Commit Graph

114175 Commits

Author SHA1 Message Date
Richard Sandiford
b5b4f66545 aarch64: Try to report invalid variants against the closest match
If an instruction has invalid qualifiers, GAS would report the
error against the final opcode entry that got to the qualifier-
checking stage.  It seems better to report the error against
the opcode entry that had the closest match, just like we
pick the closest match within an opcode entry for the
"did you mean this?" message.

This patch adds the number of invalid operands as an
argument to AARCH64_OPDE_INVALID_VARIANT and then picks the
AARCH64_OPDE_INVALID_VARIANT with the lowest argument.
2023-03-30 11:09:08 +01:00
Richard Sandiford
8c2216b277 aarch64: Tweak register list errors
The error for invalid register lists had the form:

  invalid number of registers in the list; N registers are expected at operand M -- `insn'

This seems a bit verbose.  Also, the "bracketing" is really:

  (invalid number of registers in the list; N registers are expected) at operand M

but the semicolon works against that.

This patch goes for slightly shorter messages, setting a template
that later patches can use for more complex cases.
2023-03-30 11:09:08 +01:00
Richard Sandiford
38c5aa5e88 aarch64: Make AARCH64_OPDE_REG_LIST take a bitfield
AARCH64_OPDE_REG_LIST took a single operand that specified the
expected number of registers.  However, there are quite a few
SME2 instructions that have both 2-register forms and (separate)
4-register forms.  If the user tries to use a 3-register list,
it isn't obvious which opcode entry they meant.  Saying that we
expect 2 registers and saying that we expect 4 registers would
both be wrong.

This patch therefore switches the operand to a bitfield.  If a
AARCH64_OPDE_REG_LIST is reported against multiple opcode entries,
the patch ORs up the expected lengths.

This has no user-visible effect yet.  A later patch adds more error
strings, alongside tests that use them.
2023-03-30 11:09:08 +01:00
Richard Sandiford
db3c06bf93 aarch64: Add an operand class for SVE register lists
SVE register lists were classified as SVE_REG, since there had been
no particular reason to separate them out.  However, some SME2
instructions have tied register list operands, and so we need to
distinguish registers and register lists when checking whether two
operands match.

Also, the register list operands used a general error message,
even though we already have a dedicated error code for register
lists that are the wrong length.
2023-03-30 11:09:07 +01:00
Richard Sandiford
56ead579a5 aarch64: Commonise checks for index operands
This patch splits out the constraint checking for index operands,
so that it can be reused by new SME2 operands.
2023-03-30 11:09:07 +01:00
Richard Sandiford
859f51df4d aarch64: Add an error code for out-of-range registers
libopcodes currently reports out-of-range registers as a general
AARCH64_OPDE_OTHER_ERROR.  However, this means that each register
range needs its own hard-coded string, which is a bit cumbersome
if the range is determined programmatically.  This patch therefore
adds a dedicated error type for out-of-range errors.
2023-03-30 11:09:07 +01:00
Richard Sandiford
36043bcff4 aarch64: Deprioritise AARCH64_OPDE_REG_LIST
SME2 has many instructions that take a list of SVE registers.
There are often multiple forms, with different forms taking
different numbers of registers.

This means that if, after a successful parse and qualifier match,
we find that the number of registers does not match the opcode entry,
the associated error should have a lower priority/severity than other
errors reported at the same stage.  For example, if there are 2-register
and 4-register forms of an instruction, and if the assembly code uses
the 2-register form with an out-of-range value, the out-of-range value
error against the 2-register instruction should have a higher priority
than the "wrong number of registers" error against the 4-register
instruction.

This is tested by the main SME2 patches, but seemed worth splitting out.
2023-03-30 11:09:07 +01:00
Richard Sandiford
c1817dc2ee aarch64: Update operand_mismatch_kind_names
The contents of operand_mismatch_kind_names were out of sync
with the enum.
2023-03-30 11:09:07 +01:00
Richard Sandiford
e426521ed1 aarch64: Rework reporting of failed register checks
There are many opcode table entries that share the same mnemonic.
Trying to parse an invalid assembly line will trigger an error for
each of these entries, but the specific error might vary from one
entry to another, depending on the exact nature of the problem.

GAS has quite an elaborate system for picking the most appropriate
error out of all the failed matches.  And in many cases it works well.
However, one of the limitations is that the error is always reported
against a single opcode table entry.  If that table entry isn't the
one that the user intended to use, then the error can end up being
overly specific.

This is particularly true if an instruction has a typoed register
name, or uses a type of register that is not accepted by any
opcode table entry.  For example, one of the expected error
matches for an attempted SVE2 instruction is:

  Error: operand 1 must be a SIMD scalar register -- `addp z32\.s,p0/m,z32\.s,z0\.s'

even though the hypothetical user was presumably attempting to use
the SVE form of ADDP rather than the Advanced SIMD one.  There are
many other instances of this in the testsuite.

The problem becomes especially acute with SME2, since many SME2
instructions reuse existing mnemonics.  This could lead to us
reporting an SME-related error against a non-SME instruction,
or a non-SME-related error against an SME instruction.

This patch tries to improve things by collecting together all
the register types that an opcode table entry expected for a
given operand.  It also records what kind of register was
actually seen, if any.  It then tries to summarise all this
in a more directed way, falling back to a generic error if
the combination defies a neat summary.

The patch includes tests for all new messages except REG_TYPE_ZA,
which only triggers with SME2.

To test this, I created an assembly file that contained the cross
product of all known mnemonics and one example from each register
class.  I then looked for cases where the new routines fell back on the
generic errors ("expected a register" or "unexpected register type").
I locally added dummy messages for each one until there were no
more hits.  The patch adds a specimen instruction to diagnostics.s
for each of these combinations.  In each case, the combination didn't
seem like something that could be summarised in a natural way, so the
generic messages seemed better.  There's always going to be an element
of personal taste around this kind of thing though.

Adding more register types made 1<<REG_TYPE_MAX exceed the range
of the type, but we don't actually need/want 1<<REG_TYPE_MAX.
2023-03-30 11:09:06 +01:00
Richard Sandiford
405f0c4131 aarch64: Try to avoid inappropriate default errors
After parsing a '{' and the first register, parse_typed_reg would
report errors in subsequent registers in the same way as for the
first register.  It used set_default_error, which reports errors
of the form "operand N must be X".

The problem is that if there are multiple opcode entries for the
same mnemonic, there could be several matches that lead to a
default error.  There's no guarantee that the default error for
the register list is the one that will be chosen.

To take an example from the testsuite:

    ext z0.b,{z31.b,z32.b},#0

gave:

    operand 2 must be an SVE vector register

with the error being reported against the single-vector version
of ext, even though the operand is clearly a list.

This patch uses set_fatal_syntax_error to bump the priority of the
error once we're sure that the operand is a list of the right type.
2023-03-30 11:09:06 +01:00
Richard Sandiford
b9ca389690 aarch64: Improve errors for malformed register lists
parse_typed_reg is used for parsing both bare registers and
registers that occur in lists.  If it doesn't see a register,
or sees an unexpected kind of register, it queues a default
error to report the problem.  These default errors have the form
"operand N must be an X", where X comes from the operand table.

If there are multiple opcode entries that report default errors,
GAS tries to pick the most appropriate one, using the opcode
table order as a tiebreaker.  But this can lead to cases where
a syntax error in a register list is reported against an opcode
that doesn't accept register lists.  For example, the unlikely
error:

  ext z0.b,{,},#0

is reported as:

  operand 2 must be an SVE vector register -- `ext z0.b,{,},#0'

even though operand 2 can be a register list.

If we've parsed the opening '{' of a register list, and then see
something that isn't remotely register-like, it seems better to
report that directly as a syntax error, rather than rely on the
default error.  The operand won't be a valid list of anything,
so there's no need to pick a specific Y in "operand N must be
a list of Y".
2023-03-30 11:09:06 +01:00
Richard Sandiford
30ba1d7e2f aarch64: Tweak parsing of integer & FP registers
Integer registers were parsed indirectly through
aarch64_reg_parse_32_64 (and thus aarch64_addr_reg_parse) rather
than directly through parse_reg.  This was because we need the
qualifier associated with the register, and the logic to calculate
that was buried in aarch64_addr_reg_parse.

The code that parses FP registers had the same need, but it
open-coded the calculation of the qualifier.

This patch tries to handle both cases in the same way.  It is
needed by a later patch that tries to improve the register-related
diagnostics.
2023-03-30 11:09:06 +01:00
Richard Sandiford
72c1dab0ea aarch64: Tweak errors for base & offset registers
parse_address_main currently uses get_reg_expected_msg to
report invalid base and offset registers, but the disadvantage
of doing that is that it isn't immediately clear which register
is wrong (the base or the offset).

A later patch moves away from using get_reg_expected_msg for failed
type checks, but doing that here didn't seem like the best approach.
The patch tries to use more tailored messages instead.
2023-03-30 11:09:06 +01:00
Richard Sandiford
f42fba9879 aarch64: Tweak error for missing immediate offset
This patch tweaks the error message that is printed when
a ZA-style index is missing the immediate offset.
2023-03-30 11:09:05 +01:00
Richard Sandiford
7da28504bf aarch64: Move w12-w15 range check to libopcodes
In SME, the vector select register had to be in the range
w12-w15, so it made sense to enforce that during parsing.
However, SME2 adds instructions for which the range is
w8-w11 instead.

This patch therefore moves the range check from the parsing
stage to the constraint-checking stage.

Also, the previous error used a capitalised range W12-W15,
whereas other register range errors used lowercase ranges
like p0-p7.  A quick internal poll showed a preference for
the lowercase form, so the patch uses that.

The patch uses "selection register" rather than "vector
select register" so that the terminology extends more
naturally to PSEL.
2023-03-30 11:09:05 +01:00
Richard Sandiford
61dac77e93 aarch64: Commonise index parsing
Just a minor clean-up to factor out the index parsing, partly to
ensure that the error handling remains consistent.  No behavioural
change intended.
2023-03-30 11:09:05 +01:00
Richard Sandiford
9d86238266 aarch64: Consolidate ZA slice parsing
Now that parse_typed_reg checks the range of tile register numbers
and libopcodes checks the range of vector select offsets, there's
very little difference between the parsing of ZA tile indices,
ZA array indices, and PSEL indices.  The main one is that ZA
array indices don't currently allow "za" to be qualified,
but we need to remove that restriction for SME2.

This patch therefore consolidates all three parsers into a single
routine, parameterised by the type of register that they expect.
2023-03-30 11:09:05 +01:00
Richard Sandiford
ff60bcbfbe aarch64: Move ZA range checks to aarch64-opc.c
This patch moves the range checks on ZA vector select offsets from
gas to libopcodes.  Doing the checks there means that the error
messages contain the expected range.  It also fits in better
with the error severity scheme, which becomes important later.
(This is because out-of-range indices are treated as more severe than
syntax errors, on the basis that parsing must have succeeded if we get
to the point of checking the completed opcode.)

The patch also adds a new check_za_access function for checking
ZA accesses.  That's a bit over the top for one offset check, but the
function becomes more complex with later patches.

sme-9-illegal.s checked for an invalid .q suffix using:

  psel p1, p15, p3.q[w15]

but this is doubly invalid because it misses the immediate part
of the index.  The patch keeps that test but adds another with
a zero index, so that .q is the only thing wrong.

The aarch64-tbl.h change includes neatening up the backslash
positions.
2023-03-30 11:09:05 +01:00
Richard Sandiford
1d597b88c8 aarch64: Pass aarch64_indexed_za to parsers
ZA indices have more parts than most operands, so passing these
parts around individually is more awkward than for other operand
types.  Things aren't too bad at the moment, but SME2 adds two
further pieces: an offset range and a vector group size.

This patch therefore replaces arguments for the individual pieces
with a single argument for the index as a whole.
2023-03-30 11:09:04 +01:00
Richard Sandiford
c888354c61 aarch64: Make indexed_za use 64-bit immediates
A later patch moves the range checking for ZA vector select
offsets from gas to libopcodes.  That in turn requires the
immediate field to be big enough to support all parsed values.

This shouldn't be a particularly size-sensitive structure,
so there should be no memory problems with doing this.
2023-03-30 11:09:04 +01:00
Richard Sandiford
575c497a4a aarch64: Rename za_tile_vector to za_index
za_tile_vector is also used for indexing ZA as a whole, rather than
just for indexing tiles.  The former is more common than the latter
in SME2, so this patch generalises the name to "indexed_za".

The patch also names the associated structure, so that later patches
can reuse it during parsing.
2023-03-30 11:09:04 +01:00
Richard Sandiford
e9e1ddbb98 aarch64: Treat ZA as a register
We already treat the ZA tiles ZA0-ZA15 as registers.  This patch
does the same for ZA itself.  parse_sme_zero_mask can then parse
ZA tiles and ZA in the same way, through parsed_type_reg.

One important effect of going through parsed_type_reg (in general)
is that it allows ZA to take qualifiers.  This is necessary for many
SME2 instructions.

However, to support existing unqualified uses of ZA, parse_reg_with_qual
needs to treat the qualiier as optional.  Hopefully the net effect is
to give better error messages, since now that SME2 makes "za.<T>"
valid in some contexts, it might be natural to use it (incorrectly)
in ZERO too.

While there, the patch also tweaks the error messages for invalid
ZA tiles, to try to make some cases more specific.

For now, parse_sme_za_array just uses parse_reg, rather than
parse_typed_reg/parse_reg_with_qual.  A later patch consolidates
the parsing further.
2023-03-30 11:09:04 +01:00
Richard Sandiford
8cde0b988a aarch64: Consolidate ZA tile range checks
Now that all parsing of ZA tile names goes through parse_typed_reg,
we can check there for out-of-range tile numbers.  The other check
performed by parse_sme_zada_operand was to reject .q, but that can
now be done via F_STRICT instead.  (.q tiles are valid in other
contexts, so they shouldn't be rejected in parse_typed_reg.)
2023-03-30 11:09:04 +01:00
Richard Sandiford
c211f26867 aarch64: Reuse parse_typed_reg for ZA tiles
This patch reuses the general parse_typed_reg for ZA tiles.
This involves adding a way of suppressing the usual treatment
of register indices, since ZA indices look very different from
Advanced SIMD and SVE vector indices.
2023-03-30 11:09:03 +01:00
Richard Sandiford
074c89d29b aarch64: Rework parse_typed_reg interface
parse_typed_reg returned a register number and passed the
register type back using a pointer parameter.  It seems simpler
to return the register entry instead, since that has both pieces
of information in one place.

The patch also replaces the boolean in_reg_list parameter with
a mask of flags.  This hopefully makes calls easier to read
(more self-documenting than "true" or "false"), but more
importantly, it allows a later patch to add a second flag.
2023-03-30 11:09:03 +01:00
Richard Sandiford
363c5c8b97 aarch64: Move vectype_to_qualifier further up
This patch just moves vectype_to_qualifier further up, so that
a later patch can call it at an earlier point in the file.
No behavioural change intended.
2023-03-30 11:09:03 +01:00
Richard Sandiford
83dbd40dea aarch64: Add REG_TYPE_ZATHV
This patch adds a multi-register type that includes both REG_TYPE_ZATH
and REG_TYPE_ZATV.  This slightly simplifies the existing code, but the
main purpose is to enable later patches.
2023-03-30 11:09:03 +01:00
Richard Sandiford
fd855fbb37 aarch64: Rename REG_TYPE_ZA* to REG_TYPE_ZAT*
The ZA tile registers were called REG_TYPE_ZA, REG_TYPE_ZAH and
REG_TYPE_ZAV.  However, a later patch wants to make plain "za"
a register type too, and REG_TYPE_ZA is the obvious name for that.

This patch therefore adds "T" (tile) to the existing names.
2023-03-30 11:09:03 +01:00
Richard Sandiford
3e4525ca0b aarch64: Use aarch64_operand_error more widely
GAS's aarch64_instruction had its own cut-down error record,
but it's better for later patches if it reuses the binutils-wide
aarch64_operand_error instead.  The main difference is that
aarch64_operand_error can store arguments to the error while
aarch64_instruction couldn't.
2023-03-30 11:09:02 +01:00
Richard Sandiford
a5791d5814 aarch64: Make SME instructions use F_STRICT
This patch makes all SME instructions use F_STRICT, so that qualifiers
have to be provided explicitly rather than being inferred from other
operands.  The main change is to move the qualifier setting from the
operand-level decoders to the opcode level.

This is one step towards consolidating the ZA parsing code and
extending it to handle SME2.
2023-03-30 11:09:02 +01:00
Richard Sandiford
eee2ecccda aarch64: Fix SVE2 register/immediate distinction
GAS refuses to interpret register names like x0 as unadorned
immediates, due to the obvious potential for confusion with
register operands.  (An explicit #x0 is OK.)

For compatibility reasons, we can't extend the set of registers
that GAS rejects for existing instructions.  For example:

   mov x0, z0

was valid code before SVE was added, so it needs to stay valid
code even when SVE is enabled.  But we can make GAS reject newer
registers in newer instructions.  The SVE instruction:

   and z0.s, z0.s, z0.h

is therefore invalid, rather than z0.h being an immediate.

This patch extends the SVE behaviour to SVE2.  The old call
to AARCH64_CPU_HAS_FEATURE was technically the wrong way around,
although it didn't matter in practice for base SVE instructions
since their avariants only set SVE.
2023-03-30 11:09:02 +01:00
Richard Sandiford
89f55b440a aarch64: Restrict range of PRFM opcodes
In the register-index forms of PRFM, the unallocated prefetch opcodes
24-31 have been reused for the encoding of the new RPRFM instruction.
The PRFM opcode space is now capped at 23 for these forms.  The other
forms of PRFM are unaffected.
2023-03-30 11:09:02 +01:00
Richard Sandiford
d346e1aafd aarch64: Fix PSEL opcode mask
The opcode mask for PSEL was missing some bits, which meant
that some upcoming SME2 opcodes would be misinterpreted as PSELs.
2023-03-30 11:09:02 +01:00
Richard Sandiford
78addeae53 aarch64: Add sme-i16i64 and sme-f64f64 aliases
Most extension flags are named after the associated architectural
FEAT_* flags, but sme-i64 and sme-f64 were exceptions.  This patch
adds sme-i16i64 and sme-f64f64 aliases, but keeps the old names too
for compatibility.
2023-03-30 11:09:01 +01:00
Nick Clifton
8d17c53b8d Fix an illegal memory access triggered by parsing corrupt DWARF info.
PR 30284
  * dwarf.c (read_and_display_attr_value): Detect and ignore negative base values.
2023-03-30 11:04:53 +01:00
Andrew Burgess
3712e78cab gdb/python: Add new gdb.unwinder.FrameId class
When writing an unwinder it is necessary to create a new class to act
as a frame-id.  This new class is almost certainly just going to set a
'sp' and 'pc' attribute within the instance.

This commit adds a little helper class gdb.unwinder.FrameId that does
this job.  Users can make use of this to avoid having to write out
standard boilerplate code any time they write an unwinder.

Of course, if the user wants their FrameId class to be more
complicated in some way, then they can still write their own class,
just like they could before.

I've simplified the example code in the documentation to now use the
new helper class, and I've also made use of this helper within the
testsuite.

Any existing user code will continue to work just as it did before
after this change.

Reviewed-By: Eli Zaretskii <eliz@gnu.org>
Reviewed-By: Tom Tromey <tom@tromey.com>
2023-03-30 10:25:46 +01:00
Andrew Burgess
64826d05d3 gdb/python: Allow gdb.UnwindInfo to be created with non gdb.Value args
Currently when creating a gdb.UnwindInfo object a user must call
gdb.PendingFrame.create_unwind_info and pass a frame-id object.

The frame-id object should have at least a 'sp' attribute, and
probably a 'pc' attribute too (it can also, in some cases have a
'special' attribute).

Currently all of these frame-id attributes need to be gdb.Value
objects, but the only reason for that requirement is that we have some
code in py-unwind.c that only handles gdb.Value objects.

If instead we switch to using get_addr_from_python in py-utils.c then
we will support both gdb.Value objects and also raw numbers, which
might make things simpler in some cases.

So, I started rewriting pyuw_object_attribute_to_pointer (in
py-unwind.c) to use get_addr_from_python.  However, while looking at
the code I noticed a problem.

The pyuw_object_attribute_to_pointer function returns a boolean flag,
if everything goes OK we return true, but we return false in two
cases, (1) when the attribute is not present, which might be
acceptable, or might be an error, and (2) when we get an error trying
to extract the attribute value, in which case a Python error will have
been set.

Now in pending_framepy_create_unwind_info we have this code:

  if (!pyuw_object_attribute_to_pointer (pyo_frame_id, "sp", &sp))
    {
      PyErr_SetString (PyExc_ValueError,
		       _("frame_id should have 'sp' attribute."));
      return NULL;
    }

Notice how we always set an error.  This will override any error that
is already set.

So, if you create a frame-id object that has an 'sp' attribute, but
the attribute is not a gdb.Value, then currently we fail to extract
the attribute value (it's not a gdb.Value) and set this error in
pyuw_object_attribute_to_pointer:

  rc = pyuw_value_obj_to_pointer (pyo_value.get (), addr);
  if (!rc)
    PyErr_Format (
        PyExc_ValueError,
        _("The value of the '%s' attribute is not a pointer."),
        attr_name);

Then we return to pending_framepy_create_unwind_info and immediately
override this error with the error about 'sp' being missing.

This all feels very confused.

Here's my proposed solution: pyuw_object_attribute_to_pointer will now
return a tri-state enum, with states OK, MISSING, or ERROR.  The
meanings of these states are:

  OK - Attribute exists and was extracted fine,

  MISSING - Attribute doesn't exist, no Python error was set.

  ERROR - Attribute does exist, but there was an error while
     extracting it, a Python error was set.

We need to update pending_framepy_create_unwind_info, the only user of
pyuw_object_attribute_to_pointer, but now I think things are much
clearer.  Errors from lower levels are not blindly overridden with the
generic meaningless error message, but we still get the "missing 'sp'
attribute" error when appropriate.

This change also includes the switch to get_addr_from_python which was
what started this whole journey.

For well behaving user code there should be no visible changes after
this commit.

For user code that hits an error, hopefully the new errors should be
more helpful in figuring out what's gone wrong.

Additionally, users can now use integers for the 'sp' and 'pc'
attributes in their frame-id objects if that is useful.

Reviewed-By: Tom Tromey <tom@tromey.com>
2023-03-30 10:25:46 +01:00
Andrew Burgess
f4d9bc8356 gdb: have value_as_address call unpack_pointer
While refactoring some other code in gdb/python/* I wanted to merge
two code paths.  One path calls value_as_address, while the other
calls unpack_pointer.

I suspect calling value_as_address is the correct choice, but, while
examining the code I noticed that value_as_address calls unpack_long
rather than unpack_pointer.

Under the hood, unpack_pointer does just call unpack_long so there's
no real difference here, but it feels like value_as_address should
call unpack_pointer.

I've updated the code to use unpack_pointer, and changed a related
comment to say that we call unpack_pointer.  I've also adjusted the
header comment on value_as_address.  The existing header refers to
some code that is now commented out.

Rather than trying to describe the whole algorithm of
value_as_address, which is already well commented within the function,
I've just trimmed the comment on value_as_address to be a brief
summary of what the function does.

There should be no user visible changes after this commit.

Reviewed-By: Tom Tromey <tom@tromey.com>
2023-03-30 10:25:46 +01:00
Andrew Burgess
df4447e4c4 gdb/python: remove Py_TPFLAGS_BASETYPE from gdb.UnwindInfo
It is not currently possible to directly create gdb.UnwindInfo
instances, they need to be created by calling
gdb.PendingFrame.create_unwind_info so that the newly created
UnwindInfo can be linked to the pending frame.

As such there's no tp_init method defined for UnwindInfo.

A consequence of all this is that it doesn't really make sense to
allow sub-classing of gdb.UnwindInfo.  Any sub-class can't call the
parents __init__ method to correctly link up the PendingFrame
object (there is no parent __init__ method).  And any instances that
sub-classes UnwindInfo but doesn't call the parent __init__ is going
to be invalid for use in GDB.

This commit removes the Py_TPFLAGS_BASETYPE flag from the UnwindInfo
class, which prevents the class being sub-classed.  Then I've added a
test to check that this is indeed prevented.

Any functional user code will not have any issues with this change.

Reviewed-By: Tom Tromey <tom@tromey.com>
2023-03-30 10:25:46 +01:00
Andrew Burgess
7e6af18d0c gdb/python: add __repr__ for PendingFrame and UnwindInfo
Having a useful __repr__ method can make debugging Python code that
little bit easier.  This commit adds __repr__ for gdb.PendingFrame and
gdb.UnwindInfo classes, along with some tests.

Reviewed-By: Tom Tromey <tom@tromey.com>
2023-03-30 10:25:46 +01:00
Andrew Burgess
86b35b7116 gdb/python: add some additional methods to gdb.PendingFrame
The gdb.Frame class has far more methods than gdb.PendingFrame.  Given
that a PendingFrame hasn't yet been claimed by an unwinder, there is a
limit to which methods we can add to it, but many of the methods that
the Frame class has, the PendingFrame class could also support.

In this commit I've added those methods to PendingFrame that I believe
are safe.

In terms of implementation: if I was starting from scratch then I
would implement many of these (or most of these) as attributes rather
than methods.  However, given both Frame and PendingFrame are just
different representation of a frame, I think there is value in keeping
the interface for the two classes the same.  For this reason
everything here is a method -- that's what the Frame class does.

The new methods I've added are:

  - gdb.PendingFrame.is_valid: Return True if the pending frame
    object is valid.

  - gdb.PendingFrame.name: Return the name for the frame's function,
    or None.

  - gdb.PendingFrame.pc: Return the $pc register value for this
    frame.

  - gdb.PendingFrame.language: Return a string containing the
    language for this frame, or None.

  - gdb.PendingFrame.find_sal: Return a gdb.Symtab_and_line object
    for the current location within the pending frame, or None.

  - gdb.PendingFrame.block: Return a gdb.Block for the current
    pending frame, or None.

  - gdb.PendingFrame.function: Return a gdb.Symbol for the current
    pending frame, or None.

In every case I've just copied the implementation over from gdb.Frame
and cleaned the code slightly e.g. NULL to nullptr.  Additionally each
function required a small update to reflect the PendingFrame type, but
that's pretty minor.

There are tests for all the new methods.

For more extensive testing, I added the following code to the file
gdb/python/lib/command/unwinders.py:

  from gdb.unwinder import Unwinder

  class TestUnwinder(Unwinder):
      def __init__(self):
          super().__init__("XXX_TestUnwinder_XXX")

      def __call__(self,pending_frame):
          lang = pending_frame.language()
          try:
              block = pending_frame.block()
              assert isinstance(block, gdb.Block)
          except RuntimeError as rte:
              assert str(rte) == "Cannot locate block for frame."
          function = pending_frame.function()
          arch = pending_frame.architecture()
          assert arch is None or isinstance(arch, gdb.Architecture)
          name = pending_frame.name()
          assert name is None or isinstance(name, str)
          valid = pending_frame.is_valid()
          pc = pending_frame.pc()
          sal = pending_frame.find_sal()
          assert sal is None or isinstance(sal, gdb.Symtab_and_line)
          return None

  gdb.unwinder.register_unwinder(None, TestUnwinder())

This registers a global unwinder that calls each of the new
PendingFrame methods and checks the result is of an acceptable type.
The unwinder never claims any frames though, so shouldn't change how
GDB actually behaves.

I then ran the testsuite.  There was only a single regression, a test
that uses 'disable unwinder' and expects a single unwinder to be
disabled -- the extra unwinder is now disabled too, which changes the
test output.  So I'm reasonably confident that the new methods are not
going to crash GDB.

Reviewed-By: Eli Zaretskii <eliz@gnu.org>
Reviewed-By: Tom Tromey <tom@tromey.com>
2023-03-30 10:25:46 +01:00
Andrew Burgess
44d9b0a174 gdb/python: add PENDING_FRAMEPY_REQUIRE_VALID macro in py-unwind.c
This commit copies the pattern that is present in many other py-*.c
files: having a single macro to check that the Python object is still
valid.

This cleans up the code a little throughout the py-unwind.c file.

Some of the exception messages will change slightly with this commit,
though the type of the exceptions is still ValueError in all cases.

I started writing some tests for this change and immediately ran into
a problem: GDB would crash.  It turns out that the PendingFrame
objects are not being marked as invalid!

In pyuw_sniffer where the pending frames are created, we make use of a
scoped_restore to invalidate the pending frame objects.  However, this
only restores the pending_frame_object::frame_info field to its
previous value -- and it turns out we never actually give this field
an initial value, it's left undefined.

So, when the scoped_restore (called invalidate_frame) performs its
cleanup, it actually restores the frame_info field to an undefined
value.  If this undefined value is not nullptr then any future
accesses to the PendingFrame object result in undefined behaviour and
most likely, a crash.

As part of this commit I now initialize the frame_info field, which
ensures all the new tests now pass.

Reviewed-By: Tom Tromey <tom@tromey.com>
2023-03-30 10:25:46 +01:00
Andrew Burgess
3194ca90fe gdb/python: remove unneeded nullptr check in frapy_block
Spotted a redundant nullptr check in python/py-frame.c in the function
frapy_block.  This was introduced in commit 57126e4a45 when we
expanded an earlier check in return early if the pointer in question
is nullptr.

There should be no user visible changes after this commit.

Reviewed-By: Tom Tromey <tom@tromey.com>
2023-03-30 10:25:46 +01:00
Andrew Burgess
6bf5f25bb1 gdb/python: make the gdb.unwinder.Unwinder class more robust
This commit makes a few related changes to the gdb.unwinder.Unwinder
class attributes:

  1. The 'name' attribute is now a read-only attribute.  This prevents
  user code from changing the name after registering the unwinder.  It
  seems very unlikely that any user is actually trying to do this in
  the wild, so I'm not very worried that this will upset anyone,

  2. We now validate that the name is a string in the
  Unwinder.__init__ method, and throw an error if this is not the
  case.  Hopefully nobody was doing this in the wild.  This should
  make it easier to ensure the 'info unwinder' command shows sane
  output (how to display a non-string name for an unwinder?),

  3. The 'enabled' attribute is now implemented with a getter and
  setter.  In the setter we ensure that the new value is a boolean,
  but the real important change is that we call
  'gdb.invalidate_cached_frames()'.  This means that the backtrace
  will be updated if a user manually disables an unwinder (rather than
  calling the 'disable unwinder' command).  It is not unreasonable to
  think that a user might register multiple unwinders (relating to
  some project) and have one command that disables/enables all the
  related unwinders.  This command might operate by poking the enabled
  attribute of each unwinder object directly, after this commit, this
  would now work correctly.

There's tests for all the changes, and lots of documentation updates
that both cover the new changes, but also further improve (I think)
the general documentation for GDB's Unwinder API.

Reviewed-By: Eli Zaretskii <eliz@gnu.org>
Reviewed-By: Tom Tromey <tom@tromey.com>
2023-03-30 10:25:46 +01:00
Nick Clifton
c22d38baef Fix an illegal memory access when an accessing a zer0-lengthverdef table.
PR 30285
  * elf.c (_bfd_elf_slurp_version_tables): Fail if no version definitions are allocated.
2023-03-30 10:10:09 +01:00
Vladimir Mezentsev
f2f9bde5cd gprofng: Add version symbols to libgprofng.ver
gprofng/ChangeLog
2023-03-29  Vladimir Mezentsev  <vladimir.mezentsev@oracle.com>

	PR gprofng/30089
	* libcollector/libgprofng.ver: Add version symbols.
	* libcollector/synctrace.c: Fix typo for pthread_mutex_lock.
2023-03-29 23:09:40 -07:00
Alan Modra
6b958fe36b Setting sh_link for SHT_REL/SHT_RELA
It's wrong to have an alloc reloc section trying to use a non-alloc
symbol table.

	* elf.c (assign_section_numbers <SHT_REL, SHT_RELA>): Correct
	comment.  Always set sh_link to .dynsym for alloc reloc
	sections and to .symtab for non-alloc.
2023-03-30 15:18:02 +10:30
Alan Modra
ea7672c10e Fix memory leak in bfd_get_debug_link_info_1
* opncls.c (bfd_get_alt_debug_link_info): Don't bother freeing
	after bfd_malloc_and_get_section failure.
	(get_build_id): Likewise.
	(bfd_get_debug_link_info_1): Likewise.  Free section contents
	when crc not present.
	* section.c (bfd_malloc_and_get_section): Document that the
	buffer is NULL on error return.
2023-03-30 15:18:02 +10:30
Alan Modra
45fec14c02 Tidy leaked objcopy memory
* objcopy.c (delete_symbol_htabs): Also free symbols.
	(write_debugging_info): Free strings and syms once written.
	* wrstabs.c (write_stabs_in_sections_debugging_info): memset
	entire info struct.  Free hash tables before returning.  Free
	syms on error return.
2023-03-30 15:18:02 +10:30
Alan Modra
a2276a6d67 Tidy memory on addr2line failures
* addr2line.c (process_file): Close bfd on error paths.
2023-03-30 15:18:02 +10:30