Now that the schema tools can extract type information for all properties (in order to decode dtb files), finding properties missing any type definition is fairly trivial though not yet automated. Fix the various property schemas which are missing a type. Most of these tend to be device specific properties which don't have a vendor prefix. A vendor prefix is how we normally ensure a type is defined. Signed-off-by: Rob Herring <robh@kernel.org> Acked-by: Sam Ravnborg <sam@ravnborg.org> # for everything in .../bindings/display/ Acked-by: Mark Brown <broonie@kernel.org> Acked-by: Peter Rosin <peda@axentia.se> Acked-by: Bartosz Golaszewski <brgl@bgdev.pl> Acked-by: Sebastian Reichel <sebastian.reichel@collabora.com> Link: https://lore.kernel.org/r/20220519211411.2200720-1-robh@kernel.org
185 lines
6.4 KiB
YAML
185 lines
6.4 KiB
YAML
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
|
|
%YAML 1.2
|
|
---
|
|
$id: http://devicetree.org/schemas/power/supply/battery.yaml#
|
|
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
|
|
|
title: Battery Characteristics
|
|
|
|
maintainers:
|
|
- Sebastian Reichel <sre@kernel.org>
|
|
|
|
description: |
|
|
The devicetree battery node provides static battery characteristics.
|
|
In smart batteries, these are typically stored in non-volatile memory
|
|
on a fuel gauge chip. The battery node should be used where there is
|
|
no appropriate non-volatile memory, or it is unprogrammed/incorrect.
|
|
|
|
Upstream dts files should not include battery nodes, unless the battery
|
|
represented cannot easily be replaced in the system by one of a
|
|
different type. This prevents unpredictable, potentially harmful,
|
|
behavior should a replacement that changes the battery type occur
|
|
without a corresponding update to the dtb.
|
|
|
|
Battery properties are named, where possible, for the corresponding elements
|
|
in enum power_supply_property, defined in include/linux/power_supply.h
|
|
|
|
Batteries must be referenced by chargers and/or fuel-gauges using a phandle.
|
|
The phandle's property should be named "monitored-battery".
|
|
|
|
properties:
|
|
compatible:
|
|
const: simple-battery
|
|
|
|
device-chemistry:
|
|
description: This describes the chemical technology of the battery.
|
|
oneOf:
|
|
- const: nickel-cadmium
|
|
- const: nickel-metal-hydride
|
|
- const: lithium-ion
|
|
description: This is a blanket type for all lithium-ion batteries,
|
|
including those below. If possible, a precise compatible string
|
|
from below should be used, but sometimes it is unknown which specific
|
|
lithium ion battery is employed and this wide compatible can be used.
|
|
- const: lithium-ion-polymer
|
|
- const: lithium-ion-iron-phosphate
|
|
- const: lithium-ion-manganese-oxide
|
|
|
|
over-voltage-threshold-microvolt:
|
|
description: battery over-voltage limit
|
|
|
|
re-charge-voltage-microvolt:
|
|
description: limit to automatically start charging again
|
|
|
|
voltage-min-design-microvolt:
|
|
description: drained battery voltage
|
|
|
|
voltage-max-design-microvolt:
|
|
description: fully charged battery voltage
|
|
|
|
energy-full-design-microwatt-hours:
|
|
description: battery design energy
|
|
|
|
charge-full-design-microamp-hours:
|
|
description: battery design capacity
|
|
|
|
trickle-charge-current-microamp:
|
|
description: current for trickle-charge phase
|
|
|
|
precharge-current-microamp:
|
|
description: current for pre-charge phase
|
|
|
|
precharge-upper-limit-microvolt:
|
|
description: limit when to change to constant charging
|
|
|
|
charge-term-current-microamp:
|
|
description: current for charge termination phase
|
|
|
|
constant-charge-current-max-microamp:
|
|
description: maximum constant input current
|
|
|
|
constant-charge-voltage-max-microvolt:
|
|
description: maximum constant input voltage
|
|
|
|
factory-internal-resistance-micro-ohms:
|
|
description: battery factory internal resistance
|
|
|
|
resistance-temp-table:
|
|
$ref: /schemas/types.yaml#/definitions/uint32-matrix
|
|
items:
|
|
items:
|
|
- description: the temperature in degree Celsius
|
|
- description: battery internal resistance percent
|
|
description: |
|
|
A table providing the temperature in degree Celsius
|
|
and corresponding battery internal resistance percent, which is used to
|
|
look up the resistance percent according to current temperature to get an
|
|
accurate batterty internal resistance in different temperatures.
|
|
|
|
ocv-capacity-celsius:
|
|
description: |
|
|
An array containing the temperature in degree Celsius,
|
|
for each of the battery capacity lookup table.
|
|
|
|
operating-range-celsius:
|
|
description: operating temperature range of a battery
|
|
items:
|
|
- description: minimum temperature at which battery can operate
|
|
- description: maximum temperature at which battery can operate
|
|
|
|
ambient-celsius:
|
|
description: safe range of ambient temperature
|
|
items:
|
|
- description: alert when ambient temperature is lower than this value
|
|
- description: alert when ambient temperature is higher than this value
|
|
|
|
alert-celsius:
|
|
description: safe range of battery temperature
|
|
items:
|
|
- description: alert when battery temperature is lower than this value
|
|
- description: alert when battery temperature is higher than this value
|
|
|
|
required:
|
|
- compatible
|
|
|
|
patternProperties:
|
|
'^ocv-capacity-table-[0-9]+$':
|
|
$ref: /schemas/types.yaml#/definitions/uint32-matrix
|
|
description: |
|
|
An array providing the open circuit voltage (OCV)
|
|
of the battery and corresponding battery capacity percent, which is used
|
|
to look up battery capacity according to current OCV value. And the open
|
|
circuit voltage unit is microvolt.
|
|
maxItems: 100
|
|
items:
|
|
items:
|
|
- description: open circuit voltage (OCV) in microvolts
|
|
- description: battery capacity percent
|
|
maximum: 100
|
|
|
|
additionalProperties: false
|
|
|
|
examples:
|
|
- |
|
|
power {
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
|
|
battery: battery {
|
|
compatible = "simple-battery";
|
|
over-voltage-threshold-microvolt = <4500000>;
|
|
re-charge-voltage-microvolt = <250000>;
|
|
voltage-min-design-microvolt = <3200000>;
|
|
voltage-max-design-microvolt = <4200000>;
|
|
energy-full-design-microwatt-hours = <5290000>;
|
|
charge-full-design-microamp-hours = <1430000>;
|
|
precharge-current-microamp = <256000>;
|
|
precharge-upper-limit-microvolt = <2500000>;
|
|
charge-term-current-microamp = <128000>;
|
|
constant-charge-current-max-microamp = <900000>;
|
|
constant-charge-voltage-max-microvolt = <4200000>;
|
|
factory-internal-resistance-micro-ohms = <250000>;
|
|
ocv-capacity-celsius = <(-10) 0 10>;
|
|
/* table for -10 degree Celsius */
|
|
ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>;
|
|
/* table for 0 degree Celsius */
|
|
ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>;
|
|
/* table for 10 degree Celsius */
|
|
ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>;
|
|
resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
|
|
operating-range-celsius = <(-30) 50>;
|
|
ambient-celsius = <(-5) 50>;
|
|
alert-celsius = <0 40>;
|
|
};
|
|
|
|
charger@11 {
|
|
reg = <0x11>;
|
|
monitored-battery = <&battery>;
|
|
};
|
|
|
|
fuel-gauge@22 {
|
|
reg = <0x22>;
|
|
monitored-battery = <&battery>;
|
|
};
|
|
};
|