS interface, but defines a BT interface. The default port is
0xe4 and the default interrupt is 5.
ETEXI
DEF("name", HAS_ARG, QEMU_OPTION_name,
"-name string1[,process=string2][,debug-threads=on|off]\n"
" set the name of the guest\n"
" string1 sets the window title and string2 the process name (on Linux)\n"
" When debug-threads is enabled, individual threads are given a separate name (on Linux)\n"
" NOTE: The thread names are for debugging and not a stable API.\n",
QEMU_ARCH_ALL)
STEXI
@item -name @var{name}
@findex -name
Sets the @var{name} of the guest.
This name will be displayed in the SDL window caption.
The @var{name} will also be used for the VNC server.
Also optionally set the top visible process name in Linux.
Naming of individual threads can also be enabled on Linux to aid debugging.
ETEXI
DEF("uuid", HAS_ARG, QEMU_OPTION_uuid,
"-uuid %08x-%04x-%04x-%04x-%012x\n"
" specify machine UUID\n", QEMU_ARCH_ALL)
STEXI
@item -uuid @var{uuid}
@findex -uuid
Set system UUID.
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
DEFHEADING(Block device options:)
STEXI
@table @option
ETEXI
DEF("fda", HAS_ARG, QEMU_OPTION_fda,
"-fda/-fdb file use 'file' as floppy disk 0/1 image\n", QEMU_ARCH_ALL)
DEF("fdb", HAS_ARG, QEMU_OPTION_fdb, "", QEMU_ARCH_ALL)
STEXI
@item -fda @var{file}
@itemx -fdb @var{file}
@findex -fda
@findex -fdb
Use @var{file} as floppy disk 0/1 image (@pxref{disk_images}).
ETEXI
DEF("hda", HAS_ARG, QEMU_OPTION_hda,
"-hda/-hdb file use 'file' as IDE hard disk 0/1 image\n", QEMU_ARCH_ALL)
DEF("hdb", HAS_ARG, QEMU_OPTION_hdb, "", QEMU_ARCH_ALL)
DEF("hdc", HAS_ARG, QEMU_OPTION_hdc,
"-hdc/-hdd file use 'file' as IDE hard disk 2/3 image\n", QEMU_ARCH_ALL)
DEF("hdd", HAS_ARG, QEMU_OPTION_hdd, "", QEMU_ARCH_ALL)
STEXI
@item -hda @var{file}
@itemx -hdb @var{file}
@itemx -hdc @var{file}
@itemx -hdd @var{file}
@findex -hda
@findex -hdb
@findex -hdc
@findex -hdd
Use @var{file} as hard disk 0, 1, 2 or 3 image (@pxref{disk_images}).
ETEXI
DEF("cdrom", HAS_ARG, QEMU_OPTION_cdrom,
"-cdrom file use 'file' as IDE cdrom image (cdrom is ide1 master)\n",
QEMU_ARCH_ALL)
STEXI
@item -cdrom @var{file}
@findex -cdrom
Use @var{file} as CD-ROM image (you cannot use @option{-hdc} and
@option{-cdrom} at the same time). You can use the host CD-ROM by
using @file{/dev/cdrom} as filename (@pxref{host_drives}).
ETEXI
DEF("blockdev", HAS_ARG, QEMU_OPTION_blockdev,
"-blockdev [driver=]driver[,node-name=N][,discard=ignore|unmap]\n"
" [,cache.direct=on|off][,cache.no-flush=on|off]\n"
" [,read-only=on|off][,detect-zeroes=on|off|unmap]\n"
" [,driver specific parameters...]\n"
" configure a block backend\n", QEMU_ARCH_ALL)
STEXI
@item -blockdev @var{option}[,@var{option}[,@var{option}[,...]]]
@findex -blockdev
Define a new block driver node. Some of the options apply to all block drivers,
other options are only accepted for a specific block driver. See below for a
list of generic options and options for the most common block drivers.
Options that expect a reference to another node (e.g. @code{file}) can be
given in two ways. Either you specify the node name of an already existing node
(file=@var{node-name}), or you define a new node inline, adding options
for the referenced node after a dot (file.filename=@var{path},file.aio=native).
A block driver node created with @option{-blockdev} can be used for a guest
device by specifying its node name for the @code{drive} property in a
@option{-device} argument that defines a block device.
@table @option
@item Valid options for any block driver node:
@table @code
@item driver
Specifies the block driver to use for the given node.
@item node-name
This defines the name of the block driver node by which it will be referenced
later. The name must be unique, i.e. it must not match the name of a different
block driver node, or (if you use @option{-drive} as well) the ID of a drive.
If no node name is specified, it is automatically generated. The generated node
name is not intended to be predictable and changes between QEMU invocations.
For the top level, an explicit node name must be specified.
@item read-only
Open the node read-only. Guest write attempts will fail.
@item cache.direct
The host page cache can be avoided with @option{cache.direct=on}. This will
attempt to do disk IO directly to the guest's memory. QEMU may still perform an
internal copy of the data.
@item cache.no-flush
In case you don't care about data integrity over host failures, you can use
@option{cache.no-flush=on}. This option tells QEMU that it never needs to write
any data to the disk but can instead keep things in cache. If anything goes
wrong, like your host losing power, the disk storage getting disconnected
accidentally, etc. your image will most probably be rendered unusable.
@item discard=@var{discard}
@var{discard} is one of "ignore" (or "off") or "unmap" (or "on") and controls
whether @code{discard} (also known as @code{trim} or @code{unmap}) requests are
ignored or passed to the filesystem. Some machine types may not support
discard requests.
@item detect-zeroes=@var{detect-zeroes}
@var{detect-zeroes} is "off", "on" or "unmap" and enables the automatic
conversion of plain zero writes by the OS to driver specific optimized
zero write commands. You may even choose "unmap" if @var{discard} is set
to "unmap" to allow a zero write to be converted to an @code{unmap} operation.
@end table
@item Driver-specific options for @code{file}
This is the protocol-level block driver for accessing regular files.
@table @code
@item filename
The path to the image file in the local filesystem
@item aio
Specifies the AIO backend (threads/native, default: threads)
@item locking
Specifies whether the image file is protected with Linux OFD / POSIX locks. The
default is to use the Linux Open File Descriptor API if available, otherwise no
lock is applied. (auto/on/off, default: auto)
@end table
Example:
@example
-blockdev driver=file,node-name=disk,filename=disk.img
@end example
@item Driver-specific options for @code{raw}
This is the image format block driver for raw images. It is usually
stacked on top of a protocol level block driver such as @code{file}.
@table @code
@item file
Reference to or definition of the data source block driver node
(e.g. a @code{file} driver node)
@end table
Example 1:
@example
-blockdev driver=file,node-name=disk_file,filename=disk.img
-blockdev driver=raw,node-name=disk,file=disk_file
@end example
Example 2:
@example
-blockdev driver=raw,node-name=disk,file.driver=file,file.filename=disk.img
@end example
@item Driver-specific options for @code{qcow2}
This is the image format block driver for qcow2 images. It is usually
stacked on top of a protocol level block driver such as @code{file}.
@table @code
@item file
Reference to or definition of the data source block driver node
(e.g. a @code{file} driver node)
@item backing
Reference to or definition of the backing file block device (default is taken
from the image file). It is allowed to pass an empty string here in order to
disable the default backing file.
@item lazy-refcounts
Whether to enable the lazy refcounts feature (on/off; default is taken from the
image file)
@item cache-size
The maximum total size of the L2 table and refcount block caches in bytes
(default: 1048576 bytes or 8 clusters, whichever is larger)
@item l2-cache-size
The maximum size of the L2 table cache in bytes
(default: 4/5 of the total cache size)
@item refcount-cache-size
The maximum size of the refcount block cache in bytes
(default: 1/5 of the total cache size)
@item cache-clean-interval
Clean unused entries in the L2 and refcount caches. The interval is in seconds.
The default value is 0 and it disables this feature.
@item pass-discard-request
Whether discard requests to the qcow2 device should be forwarded to the data
source (on/off; default: on if discard=unmap is specified, off otherwise)
@item pass-discard-snapshot
Whether discard requests for the data source should be issued when a snapshot
operation (e.g. deleting a snapshot) frees clusters in the qcow2 file (on/off;
default: on)
@item pass-discard-other
Whether discard requests for the data source should be issued on other
occasions where a cluster gets freed (on/off; default: off)
@item overlap-check
Which overlap checks to perform for writes to the image
(none/constant/cached/all; default: cached). For details or finer
granularity control refer to the QAPI documentation of @code{blockdev-add}.
@end table
Example 1:
@example
-blockdev driver=file,node-name=my_file,filename=/tmp/disk.qcow2
-blockdev driver=qcow2,node-name=hda,file=my_file,overlap-check=none,cache-size=16777216
@end example
Example 2:
@example
-blockdev driver=qcow2,node-name=disk,file.driver=http,file.filename=http://example.com/image.qcow2
@end example
@item Driver-specific options for other drivers
Please refer to the QAPI documentation of the @code{blockdev-add} QMP command.
@end table
ETEXI
DEF("drive", HAS_ARG, QEMU_OPTION_drive,
"-drive [file=file][,if=type][,bus=n][,unit=m][,media=d][,index=i]\n"
" [,cyls=c,heads=h,secs=s[,trans=t]][,snapshot=on|off]\n"
" [,cache=writethrough|writeback|none|directsync|unsafe][,format=f]\n"
" [,serial=s][,addr=A][,rerror=ignore|stop|report]\n"
" [,werror=ignore|stop|report|enospc][,id=name][,aio=threads|native]\n"
" [,readonly=on|off][,copy-on-read=on|off]\n"
" [,discard=ignore|unmap][,detect-zeroes=on|off|unmap]\n"
" [[,bps=b]|[[,bps_rd=r][,bps_wr=w]]]\n"
" [[,iops=i]|[[,iops_rd=r][,iops_wr=w]]]\n"
" [[,bps_max=bm]|[[,bps_rd_max=rm][,bps_wr_max=wm]]]\n"
" [[,iops_max=im]|[[,iops_rd_max=irm][,iops_wr_max=iwm]]]\n"
" [[,iops_size=is]]\n"
" [[,group=g]]\n"
" use 'file' as a drive image\n", QEMU_ARCH_ALL)
STEXI
@item -drive @var{option}[,@var{option}[,@var{option}[,...]]]
@findex -drive
Define a new drive. This includes creating a block driver node (the backend) as
well as a guest device, and is mostly a shortcut for defining the corresponding
@option{-blockdev} and @option{-device} options.
@option{-drive} accepts all options that are accepted by @option{-blockdev}. In
addition, it knows the following options:
@table @option
@item file=@var{file}
This option defines which disk image (@pxref{disk_images}) to use with
this drive. If the filename contains comma, you must double it
(for instance, "file=my,,file" to use file "my,file").
Special files such as iSCSI devices can be specified using protocol
specific URLs. See the section for "Device URL Syntax" for more information.
@item if=@var{interface}
This option defines on which type on interface the drive is connected.
Available types are: ide, scsi, sd, mtd, floppy, pflash, virtio, none.
@item bus=@var{bus},unit=@var{unit}
These options define where is connected the drive by defining the bus number and
the unit id.
@item index=@var{index}
This option defines where is connected the drive by using an index in the list
of available connectors of a given interface type.
@item media=@var{media}
This option defines the type of the media: disk or cdrom.
@item cyls=@var{c},heads=@var{h},secs=@var{s}[,trans=@var{t}]
These options have the same definition as they have in @option{-hdachs}.
These parameters are deprecated, use the corresponding parameters
of @code{-device} instead.
@item snapshot=@var{snapshot}
@var{snapshot} is "on" or "off" and controls snapshot mode for the given drive
(see @option{-snapshot}).
@item cache=@var{cache}
@var{cache} is "none", "writeback", "unsafe", "directsync" or "writethrough"
and controls how the host cache is used to access block data. This is a
shortcut that sets the @option{cache.direct} and @option{cache.no-flush}
options (as in @option{-blockdev}), and additionally @option{cache.writeback},
which provides a default for the @option{write-cache} option of block guest
devices (as in @option{-device}). The modes correspond to the following
settings:
@c Our texi2pod.pl script doesn't support @multitable, so fall back to using
@c plain ASCII art (well, UTF-8 art really). This looks okay both in the manpage
@c and the HTML output.
@example
@ cache.writeback cache.direct cache.no-flush
writeback on off off
none on on off
writethrough off off off
directsync off on off
unsafe on off on
@end example
The default mode is @option{cache=writeback}.
@item aio=@var{aio}
@var{aio} is "threads", or "native" and selects between pthread based disk I/O and native Linux AIO.
@item format=@var{format}
Specify which disk @var{format} will be used rather than detecting
the format. Can be used to specify format=raw to avoid interpreting
an untrusted format header.
@item serial=@var{serial}
This option specifies the serial number to assign to the device. This
parameter is deprecated, use the corresponding parameter of @code{-device}
instead.
@item addr=@var{addr}
Specify the controller's PCI address (if=virtio only). This parameter is
deprecated, use the corresponding parameter of @code{-device} instead.
@item werror=@var{action},rerror=@var{action}
Specify which @var{action} to take on write and read errors. Valid actions are:
"ignore" (ignore the error and try to continue), "stop" (pause QEMU),
"report" (report the error to the guest), "enospc" (pause QEMU only if the
host disk is full; report the error to the guest otherwise).
The default setting is @option{werror=enospc} and @option{rerror=report}.
@item copy-on-read=@var{copy-on-read}
@var{copy-on-read} is "on" or "off" and enables whether to copy read backing
file sectors into the image file.
@item bps=@var{b},bps_rd=@var{r},bps_wr=@var{w}
Specify bandwidth throttling limits in bytes per second, either for all request
types or for reads or writes only. Small values can lead to timeouts or hangs
inside the guest. A safe minimum for disks is 2 MB/s.
@item bps_max=@var{bm},bps_rd_max=@var{rm},bps_wr_max=@var{wm}
Specify bursts in bytes per second, either for all request types or for reads
or writes only. Bursts allow the guest I/O to spike above the limit
temporarily.
@item iops=@var{i},iops_rd=@var{r},iops_wr=@var{w}
Specify request rate limits in requests per second, either for all request
types or for reads or writes only.
@item iops_max=@var{bm},iops_rd_max=@var{rm},iops_wr_max=@var{wm}
Specify bursts in requests per second, either for all request types or for reads
or writes only. Bursts allow the guest I/O to spike above the limit
temporarily.
@item iops_size=@var{is}
Let every @var{is} bytes of a request count as a new request for iops
throttling purposes. Use this option to prevent guests from circumventing iops
limits by sending fewer but larger requests.
@item group=@var{g}
Join a throttling quota group with given name @var{g}. All drives that are
members of the same group are accounted for together. Use this option to
prevent guests from circumventing throttling limits by using many small disks
instead of a single larger disk.
@end table
By default, the @option{cache.writeback=on} mode is used. It will report data
writes as completed as soon as the data is present in the host page cache.
This is safe as long as your guest OS makes sure to correctly flush disk caches
where needed. If your guest OS does not handle volatile disk write caches
correctly and your host crashes or loses power, then the guest may experience
data corruption.
For such guests, you should consider using @option{cache.writeback=off}. This
means that the host page cache will be used to read and write data, but write
notification will be sent to the guest only after QEMU has made sure to flush
each write to the disk. Be aware that this has a major impact on performance.
When using the @option{-snapshot} option, unsafe caching is always used.
Copy-on-read avoids accessing the same backing file sectors repeatedly and is
useful when the backing file is over a slow network. By default copy-on-read
is off.
Instead of @option{-cdrom} you can use:
@example
qemu-system-i386 -drive file=file,index=2,media=cdrom
@end example
Instead of @option{-hda}, @option{-hdb}, @option{-hdc}, @option{-hdd}, you can
use:
@example
qemu-system-i386 -drive file=file,index=0,media=disk
qemu-system-i386 -drive file=file,index=1,media=disk
qemu-system-i386 -drive file=file,index=2,media=disk
qemu-system-i386 -drive file=file,index=3,media=disk
@end example
You can open an image using pre-opened file descriptors from an fd set:
@example
qemu-system-i386
-add-fd fd=3,set=2,opaque="rdwr:/path/to/file"
-add-fd fd=4,set=2,opaque="rdonly:/path/to/file"
-drive file=/dev/fdset/2,index=0,media=disk
@end example
You can connect a CDROM to the slave of ide0:
@example
qemu-system-i386 -drive file=file,if=ide,index=1,media=cdrom
@end example
If you don't specify the "file=" argument, you define an empty drive:
@example
qemu-system-i386 -drive if=ide,index=1,media=cdrom
@end example
Instead of @option{-fda}, @option{-fdb}, you can use:
@example
qemu-system-i386 -drive file=file,index=0,if=floppy
qemu-system-i386 -drive file=file,index=1,if=floppy
@end example
By default, @var{interface} is "ide" and @var{index} is automatically
incremented:
@example
qemu-system-i386 -drive file=a -drive file=b"
@end example
is interpreted like:
@example
qemu-system-i386 -hda a -hdb b
@end example
ETEXI
DEF("mtdblock", HAS_ARG, QEMU_OPTION_mtdblock,
"-mtdblock file use 'file' as on-board Flash memory image\n",
QEMU_ARCH_ALL)
STEXI
@item -mtdblock @var{file}
@findex -mtdblock
Use @var{file} as on-board Flash memory image.
ETEXI
DEF("sd", HAS_ARG, QEMU_OPTION_sd,
"-sd file use 'file' as SecureDigital card image\n", QEMU_ARCH_ALL)
STEXI
@item -sd @var{file}
@findex -sd
Use @var{file} as SecureDigital card image.
ETEXI
DEF("pflash", HAS_ARG, QEMU_OPTION_pflash,
"-pflash file use 'file' as a parallel flash image\n", QEMU_ARCH_ALL)
STEXI
@item -pflash @var{file}
@findex -pflash
Use @var{file} as a parallel flash image.
ETEXI
DEF("snapshot", 0, QEMU_OPTION_snapshot,
"-snapshot write to temporary files instead of disk image files\n",
QEMU_ARCH_ALL)
STEXI
@item -snapshot
@findex -snapshot
Write to temporary files instead of disk image files. In this case,
the raw disk image you use is not written back. You can however force
the write back by pressing @key{C-a s} (@pxref{disk_images}).
ETEXI
DEF("hdachs", HAS_ARG, QEMU_OPTION_hdachs, \
"-hdachs c,h,s[,t]\n" \
" force hard disk 0 physical geometry and the optional BIOS\n" \
" translation (t=none or lba) (usually QEMU can guess them)\n",
QEMU_ARCH_ALL)
STEXI
@item -hdachs @var{c},@var{h},@var{s},[,@var{t}]
@findex -hdachs
Force hard disk 0 physical geometry (1 <= @var{c} <= 16383, 1 <=
@var{h} <= 16, 1 <= @var{s} <= 63) and optionally force the BIOS
translation mode (@var{t}=none, lba or auto). Usually QEMU can guess
all those parameters. This option is deprecated, please use
@code{-device ide-hd,cyls=c,heads=h,secs=s,...} instead.
ETEXI
DEF("fsdev", HAS_ARG, QEMU_OPTION_fsdev,
"-fsdev fsdriver,id=id[,path=path,][security_model={mapped-xattr|mapped-file|passthrough|none}]\n"
" [,writeout=immediate][,readonly][,socket=socket|sock_fd=sock_fd][,fmode=fmode][,dmode=dmode]\n"
" [[,throttling.bps-total=b]|[[,throttling.bps-read=r][,throttling.bps-write=w]]]\n"
" [[,throttling.iops-total=i]|[[,throttling.iops-read=r][,throttling.iops-write=w]]]\n"
" [[,throttling.bps-total-max=bm]|[[,throttling.bps-read-max=rm][,throttling.bps-write-max=wm]]]\n"
" [[,throttling.iops-total-max=im]|[[,throttling.iops-read-max=irm][,throttling.iops-write-max=iwm]]]\n"
" [[,throttling.iops-size=is]]\n",
QEMU_ARCH_ALL)
STEXI
@item -fsdev @var{fsdriver},id=@var{id},path=@var{path},[security_model=@var{security_model}][,writeout=@var{writeout}][,readonly][,socket=@var{socket}|sock_fd=@var{sock_fd}][,fmode=@var{fmode}][,dmode=@var{dmode}]
@findex -fsdev
Define a new file system device. Valid options are:
@table @option
@item @var{fsdriver}
This option specifies the fs driver backend to use.
Currently "local", "handle" and "proxy" file system drivers are supported.
@item id=@var{id}
Specifies identifier for this device
@item path=@var{path}
Specifies the export path for the file system device. Files under
this path will be available to the 9p client on the guest.
@item security_model=@var{security_model}
Specifies the security model to be used for this export path.
Supported security models are "passthrough", "mapped-xattr", "mapped-file" and "none".
In "passthrough" security model, files are stored using the same
credentials as they are created on the guest. This requires QEMU
to run as root. In "mapped-xattr" security model, some of the file
attributes like uid, gid, mode bits and link target are stored as
file attributes. For "mapped-file" these attributes are stored in the
hidden .virtfs_metadata directory. Directories exported by this security model cannot
interact with other unix tools. "none" security model is same as
passthrough except the sever won't report failures if it fails to
set file attributes like ownership. Security model is mandatory
only for local fsdriver. Other fsdrivers (like handle, proxy) don't take
security model as a parameter.
@item writeout=@var{writeout}
This is an optional argument. The only supported value is "immediate".
This means that host page cache will be used to read and write data but
write notification will be sent to the guest only when the data has been
reported as written by the storage subsystem.
@item readonly
Enables exporting 9p share as a readonly mount for guests. By default
read-write access is given.
@item socket=@var{socket}
Enables proxy filesystem driver to use passed socket file for communicating
with virtfs-proxy-helper
@item sock_fd=@var{sock_fd}
Enables proxy filesystem driver to use passed socket descriptor for
communicating with virtfs-proxy-helper. Usually a helper like libvirt
will create socketpair and pass one of the fds as sock_fd
@item fmode=@var{fmode}
Specifies the default mode for newly created files on the host. Works only
with security models "mapped-xattr" and "mapped-file".
@item dmode=@var{dmode}
Specifies the default mode for newly created directories on the host. Works
only with security models "mapped-xattr" and "mapped-file".
@end table
-fsdev option is used along with -device driver "virtio-9p-pci".
@item -device virtio-9p-pci,fsdev=@var{id},mount_tag=@var{mount_tag}
Options for virtio-9p-pci driver are:
@table @option
@item fsdev=@var{id}
Specifies the id value specified along with -fsdev option
@item mount_tag=@var{mount_tag}
Specifies the tag name to be used by the guest to mount this export point
@end table
ETEXI
DEF("virtfs", HAS_ARG, QEMU_OPTION_virtfs,
"-virtfs local,path=path,mount_tag=tag,security_model=[mapped-xattr|mapped-file|passthrough|none]\n"
" [,id=id][,writeout=immediate][,readonly][,socket=socket|sock_fd=sock_fd][,fmode=fmode][,dmode=dmode]\n",
QEMU_ARCH_ALL)
STEXI
@item -virtfs @var{fsdriver}[,path=@var{path}],mount_tag=@var{mount_tag}[,security_model=@var{security_model}][,writeout=@var{writeout}][,readonly][,socket=@var{socket}|sock_fd=@var{sock_fd}][,fmode=@var{fmode}][,dmode=@var{dmode}]
@findex -virtfs
The general form of a Virtual File system pass-through options are:
@table @option
@item @var{fsdriver}
This option specifies the fs driver backend to use.
Currently "local", "handle" and "proxy" file system drivers are supported.
@item id=@var{id}
Specifies identifier for this device
@item path=@var{path}
Specifies the export path for the file system device. Files under
this path will be available to the 9p client on the guest.
@item security_model=@var{security_model}
Specifies the security model to be used for this export path.
Supported security models are "passthrough", "mapped-xattr", "mapped-file" and "none".
In "passthrough" security model, files are stored using the same
credentials as they are created on the guest. This requires QEMU
to run as root. In "mapped-xattr" security model, some of the file
attributes like uid, gid, mode bits and link target are stored as
file attributes. For "mapped-file" these attributes are stored in the
hidden .virtfs_metadata directory. Directories exported by this security model cannot
interact with other unix tools. "none" security model is same as
passthrough except the sever won't report failures if it fails to
set file attributes like ownership. Security model is mandatory only
for local fsdriver. Other fsdrivers (like handle, proxy) don't take security
model as a parameter.
@item writeout=@var{writeout}
This is an optional argument. The only supported value is "immediate".
This means that host page cache will be used to read and write data but
write notification will be sent to the guest only when the data has been
reported as written by the storage subsystem.
@item readonly
Enables exporting 9p share as a readonly mount for guests. By default
read-write access is given.
@item socket=@var{socket}
Enables proxy filesystem driver to use passed socket file for
communicating with virtfs-proxy-helper. Usually a helper like libvirt
will create socketpair and pass one of the fds as sock_fd
@item sock_fd
Enables proxy filesystem driver to use passed 'sock_fd' as the socket
descriptor for interfacing with virtfs-proxy-helper
@item fmode=@var{fmode}
Specifies the default mode for newly created files on the host. Works only
with security models "mapped-xattr" and "mapped-file".
@item dmode=@var{dmode}
Specifies the default mode for newly created directories on the host. Works
only with security models "mapped-xattr" and "mapped-file".
@end table
ETEXI
DEF("virtfs_synth", 0, QEMU_OPTION_virtfs_synth,
"-virtfs_synth Create synthetic file system image\n",
QEMU_ARCH_ALL)
STEXI
@item -virtfs_synth
@findex -virtfs_synth
Create synthetic file system image
ETEXI
DEF("iscsi", HAS_ARG, QEMU_OPTION_iscsi,
"-iscsi [user=user][,password=password]\n"
" [,header-digest=CRC32C|CR32C-NONE|NONE-CRC32C|NONE\n"
" [,initiator-name=initiator-iqn][,id=target-iqn]\n"
" [,timeout=timeout]\n"
" iSCSI session parameters\n", QEMU_ARCH_ALL)
STEXI
@item -iscsi
@findex -iscsi
Configure iSCSI session parameters.
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
DEFHEADING(USB options:)
STEXI
@table @option
ETEXI
DEF("usb", 0, QEMU_OPTION_usb,
"-usb enable the USB driver (if it is not used by default yet)\n",
QEMU_ARCH_ALL)
STEXI
@item -usb
@findex -usb
Enable the USB driver (if it is not used by default yet).
ETEXI
DEF("usbdevice", HAS_ARG, QEMU_OPTION_usbdevice,
"-usbdevice name add the host or guest USB device 'name'\n",
QEMU_ARCH_ALL)
STEXI
@item -usbdevice @var{devname}
@findex -usbdevice
Add the USB device @var{devname}. Note that this option is deprecated,
please use @code{-device usb-...} instead. @xref{usb_devices}.
@table @option
@item mouse
Virtual Mouse. This will override the PS/2 mouse emulation when activated.
@item tablet
Pointer device that uses absolute coordinates (like a touchscreen). This
means QEMU is able to report the mouse position without having to grab the
mouse. Also overrides the PS/2 mouse emulation when activated.
@item disk:[format=@var{format}]:@var{file}
Mass storage device based on file. The optional @var{format} argument
will be used rather than detecting the format. Can be used to specify
@code{format=raw} to avoid interpreting an untrusted format header.
@item host:@var{bus}.@var{addr}
Pass through the host device identified by @var{bus}.@var{addr} (Linux only).
@item host:@var{vendor_id}:@var{product_id}
Pass through the host device identified by @var{vendor_id}:@var{product_id}
(Linux only).
@item serial:[vendorid=@var{vendor_id}][,productid=@var{product_id}]:@var{dev}
Serial converter to host character device @var{dev}, see @code{-serial} for the
available devices.
@item braille
Braille device. This will use BrlAPI to display the braille output on a real
or fake device.
@item net:@var{options}
Network adapter that supports CDC ethernet and RNDIS protocols.
@end table
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
DEFHEADING(Display options:)
STEXI
@table @option
ETEXI
DEF("display", HAS_ARG, QEMU_OPTION_display,
"-display sdl[,frame=on|off][,alt_grab=on|off][,ctrl_grab=on|off]\n"
" [,window_close=on|off][,gl=on|off]\n"
"-display gtk[,grab_on_hover=on|off][,gl=on|off]|\n"
"-display vnc=<display>[,<optargs>]\n"
"-display curses\n"
"-display none"
" select display type\n"
"The default display is equivalent to\n"
#if defined(CONFIG_GTK)
"\t\"-display gtk\"\n"
#elif defined(CONFIG_SDL)
"\t\"-display sdl\"\n"
#elif defined(CONFIG_COCOA)
"\t\"-display cocoa\"\n"
#elif defined(CONFIG_VNC)
"\t\"-vnc localhost:0,to=99,id=default\"\n"
#else
"\t\"-display none\"\n"
#endif
, QEMU_ARCH_ALL)
STEXI
@item -display @var{type}
@findex -display
Select type of display to use. This option is a replacement for the
old style -sdl/-curses/... options. Valid values for @var{type} are
@table @option
@item sdl
Display video output via SDL (usually in a separate graphics
window; see the SDL documentation for other possibilities).
@item curses
Display video output via curses. For graphics device models which
support a text mode, QEMU can display this output using a
curses/ncurses interface. Nothing is displayed when the graphics
device is in graphical mode or if the graphics device does not support
a text mode. Generally only the VGA device models support text mode.
@item none
Do not display video output. The guest will still see an emulated
graphics card, but its output will not be displayed to the QEMU
user. This option differs from the -nographic option in that it
only affects what is done with video output; -nographic also changes
the destination of the serial and parallel port data.
@item gtk
Display video output in a GTK window. This interface provides drop-down
menus and other UI elements to configure and control the VM during
runtime.
@item vnc
Start a VNC server on display <arg>
@end table
ETEXI
DEF("nographic", 0, QEMU_OPTION_nographic,
"-nographic disable graphical output and redirect serial I/Os to console\n",
QEMU_ARCH_ALL)
STEXI
@item -nographic
@findex -nographic
Normally, if QEMU is compiled with graphical window support, it displays
output such as guest graphics, guest console, and the QEMU monitor in a
window. With this option, you can totally disable graphical output so
that QEMU is a simple command line application. The emulated serial port
is redirected on the console and muxed with the monitor (unless
redirected elsewhere explicitly). Therefore, you can still use QEMU to
debug a Linux kernel with a serial console. Use @key{C-a h} for help on
switching between the console and monitor.
ETEXI
DEF("curses", 0, QEMU_OPTION_curses,
"-curses shorthand for -display curses\n",
QEMU_ARCH_ALL)
STEXI
@item -curses
@findex -curses
Normally, if QEMU is compiled with graphical window support, it displays
output such as guest graphics, guest console, and the QEMU monitor in a
window. With this option, QEMU can display the VGA output when in text
mode using a curses/ncurses interface. Nothing is displayed in graphical
mode.
ETEXI
DEF("no-frame", 0, QEMU_OPTION_no_frame,
"-no-frame open SDL window without a frame and window decorations\n",
QEMU_ARCH_ALL)
STEXI
@item -no-frame
@findex -no-frame
Do not use decorations for SDL windows and start them using the whole
available screen space. This makes the using QEMU in a dedicated desktop
workspace more convenient.
ETEXI
DEF("alt-grab", 0, QEMU_OPTION_alt_grab,
"-alt-grab use Ctrl-Alt-Shift to grab mouse (instead of Ctrl-Alt)\n",
QEMU_ARCH_ALL)
STEXI
@item -alt-grab
@findex -alt-grab
Use Ctrl-Alt-Shift to grab mouse (instead of Ctrl-Alt). Note that this also
affects the special keys (for fullscreen, monitor-mode switching, etc).
ETEXI
DEF("ctrl-grab", 0, QEMU_OPTION_ctrl_grab,
"-ctrl-grab use Right-Ctrl to grab mouse (instead of Ctrl-Alt)\n",
QEMU_ARCH_ALL)
STEXI
@item -ctrl-grab
@findex -ctrl-grab
Use Right-Ctrl to grab mouse (instead of Ctrl-Alt). Note that this also
affects the special keys (for fullscreen, monitor-mode switching, etc).
ETEXI
DEF("no-quit", 0, QEMU_OPTION_no_quit,
"-no-quit disable SDL window close capability\n", QEMU_ARCH_ALL)
STEXI
@item -no-quit
@findex -no-quit
Disable SDL window close capability.
ETEXI
DEF("sdl", 0, QEMU_OPTION_sdl,
"-sdl shorthand for -display sdl\n", QEMU_ARCH_ALL)
STEXI
@item -sdl
@findex -sdl
Enable SDL.
ETEXI
DEF("spice", HAS_ARG, QEMU_OPTION_spice,
"-spice [port=port][,tls-port=secured-port][,x509-dir=<dir>]\n"
" [,x509-key-file=<file>][,x509-key-password=<file>]\n"
" [,x509-cert-file=<file>][,x509-cacert-file=<file>]\n"
" [,x509-dh-key-file=<file>][,addr=addr][,ipv4|ipv6|unix]\n"
" [,tls-ciphers=<list>]\n"
" [,tls-channel=[main|display|cursor|inputs|record|playback]]\n"
" [,plaintext-channel=[main|display|cursor|inputs|record|playback]]\n"
" [,sasl][,password=<secret>][,disable-ticketing]\n"
" [,image-compression=[auto_glz|auto_lz|quic|glz|lz|off]]\n"
" [,jpeg-wan-compression=[auto|never|always]]\n"
" [,zlib-glz-wan-compression=[auto|never|always]]\n"
" [,streaming-video=[off|all|filter]][,disable-copy-paste]\n"
" [,disable-agent-file-xfer][,agent-mouse=[on|off]]\n"
" [,playback-compression=[on|off]][,seamless-migration=[on|off]]\n"
" [,gl=[on|off]][,rendernode=<file>]\n"
" enable spice\n"
" at least one of {port, tls-port} is mandatory\n",
QEMU_ARCH_ALL)
STEXI
@item -spice @var{option}[,@var{option}[,...]]
@findex -spice
Enable the spice remote desktop protocol. Valid options are
@table @option
@item port=<nr>
Set the TCP port spice is listening on for plaintext channels.
@item addr=<addr>
Set the IP address spice is listening on. Default is any address.
@item ipv4
@itemx ipv6
@itemx unix
Force using the specified IP version.
@item password=<secret>
Set the password you need to authenticate.
@item sasl
Require that the client use SASL to authenticate with the spice.
The exact choice of authentication method used is controlled from the
system / user's SASL configuration file for the 'qemu' service. This
is typically found in /etc/sasl2/qemu.conf. If running QEMU as an
unprivileged user, an environment variable SASL_CONF_PATH can be used
to make it search alternate locations for the service config.
While some SASL auth methods can also provide data encryption (eg GSSAPI),
it is recommended that SASL always be combined with the 'tls' and
'x509' settings to enable use of SSL and server certificates. This
ensures a data encryption preventing compromise of authentication
credentials.
@item disable-ticketing
Allow client connects without authentication.
@item disable-copy-paste
Disable copy paste between the client and the guest.
@item disable-agent-file-xfer
Disable spice-vdagent based file-xfer between the client and the guest.
@item tls-port=<nr>
Set the TCP port spice is listening on for encrypted channels.
@item x509-dir=<dir>
Set the x509 file directory. Expects same filenames as -vnc $display,x509=$dir
@item x509-key-file=<file>
@itemx x509-key-password=<file>
@itemx x509-cert-file=<file>
@itemx x509-cacert-file=<file>
@itemx x509-dh-key-file=<file>
The x509 file names can also be configured individually.
@item tls-ciphers=<list>
Specify which ciphers to use.
@item tls-channel=[main|display|cursor|inputs|record|playback]
@itemx plaintext-channel=[main|display|cursor|inputs|record|playback]
Force specific channel to be used with or without TLS encryption. The
options can be specified multiple times to configure multiple
channels. The special name "default" can be used to set the default
mode. For channels which are not explicitly forced into one mode the
spice client is allowed to pick tls/plaintext as he pleases.
@item image-compression=[auto_glz|auto_lz|quic|glz|lz|off]
Configure image compression (lossless).
Default is auto_glz.
@item jpeg-wan-compression=[auto|never|always]
@itemx zlib-glz-wan-compression=[auto|never|always]
Configure wan image compression (lossy for slow links).
Default is auto.
@item streaming-video=[off|all|filter]
Configure video stream detection. Default is off.
@item agent-mouse=[on|off]
Enable/disable passing mouse events via vdagent. Default is on.
@item playback-compression=[on|off]
Enable/disable audio stream compression (using celt 0.5.1). Default is on.
@item seamless-migration=[on|off]
Enable/disable spice seamless migration. Default is off.
@item gl=[on|off]
Enable/disable OpenGL context. Default is off.
@item rendernode=<file>
DRM render node for OpenGL rendering. If not specified, it will pick
the first available. (Since 2.9)
@end table
ETEXI
DEF("portrait", 0, QEMU_OPTION_portrait,
"-portrait rotate graphical output 90 deg left (only PXA LCD)\n",
QEMU_ARCH_ALL)
STEXI
@item -portrait
@findex -portrait
Rotate graphical output 90 deg left (only PXA LCD).
ETEXI
DEF("rotate", HAS_ARG, QEMU_OPTION_rotate,
"-rotate <deg> rotate graphical output some deg left (only PXA LCD)\n",
QEMU_ARCH_ALL)
STEXI
@item -rotate @var{deg}
@findex -rotate
Rotate graphical output some deg left (only PXA LCD).
ETEXI
DEF("vga", HAS_ARG, QEMU_OPTION_vga,
"-vga [std|cirrus|vmware|qxl|xenfb|tcx|cg3|virtio|none]\n"
" select video card type\n", QEMU_ARCH_ALL)
STEXI
@item -vga @var{type}
@findex -vga
Select type of VGA card to emulate. Valid values for @var{type} are
@table @option
@item cirrus
Cirrus Logic GD5446 Video card. All Windows versions starting from
Windows 95 should recognize and use this graphic card. For optimal
performances, use 16 bit color depth in the guest and the host OS.
(This card was the default before QEMU 2.2)
@item std
Standard VGA card with Bochs VBE extensions. If your guest OS
supports the VESA 2.0 VBE extensions (e.g. Windows XP) and if you want
to use high resolution modes (>= 1280x1024x16) then you should use
this option. (This card is the default since QEMU 2.2)
@item vmware
VMWare SVGA-II compatible adapter. Use it if you have sufficiently
recent XFree86/XOrg server or Windows guest with a driver for this
card.
@item qxl
QXL paravirtual graphic card. It is VGA compatible (including VESA
2.0 VBE support). Works best with qxl guest drivers installed though.
Recommended choice when using the spice protocol.
@item tcx
(sun4m only) Sun TCX framebuffer. This is the default framebuffer for
sun4m machines and offers both 8-bit and 24-bit colour depths at a
fixed resolution of 1024x768.
@item cg3
(sun4m only) Sun cgthree framebuffer. This is a simple 8-bit framebuffer
for sun4m machines available in both 1024x768 (OpenBIOS) and 1152x900 (OBP)
resolutions aimed at people wishing to run older Solaris versions.
@item virtio
Virtio VGA card.
@item none
Disable VGA card.
@end table
ETEXI
DEF("full-screen", 0, QEMU_OPTION_full_screen,
"-full-screen start in full screen\n", QEMU_ARCH_ALL)
STEXI
@item -full-screen
@findex -full-screen
Start in full screen.
ETEXI
DEF("g", 1, QEMU_OPTION_g ,
"-g WxH[xDEPTH] Set the initial graphical resolution and depth\n",
QEMU_ARCH_PPC | QEMU_ARCH_SPARC)
STEXI
@item -g @var{width}x@var{height}[x@var{depth}]
@findex -g
Set the initial graphical resolution and depth (PPC, SPARC only).
ETEXI
DEF("vnc", HAS_ARG, QEMU_OPTION_vnc ,
"-vnc <display> shorthand for -display vnc=<display>\n", QEMU_ARCH_ALL)
STEXI
@item -vnc @var{display}[,@var{option}[,@var{option}[,...]]]
@findex -vnc
Normally, if QEMU is compiled with graphical window support, it displays
output such as guest graphics, guest console, and the QEMU monitor in a
window. With this option, you can have QEMU listen on VNC display
@var{display} and redirect the VGA display over the VNC session. It is
very useful to enable the usb tablet device when using this option
(option @option{-device usb-tablet}). When using the VNC display, you
must use the @option{-k} parameter to set the keyboard layout if you are
not using en-us. Valid syntax for the @var{display} is
@table @option
@item to=@var{L}
With this option, QEMU will try next available VNC @var{display}s, until the
number @var{L}, if the origianlly defined "-vnc @var{display}" is not
available, e.g. port 5900+@var{display} is already used by another
application. By default, to=0.
@item @var{host}:@var{d}
TCP connections will only be allowed from @var{host} on display @var{d}.
By convention the TCP port is 5900+@var{d}. Optionally, @var{host} can
be omitted in which case the server will accept connections from any host.
@item unix:@var{path}
Connections will be allowed over UNIX domain sockets where @var{path} is the
location of a unix socket to listen for connections on.
@item none
VNC is initialized but not started. The monitor @code{change} command
can be used to later start the VNC server.
@end table
Following the @var{display} value there may be one or more @var{option} flags
separated by commas. Valid options are
@table @option
@item reverse
Connect to a listening VNC client via a ``reverse'' connection. The
client is specified by the @var{display}. For reverse network
connections (@var{host}:@var{d},@code{reverse}), the @var{d} argument
is a TCP port number, not a display number.
@item websocket
Opens an additional TCP listening port dedicated to VNC Websocket connections.
If a bare @var{websocket} option is given, the Websocket port is
5700+@var{display}. An alternative port can be specified with the
syntax @code{websocket}=@var{port}.
If @var{host} is specified connections will only be allowed from this host.
It is possible to control the websocket listen address independently, using
the syntax @code{websocket}=@var{host}:@var{port}.
ui: convert VNC server to use QCryptoTLSSession Switch VNC server over to using the QCryptoTLSSession object for the TLS session. This removes the direct use of gnutls from the VNC server code. It also removes most knowledge about TLS certificate handling from the VNC server code. This has the nice effect that all the CONFIG_VNC_TLS conditionals go away and the user gets an actual error message when requesting TLS instead of it being silently ignored. With this change, the existing configuration options for enabling TLS with -vnc are deprecated. Old syntax for anon-DH credentials: -vnc hostname:0,tls New syntax: -object tls-creds-anon,id=tls0,endpoint=server \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, no client certs: -vnc hostname:0,tls,x509=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=no \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, requiring client certs: -vnc hostname:0,tls,x509verify=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=yes \ -vnc hostname:0,tls-creds=tls0 This aligns VNC with the way TLS credentials are to be configured in the future for chardev, nbd and migration backends. It also has the benefit that the same TLS credentials can be shared across multiple VNC server instances, if desired. If someone uses the deprecated syntax, it will internally result in the creation of a 'tls-creds' object with an ID based on the VNC server ID. This allows backwards compat with the CLI syntax, while still deleting all the original TLS code from the VNC server. Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2015-08-06 21:39:32 +08:00
If no TLS credentials are provided, the websocket connection runs in
unencrypted mode. If TLS credentials are provided, the websocket connection
requires encrypted client connections.
@item password
Require that password based authentication is used for client connections.
The password must be set separately using the @code{set_password} command in
the @ref{pcsys_monitor}. The syntax to change your password is:
@code{set_password <protocol> <password>} where <protocol> could be either
"vnc" or "spice".
If you would like to change <protocol> password expiration, you should use
@code{expire_password <protocol> <expiration-time>} where expiration time could
be one of the following options: now, never, +seconds or UNIX time of
expiration, e.g. +60 to make password expire in 60 seconds, or 1335196800
to make password expire on "Mon Apr 23 12:00:00 EDT 2012" (UNIX time for this
date and time).
You can also use keywords "now" or "never" for the expiration time to
allow <protocol> password to expire immediately or never expire.
ui: convert VNC server to use QCryptoTLSSession Switch VNC server over to using the QCryptoTLSSession object for the TLS session. This removes the direct use of gnutls from the VNC server code. It also removes most knowledge about TLS certificate handling from the VNC server code. This has the nice effect that all the CONFIG_VNC_TLS conditionals go away and the user gets an actual error message when requesting TLS instead of it being silently ignored. With this change, the existing configuration options for enabling TLS with -vnc are deprecated. Old syntax for anon-DH credentials: -vnc hostname:0,tls New syntax: -object tls-creds-anon,id=tls0,endpoint=server \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, no client certs: -vnc hostname:0,tls,x509=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=no \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, requiring client certs: -vnc hostname:0,tls,x509verify=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=yes \ -vnc hostname:0,tls-creds=tls0 This aligns VNC with the way TLS credentials are to be configured in the future for chardev, nbd and migration backends. It also has the benefit that the same TLS credentials can be shared across multiple VNC server instances, if desired. If someone uses the deprecated syntax, it will internally result in the creation of a 'tls-creds' object with an ID based on the VNC server ID. This allows backwards compat with the CLI syntax, while still deleting all the original TLS code from the VNC server. Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2015-08-06 21:39:32 +08:00
@item tls-creds=@var{ID}
Provides the ID of a set of TLS credentials to use to secure the
VNC server. They will apply to both the normal VNC server socket
and the websocket socket (if enabled). Setting TLS credentials
will cause the VNC server socket to enable the VeNCrypt auth
mechanism. The credentials should have been previously created
using the @option{-object tls-creds} argument.
The @option{tls-creds} parameter obsoletes the @option{tls},
@option{x509}, and @option{x509verify} options, and as such
it is not permitted to set both new and old type options at
the same time.
@item tls
Require that client use TLS when communicating with the VNC server. This
uses anonymous TLS credentials so is susceptible to a man-in-the-middle
attack. It is recommended that this option be combined with either the
@option{x509} or @option{x509verify} options.
ui: convert VNC server to use QCryptoTLSSession Switch VNC server over to using the QCryptoTLSSession object for the TLS session. This removes the direct use of gnutls from the VNC server code. It also removes most knowledge about TLS certificate handling from the VNC server code. This has the nice effect that all the CONFIG_VNC_TLS conditionals go away and the user gets an actual error message when requesting TLS instead of it being silently ignored. With this change, the existing configuration options for enabling TLS with -vnc are deprecated. Old syntax for anon-DH credentials: -vnc hostname:0,tls New syntax: -object tls-creds-anon,id=tls0,endpoint=server \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, no client certs: -vnc hostname:0,tls,x509=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=no \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, requiring client certs: -vnc hostname:0,tls,x509verify=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=yes \ -vnc hostname:0,tls-creds=tls0 This aligns VNC with the way TLS credentials are to be configured in the future for chardev, nbd and migration backends. It also has the benefit that the same TLS credentials can be shared across multiple VNC server instances, if desired. If someone uses the deprecated syntax, it will internally result in the creation of a 'tls-creds' object with an ID based on the VNC server ID. This allows backwards compat with the CLI syntax, while still deleting all the original TLS code from the VNC server. Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2015-08-06 21:39:32 +08:00
This option is now deprecated in favor of using the @option{tls-creds}
argument.
@item x509=@var{/path/to/certificate/dir}
Valid if @option{tls} is specified. Require that x509 credentials are used
for negotiating the TLS session. The server will send its x509 certificate
to the client. It is recommended that a password be set on the VNC server
to provide authentication of the client when this is used. The path following
this option specifies where the x509 certificates are to be loaded from.
See the @ref{vnc_security} section for details on generating certificates.
ui: convert VNC server to use QCryptoTLSSession Switch VNC server over to using the QCryptoTLSSession object for the TLS session. This removes the direct use of gnutls from the VNC server code. It also removes most knowledge about TLS certificate handling from the VNC server code. This has the nice effect that all the CONFIG_VNC_TLS conditionals go away and the user gets an actual error message when requesting TLS instead of it being silently ignored. With this change, the existing configuration options for enabling TLS with -vnc are deprecated. Old syntax for anon-DH credentials: -vnc hostname:0,tls New syntax: -object tls-creds-anon,id=tls0,endpoint=server \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, no client certs: -vnc hostname:0,tls,x509=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=no \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, requiring client certs: -vnc hostname:0,tls,x509verify=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=yes \ -vnc hostname:0,tls-creds=tls0 This aligns VNC with the way TLS credentials are to be configured in the future for chardev, nbd and migration backends. It also has the benefit that the same TLS credentials can be shared across multiple VNC server instances, if desired. If someone uses the deprecated syntax, it will internally result in the creation of a 'tls-creds' object with an ID based on the VNC server ID. This allows backwards compat with the CLI syntax, while still deleting all the original TLS code from the VNC server. Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2015-08-06 21:39:32 +08:00
This option is now deprecated in favour of using the @option{tls-creds}
argument.
@item x509verify=@var{/path/to/certificate/dir}
Valid if @option{tls} is specified. Require that x509 credentials are used
for negotiating the TLS session. The server will send its x509 certificate
to the client, and request that the client send its own x509 certificate.
The server will validate the client's certificate against the CA certificate,
and reject clients when validation fails. If the certificate authority is
trusted, this is a sufficient authentication mechanism. You may still wish
to set a password on the VNC server as a second authentication layer. The
path following this option specifies where the x509 certificates are to
be loaded from. See the @ref{vnc_security} section for details on generating
certificates.
ui: convert VNC server to use QCryptoTLSSession Switch VNC server over to using the QCryptoTLSSession object for the TLS session. This removes the direct use of gnutls from the VNC server code. It also removes most knowledge about TLS certificate handling from the VNC server code. This has the nice effect that all the CONFIG_VNC_TLS conditionals go away and the user gets an actual error message when requesting TLS instead of it being silently ignored. With this change, the existing configuration options for enabling TLS with -vnc are deprecated. Old syntax for anon-DH credentials: -vnc hostname:0,tls New syntax: -object tls-creds-anon,id=tls0,endpoint=server \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, no client certs: -vnc hostname:0,tls,x509=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=no \ -vnc hostname:0,tls-creds=tls0 Old syntax for x509 credentials, requiring client certs: -vnc hostname:0,tls,x509verify=/path/to/certs New syntax: -object tls-creds-x509,id=tls0,dir=/path/to/certs,endpoint=server,verify-peer=yes \ -vnc hostname:0,tls-creds=tls0 This aligns VNC with the way TLS credentials are to be configured in the future for chardev, nbd and migration backends. It also has the benefit that the same TLS credentials can be shared across multiple VNC server instances, if desired. If someone uses the deprecated syntax, it will internally result in the creation of a 'tls-creds' object with an ID based on the VNC server ID. This allows backwards compat with the CLI syntax, while still deleting all the original TLS code from the VNC server. Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2015-08-06 21:39:32 +08:00
This option is now deprecated in favour of using the @option{tls-creds}
argument.
@item sasl
Require that the client use SASL to authenticate with the VNC server.
The exact choice of authentication method used is controlled from the
system / user's SASL configuration file for the 'qemu' service. This
is typically found in /etc/sasl2/qemu.conf. If running QEMU as an
unprivileged user, an environment variable SASL_CONF_PATH can be used
to make it search alternate locations for the service config.
While some SASL auth methods can also provide data encryption (eg GSSAPI),
it is recommended that SASL always be combined with the 'tls' and
'x509' settings to enable use of SSL and server certificates. This
ensures a data encryption preventing compromise of authentication
credentials. See the @ref{vnc_security} section for details on using
SASL authentication.
@item acl
Turn on access control lists for checking of the x509 client certificate
and SASL party. For x509 certs, the ACL check is made against the
certificate's distinguished name. This is something that looks like
@code{C=GB,O=ACME,L=Boston,CN=bob}. For SASL party, the ACL check is
made against the username, which depending on the SASL plugin, may
include a realm component, eg @code{bob} or @code{bob@@EXAMPLE.COM}.
When the @option{acl} flag is set, the initial access list will be
empty, with a @code{deny} policy. Thus no one will be allowed to
use the VNC server until the ACLs have been loaded. This can be
achieved using the @code{acl} monitor command.
@item lossy
Enable lossy compression methods (gradient, JPEG, ...). If this
option is set, VNC client may receive lossy framebuffer updates
depending on its encoding settings. Enabling this option can save
a lot of bandwidth at the expense of quality.
@item non-adaptive
Disable adaptive encodings. Adaptive encodings are enabled by default.
An adaptive encoding will try to detect frequently updated screen regions,
and send updates in these regions using a lossy encoding (like JPEG).
This can be really helpful to save bandwidth when playing videos. Disabling
adaptive encodings restores the original static behavior of encodings
like Tight.
@item share=[allow-exclusive|force-shared|ignore]
Set display sharing policy. 'allow-exclusive' allows clients to ask
for exclusive access. As suggested by the rfb spec this is
implemented by dropping other connections. Connecting multiple
clients in parallel requires all clients asking for a shared session
(vncviewer: -shared switch). This is the default. 'force-shared'
disables exclusive client access. Useful for shared desktop sessions,
where you don't want someone forgetting specify -shared disconnect
everybody else. 'ignore' completely ignores the shared flag and
allows everybody connect unconditionally. Doesn't conform to the rfb
spec but is traditional QEMU behavior.
@item key-delay-ms
Set keyboard delay, for key down and key up events, in milliseconds.
Default is 10. Keyboards are low-bandwidth devices, so this slowdown
can help the device and guest to keep up and not lose events in case
events are arriving in bulk. Possible causes for the latter are flaky
network connections, or scripts for automated testing.
@end table
ETEXI
STEXI
@end table
ETEXI
ARCHHEADING(, QEMU_ARCH_I386)
ARCHHEADING(i386 target only:, QEMU_ARCH_I386)
STEXI
@table @option
ETEXI
DEF("win2k-hack", 0, QEMU_OPTION_win2k_hack,
"-win2k-hack use it when installing Windows 2000 to avoid a disk full bug\n",
QEMU_ARCH_I386)
STEXI
@item -win2k-hack
@findex -win2k-hack
Use it when installing Windows 2000 to avoid a disk full bug. After
Windows 2000 is installed, you no longer need this option (this option
slows down the IDE transfers).
ETEXI
HXCOMM Deprecated by -rtc
DEF("rtc-td-hack", 0, QEMU_OPTION_rtc_td_hack, "", QEMU_ARCH_I386)
DEF("no-fd-bootchk", 0, QEMU_OPTION_no_fd_bootchk,
"-no-fd-bootchk disable boot signature checking for floppy disks\n",
QEMU_ARCH_I386)
STEXI
@item -no-fd-bootchk
@findex -no-fd-bootchk
Disable boot signature checking for floppy disks in BIOS. May
be needed to boot from old floppy disks.
ETEXI
DEF("no-acpi", 0, QEMU_OPTION_no_acpi,
"-no-acpi disable ACPI\n", QEMU_ARCH_I386 | QEMU_ARCH_ARM)
STEXI
@item -no-acpi
@findex -no-acpi
Disable ACPI (Advanced Configuration and Power Interface) support. Use
it if your guest OS complains about ACPI problems (PC target machine
only).
ETEXI
DEF("no-hpet", 0, QEMU_OPTION_no_hpet,
"-no-hpet disable HPET\n", QEMU_ARCH_I386)
STEXI
@item -no-hpet
@findex -no-hpet
Disable HPET support.
ETEXI
DEF("acpitable", HAS_ARG, QEMU_OPTION_acpitable,
"-acpitable [sig=str][,rev=n][,oem_id=str][,oem_table_id=str][,oem_rev=n][,asl_compiler_id=str][,asl_compiler_rev=n][,{data|file}=file1[:file2]...]\n"
" ACPI table description\n", QEMU_ARCH_I386)
STEXI
@item -acpitable [sig=@var{str}][,rev=@var{n}][,oem_id=@var{str}][,oem_table_id=@var{str}][,oem_rev=@var{n}] [,asl_compiler_id=@var{str}][,asl_compiler_rev=@var{n}][,data=@var{file1}[:@var{file2}]...]
@findex -acpitable
Add ACPI table with specified header fields and context from specified files.
For file=, take whole ACPI table from the specified files, including all
ACPI headers (possible overridden by other options).
For data=, only data
portion of the table is used, all header information is specified in the
command line.
If a SLIC table is supplied to QEMU, then the SLIC's oem_id and oem_table_id
fields will override the same in the RSDT and the FADT (a.k.a. FACP), in order
to ensure the field matches required by the Microsoft SLIC spec and the ACPI
spec.
ETEXI
DEF("smbios", HAS_ARG, QEMU_OPTION_smbios,
"-smbios file=binary\n"
" load SMBIOS entry from binary file\n"
"-smbios type=0[,vendor=str][,version=str][,date=str][,release=%d.%d]\n"
" [,uefi=on|off]\n"
" specify SMBIOS type 0 fields\n"
"-smbios type=1[,manufacturer=str][,product=str][,version=str][,serial=str]\n"
" [,uuid=uuid][,sku=str][,family=str]\n"
" specify SMBIOS type 1 fields\n"
"-smbios type=2[,manufacturer=str][,product=str][,version=str][,serial=str]\n"
" [,asset=str][,location=str]\n"
" specify SMBIOS type 2 fields\n"
"-smbios type=3[,manufacturer=str][,version=str][,serial=str][,asset=str]\n"
" [,sku=str]\n"
" specify SMBIOS type 3 fields\n"
"-smbios type=4[,sock_pfx=str][,manufacturer=str][,version=str][,serial=str]\n"
" [,asset=str][,part=str]\n"
" specify SMBIOS type 4 fields\n"
"-smbios type=17[,loc_pfx=str][,bank=str][,manufacturer=str][,serial=str]\n"
" [,asset=str][,part=str][,speed=%d]\n"
" specify SMBIOS type 17 fields\n",
QEMU_ARCH_I386 | QEMU_ARCH_ARM)
STEXI
@item -smbios file=@var{binary}
@findex -smbios
Load SMBIOS entry from binary file.
@item -smbios type=0[,vendor=@var{str}][,version=@var{str}][,date=@var{str}][,release=@var{%d.%d}][,uefi=on|off]
Specify SMBIOS type 0 fields
@item -smbios type=1[,manufacturer=@var{str}][,product=@var{str}][,version=@var{str}][,serial=@var{str}][,uuid=@var{uuid}][,sku=@var{str}][,family=@var{str}]
Specify SMBIOS type 1 fields
@item -smbios type=2[,manufacturer=@var{str}][,product=@var{str}][,version=@var{str}][,serial=@var{str}][,asset=@var{str}][,location=@var{str}][,family=@var{str}]
Specify SMBIOS type 2 fields
@item -smbios type=3[,manufacturer=@var{str}][,version=@var{str}][,serial=@var{str}][,asset=@var{str}][,sku=@var{str}]
Specify SMBIOS type 3 fields
@item -smbios type=4[,sock_pfx=@var{str}][,manufacturer=@var{str}][,version=@var{str}][,serial=@var{str}][,asset=@var{str}][,part=@var{str}]
Specify SMBIOS type 4 fields
@item -smbios type=17[,loc_pfx=@var{str}][,bank=@var{str}][,manufacturer=@var{str}][,serial=@var{str}][,asset=@var{str}][,part=@var{str}][,speed=@var{%d}]
Specify SMBIOS type 17 fields
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
DEFHEADING(Network options:)
STEXI
@table @option
ETEXI
HXCOMM Legacy slirp options (now moved to -net user):
#ifdef CONFIG_SLIRP
DEF("tftp", HAS_ARG, QEMU_OPTION_tftp, "", QEMU_ARCH_ALL)
DEF("bootp", HAS_ARG, QEMU_OPTION_bootp, "", QEMU_ARCH_ALL)
DEF("redir", HAS_ARG, QEMU_OPTION_redir, "", QEMU_ARCH_ALL)
#ifndef _WIN32
DEF("smb", HAS_ARG, QEMU_OPTION_smb, "", QEMU_ARCH_ALL)
#endif
#endif
DEF("netdev", HAS_ARG, QEMU_OPTION_netdev,
#ifdef CONFIG_SLIRP
"-netdev user,id=str[,ipv4[=on|off]][,net=addr[/mask]][,host=addr]\n"
" [,ipv6[=on|off]][,ipv6-net=addr[/int]][,ipv6-host=addr]\n"
" [,restrict=on|off][,hostname=host][,dhcpstart=addr]\n"
" [,dns=addr][,ipv6-dns=addr][,dnssearch=domain][,tftp=dir]\n"
" [,bootfile=f][,hostfwd=rule][,guestfwd=rule]"
#ifndef _WIN32
"[,smb=dir[,smbserver=addr]]\n"
#endif
" configure a user mode network backend with ID 'str',\n"
" its DHCP server and optional services\n"
#endif
#ifdef _WIN32
"-netdev tap,id=str,ifname=name\n"
" configure a host TAP network backend with ID 'str'\n"
#else
"-netdev tap,id=str[,fd=h][,fds=x:y:...:z][,ifname=name][,script=file][,downscript=dfile]\n"
" [,br=bridge][,helper=helper][,sndbuf=nbytes][,vnet_hdr=on|off][,vhost=on|off]\n"
" [,vhostfd=h][,vhostfds=x:y:...:z][,vhostforce=on|off][,queues=n]\n"
" [,poll-us=n]\n"
" configure a host TAP network backend with ID 'str'\n"
" connected to a bridge (default=" DEFAULT_BRIDGE_INTERFACE ")\n"
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
" use network scripts 'file' (default=" DEFAULT_NETWORK_SCRIPT ")\n"
" to configure it and 'dfile' (default=" DEFAULT_NETWORK_DOWN_SCRIPT ")\n"
" to deconfigure it\n"
" use '[down]script=no' to disable script execution\n"
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
" use network helper 'helper' (default=" DEFAULT_BRIDGE_HELPER ") to\n"
" configure it\n"
" use 'fd=h' to connect to an already opened TAP interface\n"
" use 'fds=x:y:...:z' to connect to already opened multiqueue capable TAP interfaces\n"
" use 'sndbuf=nbytes' to limit the size of the send buffer (the\n"
" default is disabled 'sndbuf=0' to enable flow control set 'sndbuf=1048576')\n"
" use vnet_hdr=off to avoid enabling the IFF_VNET_HDR tap flag\n"
" use vnet_hdr=on to make the lack of IFF_VNET_HDR support an error condition\n"
" use vhost=on to enable experimental in kernel accelerator\n"
" (only has effect for virtio guests which use MSIX)\n"
" use vhostforce=on to force vhost on for non-MSIX virtio guests\n"
" use 'vhostfd=h' to connect to an already opened vhost net device\n"
" use 'vhostfds=x:y:...:z to connect to multiple already opened vhost net devices\n"
" use 'queues=n' to specify the number of queues to be created for multiqueue TAP\n"
" use 'poll-us=n' to speciy the maximum number of microseconds that could be\n"
" spent on busy polling for vhost net\n"
"-netdev bridge,id=str[,br=bridge][,helper=helper]\n"
" configure a host TAP network backend with ID 'str' that is\n"
" connected to a bridge (default=" DEFAULT_BRIDGE_INTERFACE ")\n"
" using the program 'helper (default=" DEFAULT_BRIDGE_HELPER ")\n"
#endif
#ifdef __linux__
"-netdev l2tpv3,id=str,src=srcaddr,dst=dstaddr[,srcport=srcport][,dstport=dstport]\n"
" [,rxsession=rxsession],txsession=txsession[,ipv6=on/off][,udp=on/off]\n"
" [,cookie64=on/off][,counter][,pincounter][,txcookie=txcookie]\n"
" [,rxcookie=rxcookie][,offset=offset]\n"
" configure a network backend with ID 'str' connected to\n"
" an Ethernet over L2TPv3 pseudowire.\n"
" Linux kernel 3.3+ as well as most routers can talk\n"
" L2TPv3. This transport allows connecting a VM to a VM,\n"
" VM to a router and even VM to Host. It is a nearly-universal\n"
" standard (RFC3391). Note - this implementation uses static\n"
" pre-configured tunnels (same as the Linux kernel).\n"
" use 'src=' to specify source address\n"
" use 'dst=' to specify destination address\n"
" use 'udp=on' to specify udp encapsulation\n"
" use 'srcport=' to specify source udp port\n"
" use 'dstport=' to specify destination udp port\n"
" use 'ipv6=on' to force v6\n"
" L2TPv3 uses cookies to prevent misconfiguration as\n"
" well as a weak security measure\n"
" use 'rxcookie=0x012345678' to specify a rxcookie\n"
" use 'txcookie=0x012345678' to specify a txcookie\n"
" use 'cookie64=on' to set cookie size to 64 bit, otherwise 32\n"
" use 'counter=off' to force a 'cut-down' L2TPv3 with no counter\n"
" use 'pincounter=on' to work around broken counter handling in peer\n"
" use 'offset=X' to add an extra offset between header and data\n"
#endif
"-netdev socket,id=str[,fd=h][,listen=[host]:port][,connect=host:port]\n"
" configure a network backend to connect to another network\n"
" using a socket connection\n"
"-netdev socket,id=str[,fd=h][,mcast=maddr:port[,localaddr=addr]]\n"
" configure a network backend to connect to a multicast maddr and port\n"
" use 'localaddr=addr' to specify the host address to send packets from\n"
"-netdev socket,id=str[,fd=h][,udp=host:port][,localaddr=host:port]\n"
" configure a network backend to connect to another network\n"
" using an UDP tunnel\n"
#ifdef CONFIG_VDE
"-netdev vde,id=str[,sock=socketpath][,port=n][,group=groupname][,mode=octalmode]\n"
" configure a network backend to connect to port 'n' of a vde switch\n"
" running on host and listening for incoming connections on 'socketpath'.\n"
" Use group 'groupname' and mode 'octalmode' to change default\n"
" ownership and permissions for communication port.\n"
#endif
#ifdef CONFIG_NETMAP
"-netdev netmap,id=str,ifname=name[,devname=nmname]\n"
" attach to the existing netmap-enabled network interface 'name', or to a\n"
" VALE port (created on the fly) called 'name' ('nmname' is name of the \n"
" netmap device, defaults to '/dev/netmap')\n"
#endif
"-netdev vhost-user,id=str,chardev=dev[,vhostforce=on|off]\n"
" configure a vhost-user network, backed by a chardev 'dev'\n"
"-netdev hubport,id=str,hubid=n\n"
" configure a hub port on QEMU VLAN 'n'\n", QEMU_ARCH_ALL)
DEF("net", HAS_ARG, QEMU_OPTION_net,
"-net nic[,vlan=n][,macaddr=mac][,model=type][,name=str][,addr=str][,vectors=v]\n"
" old way to create a new NIC and connect it to VLAN 'n'\n"
" (use the '-device devtype,netdev=str' option if possible instead)\n"
"-net dump[,vlan=n][,file=f][,len=n]\n"
" dump traffic on vlan 'n' to file 'f' (max n bytes per packet)\n"
"-net none use it alone to have zero network devices. If no -net option\n"
" is provided, the default is '-net nic -net user'\n"
"-net ["
#ifdef CONFIG_SLIRP
"user|"
#endif
"tap|"
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
"bridge|"
#ifdef CONFIG_VDE
"vde|"
#endif
#ifdef CONFIG_NETMAP
"netmap|"
#endif
"socket][,vlan=n][,option][,option][,...]\n"
" old way to initialize a host network interface\n"
" (use the -netdev option if possible instead)\n", QEMU_ARCH_ALL)
STEXI
@item -net nic[,vlan=@var{n}][,macaddr=@var{mac}][,model=@var{type}] [,name=@var{name}][,addr=@var{addr}][,vectors=@var{v}]
@findex -net
Create a new Network Interface Card and connect it to VLAN @var{n} (@var{n}
= 0 is the default). The NIC is an e1000 by default on the PC
target. Optionally, the MAC address can be changed to @var{mac}, the
device address set to @var{addr} (PCI cards only),
and a @var{name} can be assigned for use in monitor commands.
Optionally, for PCI cards, you can specify the number @var{v} of MSI-X vectors
that the card should have; this option currently only affects virtio cards; set
@var{v} = 0 to disable MSI-X. If no @option{-net} option is specified, a single
NIC is created. QEMU can emulate several different models of network card.
Valid values for @var{type} are
@code{virtio}, @code{i82551}, @code{i82557b}, @code{i82559er},
@code{ne2k_pci}, @code{ne2k_isa}, @code{pcnet}, @code{rtl8139},
@code{e1000}, @code{smc91c111}, @code{lance} and @code{mcf_fec}.
Not all devices are supported on all targets. Use @code{-net nic,model=help}
for a list of available devices for your target.
@item -netdev user,id=@var{id}[,@var{option}][,@var{option}][,...]
@findex -netdev
@item -net user[,@var{option}][,@var{option}][,...]
Use the user mode network stack which requires no administrator
privilege to run. Valid options are:
@table @option
@item vlan=@var{n}
Connect user mode stack to VLAN @var{n} (@var{n} = 0 is the default).
@item id=@var{id}
@itemx name=@var{name}
Assign symbolic name for use in monitor commands.
@option{ipv4} and @option{ipv6} specify that either IPv4 or IPv6 must
be enabled. If neither is specified both protocols are enabled.
@item net=@var{addr}[/@var{mask}]
Set IP network address the guest will see. Optionally specify the netmask,
either in the form a.b.c.d or as number of valid top-most bits. Default is
10.0.2.0/24.
@item host=@var{addr}
Specify the guest-visible address of the host. Default is the 2nd IP in the
guest network, i.e. x.x.x.2.
@item ipv6-net=@var{addr}[/@var{int}]
Set IPv6 network address the guest will see (default is fec0::/64). The
network prefix is given in the usual hexadecimal IPv6 address
notation. The prefix size is optional, and is given as the number of
valid top-most bits (default is 64).
@item ipv6-host=@var{addr}
Specify the guest-visible IPv6 address of the host. Default is the 2nd IPv6 in
the guest network, i.e. xxxx::2.
@item restrict=on|off
If this option is enabled, the guest will be isolated, i.e. it will not be
able to contact the host and no guest IP packets will be routed over the host
to the outside. This option does not affect any explicitly set forwarding rules.
@item hostname=@var{name}
Specifies the client hostname reported by the built-in DHCP server.
@item dhcpstart=@var{addr}
Specify the first of the 16 IPs the built-in DHCP server can assign. Default
is the 15th to 31st IP in the guest network, i.e. x.x.x.15 to x.x.x.31.
@item dns=@var{addr}
Specify the guest-visible address of the virtual nameserver. The address must
be different from the host address. Default is the 3rd IP in the guest network,
i.e. x.x.x.3.
@item ipv6-dns=@var{addr}
Specify the guest-visible address of the IPv6 virtual nameserver. The address
must be different from the host address. Default is the 3rd IP in the guest
network, i.e. xxxx::3.
@item dnssearch=@var{domain}
Provides an entry for the domain-search list sent by the built-in
DHCP server. More than one domain suffix can be transmitted by specifying
this option multiple times. If supported, this will cause the guest to
automatically try to append the given domain suffix(es) in case a domain name
can not be resolved.
Example:
@example
qemu -net user,dnssearch=mgmt.example.org,dnssearch=example.org [...]
@end example
@item tftp=@var{dir}
When using the user mode network stack, activate a built-in TFTP
server. The files in @var{dir} will be exposed as the root of a TFTP server.
The TFTP client on the guest must be configured in binary mode (use the command
@code{bin} of the Unix TFTP client).
@item bootfile=@var{file}
When using the user mode network stack, broadcast @var{file} as the BOOTP
filename. In conjunction with @option{tftp}, this can be used to network boot
a guest from a local directory.
Example (using pxelinux):
@example
qemu-system-i386 -hda linux.img -boot n -net user,tftp=/path/to/tftp/files,bootfile=/pxelinux.0
@end example
@item smb=@var{dir}[,smbserver=@var{addr}]
When using the user mode network stack, activate a built-in SMB
server so that Windows OSes can access to the host files in @file{@var{dir}}
transparently. The IP address of the SMB server can be set to @var{addr}. By
default the 4th IP in the guest network is used, i.e. x.x.x.4.
In the guest Windows OS, the line:
@example
10.0.2.4 smbserver
@end example
must be added in the file @file{C:\WINDOWS\LMHOSTS} (for windows 9x/Me)
or @file{C:\WINNT\SYSTEM32\DRIVERS\ETC\LMHOSTS} (Windows NT/2000).
Then @file{@var{dir}} can be accessed in @file{\\smbserver\qemu}.
Note that a SAMBA server must be installed on the host OS.
QEMU was tested successfully with smbd versions from Red Hat 9,
Fedora Core 3 and OpenSUSE 11.x.
@item hostfwd=[tcp|udp]:[@var{hostaddr}]:@var{hostport}-[@var{guestaddr}]:@var{guestport}
Redirect incoming TCP or UDP connections to the host port @var{hostport} to
the guest IP address @var{guestaddr} on guest port @var{guestport}. If
@var{guestaddr} is not specified, its value is x.x.x.15 (default first address
given by the built-in DHCP server). By specifying @var{hostaddr}, the rule can
be bound to a specific host interface. If no connection type is set, TCP is
used. This option can be given multiple times.
For example, to redirect host X11 connection from screen 1 to guest
screen 0, use the following:
@example
# on the host
qemu-system-i386 -net user,hostfwd=tcp:127.0.0.1:6001-:6000 [...]
# this host xterm should open in the guest X11 server
xterm -display :1
@end example
To redirect telnet connections from host port 5555 to telnet port on
the guest, use the following:
@example
# on the host
qemu-system-i386 -net user,hostfwd=tcp::5555-:23 [...]
telnet localhost 5555
@end example
Then when you use on the host @code{telnet localhost 5555}, you
connect to the guest telnet server.
@item guestfwd=[tcp]:@var{server}:@var{port}-@var{dev}
@itemx guestfwd=[tcp]:@var{server}:@var{port}-@var{cmd:command}
Forward guest TCP connections to the IP address @var{server} on port @var{port}
to the character device @var{dev} or to a program executed by @var{cmd:command}
which gets spawned for each connection. This option can be given multiple times.
You can either use a chardev directly and have that one used throughout QEMU's
lifetime, like in the following example:
@example
# open 10.10.1.1:4321 on bootup, connect 10.0.2.100:1234 to it whenever
# the guest accesses it
qemu -net user,guestfwd=tcp:10.0.2.100:1234-tcp:10.10.1.1:4321 [...]
@end example
Or you can execute a command on every TCP connection established by the guest,
so that QEMU behaves similar to an inetd process for that virtual server:
@example
# call "netcat 10.10.1.1 4321" on every TCP connection to 10.0.2.100:1234
# and connect the TCP stream to its stdin/stdout
qemu -net 'user,guestfwd=tcp:10.0.2.100:1234-cmd:netcat 10.10.1.1 4321'
@end example
@end table
Note: Legacy stand-alone options -tftp, -bootp, -smb and -redir are still
processed and applied to -net user. Mixing them with the new configuration
syntax gives undefined results. Their use for new applications is discouraged
as they will be removed from future versions.
@item -netdev tap,id=@var{id}[,fd=@var{h}][,ifname=@var{name}][,script=@var{file}][,downscript=@var{dfile}][,br=@var{bridge}][,helper=@var{helper}]
@itemx -net tap[,vlan=@var{n}][,name=@var{name}][,fd=@var{h}][,ifname=@var{name}][,script=@var{file}][,downscript=@var{dfile}][,br=@var{bridge}][,helper=@var{helper}]
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
Connect the host TAP network interface @var{name} to VLAN @var{n}.
Use the network script @var{file} to configure it and the network script
@var{dfile} to deconfigure it. If @var{name} is not provided, the OS
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
automatically provides one. The default network configure script is
@file{/etc/qemu-ifup} and the default network deconfigure script is
@file{/etc/qemu-ifdown}. Use @option{script=no} or @option{downscript=no}
to disable script execution.
If running QEMU as an unprivileged user, use the network helper
@var{helper} to configure the TAP interface and attach it to the bridge.
The default network helper executable is @file{/path/to/qemu-bridge-helper}
and the default bridge device is @file{br0}.
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
@option{fd}=@var{h} can be used to specify the handle of an already
opened host TAP interface.
Examples:
@example
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
#launch a QEMU instance with the default network script
qemu-system-i386 linux.img -net nic -net tap
@end example
@example
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
#launch a QEMU instance with two NICs, each one connected
#to a TAP device
qemu-system-i386 linux.img \
-net nic,vlan=0 -net tap,vlan=0,ifname=tap0 \
-net nic,vlan=1 -net tap,vlan=1,ifname=tap1
@end example
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
@example
#launch a QEMU instance with the default network helper to
#connect a TAP device to bridge br0
qemu-system-i386 linux.img \
-net nic -net tap,"helper=/path/to/qemu-bridge-helper"
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
@end example
@item -netdev bridge,id=@var{id}[,br=@var{bridge}][,helper=@var{helper}]
@itemx -net bridge[,vlan=@var{n}][,name=@var{name}][,br=@var{bridge}][,helper=@var{helper}]
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
Connect a host TAP network interface to a host bridge device.
Use the network helper @var{helper} to configure the TAP interface and
attach it to the bridge. The default network helper executable is
@file{/path/to/qemu-bridge-helper} and the default bridge
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
device is @file{br0}.
Examples:
@example
#launch a QEMU instance with the default network helper to
#connect a TAP device to bridge br0
qemu-system-i386 linux.img -net bridge -net nic,model=virtio
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
@end example
@example
#launch a QEMU instance with the default network helper to
#connect a TAP device to bridge qemubr0
qemu-system-i386 linux.img -net bridge,br=qemubr0 -net nic,model=virtio
Add support for net bridge The most common use of -net tap is to connect a tap device to a bridge. This requires the use of a script and running qemu as root in order to allocate a tap device to pass to the script. This model is great for portability and flexibility but it's incredibly difficult to eliminate the need to run qemu as root. The only really viable mechanism is to use tunctl to create a tap device, attach it to a bridge as root, and then hand that tap device to qemu. The problem with this mechanism is that it requires administrator intervention whenever a user wants to create a guest. By essentially writing a helper that implements the most common qemu-ifup script that can be safely given cap_net_admin, we can dramatically simplify things for non-privileged users. We still support existing -net tap options as a mechanism for advanced users and backwards compatibility. Currently, this is very Linux centric but there's really no reason why it couldn't be extended for other Unixes. A typical invocation would be similar to one of the following: qemu linux.img -net bridge -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper" -net nic,model=virtio qemu linux.img -netdev bridge,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 The default bridge that we attach to is br0. The thinking is that a distro could preconfigure such an interface to allow out-of-the-box bridged networking. Alternatively, if a user wants to use a different bridge, a typical invocation would be simliar to one of the following: qemu linux.img -net bridge,br=qemubr0 -net nic,model=virtio qemu linux.img -net tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0" -net nic,model=virtio qemu linux.img -netdev bridge,br=qemubr0,id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 qemu linux.img -netdev tap,helper="/usr/local/libexec/qemu-bridge-helper --br=qemubr0",id=hn0 -device virtio-net-pci,netdev=hn0,id=nic1 Signed-off-by: Anthony Liguori <aliguori@us.ibm.com> Signed-off-by: Richa Marwaha <rmarwah@linux.vnet.ibm.com> Signed-off-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2012-01-26 22:42:27 +08:00
@end example
@item -netdev socket,id=@var{id}[,fd=@var{h}][,listen=[@var{host}]:@var{port}][,connect=@var{host}:@var{port}]
@itemx -net socket[,vlan=@var{n}][,name=@var{name}][,fd=@var{h}] [,listen=[@var{host}]:@var{port}][,connect=@var{host}:@var{port}]
Connect the VLAN @var{n} to a remote VLAN in another QEMU virtual
machine using a TCP socket connection. If @option{listen} is
specified, QEMU waits for incoming connections on @var{port}
(@var{host} is optional). @option{connect} is used to connect to
another QEMU instance using the @option{listen} option. @option{fd}=@var{h}
specifies an already opened TCP socket.
Example:
@example
# launch a first QEMU instance
qemu-system-i386 linux.img \
-net nic,macaddr=52:54:00:12:34:56 \
-net socket,listen=:1234
# connect the VLAN 0 of this instance to the VLAN 0
# of the first instance
qemu-system-i386 linux.img \
-net nic,macaddr=52:54:00:12:34:57 \
-net socket,connect=127.0.0.1:1234
@end example
@item -netdev socket,id=@var{id}[,fd=@var{h}][,mcast=@var{maddr}:@var{port}[,localaddr=@var{addr}]]
@itemx -net socket[,vlan=@var{n}][,name=@var{name}][,fd=@var{h}][,mcast=@var{maddr}:@var{port}[,localaddr=@var{addr}]]
Create a VLAN @var{n} shared with another QEMU virtual
machines using a UDP multicast socket, effectively making a bus for
every QEMU with same multicast address @var{maddr} and @var{port}.
NOTES:
@enumerate
@item
Several QEMU can be running on different hosts and share same bus (assuming
correct multicast setup for these hosts).
@item
mcast support is compatible with User Mode Linux (argument @option{eth@var{N}=mcast}), see
@url{http://user-mode-linux.sf.net}.
@item
Use @option{fd=h} to specify an already opened UDP multicast socket.
@end enumerate
Example:
@example
# launch one QEMU instance
qemu-system-i386 linux.img \
-net nic,macaddr=52:54:00:12:34:56 \
-net socket,mcast=230.0.0.1:1234
# launch another QEMU instance on same "bus"
qemu-system-i386 linux.img \
-net nic,macaddr=52:54:00:12:34:57 \
-net socket,mcast=230.0.0.1:1234
# launch yet another QEMU instance on same "bus"
qemu-system-i386 linux.img \
-net nic,macaddr=52:54:00:12:34:58 \
-net socket,mcast=230.0.0.1:1234
@end example
Example (User Mode Linux compat.):
@example
# launch QEMU instance (note mcast address selected
# is UML's default)
qemu-system-i386 linux.img \
-net nic,macaddr=52:54:00:12:34:56 \
-net socket,mcast=239.192.168.1:1102
# launch UML
/path/to/linux ubd0=/path/to/root_fs eth0=mcast
@end example
Example (send packets from host's 1.2.3.4):
@example
qemu-system-i386 linux.img \
-net nic,macaddr=52:54:00:12:34:56 \
-net socket,mcast=239.192.168.1:1102,localaddr=1.2.3.4
@end example
@item -netdev l2tpv3,id=@var{id},src=@var{srcaddr},dst=@var{dstaddr}[,srcport=@var{srcport}][,dstport=@var{dstport}],txsession=@var{txsession}[,rxsession=@var{rxsession}][,ipv6][,udp][,cookie64][,counter][,pincounter][,txcookie=@var{txcookie}][,rxcookie=@var{rxcookie}][,offset=@var{offset}]
@itemx -net l2tpv3[,vlan=@var{n}][,name=@var{name}],src=@var{srcaddr},dst=@var{dstaddr}[,srcport=@var{srcport}][,dstport=@var{dstport}],txsession=@var{txsession}[,rxsession=@var{rxsession}][,ipv6][,udp][,cookie64][,counter][,pincounter][,txcookie=@var{txcookie}][,rxcookie=@var{rxcookie}][,offset=@var{offset}]
Connect VLAN @var{n} to L2TPv3 pseudowire. L2TPv3 (RFC3391) is a popular
protocol to transport Ethernet (and other Layer 2) data frames between
two systems. It is present in routers, firewalls and the Linux kernel
(from version 3.3 onwards).
This transport allows a VM to communicate to another VM, router or firewall directly.
@table @option
@item src=@var{srcaddr}
source address (mandatory)
@item dst=@var{dstaddr}
destination address (mandatory)
@item udp
select udp encapsulation (default is ip).
@item srcport=@var{srcport}
source udp port.
@item dstport=@var{dstport}
destination udp port.
@item ipv6
force v6, otherwise defaults to v4.
@item rxcookie=@var{rxcookie}
@itemx txcookie=@var{txcookie}
Cookies are a weak form of security in the l2tpv3 specification.
Their function is mostly to prevent misconfiguration. By default they are 32
bit.
@item cookie64
Set cookie size to 64 bit instead of the default 32
@item counter=off
Force a 'cut-down' L2TPv3 with no counter as in
draft-mkonstan-l2tpext-keyed-ipv6-tunnel-00
@item pincounter=on
Work around broken counter handling in peer. This may also help on
networks which have packet reorder.
@item offset=@var{offset}
Add an extra offset between header and data
@end table
For example, to attach a VM running on host 4.3.2.1 via L2TPv3 to the bridge br-lan
on the remote Linux host 1.2.3.4:
@example
# Setup tunnel on linux host using raw ip as encapsulation
# on 1.2.3.4
ip l2tp add tunnel remote 4.3.2.1 local 1.2.3.4 tunnel_id 1 peer_tunnel_id 1 \
encap udp udp_sport 16384 udp_dport 16384
ip l2tp add session tunnel_id 1 name vmtunnel0 session_id \
0xFFFFFFFF peer_session_id 0xFFFFFFFF
ifconfig vmtunnel0 mtu 1500
ifconfig vmtunnel0 up
brctl addif br-lan vmtunnel0
# on 4.3.2.1
# launch QEMU instance - if your network has reorder or is very lossy add ,pincounter
qemu-system-i386 linux.img -net nic -net l2tpv3,src=4.2.3.1,dst=1.2.3.4,udp,srcport=16384,dstport=16384,rxsession=0xffffffff,txsession=0xffffffff,counter
@end example
@item -netdev vde,id=@var{id}[,sock=@var{socketpath}][,port=@var{n}][,group=@var{groupname}][,mode=@var{octalmode}]
@itemx -net vde[,vlan=@var{n}][,name=@var{name}][,sock=@var{socketpath}] [,port=@var{n}][,group=@var{groupname}][,mode=@var{octalmode}]
Connect VLAN @var{n} to PORT @var{n} of a vde switch running on host and
listening for incoming connections on @var{socketpath}. Use GROUP @var{groupname}
and MODE @var{octalmode} to change default ownership and permissions for
communication port. This option is only available if QEMU has been compiled
with vde support enabled.
Example:
@example
# launch vde switch
vde_switch -F -sock /tmp/myswitch
# launch QEMU instance
qemu-system-i386 linux.img -net nic -net vde,sock=/tmp/myswitch
@end example
@item -netdev hubport,id=@var{id},hubid=@var{hubid}
Create a hub port on QEMU "vlan" @var{hubid}.
The hubport netdev lets you connect a NIC to a QEMU "vlan" instead of a single
netdev. @code{-net} and @code{-device} with parameter @option{vlan} create the
required hub automatically.
vhost-user: add multiple queue support This patch is initially based a patch from Nikolay Nikolaev. This patch adds vhost-user multiple queue support, by creating a nc and vhost_net pair for each queue. Qemu exits if find that the backend can't support the number of requested queues (by providing queues=# option). The max number is queried by a new message, VHOST_USER_GET_QUEUE_NUM, and is sent only when protocol feature VHOST_USER_PROTOCOL_F_MQ is present first. The max queue check is done at vhost-user initiation stage. We initiate one queue first, which, in the meantime, also gets the max_queues the backend supports. In older version, it was reported that some messages are sent more times than necessary. Here we came an agreement with Michael that we could categorize vhost user messages to 2 types: non-vring specific messages, which should be sent only once, and vring specific messages, which should be sent per queue. Here I introduced a helper function vhost_user_one_time_request(), which lists following messages as non-vring specific messages: VHOST_USER_SET_OWNER VHOST_USER_RESET_DEVICE VHOST_USER_SET_MEM_TABLE VHOST_USER_GET_QUEUE_NUM For above messages, we simply ignore them when they are not sent the first time. Signed-off-by: Nikolay Nikolaev <n.nikolaev@virtualopensystems.com> Signed-off-by: Changchun Ouyang <changchun.ouyang@intel.com> Signed-off-by: Yuanhan Liu <yuanhan.liu@linux.intel.com> Reviewed-by: Michael S. Tsirkin <mst@redhat.com> Signed-off-by: Michael S. Tsirkin <mst@redhat.com> Signed-off-by: Yuanhan Liu <yuanhan.liu@linux.intel.com> Reviewed-by: Jason Wang <jasowang@redhat.com> Tested-by: Marcel Apfelbaum <marcel@redhat.com>
2015-09-23 12:20:00 +08:00
@item -netdev vhost-user,chardev=@var{id}[,vhostforce=on|off][,queues=n]
Establish a vhost-user netdev, backed by a chardev @var{id}. The chardev should
be a unix domain socket backed one. The vhost-user uses a specifically defined
protocol to pass vhost ioctl replacement messages to an application on the other
end of the socket. On non-MSIX guests, the feature can be forced with
vhost-user: add multiple queue support This patch is initially based a patch from Nikolay Nikolaev. This patch adds vhost-user multiple queue support, by creating a nc and vhost_net pair for each queue. Qemu exits if find that the backend can't support the number of requested queues (by providing queues=# option). The max number is queried by a new message, VHOST_USER_GET_QUEUE_NUM, and is sent only when protocol feature VHOST_USER_PROTOCOL_F_MQ is present first. The max queue check is done at vhost-user initiation stage. We initiate one queue first, which, in the meantime, also gets the max_queues the backend supports. In older version, it was reported that some messages are sent more times than necessary. Here we came an agreement with Michael that we could categorize vhost user messages to 2 types: non-vring specific messages, which should be sent only once, and vring specific messages, which should be sent per queue. Here I introduced a helper function vhost_user_one_time_request(), which lists following messages as non-vring specific messages: VHOST_USER_SET_OWNER VHOST_USER_RESET_DEVICE VHOST_USER_SET_MEM_TABLE VHOST_USER_GET_QUEUE_NUM For above messages, we simply ignore them when they are not sent the first time. Signed-off-by: Nikolay Nikolaev <n.nikolaev@virtualopensystems.com> Signed-off-by: Changchun Ouyang <changchun.ouyang@intel.com> Signed-off-by: Yuanhan Liu <yuanhan.liu@linux.intel.com> Reviewed-by: Michael S. Tsirkin <mst@redhat.com> Signed-off-by: Michael S. Tsirkin <mst@redhat.com> Signed-off-by: Yuanhan Liu <yuanhan.liu@linux.intel.com> Reviewed-by: Jason Wang <jasowang@redhat.com> Tested-by: Marcel Apfelbaum <marcel@redhat.com>
2015-09-23 12:20:00 +08:00
@var{vhostforce}. Use 'queues=@var{n}' to specify the number of queues to
be created for multiqueue vhost-user.
Example:
@example
qemu -m 512 -object memory-backend-file,id=mem,size=512M,mem-path=/hugetlbfs,share=on \
-numa node,memdev=mem \
-chardev socket,id=chr0,path=/path/to/socket \
-netdev type=vhost-user,id=net0,chardev=chr0 \
-device virtio-net-pci,netdev=net0
@end example
@item -net dump[,vlan=@var{n}][,file=@var{file}][,len=@var{len}]
Dump network traffic on VLAN @var{n} to file @var{file} (@file{qemu-vlan0.pcap} by default).
At most @var{len} bytes (64k by default) per packet are stored. The file format is
libpcap, so it can be analyzed with tools such as tcpdump or Wireshark.
Note: For devices created with '-netdev', use '-object filter-dump,...' instead.
@item -net none
Indicate that no network devices should be configured. It is used to
override the default configuration (@option{-net nic -net user}) which
is activated if no @option{-net} options are provided.
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
DEFHEADING(Character device options:)
DEF("chardev", HAS_ARG, QEMU_OPTION_chardev,
"-chardev help\n"
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
"-chardev null,id=id[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
"-chardev socket,id=id[,host=host],port=port[,to=to][,ipv4][,ipv6][,nodelay][,reconnect=seconds]\n"
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
" [,server][,nowait][,telnet][,reconnect=seconds][,mux=on|off]\n"
char: introduce support for TLS encrypted TCP chardev backend This integrates support for QIOChannelTLS object in the TCP chardev backend. If the 'tls-creds=NAME' option is passed with the '-chardev tcp' argument, then it will setup the chardev such that the client is required to establish a TLS handshake when connecting. There is no support for checking the client certificate against ACLs in this initial patch. This is pending work to QOM-ify the ACL object code. A complete invocation to run QEMU as the server for a TLS encrypted serial dev might be $ qemu-system-x86_64 \ -nodefconfig -nodefaults -device sga -display none \ -chardev socket,id=s0,host=127.0.0.1,port=9000,tls-creds=tls0,server \ -device isa-serial,chardev=s0 \ -object tls-creds-x509,id=tls0,endpoint=server,verify-peer=off,\ dir=/home/berrange/security/qemutls To test with the gnutls-cli tool as the client: $ gnutls-cli --priority=NORMAL -p 9000 \ --x509cafile=/home/berrange/security/qemutls/ca-cert.pem \ 127.0.0.1 If QEMU was told to use 'anon' credential type, then use the priority string 'NORMAL:+ANON-DH' with gnutls-cli Alternatively, if setting up a chardev to operate as a client, then the TLS credentials registered must be for the client endpoint. First a TLS server must be setup, which can be done with the gnutls-serv tool $ gnutls-serv --priority=NORMAL -p 9000 --echo \ --x509cafile=/home/berrange/security/qemutls/ca-cert.pem \ --x509certfile=/home/berrange/security/qemutls/server-cert.pem \ --x509keyfile=/home/berrange/security/qemutls/server-key.pem Then QEMU can connect with $ qemu-system-x86_64 \ -nodefconfig -nodefaults -device sga -display none \ -chardev socket,id=s0,host=127.0.0.1,port=9000,tls-creds=tls0 \ -device isa-serial,chardev=s0 \ -object tls-creds-x509,id=tls0,endpoint=client,\ dir=/home/berrange/security/qemutls Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1453202071-10289-5-git-send-email-berrange@redhat.com> Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-19 19:14:31 +08:00
" [,logfile=PATH][,logappend=on|off][,tls-creds=ID] (tcp)\n"
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
"-chardev socket,id=id,path=path[,server][,nowait][,telnet][,reconnect=seconds]\n"
" [,mux=on|off][,logfile=PATH][,logappend=on|off] (unix)\n"
"-chardev udp,id=id[,host=host],port=port[,localaddr=localaddr]\n"
" [,localport=localport][,ipv4][,ipv6][,mux=on|off]\n"
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
" [,logfile=PATH][,logappend=on|off]\n"
"-chardev msmouse,id=id[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
"-chardev vc,id=id[[,width=width][,height=height]][[,cols=cols][,rows=rows]]\n"
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
" [,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
"-chardev ringbuf,id=id[,size=size][,logfile=PATH][,logappend=on|off]\n"
"-chardev file,id=id,path=path[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
"-chardev pipe,id=id,path=path[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
#ifdef _WIN32
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
"-chardev console,id=id[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
"-chardev serial,id=id,path=path[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
#else
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
"-chardev pty,id=id[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
"-chardev stdio,id=id[,mux=on|off][,signal=on|off][,logfile=PATH][,logappend=on|off]\n"
#endif
#ifdef CONFIG_BRLAPI
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
"-chardev braille,id=id[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
#endif
#if defined(__linux__) || defined(__sun__) || defined(__FreeBSD__) \
|| defined(__NetBSD__) || defined(__OpenBSD__) || defined(__DragonFly__)
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
"-chardev serial,id=id,path=path[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
"-chardev tty,id=id,path=path[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
#endif
#if defined(__linux__) || defined(__FreeBSD__) || defined(__DragonFly__)
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
"-chardev parallel,id=id,path=path[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
"-chardev parport,id=id,path=path[,mux=on|off][,logfile=PATH][,logappend=on|off]\n"
#endif
#if defined(CONFIG_SPICE)
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
"-chardev spicevmc,id=id,name=name[,debug=debug][,logfile=PATH][,logappend=on|off]\n"
"-chardev spiceport,id=id,name=name[,debug=debug][,logfile=PATH][,logappend=on|off]\n"
#endif
, QEMU_ARCH_ALL
)
STEXI
The general form of a character device option is:
@table @option
@item -chardev @var{backend} ,id=@var{id} [,mux=on|off] [,@var{options}]
@findex -chardev
Backend is one of:
@option{null},
@option{socket},
@option{udp},
@option{msmouse},
@option{vc},
Revert "chardev: Make the name of memory device consistent" This reverts commit 6a85e60cb994bd95d1537aafbff65816f3de4637. Commit 51767e7 "qemu-char: Add new char backend CirMemCharDriver" introduced a memory ring buffer character device driver named "memory". Commit 3949e59 "qemu-char: Saner naming of memchar stuff & doc fixes" changed the driver name to "ringbuf", along with a whole bunch of other names, with the following rationale: Naming is a mess. The code calls the device driver CirMemCharDriver, the public API calls it "memory", "memchardev", or "memchar", and the special commands are named like "memchar-FOO". "memory" is a particularly unfortunate choice, because there's another character device driver called MemoryDriver. Moreover, the device's distinctive property is that it's a ring buffer, not that's in memory. This is what we released in 1.4.0. Unfortunately, the rename missed a critical instance of "memory": the actual driver name. Thus, the new device could be used only by an entirely undocumented name. The documented name did not work. Bummer. Commit 6a85e60 fixes this by changing the documentation to match the code. It also changes some, but not all related occurences of "ringbuf" to "memory". Left alone are identifiers in C code, HMP and QMP commands. The latter are external interface, so they can't be changed. The result is an inconsistent mess. Moreover, "memory" is a rotten name. The device's distinctive property is that it's a ring buffer, not that's in memory. User's don't care whether it's in RAM, flash, or carved into chocolate tablets by Oompa Loompas. Revert the commit. Next commit will fix just the bug. Cc: qemu-stable@nongnu.org Signed-off-by: Markus Armbruster <armbru@redhat.com> Reviewed-by: Eric Blake <eblake@redhat.com> Message-id: 1374849874-25531-2-git-send-email-armbru@redhat.com Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2013-07-26 22:44:32 +08:00
@option{ringbuf},
@option{file},
@option{pipe},
@option{console},
@option{serial},
@option{pty},
@option{stdio},
@option{braille},
@option{tty},
@option{parallel},
@option{parport},
@option{spicevmc}.
@option{spiceport}.
The specific backend will determine the applicable options.
Use @code{-chardev help} to print all available chardev backend types.
All devices must have an id, which can be any string up to 127 characters long.
It is used to uniquely identify this device in other command line directives.
A character device may be used in multiplexing mode by multiple front-ends.
Specify @option{mux=on} to enable this mode.
A multiplexer is a "1:N" device, and here the "1" end is your specified chardev
backend, and the "N" end is the various parts of QEMU that can talk to a chardev.
If you create a chardev with @option{id=myid} and @option{mux=on}, QEMU will
create a multiplexer with your specified ID, and you can then configure multiple
front ends to use that chardev ID for their input/output. Up to four different
front ends can be connected to a single multiplexed chardev. (Without
multiplexing enabled, a chardev can only be used by a single front end.)
For instance you could use this to allow a single stdio chardev to be used by
two serial ports and the QEMU monitor:
@example
-chardev stdio,mux=on,id=char0 \
-mon chardev=char0,mode=readline \
-serial chardev:char0 \
-serial chardev:char0
@end example
You can have more than one multiplexer in a system configuration; for instance
you could have a TCP port multiplexed between UART 0 and UART 1, and stdio
multiplexed between the QEMU monitor and a parallel port:
@example
-chardev stdio,mux=on,id=char0 \
-mon chardev=char0,mode=readline \
-parallel chardev:char0 \
-chardev tcp,...,mux=on,id=char1 \
-serial chardev:char1 \
-serial chardev:char1
@end example
When you're using a multiplexed character device, some escape sequences are
interpreted in the input. @xref{mux_keys, Keys in the character backend
multiplexer}.
Note that some other command line options may implicitly create multiplexed
character backends; for instance @option{-serial mon:stdio} creates a
multiplexed stdio backend connected to the serial port and the QEMU monitor,
and @option{-nographic} also multiplexes the console and the monitor to
stdio.
There is currently no support for multiplexing in the other direction
(where a single QEMU front end takes input and output from multiple chardevs).
qemu-char: add logfile facility to all chardev backends Typically a UNIX guest OS will log boot messages to a serial port in addition to any graphical console. An admin user may also wish to use the serial port for an interactive console. A virtualization management system may wish to collect system boot messages by logging the serial port, but also wish to allow admins interactive access. Currently providing such a feature forces the mgmt app to either provide 2 separate serial ports, one for logging boot messages and one for interactive console login, or to proxy all output via a separate service that can multiplex the two needs onto one serial port. While both are valid approaches, they each have their own downsides. The former causes confusion and extra setup work for VM admins creating disk images. The latter places an extra burden to re-implement much of the QEMU chardev backends logic in libvirt or even higher level mgmt apps and adds extra hops in the data transfer path. A simpler approach that is satisfactory for many use cases is to allow the QEMU chardev backends to have a "logfile" property associated with them. $QEMU -chardev socket,host=localhost,port=9000,\ server=on,nowait,id-charserial0,\ logfile=/var/log/libvirt/qemu/test-serial0.log -device isa-serial,chardev=charserial0,id=serial0 This patch introduces a 'ChardevCommon' struct which is setup as a base for all the ChardevBackend types. Ideally this would be registered directly as a base against ChardevBackend, rather than each type, but the QAPI generator doesn't allow that since the ChardevBackend is a non-discriminated union. The ChardevCommon struct provides the optional 'logfile' parameter, as well as 'logappend' which controls whether QEMU truncates or appends (default truncate). Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1452516281-27519-1-git-send-email-berrange@redhat.com> [Call qemu_chr_parse_common if cd->parse is NULL. - Paolo] Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-11 20:44:41 +08:00
Every backend supports the @option{logfile} option, which supplies the path
to a file to record all data transmitted via the backend. The @option{logappend}
option controls whether the log file will be truncated or appended to when
opened.
@end table
The available backends are:
@table @option
@item -chardev null ,id=@var{id}
A void device. This device will not emit any data, and will drop any data it
receives. The null backend does not take any options.
char: introduce support for TLS encrypted TCP chardev backend This integrates support for QIOChannelTLS object in the TCP chardev backend. If the 'tls-creds=NAME' option is passed with the '-chardev tcp' argument, then it will setup the chardev such that the client is required to establish a TLS handshake when connecting. There is no support for checking the client certificate against ACLs in this initial patch. This is pending work to QOM-ify the ACL object code. A complete invocation to run QEMU as the server for a TLS encrypted serial dev might be $ qemu-system-x86_64 \ -nodefconfig -nodefaults -device sga -display none \ -chardev socket,id=s0,host=127.0.0.1,port=9000,tls-creds=tls0,server \ -device isa-serial,chardev=s0 \ -object tls-creds-x509,id=tls0,endpoint=server,verify-peer=off,\ dir=/home/berrange/security/qemutls To test with the gnutls-cli tool as the client: $ gnutls-cli --priority=NORMAL -p 9000 \ --x509cafile=/home/berrange/security/qemutls/ca-cert.pem \ 127.0.0.1 If QEMU was told to use 'anon' credential type, then use the priority string 'NORMAL:+ANON-DH' with gnutls-cli Alternatively, if setting up a chardev to operate as a client, then the TLS credentials registered must be for the client endpoint. First a TLS server must be setup, which can be done with the gnutls-serv tool $ gnutls-serv --priority=NORMAL -p 9000 --echo \ --x509cafile=/home/berrange/security/qemutls/ca-cert.pem \ --x509certfile=/home/berrange/security/qemutls/server-cert.pem \ --x509keyfile=/home/berrange/security/qemutls/server-key.pem Then QEMU can connect with $ qemu-system-x86_64 \ -nodefconfig -nodefaults -device sga -display none \ -chardev socket,id=s0,host=127.0.0.1,port=9000,tls-creds=tls0 \ -device isa-serial,chardev=s0 \ -object tls-creds-x509,id=tls0,endpoint=client,\ dir=/home/berrange/security/qemutls Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1453202071-10289-5-git-send-email-berrange@redhat.com> Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-19 19:14:31 +08:00
@item -chardev socket ,id=@var{id} [@var{TCP options} or @var{unix options}] [,server] [,nowait] [,telnet] [,reconnect=@var{seconds}] [,tls-creds=@var{id}]
Create a two-way stream socket, which can be either a TCP or a unix socket. A
unix socket will be created if @option{path} is specified. Behaviour is
undefined if TCP options are specified for a unix socket.
@option{server} specifies that the socket shall be a listening socket.
@option{nowait} specifies that QEMU should not block waiting for a client to
connect to a listening socket.
@option{telnet} specifies that traffic on the socket should interpret telnet
escape sequences.
@option{reconnect} sets the timeout for reconnecting on non-server sockets when
the remote end goes away. qemu will delay this many seconds and then attempt
to reconnect. Zero disables reconnecting, and is the default.
char: introduce support for TLS encrypted TCP chardev backend This integrates support for QIOChannelTLS object in the TCP chardev backend. If the 'tls-creds=NAME' option is passed with the '-chardev tcp' argument, then it will setup the chardev such that the client is required to establish a TLS handshake when connecting. There is no support for checking the client certificate against ACLs in this initial patch. This is pending work to QOM-ify the ACL object code. A complete invocation to run QEMU as the server for a TLS encrypted serial dev might be $ qemu-system-x86_64 \ -nodefconfig -nodefaults -device sga -display none \ -chardev socket,id=s0,host=127.0.0.1,port=9000,tls-creds=tls0,server \ -device isa-serial,chardev=s0 \ -object tls-creds-x509,id=tls0,endpoint=server,verify-peer=off,\ dir=/home/berrange/security/qemutls To test with the gnutls-cli tool as the client: $ gnutls-cli --priority=NORMAL -p 9000 \ --x509cafile=/home/berrange/security/qemutls/ca-cert.pem \ 127.0.0.1 If QEMU was told to use 'anon' credential type, then use the priority string 'NORMAL:+ANON-DH' with gnutls-cli Alternatively, if setting up a chardev to operate as a client, then the TLS credentials registered must be for the client endpoint. First a TLS server must be setup, which can be done with the gnutls-serv tool $ gnutls-serv --priority=NORMAL -p 9000 --echo \ --x509cafile=/home/berrange/security/qemutls/ca-cert.pem \ --x509certfile=/home/berrange/security/qemutls/server-cert.pem \ --x509keyfile=/home/berrange/security/qemutls/server-key.pem Then QEMU can connect with $ qemu-system-x86_64 \ -nodefconfig -nodefaults -device sga -display none \ -chardev socket,id=s0,host=127.0.0.1,port=9000,tls-creds=tls0 \ -device isa-serial,chardev=s0 \ -object tls-creds-x509,id=tls0,endpoint=client,\ dir=/home/berrange/security/qemutls Signed-off-by: Daniel P. Berrange <berrange@redhat.com> Message-Id: <1453202071-10289-5-git-send-email-berrange@redhat.com> Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2016-01-19 19:14:31 +08:00
@option{tls-creds} requests enablement of the TLS protocol for encryption,
and specifies the id of the TLS credentials to use for the handshake. The
credentials must be previously created with the @option{-object tls-creds}
argument.
TCP and unix socket options are given below:
@table @option
@item TCP options: port=@var{port} [,host=@var{host}] [,to=@var{to}] [,ipv4] [,ipv6] [,nodelay]
@option{host} for a listening socket specifies the local address to be bound.
For a connecting socket species the remote host to connect to. @option{host} is
optional for listening sockets. If not specified it defaults to @code{0.0.0.0}.
@option{port} for a listening socket specifies the local port to be bound. For a
connecting socket specifies the port on the remote host to connect to.
@option{port} can be given as either a port number or a service name.
@option{port} is required.
@option{to} is only relevant to listening sockets. If it is specified, and
@option{port} cannot be bound, QEMU will attempt to bind to subsequent ports up
to and including @option{to} until it succeeds. @option{to} must be specified
as a port number.
@option{ipv4} and @option{ipv6} specify that either IPv4 or IPv6 must be used.
If neither is specified the socket may use either protocol.
@option{nodelay} disables the Nagle algorithm.
@item unix options: path=@var{path}
@option{path} specifies the local path of the unix socket. @option{path} is
required.
@end table
@item -chardev udp ,id=@var{id} [,host=@var{host}] ,port=@var{port} [,localaddr=@var{localaddr}] [,localport=@var{localport}] [,ipv4] [,ipv6]
Sends all traffic from the guest to a remote host over UDP.
@option{host} specifies the remote host to connect to. If not specified it
defaults to @code{localhost}.
@option{port} specifies the port on the remote host to connect to. @option{port}
is required.
@option{localaddr} specifies the local address to bind to. If not specified it
defaults to @code{0.0.0.0}.
@option{localport} specifies the local port to bind to. If not specified any
available local port will be used.
@option{ipv4} and @option{ipv6} specify that either IPv4 or IPv6 must be used.
If neither is specified the device may use either protocol.
@item -chardev msmouse ,id=@var{id}
Forward QEMU's emulated msmouse events to the guest. @option{msmouse} does not
take any options.
@item -chardev vc ,id=@var{id} [[,width=@var{width}] [,height=@var{height}]] [[,cols=@var{cols}] [,rows=@var{rows}]]
Connect to a QEMU text console. @option{vc} may optionally be given a specific
size.
@option{width} and @option{height} specify the width and height respectively of
the console, in pixels.
@option{cols} and @option{rows} specify that the console be sized to fit a text
console with the given dimensions.
Revert "chardev: Make the name of memory device consistent" This reverts commit 6a85e60cb994bd95d1537aafbff65816f3de4637. Commit 51767e7 "qemu-char: Add new char backend CirMemCharDriver" introduced a memory ring buffer character device driver named "memory". Commit 3949e59 "qemu-char: Saner naming of memchar stuff & doc fixes" changed the driver name to "ringbuf", along with a whole bunch of other names, with the following rationale: Naming is a mess. The code calls the device driver CirMemCharDriver, the public API calls it "memory", "memchardev", or "memchar", and the special commands are named like "memchar-FOO". "memory" is a particularly unfortunate choice, because there's another character device driver called MemoryDriver. Moreover, the device's distinctive property is that it's a ring buffer, not that's in memory. This is what we released in 1.4.0. Unfortunately, the rename missed a critical instance of "memory": the actual driver name. Thus, the new device could be used only by an entirely undocumented name. The documented name did not work. Bummer. Commit 6a85e60 fixes this by changing the documentation to match the code. It also changes some, but not all related occurences of "ringbuf" to "memory". Left alone are identifiers in C code, HMP and QMP commands. The latter are external interface, so they can't be changed. The result is an inconsistent mess. Moreover, "memory" is a rotten name. The device's distinctive property is that it's a ring buffer, not that's in memory. User's don't care whether it's in RAM, flash, or carved into chocolate tablets by Oompa Loompas. Revert the commit. Next commit will fix just the bug. Cc: qemu-stable@nongnu.org Signed-off-by: Markus Armbruster <armbru@redhat.com> Reviewed-by: Eric Blake <eblake@redhat.com> Message-id: 1374849874-25531-2-git-send-email-armbru@redhat.com Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2013-07-26 22:44:32 +08:00
@item -chardev ringbuf ,id=@var{id} [,size=@var{size}]
Create a ring buffer with fixed size @option{size}.
@var{size} must be a power of two and defaults to @code{64K}.
@item -chardev file ,id=@var{id} ,path=@var{path}
Log all traffic received from the guest to a file.
@option{path} specifies the path of the file to be opened. This file will be
created if it does not already exist, and overwritten if it does. @option{path}
is required.
@item -chardev pipe ,id=@var{id} ,path=@var{path}
Create a two-way connection to the guest. The behaviour differs slightly between
Windows hosts and other hosts:
On Windows, a single duplex pipe will be created at
@file{\\.pipe\@option{path}}.
On other hosts, 2 pipes will be created called @file{@option{path}.in} and
@file{@option{path}.out}. Data written to @file{@option{path}.in} will be
received by the guest. Data written by the guest can be read from
@file{@option{path}.out}. QEMU will not create these fifos, and requires them to
be present.
@option{path} forms part of the pipe path as described above. @option{path} is
required.
@item -chardev console ,id=@var{id}
Send traffic from the guest to QEMU's standard output. @option{console} does not
take any options.
@option{console} is only available on Windows hosts.
@item -chardev serial ,id=@var{id} ,path=@option{path}
Send traffic from the guest to a serial device on the host.
On Unix hosts serial will actually accept any tty device,
not only serial lines.
@option{path} specifies the name of the serial device to open.
@item -chardev pty ,id=@var{id}
Create a new pseudo-terminal on the host and connect to it. @option{pty} does
not take any options.
@option{pty} is not available on Windows hosts.
@item -chardev stdio ,id=@var{id} [,signal=on|off]
Connect to standard input and standard output of the QEMU process.
@option{signal} controls if signals are enabled on the terminal, that includes
exiting QEMU with the key sequence @key{Control-c}. This option is enabled by
default, use @option{signal=off} to disable it.
@item -chardev braille ,id=@var{id}
Connect to a local BrlAPI server. @option{braille} does not take any options.
@item -chardev tty ,id=@var{id} ,path=@var{path}
@option{tty} is only available on Linux, Sun, FreeBSD, NetBSD, OpenBSD and
DragonFlyBSD hosts. It is an alias for @option{serial}.
@option{path} specifies the path to the tty. @option{path} is required.
@item -chardev parallel ,id=@var{id} ,path=@var{path}
@itemx -chardev parport ,id=@var{id} ,path=@var{path}
@option{parallel} is only available on Linux, FreeBSD and DragonFlyBSD hosts.
Connect to a local parallel port.
@option{path} specifies the path to the parallel port device. @option{path} is
required.
@item -chardev spicevmc ,id=@var{id} ,debug=@var{debug}, name=@var{name}
@option{spicevmc} is only available when spice support is built in.
@option{debug} debug level for spicevmc
@option{name} name of spice channel to connect to
Connect to a spice virtual machine channel, such as vdiport.
@item -chardev spiceport ,id=@var{id} ,debug=@var{debug}, name=@var{name}
@option{spiceport} is only available when spice support is built in.
@option{debug} debug level for spicevmc
@option{name} name of spice port to connect to
Connect to a spice port, allowing a Spice client to handle the traffic
identified by a name (preferably a fqdn).
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
DEFHEADING(Bluetooth(R) options:)
STEXI
@table @option
ETEXI
DEF("bt", HAS_ARG, QEMU_OPTION_bt, \
"-bt hci,null dumb bluetooth HCI - doesn't respond to commands\n" \
"-bt hci,host[:id]\n" \
" use host's HCI with the given name\n" \
"-bt hci[,vlan=n]\n" \
" emulate a standard HCI in virtual scatternet 'n'\n" \
"-bt vhci[,vlan=n]\n" \
" add host computer to virtual scatternet 'n' using VHCI\n" \
"-bt device:dev[,vlan=n]\n" \
" emulate a bluetooth device 'dev' in scatternet 'n'\n",
QEMU_ARCH_ALL)
STEXI
@item -bt hci[...]
@findex -bt
Defines the function of the corresponding Bluetooth HCI. -bt options
are matched with the HCIs present in the chosen machine type. For
example when emulating a machine with only one HCI built into it, only
the first @code{-bt hci[...]} option is valid and defines the HCI's
logic. The Transport Layer is decided by the machine type. Currently
the machines @code{n800} and @code{n810} have one HCI and all other
machines have none.
@anchor{bt-hcis}
The following three types are recognized:
@table @option
@item -bt hci,null
(default) The corresponding Bluetooth HCI assumes no internal logic
and will not respond to any HCI commands or emit events.
@item -bt hci,host[:@var{id}]
(@code{bluez} only) The corresponding HCI passes commands / events
to / from the physical HCI identified by the name @var{id} (default:
@code{hci0}) on the computer running QEMU. Only available on @code{bluez}
capable systems like Linux.
@item -bt hci[,vlan=@var{n}]
Add a virtual, standard HCI that will participate in the Bluetooth
scatternet @var{n} (default @code{0}). Similarly to @option{-net}
VLANs, devices inside a bluetooth network @var{n} can only communicate
with other devices in the same network (scatternet).
@end table
@item -bt vhci[,vlan=@var{n}]
(Linux-host only) Create a HCI in scatternet @var{n} (default 0) attached
to the host bluetooth stack instead of to the emulated target. This
allows the host and target machines to participate in a common scatternet
and communicate. Requires the Linux @code{vhci} driver installed. Can
be used as following:
@example
qemu-system-i386 [...OPTIONS...] -bt hci,vlan=5 -bt vhci,vlan=5
@end example
@item -bt device:@var{dev}[,vlan=@var{n}]
Emulate a bluetooth device @var{dev} and place it in network @var{n}
(default @code{0}). QEMU can only emulate one type of bluetooth devices
currently:
@table @option
@item keyboard
Virtual wireless keyboard implementing the HIDP bluetooth profile.
@end table
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
#ifdef CONFIG_TPM
DEFHEADING(TPM device options:)
DEF("tpmdev", HAS_ARG, QEMU_OPTION_tpmdev, \
"-tpmdev passthrough,id=id[,path=path][,cancel-path=path]\n"
" use path to provide path to a character device; default is /dev/tpm0\n"
" use cancel-path to provide path to TPM's cancel sysfs entry; if\n"
" not provided it will be searched for in /sys/class/misc/tpm?/device\n"
"-tpmdev emulator,id=id,chardev=dev\n"
" configure the TPM device using chardev backend\n",
QEMU_ARCH_ALL)
STEXI
The general form of a TPM device option is:
@table @option
@item -tpmdev @var{backend} ,id=@var{id} [,@var{options}]
@findex -tpmdev
The specific backend type will determine the applicable options.
The @code{-tpmdev} option creates the TPM backend and requires a
@code{-device} option that specifies the TPM frontend interface model.
Use @code{-tpmdev help} to print all available TPM backend types.
@end table
The available backends are:
@table @option
@item -tpmdev passthrough, id=@var{id}, path=@var{path}, cancel-path=@var{cancel-path}
Add a TPM Passthrough backend driver implementation This patch is based of off version 9 of Stefan Berger's patch series "QEMU Trusted Platform Module (TPM) integration" and adds a new backend driver for it. This patch adds a passthrough backend driver for passing commands sent to the emulated TPM device directly to a TPM device opened on the host machine. Thus it is possible to use a hardware TPM device in a system running on QEMU, providing the ability to access a TPM in a special state (e.g. after a Trusted Boot). This functionality is being used in the acTvSM Trusted Virtualization Platform which is available on [1]. Usage example: qemu-system-x86_64 -tpmdev passthrough,id=tpm0,path=/dev/tpm0 \ -device tpm-tis,tpmdev=tpm0 \ -cdrom test.iso -boot d Some notes about the host TPM: The TPM needs to be enabled and activated. If that's not the case one has to go through the BIOS/UEFI and enable and activate that TPM for TPM commands to work as expected. It may be necessary to boot the kernel using tpm_tis.force=1 in the boot command line or 'modprobe tpm_tis force=1' in case of using it as a module. Regards, Andreas Niederl, Stefan Berger [1] http://trustedjava.sourceforge.net/ Signed-off-by: Andreas Niederl <andreas.niederl@iaik.tugraz.at> Signed-off-by: Stefan Berger <stefanb@linux.vnet.ibm.com> Reviewed-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Reviewed-by: Joel Schopp <jschopp@linux.vnet.ibm.com> Message-id: 1361987275-26289-6-git-send-email-stefanb@linux.vnet.ibm.com Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2013-02-28 01:47:53 +08:00
(Linux-host only) Enable access to the host's TPM using the passthrough
driver.
@option{path} specifies the path to the host's TPM device, i.e., on
a Linux host this would be @code{/dev/tpm0}.
@option{path} is optional and by default @code{/dev/tpm0} is used.
@option{cancel-path} specifies the path to the host TPM device's sysfs
entry allowing for cancellation of an ongoing TPM command.
@option{cancel-path} is optional and by default QEMU will search for the
sysfs entry to use.
Add a TPM Passthrough backend driver implementation This patch is based of off version 9 of Stefan Berger's patch series "QEMU Trusted Platform Module (TPM) integration" and adds a new backend driver for it. This patch adds a passthrough backend driver for passing commands sent to the emulated TPM device directly to a TPM device opened on the host machine. Thus it is possible to use a hardware TPM device in a system running on QEMU, providing the ability to access a TPM in a special state (e.g. after a Trusted Boot). This functionality is being used in the acTvSM Trusted Virtualization Platform which is available on [1]. Usage example: qemu-system-x86_64 -tpmdev passthrough,id=tpm0,path=/dev/tpm0 \ -device tpm-tis,tpmdev=tpm0 \ -cdrom test.iso -boot d Some notes about the host TPM: The TPM needs to be enabled and activated. If that's not the case one has to go through the BIOS/UEFI and enable and activate that TPM for TPM commands to work as expected. It may be necessary to boot the kernel using tpm_tis.force=1 in the boot command line or 'modprobe tpm_tis force=1' in case of using it as a module. Regards, Andreas Niederl, Stefan Berger [1] http://trustedjava.sourceforge.net/ Signed-off-by: Andreas Niederl <andreas.niederl@iaik.tugraz.at> Signed-off-by: Stefan Berger <stefanb@linux.vnet.ibm.com> Reviewed-by: Corey Bryant <coreyb@linux.vnet.ibm.com> Reviewed-by: Joel Schopp <jschopp@linux.vnet.ibm.com> Message-id: 1361987275-26289-6-git-send-email-stefanb@linux.vnet.ibm.com Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2013-02-28 01:47:53 +08:00
Some notes about using the host's TPM with the passthrough driver:
The TPM device accessed by the passthrough driver must not be
used by any other application on the host.
Since the host's firmware (BIOS/UEFI) has already initialized the TPM,
the VM's firmware (BIOS/UEFI) will not be able to initialize the
TPM again and may therefore not show a TPM-specific menu that would
otherwise allow the user to configure the TPM, e.g., allow the user to
enable/disable or activate/deactivate the TPM.
Further, if TPM ownership is released from within a VM then the host's TPM
will get disabled and deactivated. To enable and activate the
TPM again afterwards, the host has to be rebooted and the user is
required to enter the firmware's menu to enable and activate the TPM.
If the TPM is left disabled and/or deactivated most TPM commands will fail.
To create a passthrough TPM use the following two options:
@example
-tpmdev passthrough,id=tpm0 -device tpm-tis,tpmdev=tpm0
@end example
Note that the @code{-tpmdev} id is @code{tpm0} and is referenced by
@code{tpmdev=tpm0} in the device option.
@item -tpmdev emulator, id=@var{id}, chardev=@var{dev}
(Linux-host only) Enable access to a TPM emulator using Unix domain socket based
chardev backend.
@option{chardev} specifies the unique ID of a character device backend that provides connection to the software TPM server.
To create a TPM emulator backend device with chardev socket backend:
@example
-chardev socket,id=chrtpm,path=/tmp/swtpm-sock -tpmdev emulator,id=tpm0,chardev=chrtpm -device tpm-tis,tpmdev=tpm0
@end example
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
#endif
DEFHEADING(Linux/Multiboot boot specific:)
STEXI
When using these options, you can use a given Linux or Multiboot
kernel without installing it in the disk image. It can be useful
for easier testing of various kernels.
@table @option
ETEXI
DEF("kernel", HAS_ARG, QEMU_OPTION_kernel, \
"-kernel bzImage use 'bzImage' as kernel image\n", QEMU_ARCH_ALL)
STEXI
@item -kernel @var{bzImage}
@findex -kernel
Use @var{bzImage} as kernel image. The kernel can be either a Linux kernel
or in multiboot format.
ETEXI
DEF("append", HAS_ARG, QEMU_OPTION_append, \
"-append cmdline use 'cmdline' as kernel command line\n", QEMU_ARCH_ALL)
STEXI
@item -append @var{cmdline}
@findex -append
Use @var{cmdline} as kernel command line
ETEXI
DEF("initrd", HAS_ARG, QEMU_OPTION_initrd, \
"-initrd file use 'file' as initial ram disk\n", QEMU_ARCH_ALL)
STEXI
@item -initrd @var{file}
@findex -initrd
Use @var{file} as initial ram disk.
@item -initrd "@var{file1} arg=foo,@var{file2}"
This syntax is only available with multiboot.
Use @var{file1} and @var{file2} as modules and pass arg=foo as parameter to the
first module.
ETEXI
DEF("dtb", HAS_ARG, QEMU_OPTION_dtb, \
"-dtb file use 'file' as device tree image\n", QEMU_ARCH_ALL)
STEXI
@item -dtb @var{file}
@findex -dtb
Use @var{file} as a device tree binary (dtb) image and pass it to the kernel
on boot.
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
DEFHEADING(Debug/Expert options:)
STEXI
@table @option
ETEXI
DEF("fw_cfg", HAS_ARG, QEMU_OPTION_fwcfg,
"-fw_cfg [name=]<name>,file=<file>\n"
" add named fw_cfg entry with contents from file\n"
"-fw_cfg [name=]<name>,string=<str>\n"
" add named fw_cfg entry with contents from string\n",
QEMU_ARCH_ALL)
STEXI
@item -fw_cfg [name=]@var{name},file=@var{file}
@findex -fw_cfg
Add named fw_cfg entry with contents from file @var{file}.
@item -fw_cfg [name=]@var{name},string=@var{str}
Add named fw_cfg entry with contents from string @var{str}.
The terminating NUL character of the contents of @var{str} will not be
included as part of the fw_cfg item data. To insert contents with
embedded NUL characters, you have to use the @var{file} parameter.
The fw_cfg entries are passed by QEMU through to the guest.
Example:
@example
-fw_cfg name=opt/com.mycompany/blob,file=./my_blob.bin
@end example
creates an fw_cfg entry named opt/com.mycompany/blob with contents
from ./my_blob.bin.
ETEXI
DEF("serial", HAS_ARG, QEMU_OPTION_serial, \
"-serial dev redirect the serial port to char device 'dev'\n",
QEMU_ARCH_ALL)
STEXI
@item -serial @var{dev}
@findex -serial
Redirect the virtual serial port to host character device
@var{dev}. The default device is @code{vc} in graphical mode and
@code{stdio} in non graphical mode.
This option can be used several times to simulate up to 4 serial
ports.
Use @code{-serial none} to disable all serial ports.
Available character devices are:
@table @option
@item vc[:@var{W}x@var{H}]
Virtual console. Optionally, a width and height can be given in pixel with
@example
vc:800x600
@end example
It is also possible to specify width or height in characters:
@example
vc:80Cx24C
@end example
@item pty
[Linux only] Pseudo TTY (a new PTY is automatically allocated)
@item none
No device is allocated.
@item null
void device
@item chardev:@var{id}
Use a named character device defined with the @code{-chardev} option.
@item /dev/XXX
[Linux only] Use host tty, e.g. @file{/dev/ttyS0}. The host serial port
parameters are set according to the emulated ones.
@item /dev/parport@var{N}
[Linux only, parallel port only] Use host parallel port
@var{N}. Currently SPP and EPP parallel port features can be used.
@item file:@var{filename}
Write output to @var{filename}. No character can be read.
@item stdio
[Unix only] standard input/output
@item pipe:@var{filename}
name pipe @var{filename}
@item COM@var{n}
[Windows only] Use host serial port @var{n}
@item udp:[@var{remote_host}]:@var{remote_port}[@@[@var{src_ip}]:@var{src_port}]
This implements UDP Net Console.
When @var{remote_host} or @var{src_ip} are not specified
they default to @code{0.0.0.0}.
When not using a specified @var{src_port} a random port is automatically chosen.
If you just want a simple readonly console you can use @code{netcat} or
@code{nc}, by starting QEMU with: @code{-serial udp::4555} and nc as:
@code{nc -u -l -p 4555}. Any time QEMU writes something to that port it
will appear in the netconsole session.
If you plan to send characters back via netconsole or you want to stop
and start QEMU a lot of times, you should have QEMU use the same
source port each time by using something like @code{-serial
udp::4555@@:4556} to QEMU. Another approach is to use a patched
version of netcat which can listen to a TCP port and send and receive
characters via udp. If you have a patched version of netcat which
activates telnet remote echo and single char transfer, then you can
use the following options to set up a netcat redirector to allow
telnet on port 5555 to access the QEMU port.
@table @code
@item QEMU Options:
-serial udp::4555@@:4556
@item netcat options:
-u -P 4555 -L 0.0.0.0:4556 -t -p 5555 -I -T
@item telnet options:
localhost 5555
@end table
@item tcp:[@var{host}]:@var{port}[,@var{server}][,nowait][,nodelay][,reconnect=@var{seconds}]
The TCP Net Console has two modes of operation. It can send the serial
I/O to a location or wait for a connection from a location. By default
the TCP Net Console is sent to @var{host} at the @var{port}. If you use
the @var{server} option QEMU will wait for a client socket application
to connect to the port before continuing, unless the @code{nowait}
option was specified. The @code{nodelay} option disables the Nagle buffering
algorithm. The @code{reconnect} option only applies if @var{noserver} is
set, if the connection goes down it will attempt to reconnect at the
given interval. If @var{host} is omitted, 0.0.0.0 is assumed. Only
one TCP connection at a time is accepted. You can use @code{telnet} to
connect to the corresponding character device.
@table @code
@item Example to send tcp console to 192.168.0.2 port 4444
-serial tcp:192.168.0.2:4444
@item Example to listen and wait on port 4444 for connection
-serial tcp::4444,server
@item Example to not wait and listen on ip 192.168.0.100 port 4444
-serial tcp:192.168.0.100:4444,server,nowait
@end table
@item telnet:@var{host}:@var{port}[,server][,nowait][,nodelay]
The telnet protocol is used instead of raw tcp sockets. The options
work the same as if you had specified @code{-serial tcp}. The
difference is that the port acts like a telnet server or client using
telnet option negotiation. This will also allow you to send the
MAGIC_SYSRQ sequence if you use a telnet that supports sending the break
sequence. Typically in unix telnet you do it with Control-] and then
type "send break" followed by pressing the enter key.
@item unix:@var{path}[,server][,nowait][,reconnect=@var{seconds}]
A unix domain socket is used instead of a tcp socket. The option works the
same as if you had specified @code{-serial tcp} except the unix domain socket
@var{path} is used for connections.
@item mon:@var{dev_string}
This is a special option to allow the monitor to be multiplexed onto
another serial port. The monitor is accessed with key sequence of
@key{Control-a} and then pressing @key{c}.
@var{dev_string} should be any one of the serial devices specified
above. An example to multiplex the monitor onto a telnet server
listening on port 4444 would be:
@table @code
@item -serial mon:telnet::4444,server,nowait
@end table
When the monitor is multiplexed to stdio in this way, Ctrl+C will not terminate
QEMU any more but will be passed to the guest instead.
@item braille
Braille device. This will use BrlAPI to display the braille output on a real
or fake device.
@item msmouse
Three button serial mouse. Configure the guest to use Microsoft protocol.
@end table
ETEXI
DEF("parallel", HAS_ARG, QEMU_OPTION_parallel, \
"-parallel dev redirect the parallel port to char device 'dev'\n",
QEMU_ARCH_ALL)
STEXI
@item -parallel @var{dev}
@findex -parallel
Redirect the virtual parallel port to host device @var{dev} (same
devices as the serial port). On Linux hosts, @file{/dev/parportN} can
be used to use hardware devices connected on the corresponding host
parallel port.
This option can be used several times to simulate up to 3 parallel
ports.
Use @code{-parallel none} to disable all parallel ports.
ETEXI
DEF("monitor", HAS_ARG, QEMU_OPTION_monitor, \
"-monitor dev redirect the monitor to char device 'dev'\n",
QEMU_ARCH_ALL)
STEXI
@item -monitor @var{dev}
@findex -monitor
Redirect the monitor to host device @var{dev} (same devices as the
serial port).
The default device is @code{vc} in graphical mode and @code{stdio} in
non graphical mode.
Use @code{-monitor none} to disable the default monitor.
ETEXI
DEF("qmp", HAS_ARG, QEMU_OPTION_qmp, \
"-qmp dev like -monitor but opens in 'control' mode\n",
QEMU_ARCH_ALL)
STEXI
@item -qmp @var{dev}
@findex -qmp
Like -monitor but opens in 'control' mode.
ETEXI
DEF("qmp-pretty", HAS_ARG, QEMU_OPTION_qmp_pretty, \
"-qmp-pretty dev like -qmp but uses pretty JSON formatting\n",
QEMU_ARCH_ALL)
STEXI
@item -qmp-pretty @var{dev}
@findex -qmp-pretty
Like -qmp but uses pretty JSON formatting.
ETEXI
DEF("mon", HAS_ARG, QEMU_OPTION_mon, \
"-mon [chardev=]name[,mode=readline|control][,pretty[=on|off]]\n", QEMU_ARCH_ALL)
STEXI
@item -mon [chardev=]name[,mode=readline|control][,pretty[=on|off]]
@findex -mon
Setup monitor on chardev @var{name}. @code{pretty} turns on JSON pretty printing
easing human reading and debugging.
ETEXI
DEF("debugcon", HAS_ARG, QEMU_OPTION_debugcon, \
"-debugcon dev redirect the debug console to char device 'dev'\n",
QEMU_ARCH_ALL)
STEXI
@item -debugcon @var{dev}
@findex -debugcon
Redirect the debug console to host device @var{dev} (same devices as the
serial port). The debug console is an I/O port which is typically port
0xe9; writing to that I/O port sends output to this device.
The default device is @code{vc} in graphical mode and @code{stdio} in
non graphical mode.
ETEXI
DEF("pidfile", HAS_ARG, QEMU_OPTION_pidfile, \
"-pidfile file write PID to 'file'\n", QEMU_ARCH_ALL)
STEXI
@item -pidfile @var{file}
@findex -pidfile
Store the QEMU process PID in @var{file}. It is useful if you launch QEMU
from a script.
ETEXI
DEF("singlestep", 0, QEMU_OPTION_singlestep, \
"-singlestep always run in singlestep mode\n", QEMU_ARCH_ALL)
STEXI
@item -singlestep
@findex -singlestep
Run the emulation in single step mode.
ETEXI
DEF("S", 0, QEMU_OPTION_S, \
"-S freeze CPU at startup (use 'c' to start execution)\n",
QEMU_ARCH_ALL)
STEXI
@item -S
@findex -S
Do not start CPU at startup (you must type 'c' in the monitor).
ETEXI
DEF("realtime", HAS_ARG, QEMU_OPTION_realtime,
"-realtime [mlock=on|off]\n"
" run qemu with realtime features\n"
" mlock=on|off controls mlock support (default: on)\n",
QEMU_ARCH_ALL)
STEXI
@item -realtime mlock=on|off
@findex -realtime
Run qemu with realtime features.
mlocking qemu and guest memory can be enabled via @option{mlock=on}
(enabled by default).
ETEXI
DEF("gdb", HAS_ARG, QEMU_OPTION_gdb, \
"-gdb dev wait for gdb connection on 'dev'\n", QEMU_ARCH_ALL)
STEXI
@item -gdb @var{dev}
@findex -gdb
Wait for gdb connection on device @var{dev} (@pxref{gdb_usage}). Typical
connections will likely be TCP-based, but also UDP, pseudo TTY, or even
stdio are reasonable use case. The latter is allowing to start QEMU from
within gdb and establish the connection via a pipe:
@example
(gdb) target remote | exec qemu-system-i386 -gdb stdio ...
@end example
ETEXI
DEF("s", 0, QEMU_OPTION_s, \
"-s shorthand for -gdb tcp::" DEFAULT_GDBSTUB_PORT "\n",
QEMU_ARCH_ALL)
STEXI
@item -s
@findex -s
Shorthand for -gdb tcp::1234, i.e. open a gdbserver on TCP port 1234
(@pxref{gdb_usage}).
ETEXI
DEF("d", HAS_ARG, QEMU_OPTION_d, \
"-d item1,... enable logging of specified items (use '-d help' for a list of log items)\n",
QEMU_ARCH_ALL)
STEXI
@item -d @var{item1}[,...]
@findex -d
Enable logging of specified items. Use '-d help' for a list of log items.
ETEXI
DEF("D", HAS_ARG, QEMU_OPTION_D, \
"-D logfile output log to logfile (default stderr)\n",
QEMU_ARCH_ALL)
STEXI
@item -D @var{logfile}
@findex -D
Output log in @var{logfile} instead of to stderr
ETEXI
DEF("dfilter", HAS_ARG, QEMU_OPTION_DFILTER, \
"-dfilter range,.. filter debug output to range of addresses (useful for -d cpu,exec,etc..)\n",
QEMU_ARCH_ALL)
STEXI
@item -dfilter @var{range1}[,...]
@findex -dfilter
Filter debug output to that relevant to a range of target addresses. The filter
spec can be either @var{start}+@var{size}, @var{start}-@var{size} or
@var{start}..@var{end} where @var{start} @var{end} and @var{size} are the
addresses and sizes required. For example:
@example
-dfilter 0x8000..0x8fff,0xffffffc000080000+0x200,0xffffffc000060000-0x1000
@end example
Will dump output for any code in the 0x1000 sized block starting at 0x8000 and
the 0x200 sized block starting at 0xffffffc000080000 and another 0x1000 sized
block starting at 0xffffffc00005f000.
ETEXI
DEF("L", HAS_ARG, QEMU_OPTION_L, \
"-L path set the directory for the BIOS, VGA BIOS and keymaps\n",
QEMU_ARCH_ALL)
STEXI
@item -L @var{path}
@findex -L
Set the directory for the BIOS, VGA BIOS and keymaps.
To list all the data directories, use @code{-L help}.
ETEXI
DEF("bios", HAS_ARG, QEMU_OPTION_bios, \
"-bios file set the filename for the BIOS\n", QEMU_ARCH_ALL)
STEXI
@item -bios @var{file}
@findex -bios
Set the filename for the BIOS.
ETEXI
DEF("enable-kvm", 0, QEMU_OPTION_enable_kvm, \
"-enable-kvm enable KVM full virtualization support\n", QEMU_ARCH_ALL)
STEXI
@item -enable-kvm
@findex -enable-kvm
Enable KVM full virtualization support. This option is only available
if KVM support is enabled when compiling.
ETEXI
DEF("enable-hax", 0, QEMU_OPTION_enable_hax, \
"-enable-hax enable HAX virtualization support\n", QEMU_ARCH_I386)
STEXI
@item -enable-hax
@findex -enable-hax
Enable HAX (Hardware-based Acceleration eXecution) support. This option
is only available if HAX support is enabled when compiling. HAX is only
applicable to MAC and Windows platform, and thus does not conflict with
KVM.
ETEXI
DEF("xen-domid", HAS_ARG, QEMU_OPTION_xen_domid,
"-xen-domid id specify xen guest domain id\n", QEMU_ARCH_ALL)
DEF("xen-create", 0, QEMU_OPTION_xen_create,
"-xen-create create domain using xen hypercalls, bypassing xend\n"
" warning: should not be used when xend is in use\n",
QEMU_ARCH_ALL)
DEF("xen-attach", 0, QEMU_OPTION_xen_attach,
"-xen-attach attach to existing xen domain\n"
" xend will use this when starting QEMU\n",
QEMU_ARCH_ALL)
DEF("xen-domid-restrict", 0, QEMU_OPTION_xen_domid_restrict,
"-xen-domid-restrict restrict set of available xen operations\n"
" to specified domain id. (Does not affect\n"
" xenpv machine type).\n",
QEMU_ARCH_ALL)
STEXI
@item -xen-domid @var{id}
@findex -xen-domid
Specify xen guest domain @var{id} (XEN only).
@item -xen-create
@findex -xen-create
Create domain using xen hypercalls, bypassing xend.
Warning: should not be used when xend is in use (XEN only).
@item -xen-attach
@findex -xen-attach
Attach to existing xen domain.
xend will use this when starting QEMU (XEN only).
@findex -xen-domid-restrict
Restrict set of available xen operations to specified domain id (XEN only).
ETEXI
DEF("no-reboot", 0, QEMU_OPTION_no_reboot, \
"-no-reboot exit instead of rebooting\n", QEMU_ARCH_ALL)
STEXI
@item -no-reboot
@findex -no-reboot
Exit instead of rebooting.
ETEXI
DEF("no-shutdown", 0, QEMU_OPTION_no_shutdown, \
"-no-shutdown stop before shutdown\n", QEMU_ARCH_ALL)
STEXI
@item -no-shutdown
@findex -no-shutdown
Don't exit QEMU on guest shutdown, but instead only stop the emulation.
This allows for instance switching to monitor to commit changes to the
disk image.
ETEXI
DEF("loadvm", HAS_ARG, QEMU_OPTION_loadvm, \
"-loadvm [tag|id]\n" \
" start right away with a saved state (loadvm in monitor)\n",
QEMU_ARCH_ALL)
STEXI
@item -loadvm @var{file}
@findex -loadvm
Start right away with a saved state (@code{loadvm} in monitor)
ETEXI
#ifndef _WIN32
DEF("daemonize", 0, QEMU_OPTION_daemonize, \
"-daemonize daemonize QEMU after initializing\n", QEMU_ARCH_ALL)
#endif
STEXI
@item -daemonize
@findex -daemonize
Daemonize the QEMU process after initialization. QEMU will not detach from
standard IO until it is ready to receive connections on any of its devices.
This option is a useful way for external programs to launch QEMU without having
to cope with initialization race conditions.
ETEXI
DEF("option-rom", HAS_ARG, QEMU_OPTION_option_rom, \
"-option-rom rom load a file, rom, into the option ROM space\n",
QEMU_ARCH_ALL)
STEXI
@item -option-rom @var{file}
@findex -option-rom
Load the contents of @var{file} as an option ROM.
This option is useful to load things like EtherBoot.
ETEXI
HXCOMM Silently ignored for compatibility
DEF("clock", HAS_ARG, QEMU_OPTION_clock, "", QEMU_ARCH_ALL)
HXCOMM Options deprecated by -rtc
DEF("localtime", 0, QEMU_OPTION_localtime, "", QEMU_ARCH_ALL)
DEF("startdate", HAS_ARG, QEMU_OPTION_startdate, "", QEMU_ARCH_ALL)
DEF("rtc", HAS_ARG, QEMU_OPTION_rtc, \
"-rtc [base=utc|localtime|date][,clock=host|rt|vm][,driftfix=none|slew]\n" \
" set the RTC base and clock, enable drift fix for clock ticks (x86 only)\n",
QEMU_ARCH_ALL)
STEXI
@item -rtc [base=utc|localtime|@var{date}][,clock=host|vm][,driftfix=none|slew]
@findex -rtc
Specify @option{base} as @code{utc} or @code{localtime} to let the RTC start at the current
UTC or local time, respectively. @code{localtime} is required for correct date in
MS-DOS or Windows. To start at a specific point in time, provide @var{date} in the
format @code{2006-06-17T16:01:21} or @code{2006-06-17}. The default base is UTC.
By default the RTC is driven by the host system time. This allows using of the
RTC as accurate reference clock inside the guest, specifically if the host
time is smoothly following an accurate external reference clock, e.g. via NTP.
If you want to isolate the guest time from the host, you can set @option{clock}
to @code{rt} instead. To even prevent it from progressing during suspension,
you can set it to @code{vm}.
Enable @option{driftfix} (i386 targets only) if you experience time drift problems,
specifically with Windows' ACPI HAL. This option will try to figure out how
many timer interrupts were not processed by the Windows guest and will
re-inject them.
ETEXI
DEF("icount", HAS_ARG, QEMU_OPTION_icount, \
"-icount [shift=N|auto][,align=on|off][,sleep=on|off,rr=record|replay,rrfile=<filename>,rrsnapshot=<snapshot>]\n" \
" enable virtual instruction counter with 2^N clock ticks per\n" \
" instruction, enable aligning the host and virtual clocks\n" \
" or disable real time cpu sleeping\n", QEMU_ARCH_ALL)
STEXI
@item -icount [shift=@var{N}|auto][,rr=record|replay,rrfile=@var{filename},rrsnapshot=@var{snapshot}]
@findex -icount
Enable virtual instruction counter. The virtual cpu will execute one
instruction every 2^@var{N} ns of virtual time. If @code{auto} is specified
then the virtual cpu speed will be automatically adjusted to keep virtual
time within a few seconds of real time.
When the virtual cpu is sleeping, the virtual time will advance at default
speed unless @option{sleep=on|off} is specified.
With @option{sleep=on|off}, the virtual time will jump to the next timer deadline
instantly whenever the virtual cpu goes to sleep mode and will not advance
if no timer is enabled. This behavior give deterministic execution times from
the guest point of view.
Note that while this option can give deterministic behavior, it does not
provide cycle accurate emulation. Modern CPUs contain superscalar out of
order cores with complex cache hierarchies. The number of instructions
executed often has little or no correlation with actual performance.
@option{align=on} will activate the delay algorithm which will try
to synchronise the host clock and the virtual clock. The goal is to
have a guest running at the real frequency imposed by the shift option.
Whenever the guest clock is behind the host clock and if
@option{align=on} is specified then we print a message to the user
to inform about the delay.
Currently this option does not work when @option{shift} is @code{auto}.
Note: The sync algorithm will work for those shift values for which
the guest clock runs ahead of the host clock. Typically this happens
when the shift value is high (how high depends on the host machine).
When @option{rr} option is specified deterministic record/replay is enabled.
Replay log is written into @var{filename} file in record mode and
read from this file in replay mode.
Option rrsnapshot is used to create new vm snapshot named @var{snapshot}
at the start of execution recording. In replay mode this option is used
to load the initial VM state.
ETEXI
DEF("watchdog", HAS_ARG, QEMU_OPTION_watchdog, \
"-watchdog model\n" \
" enable virtual hardware watchdog [default=none]\n",
QEMU_ARCH_ALL)
STEXI
@item -watchdog @var{model}
@findex -watchdog
Create a virtual hardware watchdog device. Once enabled (by a guest
action), the watchdog must be periodically polled by an agent inside
the guest or else the guest will be restarted. Choose a model for
which your guest has drivers.
The @var{model} is the model of hardware watchdog to emulate. Use
@code{-watchdog help} to list available hardware models. Only one
watchdog can be enabled for a guest.
The following models may be available:
@table @option
@item ib700
iBASE 700 is a very simple ISA watchdog with a single timer.
@item i6300esb
Intel 6300ESB I/O controller hub is a much more featureful PCI-based
dual-timer watchdog.
@item diag288
A virtual watchdog for s390x backed by the diagnose 288 hypercall
(currently KVM only).
@end table
ETEXI
DEF("watchdog-action", HAS_ARG, QEMU_OPTION_watchdog_action, \
"-watchdog-action reset|shutdown|poweroff|pause|debug|none\n" \
" action when watchdog fires [default=reset]\n",
QEMU_ARCH_ALL)
STEXI
@item -watchdog-action @var{action}
@findex -watchdog-action
The @var{action} controls what QEMU will do when the watchdog timer
expires.
The default is
@code{reset} (forcefully reset the guest).
Other possible actions are:
@code{shutdown} (attempt to gracefully shutdown the guest),
@code{poweroff} (forcefully poweroff the guest),
@code{pause} (pause the guest),
@code{debug} (print a debug message and continue), or
@code{none} (do nothing).
Note that the @code{shutdown} action requires that the guest responds
to ACPI signals, which it may not be able to do in the sort of
situations where the watchdog would have expired, and thus
@code{-watchdog-action shutdown} is not recommended for production use.
Examples:
@table @code
@item -watchdog i6300esb -watchdog-action pause
@itemx -watchdog ib700
@end table
ETEXI
DEF("echr", HAS_ARG, QEMU_OPTION_echr, \
"-echr chr set terminal escape character instead of ctrl-a\n",
QEMU_ARCH_ALL)
STEXI
@item -echr @var{numeric_ascii_value}
@findex -echr
Change the escape character used for switching to the monitor when using
monitor and serial sharing. The default is @code{0x01} when using the
@code{-nographic} option. @code{0x01} is equal to pressing
@code{Control-a}. You can select a different character from the ascii
control keys where 1 through 26 map to Control-a through Control-z. For
instance you could use the either of the following to change the escape
character to Control-t.
@table @code
@item -echr 0x14
@itemx -echr 20
@end table
ETEXI
DEF("virtioconsole", HAS_ARG, QEMU_OPTION_virtiocon, \
"-virtioconsole c\n" \
" set virtio console\n", QEMU_ARCH_ALL)
STEXI
@item -virtioconsole @var{c}
@findex -virtioconsole
Set virtio console.
virtio-console: qdev conversion, new virtio-serial-bus This commit converts the virtio-console device to create a new virtio-serial bus that can host console and generic serial ports. The file hosting this code is now called virtio-serial-bus.c. The virtio console is now a very simple qdev device that sits on the virtio-serial-bus and communicates between the bus and qemu's chardevs. This commit also includes a few changes to the virtio backing code for pci and s390 to spawn the virtio-serial bus. As a result of the qdev conversion, we get rid of a lot of legacy code. The old-style way of instantiating a virtio console using -virtioconsole ... is maintained, but the new, preferred way is to use -device virtio-serial -device virtconsole,chardev=... With this commit, multiple devices as well as multiple ports with a single device can be supported. For multiple ports support, each port gets an IO vq pair. Since the guest needs to know in advance how many vqs a particular device will need, we have to set this number as a property of the virtio-serial device and also as a config option. In addition, we also spawn a pair of control IO vqs. This is an internal channel meant for guest-host communication for things like port open/close, sending port properties over to the guest, etc. This commit is a part of a series of other commits to get the full implementation of multiport support. Future commits will add other support as well as ride on the savevm version that we bump up here. Signed-off-by: Amit Shah <amit.shah@redhat.com> Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
2010-01-20 03:06:52 +08:00
This option is maintained for backward compatibility.
Please use @code{-device virtconsole} for the new way of invocation.
ETEXI
DEF("show-cursor", 0, QEMU_OPTION_show_cursor, \
"-show-cursor show cursor\n", QEMU_ARCH_ALL)
STEXI
@item -show-cursor
@findex -show-cursor
Show cursor.
ETEXI
DEF("tb-size", HAS_ARG, QEMU_OPTION_tb_size, \
"-tb-size n set TB size\n", QEMU_ARCH_ALL)
STEXI
@item -tb-size @var{n}
@findex -tb-size
Set TB size.
ETEXI
DEF("incoming", HAS_ARG, QEMU_OPTION_incoming, \
"-incoming tcp:[host]:port[,to=maxport][,ipv4][,ipv6]\n" \
"-incoming rdma:host:port[,ipv4][,ipv6]\n" \
"-incoming unix:socketpath\n" \
" prepare for incoming migration, listen on\n" \
" specified protocol and socket address\n" \
"-incoming fd:fd\n" \
"-incoming exec:cmdline\n" \
" accept incoming migration on given file descriptor\n" \
" or from given external command\n" \
"-incoming defer\n" \
" wait for the URI to be specified via migrate_incoming\n",
QEMU_ARCH_ALL)
STEXI
@item -incoming tcp:[@var{host}]:@var{port}[,to=@var{maxport}][,ipv4][,ipv6]
@itemx -incoming rdma:@var{host}:@var{port}[,ipv4][,ipv6]
@findex -incoming
Prepare for incoming migration, listen on a given tcp port.
@item -incoming unix:@var{socketpath}
Prepare for incoming migration, listen on a given unix socket.
@item -incoming fd:@var{fd}
Accept incoming migration from a given filedescriptor.
@item -incoming exec:@var{cmdline}
Accept incoming migration as an output from specified external command.
@item -incoming defer
Wait for the URI to be specified via migrate_incoming. The monitor can
be used to change settings (such as migration parameters) prior to issuing
the migrate_incoming to allow the migration to begin.
ETEXI
DEF("only-migratable", 0, QEMU_OPTION_only_migratable, \
"-only-migratable allow only migratable devices\n", QEMU_ARCH_ALL)
STEXI
@item -only-migratable
@findex -only-migratable
Only allow migratable devices. Devices will not be allowed to enter an
unmigratable state.
ETEXI
DEF("nodefaults", 0, QEMU_OPTION_nodefaults, \
"-nodefaults don't create default devices\n", QEMU_ARCH_ALL)
STEXI
@item -nodefaults
@findex -nodefaults
Don't create default devices. Normally, QEMU sets the default devices like serial
port, parallel port, virtual console, monitor device, VGA adapter, floppy and
CD-ROM drive and others. The @code{-nodefaults} option will disable all those
default devices.
ETEXI
#ifndef _WIN32
DEF("chroot", HAS_ARG, QEMU_OPTION_chroot, \
"-chroot dir chroot to dir just before starting the VM\n",
QEMU_ARCH_ALL)
#endif
STEXI
@item -chroot @var{dir}
@findex -chroot
Immediately before starting guest execution, chroot to the specified
directory. Especially useful in combination with -runas.
ETEXI
#ifndef _WIN32
DEF("runas", HAS_ARG, QEMU_OPTION_runas, \
"-runas user change to user id user just before starting the VM\n",
QEMU_ARCH_ALL)
#endif
STEXI
@item -runas @var{user}
@findex -runas
Immediately before starting guest execution, drop root privileges, switching
to the specified user.
ETEXI
DEF("prom-env", HAS_ARG, QEMU_OPTION_prom_env,
"-prom-env variable=value\n"
" set OpenBIOS nvram variables\n",
QEMU_ARCH_PPC | QEMU_ARCH_SPARC)
STEXI
@item -prom-env @var{variable}=@var{value}
@findex -prom-env
Set OpenBIOS nvram @var{variable} to given @var{value} (PPC, SPARC only).
ETEXI
DEF("semihosting", 0, QEMU_OPTION_semihosting,
"-semihosting semihosting mode\n",
QEMU_ARCH_ARM | QEMU_ARCH_M68K | QEMU_ARCH_XTENSA | QEMU_ARCH_LM32 |
QEMU_ARCH_MIPS)
STEXI
@item -semihosting
@findex -semihosting
Enable semihosting mode (ARM, M68K, Xtensa, MIPS only).
ETEXI
DEF("semihosting-config", HAS_ARG, QEMU_OPTION_semihosting_config,
"-semihosting-config [enable=on|off][,target=native|gdb|auto][,arg=str[,...]]\n" \
" semihosting configuration\n",
QEMU_ARCH_ARM | QEMU_ARCH_M68K | QEMU_ARCH_XTENSA | QEMU_ARCH_LM32 |
QEMU_ARCH_MIPS)
STEXI
@item -semihosting-config [enable=on|off][,target=native|gdb|auto][,arg=str[,...]]
@findex -semihosting-config
Enable and configure semihosting (ARM, M68K, Xtensa, MIPS only).
@table @option
@item target=@code{native|gdb|auto}
Defines where the semihosting calls will be addressed, to QEMU (@code{native})
or to GDB (@code{gdb}). The default is @code{auto}, which means @code{gdb}
during debug sessions and @code{native} otherwise.
@item arg=@var{str1},arg=@var{str2},...
Allows the user to pass input arguments, and can be used multiple times to build
up a list. The old-style @code{-kernel}/@code{-append} method of passing a
command line is still supported for backward compatibility. If both the
@code{--semihosting-config arg} and the @code{-kernel}/@code{-append} are
specified, the former is passed to semihosting as it always takes precedence.
@end table
ETEXI
DEF("old-param", 0, QEMU_OPTION_old_param,
"-old-param old param mode\n", QEMU_ARCH_ARM)
STEXI
@item -old-param
@findex -old-param (ARM)
Old param mode (ARM only).
ETEXI
DEF("sandbox", HAS_ARG, QEMU_OPTION_sandbox, \
"-sandbox on[,obsolete=allow|deny][,elevateprivileges=allow|deny|children]\n" \
" [,spawn=allow|deny][,resourcecontrol=allow|deny]\n" \
" Enable seccomp mode 2 system call filter (default 'off').\n" \
" use 'obsolete' to allow obsolete system calls that are provided\n" \
" by the kernel, but typically no longer used by modern\n" \
" C library implementations.\n" \
" use 'elevateprivileges' to allow or deny QEMU process to elevate\n" \
" its privileges by blacklisting all set*uid|gid system calls.\n" \
" The value 'children' will deny set*uid|gid system calls for\n" \
" main QEMU process but will allow forks and execves to run unprivileged\n" \
" use 'spawn' to avoid QEMU to spawn new threads or processes by\n" \
" blacklisting *fork and execve\n" \
" use 'resourcecontrol' to disable process affinity and schedular priority\n",
QEMU_ARCH_ALL)
STEXI
@item -sandbox @var{arg}[,obsolete=@var{string}][,elevateprivileges=@var{string}][,spawn=@var{string}][,resourcecontrol=@var{string}]
@findex -sandbox
Enable Seccomp mode 2 system call filter. 'on' will enable syscall filtering and 'off' will
disable it. The default is 'off'.
@table @option
@item obsolete=@var{string}
Enable Obsolete system calls
@item elevateprivileges=@var{string}
Disable set*uid|gid system calls
@item spawn=@var{string}
Disable *fork and execve
@item resourcecontrol=@var{string}
Disable process affinity and schedular priority
@end table
ETEXI
DEF("readconfig", HAS_ARG, QEMU_OPTION_readconfig,
"-readconfig <file>\n", QEMU_ARCH_ALL)
STEXI
@item -readconfig @var{file}
@findex -readconfig
Read device configuration from @var{file}. This approach is useful when you want to spawn
QEMU process with many command line options but you don't want to exceed the command line
character limit.
ETEXI
DEF("writeconfig", HAS_ARG, QEMU_OPTION_writeconfig,
"-writeconfig <file>\n"
" read/write config file\n", QEMU_ARCH_ALL)
STEXI
@item -writeconfig @var{file}
@findex -writeconfig
Write device configuration to @var{file}. The @var{file} can be either filename to save
command line and device configuration into file or dash @code{-}) character to print the
output to stdout. This can be later used as input file for @code{-readconfig} option.
ETEXI
HXCOMM Deprecated, same as -no-user-config
DEF("nodefconfig", 0, QEMU_OPTION_nodefconfig, "", QEMU_ARCH_ALL)
DEF("no-user-config", 0, QEMU_OPTION_nouserconfig,
"-no-user-config\n"
" do not load default user-provided config files at startup\n",
QEMU_ARCH_ALL)
STEXI
@item -no-user-config
@findex -no-user-config
The @code{-no-user-config} option makes QEMU not load any of the user-provided
config files on @var{sysconfdir}.
ETEXI
DEF("trace", HAS_ARG, QEMU_OPTION_trace,
"-trace [[enable=]<pattern>][,events=<file>][,file=<file>]\n"
" specify tracing options\n",
QEMU_ARCH_ALL)
STEXI
HXCOMM This line is not accurate, as some sub-options are backend-specific but
HXCOMM HX does not support conditional compilation of text.
@item -trace [[enable=]@var{pattern}][,events=@var{file}][,file=@var{file}]
@findex -trace
@include qemu-option-trace.texi
ETEXI
HXCOMM Internal use
DEF("qtest", HAS_ARG, QEMU_OPTION_qtest, "", QEMU_ARCH_ALL)
DEF("qtest-log", HAS_ARG, QEMU_OPTION_qtest_log, "", QEMU_ARCH_ALL)
#ifdef __linux__
DEF("enable-fips", 0, QEMU_OPTION_enablefips,
"-enable-fips enable FIPS 140-2 compliance\n",
QEMU_ARCH_ALL)
#endif
STEXI
@item -enable-fips
@findex -enable-fips
Enable FIPS 140-2 compliance mode.
ETEXI
HXCOMM Deprecated by -machine accel=tcg property
DEF("no-kvm", 0, QEMU_OPTION_no_kvm, "", QEMU_ARCH_I386)
HXCOMM Deprecated by kvm-pit driver properties
DEF("no-kvm-pit-reinjection", 0, QEMU_OPTION_no_kvm_pit_reinjection,
"", QEMU_ARCH_I386)
HXCOMM Deprecated (ignored)
DEF("no-kvm-pit", 0, QEMU_OPTION_no_kvm_pit, "", QEMU_ARCH_I386)
HXCOMM Deprecated by -machine kernel_irqchip=on|off property
DEF("no-kvm-irqchip", 0, QEMU_OPTION_no_kvm_irqchip, "", QEMU_ARCH_I386)
HXCOMM Deprecated (ignored)
DEF("tdf", 0, QEMU_OPTION_tdf,"", QEMU_ARCH_ALL)
DEF("msg", HAS_ARG, QEMU_OPTION_msg,
"-msg timestamp[=on|off]\n"
" change the format of messages\n"
" on|off controls leading timestamps (default:on)\n",
QEMU_ARCH_ALL)
STEXI
@item -msg timestamp[=on|off]
@findex -msg
prepend a timestamp to each log message.(default:on)
ETEXI
DEF("dump-vmstate", HAS_ARG, QEMU_OPTION_dump_vmstate,
"-dump-vmstate <file>\n"
" Output vmstate information in JSON format to file.\n"
" Use the scripts/vmstate-static-checker.py file to\n"
" check for possible regressions in migration code\n"
" by comparing two such vmstate dumps.\n",
QEMU_ARCH_ALL)
STEXI
@item -dump-vmstate @var{file}
@findex -dump-vmstate
Dump json-encoded vmstate information for current machine type to file
in @var{file}
ETEXI
STEXI
@end table
ETEXI
DEFHEADING()
DEFHEADING(Generic object creation:)
STEXI
@table @option
ETEXI
DEF("object", HAS_ARG, QEMU_OPTION_object,
"-object TYPENAME[,PROP1=VALUE1,...]\n"
" create a new object of type TYPENAME setting properties\n"
" in the order they are specified. Note that the 'id'\n"
" property must be set. These objects are placed in the\n"
" '/objects' path.\n",
QEMU_ARCH_ALL)
STEXI
@item -object @var{typename}[,@var{prop1}=@var{value1},...]
@findex -object
Create a new object of type @var{typename} setting properties
in the order they are specified. Note that the 'id'
property must be set. These objects are placed in the
'/objects' path.
@table @option
@item -object memory-backend-file,id=@var{id},size=@var{size},mem-path=@var{dir},share=@var{on|off},discard-data=@var{on|off}
Creates a memory file backend object, which can be used to back
the guest RAM with huge pages. The @option{id} parameter is a
unique ID that will be used to reference this memory region
when configuring the @option{-numa} argument. The @option{size}
option provides the size of the memory region, and accepts
common suffixes, eg @option{500M}. The @option{mem-path} provides
the path to either a shared memory or huge page filesystem mount.
The @option{share} boolean option determines whether the memory
region is marked as private to QEMU, or shared. The latter allows
a co-operating external process to access the QEMU memory region.
Setting the @option{discard-data} boolean option to @var{on}
indicates that file contents can be destroyed when QEMU exits,
to avoid unnecessarily flushing data to the backing file. Note
that @option{discard-data} is only an optimization, and QEMU
might not discard file contents if it aborts unexpectedly or is
terminated using SIGKILL.
@item -object rng-random,id=@var{id},filename=@var{/dev/random}
Creates a random number generator backend which obtains entropy from
a device on the host. The @option{id} parameter is a unique ID that
will be used to reference this entropy backend from the @option{virtio-rng}
device. The @option{filename} parameter specifies which file to obtain
entropy from and if omitted defaults to @option{/dev/random}.
@item -object rng-egd,id=@var{id},chardev=@var{chardevid}
Creates a random number generator backend which obtains entropy from
an external daemon running on the host. The @option{id} parameter is
a unique ID that will be used to reference this entropy backend from
the @option{virtio-rng} device. The @option{chardev} parameter is
the unique ID of a character device backend that provides the connection
to the RNG daemon.
@item -object tls-creds-anon,id=@var{id},endpoint=@var{endpoint},dir=@var{/path/to/cred/dir},verify-peer=@var{on|off}
Creates a TLS anonymous credentials object, which can be used to provide
TLS support on network backends. The @option{id} parameter is a unique
ID which network backends will use to access the credentials. The
@option{endpoint} is either @option{server} or @option{client} depending
on whether the QEMU network backend that uses the credentials will be
acting as a client or as a server. If @option{verify-peer} is enabled
(the default) then once the handshake is completed, the peer credentials
will be verified, though this is a no-op for anonymous credentials.
The @var{dir} parameter tells QEMU where to find the credential
files. For server endpoints, this directory may contain a file
@var{dh-params.pem} providing diffie-hellman parameters to use
for the TLS server. If the file is missing, QEMU will generate
a set of DH parameters at startup. This is a computationally
expensive operation that consumes random pool entropy, so it is
recommended that a persistent set of parameters be generated
upfront and saved.
@item -object tls-creds-x509,id=@var{id},endpoint=@var{endpoint},dir=@var{/path/to/cred/dir},verify-peer=@var{on|off},passwordid=@var{id}
Creates a TLS anonymous credentials object, which can be used to provide
TLS support on network backends. The @option{id} parameter is a unique
ID which network backends will use to access the credentials. The
@option{endpoint} is either @option{server} or @option{client} depending
on whether the QEMU network backend that uses the credentials will be
acting as a client or as a server. If @option{verify-peer} is enabled
(the default) then once the handshake is completed, the peer credentials
will be verified. With x509 certificates, this implies that the clients
must be provided with valid client certificates too.
The @var{dir} parameter tells QEMU where to find the credential
files. For server endpoints, this directory may contain a file
@var{dh-params.pem} providing diffie-hellman parameters to use
for the TLS server. If the file is missing, QEMU will generate
a set of DH parameters at startup. This is a computationally
expensive operation that consumes random pool entropy, so it is
recommended that a persistent set of parameters be generated
upfront and saved.
For x509 certificate credentials the directory will contain further files
providing the x509 certificates. The certificates must be stored
in PEM format, in filenames @var{ca-cert.pem}, @var{ca-crl.pem} (optional),
@var{server-cert.pem} (only servers), @var{server-key.pem} (only servers),
@var{client-cert.pem} (only clients), and @var{client-key.pem} (only clients).
For the @var{server-key.pem} and @var{client-key.pem} files which
contain sensitive private keys, it is possible to use an encrypted
version by providing the @var{passwordid} parameter. This provides
the ID of a previously created @code{secret} object containing the
password for decryption.
@item -object filter-buffer,id=@var{id},netdev=@var{netdevid},interval=@var{t}[,queue=@var{all|rx|tx}][,status=@var{on|off}]
Interval @var{t} can't be 0, this filter batches the packet delivery: all
packets arriving in a given interval on netdev @var{netdevid} are delayed
until the end of the interval. Interval is in microseconds.
@option{status} is optional that indicate whether the netfilter is
on (enabled) or off (disabled), the default status for netfilter will be 'on'.
queue @var{all|rx|tx} is an option that can be applied to any netfilter.
@option{all}: the filter is attached both to the receive and the transmit
queue of the netdev (default).
@option{rx}: the filter is attached to the receive queue of the netdev,
where it will receive packets sent to the netdev.
@option{tx}: the filter is attached to the transmit queue of the netdev,
where it will receive packets sent by the netdev.
@item -object filter-mirror,id=@var{id},netdev=@var{netdevid},outdev=@var{chardevid},queue=@var{all|rx|tx}[,vnet_hdr_support]
filter-mirror on netdev @var{netdevid},mirror net packet to chardev@var{chardevid}, if it has the vnet_hdr_support flag, filter-mirror will mirror packet with vnet_hdr_len.
@item -object filter-redirector,id=@var{id},netdev=@var{netdevid},indev=@var{chardevid},outdev=@var{chardevid},queue=@var{all|rx|tx}[,vnet_hdr_support]
filter-redirector on netdev @var{netdevid},redirect filter's net packet to chardev
@var{chardevid},and redirect indev's packet to filter.if it has the vnet_hdr_support flag,
filter-redirector will redirect packet with vnet_hdr_len.
Create a filter-redirector we need to differ outdev id from indev id, id can not
be the same. we can just use indev or outdev, but at least one of indev or outdev
need to be specified.
@item -object filter-rewriter,id=@var{id},netdev=@var{netdevid},queue=@var{all|rx|tx},[vnet_hdr_support]
Filter-rewriter is a part of COLO project.It will rewrite tcp packet to
secondary from primary to keep secondary tcp connection,and rewrite
tcp packet to primary from secondary make tcp packet can be handled by
client.if it has the vnet_hdr_support flag, we can parse packet with vnet header.
usage:
colo secondary:
-object filter-redirector,id=f1,netdev=hn0,queue=tx,indev=red0
-object filter-redirector,id=f2,netdev=hn0,queue=rx,outdev=red1
-object filter-rewriter,id=rew0,netdev=hn0,queue=all
@item -object filter-dump,id=@var{id},netdev=@var{dev}[,file=@var{filename}][,maxlen=@var{len}]
Dump the network traffic on netdev @var{dev} to the file specified by
@var{filename}. At most @var{len} bytes (64k by default) per packet are stored.
The file format is libpcap, so it can be analyzed with tools such as tcpdump
or Wireshark.
@item -object colo-compare,id=@var{id},primary_in=@var{chardevid},secondary_in=@var{chardevid},outdev=@var{chardevid}[,vnet_hdr_support]
colo-compare: introduce colo compare initialization This a COLO net ascii figure: Primary qemu Secondary qemu +--------------------------------------------------------------+ +----------------------------------------------------------------+ | +----------------------------------------------------------+ | | +-----------------------------------------------------------+ | | | | | | | | | | | guest | | | | guest | | | | | | | | | | | +-------^--------------------------+-----------------------+ | | +---------------------+--------+----------------------------+ | | | | | | ^ | | | | | | | | | | | | +------------------------------------------------------+ | | | | |netfilter| | | | | | netfilter | | | | +----------+ +----------------------------+ | | | +-----------------------------------------------------------+ | | | | | | | out | | | | | | filter excute order | | | | | | +-----------------------------+ | | | | | | +-------------------> | | | | | | | | | | | | | | | | TCP | | | | +-----+--+-+ +-----v----+ +-----v----+ |pri +----+----+sec| | | | +------------+ +---+----+---v+rewriter++ +------------+ | | | | | | | | | | |in | |in | | | | | | | | | | | | | | | | filter | | filter | | filter +------> colo <------+ +--------> filter +--> adjust | adjust +--> filter | | | | | | mirror | |redirector| |redirector| | | compare | | | | | | redirector | | ack | seq | | redirector | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +----^-----+ +----+-----+ +----------+ | +---------+ | | | | +------------+ +--------+--------------+ +---+--------+ | | | | | tx | rx rx | | | | | tx all | rx | | | | | | | | | | +-----------------------------------------------------------+ | | | | +--------------+ | | | | | | | | | filter excute order | | | | | | | | | | +----------------> | | | +--------------------------------------------------------+ | | +-----------------------------------------+ | | | | | | | | | +--------------------------------------------------------------+ +----------------------------------------------------------------+ |guest receive | guest send | | +--------+----------------------------v------------------------+ | | NOTE: filter direction is rx/tx/all | tap | rx:receive packets sent to the netdev | | tx:receive packets sent by the netdev +--------------------------------------------------------------+ In COLO-compare, we do packet comparing job. Packets coming from the primary char indev will be sent to outdev. Packets coming from the secondary char dev will be dropped after comparing. colo-comapre need two input chardev and one output chardev: primary_in=chardev1-id (source: primary send packet) secondary_in=chardev2-id (source: secondary send packet) outdev=chardev3-id usage: primary: -netdev tap,id=hn0,vhost=off,script=/etc/qemu-ifup,downscript=/etc/qemu-ifdown -device e1000,id=e0,netdev=hn0,mac=52:a4:00:12:78:66 -chardev socket,id=mirror0,host=3.3.3.3,port=9003,server,nowait -chardev socket,id=compare1,host=3.3.3.3,port=9004,server,nowait -chardev socket,id=compare0,host=3.3.3.3,port=9001,server,nowait -chardev socket,id=compare0-0,host=3.3.3.3,port=9001 -chardev socket,id=compare_out,host=3.3.3.3,port=9005,server,nowait -chardev socket,id=compare_out0,host=3.3.3.3,port=9005 -object filter-mirror,id=m0,netdev=hn0,queue=tx,outdev=mirror0 -object filter-redirector,netdev=hn0,id=redire0,queue=rx,indev=compare_out -object filter-redirector,netdev=hn0,id=redire1,queue=rx,outdev=compare0 -object colo-compare,id=comp0,primary_in=compare0-0,secondary_in=compare1,outdev=compare_out0 secondary: -netdev tap,id=hn0,vhost=off,script=/etc/qemu-ifup,down script=/etc/qemu-ifdown -device e1000,netdev=hn0,mac=52:a4:00:12:78:66 -chardev socket,id=red0,host=3.3.3.3,port=9003 -chardev socket,id=red1,host=3.3.3.3,port=9004 -object filter-redirector,id=f1,netdev=hn0,queue=tx,indev=red0 -object filter-redirector,id=f2,netdev=hn0,queue=rx,outdev=red1 Signed-off-by: Zhang Chen <zhangchen.fnst@cn.fujitsu.com> Signed-off-by: Li Zhijian <lizhijian@cn.fujitsu.com> Signed-off-by: Wen Congyang <wency@cn.fujitsu.com> Signed-off-by: Jason Wang <jasowang@redhat.com>
2016-09-27 10:22:26 +08:00
Colo-compare gets packet from primary_in@var{chardevid} and secondary_in@var{chardevid}, than compare primary packet with
secondary packet. If the packets are same, we will output primary
packet to outdev@var{chardevid}, else we will notify colo-frame
do checkpoint and send primary packet to outdev@var{chardevid}.
if it has the vnet_hdr_support flag, colo compare will send/recv packet with vnet_hdr_len.
colo-compare: introduce colo compare initialization This a COLO net ascii figure: Primary qemu Secondary qemu +--------------------------------------------------------------+ +----------------------------------------------------------------+ | +----------------------------------------------------------+ | | +-----------------------------------------------------------+ | | | | | | | | | | | guest | | | | guest | | | | | | | | | | | +-------^--------------------------+-----------------------+ | | +---------------------+--------+----------------------------+ | | | | | | ^ | | | | | | | | | | | | +------------------------------------------------------+ | | | | |netfilter| | | | | | netfilter | | | | +----------+ +----------------------------+ | | | +-----------------------------------------------------------+ | | | | | | | out | | | | | | filter excute order | | | | | | +-----------------------------+ | | | | | | +-------------------> | | | | | | | | | | | | | | | | TCP | | | | +-----+--+-+ +-----v----+ +-----v----+ |pri +----+----+sec| | | | +------------+ +---+----+---v+rewriter++ +------------+ | | | | | | | | | | |in | |in | | | | | | | | | | | | | | | | filter | | filter | | filter +------> colo <------+ +--------> filter +--> adjust | adjust +--> filter | | | | | | mirror | |redirector| |redirector| | | compare | | | | | | redirector | | ack | seq | | redirector | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +----^-----+ +----+-----+ +----------+ | +---------+ | | | | +------------+ +--------+--------------+ +---+--------+ | | | | | tx | rx rx | | | | | tx all | rx | | | | | | | | | | +-----------------------------------------------------------+ | | | | +--------------+ | | | | | | | | | filter excute order | | | | | | | | | | +----------------> | | | +--------------------------------------------------------+ | | +-----------------------------------------+ | | | | | | | | | +--------------------------------------------------------------+ +----------------------------------------------------------------+ |guest receive | guest send | | +--------+----------------------------v------------------------+ | | NOTE: filter direction is rx/tx/all | tap | rx:receive packets sent to the netdev | | tx:receive packets sent by the netdev +--------------------------------------------------------------+ In COLO-compare, we do packet comparing job. Packets coming from the primary char indev will be sent to outdev. Packets coming from the secondary char dev will be dropped after comparing. colo-comapre need two input chardev and one output chardev: primary_in=chardev1-id (source: primary send packet) secondary_in=chardev2-id (source: secondary send packet) outdev=chardev3-id usage: primary: -netdev tap,id=hn0,vhost=off,script=/etc/qemu-ifup,downscript=/etc/qemu-ifdown -device e1000,id=e0,netdev=hn0,mac=52:a4:00:12:78:66 -chardev socket,id=mirror0,host=3.3.3.3,port=9003,server,nowait -chardev socket,id=compare1,host=3.3.3.3,port=9004,server,nowait -chardev socket,id=compare0,host=3.3.3.3,port=9001,server,nowait -chardev socket,id=compare0-0,host=3.3.3.3,port=9001 -chardev socket,id=compare_out,host=3.3.3.3,port=9005,server,nowait -chardev socket,id=compare_out0,host=3.3.3.3,port=9005 -object filter-mirror,id=m0,netdev=hn0,queue=tx,outdev=mirror0 -object filter-redirector,netdev=hn0,id=redire0,queue=rx,indev=compare_out -object filter-redirector,netdev=hn0,id=redire1,queue=rx,outdev=compare0 -object colo-compare,id=comp0,primary_in=compare0-0,secondary_in=compare1,outdev=compare_out0 secondary: -netdev tap,id=hn0,vhost=off,script=/etc/qemu-ifup,down script=/etc/qemu-ifdown -device e1000,netdev=hn0,mac=52:a4:00:12:78:66 -chardev socket,id=red0,host=3.3.3.3,port=9003 -chardev socket,id=red1,host=3.3.3.3,port=9004 -object filter-redirector,id=f1,netdev=hn0,queue=tx,indev=red0 -object filter-redirector,id=f2,netdev=hn0,queue=rx,outdev=red1 Signed-off-by: Zhang Chen <zhangchen.fnst@cn.fujitsu.com> Signed-off-by: Li Zhijian <lizhijian@cn.fujitsu.com> Signed-off-by: Wen Congyang <wency@cn.fujitsu.com> Signed-off-by: Jason Wang <jasowang@redhat.com>
2016-09-27 10:22:26 +08:00
we must use it with the help of filter-mirror and filter-redirector.
@example
primary:
-netdev tap,id=hn0,vhost=off,script=/etc/qemu-ifup,downscript=/etc/qemu-ifdown
-device e1000,id=e0,netdev=hn0,mac=52:a4:00:12:78:66
-chardev socket,id=mirror0,host=3.3.3.3,port=9003,server,nowait
-chardev socket,id=compare1,host=3.3.3.3,port=9004,server,nowait
-chardev socket,id=compare0,host=3.3.3.3,port=9001,server,nowait
-chardev socket,id=compare0-0,host=3.3.3.3,port=9001
-chardev socket,id=compare_out,host=3.3.3.3,port=9005,server,nowait
-chardev socket,id=compare_out0,host=3.3.3.3,port=9005
-object filter-mirror,id=m0,netdev=hn0,queue=tx,outdev=mirror0
-object filter-redirector,netdev=hn0,id=redire0,queue=rx,indev=compare_out
-object filter-redirector,netdev=hn0,id=redire1,queue=rx,outdev=compare0
-object colo-compare,id=comp0,primary_in=compare0-0,secondary_in=compare1,outdev=compare_out0
secondary:
-netdev tap,id=hn0,vhost=off,script=/etc/qemu-ifup,down script=/etc/qemu-ifdown
-device e1000,netdev=hn0,mac=52:a4:00:12:78:66
-chardev socket,id=red0,host=3.3.3.3,port=9003
-chardev socket,id=red1,host=3.3.3.3,port=9004
-object filter-redirector,id=f1,netdev=hn0,queue=tx,indev=red0
-object filter-redirector,id=f2,netdev=hn0,queue=rx,outdev=red1
@end example
If you want to know the detail of above command line, you can read
the colo-compare git log.
@item -object cryptodev-backend-builtin,id=@var{id}[,queues=@var{queues}]
Creates a cryptodev backend which executes crypto opreation from
the QEMU cipher APIS. The @var{id} parameter is
a unique ID that will be used to reference this cryptodev backend from
the @option{virtio-crypto} device. The @var{queues} parameter is optional,
which specify the queue number of cryptodev backend, the default of
@var{queues} is 1.
@example
# qemu-system-x86_64 \
[...] \
-object cryptodev-backend-builtin,id=cryptodev0 \
-device virtio-crypto-pci,id=crypto0,cryptodev=cryptodev0 \
[...]
@end example
crypto: add QCryptoSecret object class for password/key handling Introduce a new QCryptoSecret object class which will be used for providing passwords and keys to other objects which need sensitive credentials. The new object can provide secret values directly as properties, or indirectly via a file. The latter includes support for file descriptor passing syntax on UNIX platforms. Ordinarily passing secret values directly as properties is insecure, since they are visible in process listings, or in log files showing the CLI args / QMP commands. It is possible to use AES-256-CBC to encrypt the secret values though, in which case all that is visible is the ciphertext. For ad hoc developer testing though, it is fine to provide the secrets directly without encryption so this is not explicitly forbidden. The anticipated scenario is that libvirtd will create a random master key per QEMU instance (eg /var/run/libvirt/qemu/$VMNAME.key) and will use that key to encrypt all passwords it provides to QEMU via '-object secret,....'. This avoids the need for libvirt (or other mgmt apps) to worry about file descriptor passing. It also makes life easier for people who are scripting the management of QEMU, for whom FD passing is significantly more complex. Providing data inline (insecure, only for ad hoc dev testing) $QEMU -object secret,id=sec0,data=letmein Providing data indirectly in raw format printf "letmein" > mypasswd.txt $QEMU -object secret,id=sec0,file=mypasswd.txt Providing data indirectly in base64 format $QEMU -object secret,id=sec0,file=mykey.b64,format=base64 Providing data with encryption $QEMU -object secret,id=master0,file=mykey.b64,format=base64 \ -object secret,id=sec0,data=[base64 ciphertext],\ keyid=master0,iv=[base64 IV],format=base64 Note that 'format' here refers to the format of the ciphertext data. The decrypted data must always be in raw byte format. More examples are shown in the updated docs. Reviewed-by: Eric Blake <eblake@redhat.com> Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2015-10-14 16:58:38 +08:00
@item -object secret,id=@var{id},data=@var{string},format=@var{raw|base64}[,keyid=@var{secretid},iv=@var{string}]
@item -object secret,id=@var{id},file=@var{filename},format=@var{raw|base64}[,keyid=@var{secretid},iv=@var{string}]
Defines a secret to store a password, encryption key, or some other sensitive
data. The sensitive data can either be passed directly via the @var{data}
parameter, or indirectly via the @var{file} parameter. Using the @var{data}
parameter is insecure unless the sensitive data is encrypted.
The sensitive data can be provided in raw format (the default), or base64.
When encoded as JSON, the raw format only supports valid UTF-8 characters,
so base64 is recommended for sending binary data. QEMU will convert from
which ever format is provided to the format it needs internally. eg, an
RBD password can be provided in raw format, even though it will be base64
encoded when passed onto the RBD sever.
For added protection, it is possible to encrypt the data associated with
a secret using the AES-256-CBC cipher. Use of encryption is indicated
by providing the @var{keyid} and @var{iv} parameters. The @var{keyid}
parameter provides the ID of a previously defined secret that contains
the AES-256 decryption key. This key should be 32-bytes long and be
base64 encoded. The @var{iv} parameter provides the random initialization
vector used for encryption of this particular secret and should be a
base64 encrypted string of the 16-byte IV.
crypto: add QCryptoSecret object class for password/key handling Introduce a new QCryptoSecret object class which will be used for providing passwords and keys to other objects which need sensitive credentials. The new object can provide secret values directly as properties, or indirectly via a file. The latter includes support for file descriptor passing syntax on UNIX platforms. Ordinarily passing secret values directly as properties is insecure, since they are visible in process listings, or in log files showing the CLI args / QMP commands. It is possible to use AES-256-CBC to encrypt the secret values though, in which case all that is visible is the ciphertext. For ad hoc developer testing though, it is fine to provide the secrets directly without encryption so this is not explicitly forbidden. The anticipated scenario is that libvirtd will create a random master key per QEMU instance (eg /var/run/libvirt/qemu/$VMNAME.key) and will use that key to encrypt all passwords it provides to QEMU via '-object secret,....'. This avoids the need for libvirt (or other mgmt apps) to worry about file descriptor passing. It also makes life easier for people who are scripting the management of QEMU, for whom FD passing is significantly more complex. Providing data inline (insecure, only for ad hoc dev testing) $QEMU -object secret,id=sec0,data=letmein Providing data indirectly in raw format printf "letmein" > mypasswd.txt $QEMU -object secret,id=sec0,file=mypasswd.txt Providing data indirectly in base64 format $QEMU -object secret,id=sec0,file=mykey.b64,format=base64 Providing data with encryption $QEMU -object secret,id=master0,file=mykey.b64,format=base64 \ -object secret,id=sec0,data=[base64 ciphertext],\ keyid=master0,iv=[base64 IV],format=base64 Note that 'format' here refers to the format of the ciphertext data. The decrypted data must always be in raw byte format. More examples are shown in the updated docs. Reviewed-by: Eric Blake <eblake@redhat.com> Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2015-10-14 16:58:38 +08:00
The simplest (insecure) usage is to provide the secret inline
@example
# $QEMU -object secret,id=sec0,data=letmein,format=raw
@end example
The simplest secure usage is to provide the secret via a file
tests: Avoid non-portable 'echo -ARG' POSIX says that backslashes in the arguments to 'echo', as well as any use of 'echo -n' and 'echo -e', are non-portable; it recommends people should favor 'printf' instead. This is definitely true where we do not control which shell is running (such as in makefile snippets or in documentation examples). But even for scripts where we require bash (and therefore, where echo does what we want by default), it is still possible to use 'shopt -s xpg_echo' to change bash's behavior of echo. And setting a good example never hurts when we are not sure if a snippet will be copied from a bash-only script to a general shell script (although I don't change the use of non-portable \e for ESC when we know the running shell is bash). Replace 'echo -n "..."' with 'printf %s "..."', and 'echo -e "..."' with 'printf %b "...\n"', with the optimization that the %s/%b argument can be omitted if the string being printed is a strict literal with no '%', '$', or '`' (we could technically also make this optimization when there are $ or `` substitutions but where we can prove their results will not be problematic, but proving that such substitutions are safe makes the patch less trivial compared to just being consistent). In the qemu-iotests check script, fix unusual shell quoting that would result in word-splitting if 'date' outputs a space. In test 051, take an opportunity to shorten the line. In test 068, get rid of a pointless second invocation of bash. CC: qemu-trivial@nongnu.org Signed-off-by: Eric Blake <eblake@redhat.com> Message-id: 20170703180950.9895-1-eblake@redhat.com Signed-off-by: Max Reitz <mreitz@redhat.com>
2017-07-04 02:09:50 +08:00
# printf "letmein" > mypasswd.txt
crypto: add QCryptoSecret object class for password/key handling Introduce a new QCryptoSecret object class which will be used for providing passwords and keys to other objects which need sensitive credentials. The new object can provide secret values directly as properties, or indirectly via a file. The latter includes support for file descriptor passing syntax on UNIX platforms. Ordinarily passing secret values directly as properties is insecure, since they are visible in process listings, or in log files showing the CLI args / QMP commands. It is possible to use AES-256-CBC to encrypt the secret values though, in which case all that is visible is the ciphertext. For ad hoc developer testing though, it is fine to provide the secrets directly without encryption so this is not explicitly forbidden. The anticipated scenario is that libvirtd will create a random master key per QEMU instance (eg /var/run/libvirt/qemu/$VMNAME.key) and will use that key to encrypt all passwords it provides to QEMU via '-object secret,....'. This avoids the need for libvirt (or other mgmt apps) to worry about file descriptor passing. It also makes life easier for people who are scripting the management of QEMU, for whom FD passing is significantly more complex. Providing data inline (insecure, only for ad hoc dev testing) $QEMU -object secret,id=sec0,data=letmein Providing data indirectly in raw format printf "letmein" > mypasswd.txt $QEMU -object secret,id=sec0,file=mypasswd.txt Providing data indirectly in base64 format $QEMU -object secret,id=sec0,file=mykey.b64,format=base64 Providing data with encryption $QEMU -object secret,id=master0,file=mykey.b64,format=base64 \ -object secret,id=sec0,data=[base64 ciphertext],\ keyid=master0,iv=[base64 IV],format=base64 Note that 'format' here refers to the format of the ciphertext data. The decrypted data must always be in raw byte format. More examples are shown in the updated docs. Reviewed-by: Eric Blake <eblake@redhat.com> Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2015-10-14 16:58:38 +08:00
# $QEMU -object secret,id=sec0,file=mypasswd.txt,format=raw
For greater security, AES-256-CBC should be used. To illustrate usage,
consider the openssl command line tool which can encrypt the data. Note
that when encrypting, the plaintext must be padded to the cipher block
size (32 bytes) using the standard PKCS#5/6 compatible padding algorithm.
First a master key needs to be created in base64 encoding:
@example
# openssl rand -base64 32 > key.b64
# KEY=$(base64 -d key.b64 | hexdump -v -e '/1 "%02X"')
@end example
Each secret to be encrypted needs to have a random initialization vector
generated. These do not need to be kept secret
@example
# openssl rand -base64 16 > iv.b64
# IV=$(base64 -d iv.b64 | hexdump -v -e '/1 "%02X"')
@end example
The secret to be defined can now be encrypted, in this case we're
telling openssl to base64 encode the result, but it could be left
as raw bytes if desired.
@example
tests: Avoid non-portable 'echo -ARG' POSIX says that backslashes in the arguments to 'echo', as well as any use of 'echo -n' and 'echo -e', are non-portable; it recommends people should favor 'printf' instead. This is definitely true where we do not control which shell is running (such as in makefile snippets or in documentation examples). But even for scripts where we require bash (and therefore, where echo does what we want by default), it is still possible to use 'shopt -s xpg_echo' to change bash's behavior of echo. And setting a good example never hurts when we are not sure if a snippet will be copied from a bash-only script to a general shell script (although I don't change the use of non-portable \e for ESC when we know the running shell is bash). Replace 'echo -n "..."' with 'printf %s "..."', and 'echo -e "..."' with 'printf %b "...\n"', with the optimization that the %s/%b argument can be omitted if the string being printed is a strict literal with no '%', '$', or '`' (we could technically also make this optimization when there are $ or `` substitutions but where we can prove their results will not be problematic, but proving that such substitutions are safe makes the patch less trivial compared to just being consistent). In the qemu-iotests check script, fix unusual shell quoting that would result in word-splitting if 'date' outputs a space. In test 051, take an opportunity to shorten the line. In test 068, get rid of a pointless second invocation of bash. CC: qemu-trivial@nongnu.org Signed-off-by: Eric Blake <eblake@redhat.com> Message-id: 20170703180950.9895-1-eblake@redhat.com Signed-off-by: Max Reitz <mreitz@redhat.com>
2017-07-04 02:09:50 +08:00
# SECRET=$(printf "letmein" |
crypto: add QCryptoSecret object class for password/key handling Introduce a new QCryptoSecret object class which will be used for providing passwords and keys to other objects which need sensitive credentials. The new object can provide secret values directly as properties, or indirectly via a file. The latter includes support for file descriptor passing syntax on UNIX platforms. Ordinarily passing secret values directly as properties is insecure, since they are visible in process listings, or in log files showing the CLI args / QMP commands. It is possible to use AES-256-CBC to encrypt the secret values though, in which case all that is visible is the ciphertext. For ad hoc developer testing though, it is fine to provide the secrets directly without encryption so this is not explicitly forbidden. The anticipated scenario is that libvirtd will create a random master key per QEMU instance (eg /var/run/libvirt/qemu/$VMNAME.key) and will use that key to encrypt all passwords it provides to QEMU via '-object secret,....'. This avoids the need for libvirt (or other mgmt apps) to worry about file descriptor passing. It also makes life easier for people who are scripting the management of QEMU, for whom FD passing is significantly more complex. Providing data inline (insecure, only for ad hoc dev testing) $QEMU -object secret,id=sec0,data=letmein Providing data indirectly in raw format printf "letmein" > mypasswd.txt $QEMU -object secret,id=sec0,file=mypasswd.txt Providing data indirectly in base64 format $QEMU -object secret,id=sec0,file=mykey.b64,format=base64 Providing data with encryption $QEMU -object secret,id=master0,file=mykey.b64,format=base64 \ -object secret,id=sec0,data=[base64 ciphertext],\ keyid=master0,iv=[base64 IV],format=base64 Note that 'format' here refers to the format of the ciphertext data. The decrypted data must always be in raw byte format. More examples are shown in the updated docs. Reviewed-by: Eric Blake <eblake@redhat.com> Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2015-10-14 16:58:38 +08:00
openssl enc -aes-256-cbc -a -K $KEY -iv $IV)
@end example
When launching QEMU, create a master secret pointing to @code{key.b64}
and specify that to be used to decrypt the user password. Pass the
contents of @code{iv.b64} to the second secret
@example
# $QEMU \
-object secret,id=secmaster0,format=base64,file=key.b64 \
-object secret,id=sec0,keyid=secmaster0,format=base64,\
data=$SECRET,iv=$(<iv.b64)
@end example
@end table
ETEXI
HXCOMM This is the last statement. Insert new options before this line!