mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-11-16 08:44:21 +08:00
229b159c50
Extend aquacomputer_d5next driver to expose hardware temperature sensors of the Aquacomputer Farbwerk RGB controller, which communicates through a proprietary USB HID protocol. Four temperature sensors are available. Additionally, serial number and firmware version are exposed through debugfs. Also, add Jack Doan to MAINTAINERS for this driver. Signed-off-by: Jack Doan <me@jackdoan.com> Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/YmTcrq8Gzel0zYYD@jackdesk Signed-off-by: Guenter Roeck <linux@roeck-us.net>
64 lines
2.3 KiB
ReStructuredText
64 lines
2.3 KiB
ReStructuredText
.. SPDX-License-Identifier: GPL-2.0-or-later
|
|
|
|
Kernel driver aquacomputer-d5next
|
|
=================================
|
|
|
|
Supported devices:
|
|
|
|
* Aquacomputer D5 Next watercooling pump
|
|
* Aquacomputer Farbwerk RGB controller
|
|
* Aquacomputer Farbwerk 360 RGB controller
|
|
* Aquacomputer Octo fan controller
|
|
|
|
Author: Aleksa Savic
|
|
|
|
Description
|
|
-----------
|
|
|
|
This driver exposes hardware sensors of listed Aquacomputer devices, which
|
|
communicate through proprietary USB HID protocols.
|
|
|
|
For the D5 Next pump, available sensors are pump and fan speed, power, voltage
|
|
and current, as well as coolant temperature. Also available through debugfs are
|
|
the serial number, firmware version and power-on count. Attaching a fan to it is
|
|
optional and allows it to be controlled using temperature curves directly from the
|
|
pump. If it's not connected, the fan-related sensors will report zeroes.
|
|
|
|
The pump can be configured either through software or via its physical
|
|
interface. Configuring the pump through this driver is not implemented, as it
|
|
seems to require sending it a complete configuration. That includes addressable
|
|
RGB LEDs, for which there is no standard sysfs interface. Thus, that task is
|
|
better suited for userspace tools.
|
|
|
|
The Octo exposes four temperature sensors and eight PWM controllable fans, along
|
|
with their speed (in RPM), power, voltage and current.
|
|
|
|
The Farbwerk and Farbwerk 360 expose four temperature sensors. Depending on the device,
|
|
not all sysfs and debugfs entries will be available.
|
|
|
|
Usage notes
|
|
-----------
|
|
|
|
The devices communicate via HID reports. The driver is loaded automatically by
|
|
the kernel and supports hotswapping.
|
|
|
|
Sysfs entries
|
|
-------------
|
|
|
|
================ =============================================
|
|
temp[1-4]_input Temperature sensors (in millidegrees Celsius)
|
|
fan[1-2]_input Pump/fan speed (in RPM)
|
|
power[1-2]_input Pump/fan power (in micro Watts)
|
|
in[0-2]_input Pump/fan voltage (in milli Volts)
|
|
curr[1-2]_input Pump/fan current (in milli Amperes)
|
|
================ =============================================
|
|
|
|
Debugfs entries
|
|
---------------
|
|
|
|
================ =================================================
|
|
serial_number Serial number of the device
|
|
firmware_version Version of installed firmware
|
|
power_cycles Count of how many times the device was powered on
|
|
================ =================================================
|