mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-12-19 00:54:41 +08:00
e1e455f4f4
This patch fixes this build error with glibc < 2.6. CC util/cloexec.o cc1: warnings being treated as errors util/cloexec.c: In function ‘perf_flag_probe’: util/cloexec.c:24: error: implicit declaration of function ‘sched_getcpu’ util/cloexec.c:24: error: nested extern declaration of ‘sched_getcpu’ make: *** [util/cloexec.o] Error 1 Signed-off-by: Vinson Lee <vlee@twitter.com> Acked-by: Jiri Olsa <jolsa@kernel.org> Acked-by: Namhyung Kim <namhyung@kernel.org> Cc: Adrian Hunter <adrian.hunter@intel.com> Cc: Masami Hiramatsu <masami.hiramatsu.pt@hitachi.com> Cc: Paul Mackerras <paulus@samba.org> Cc: Peter Zijlstra <a.p.zijlstra@chello.nl> Cc: Yann Droneaud <ydroneaud@opteya.com> Cc: stable@vger.kernel.org # 3.18+ Link: http://lkml.kernel.org/r/1427137761-16119-1-git-send-email-vlee@twopensource.com Signed-off-by: Arnaldo Carvalho de Melo <acme@redhat.com>
93 lines
1.7 KiB
C
93 lines
1.7 KiB
C
#include <sched.h>
|
|
#include "util.h"
|
|
#include "../perf.h"
|
|
#include "cloexec.h"
|
|
#include "asm/bug.h"
|
|
#include "debug.h"
|
|
|
|
static unsigned long flag = PERF_FLAG_FD_CLOEXEC;
|
|
|
|
int __weak sched_getcpu(void)
|
|
{
|
|
errno = ENOSYS;
|
|
return -1;
|
|
}
|
|
|
|
static int perf_flag_probe(void)
|
|
{
|
|
/* use 'safest' configuration as used in perf_evsel__fallback() */
|
|
struct perf_event_attr attr = {
|
|
.type = PERF_TYPE_SOFTWARE,
|
|
.config = PERF_COUNT_SW_CPU_CLOCK,
|
|
.exclude_kernel = 1,
|
|
};
|
|
int fd;
|
|
int err;
|
|
int cpu;
|
|
pid_t pid = -1;
|
|
char sbuf[STRERR_BUFSIZE];
|
|
|
|
cpu = sched_getcpu();
|
|
if (cpu < 0)
|
|
cpu = 0;
|
|
|
|
/*
|
|
* Using -1 for the pid is a workaround to avoid gratuitous jump label
|
|
* changes.
|
|
*/
|
|
while (1) {
|
|
/* check cloexec flag */
|
|
fd = sys_perf_event_open(&attr, pid, cpu, -1,
|
|
PERF_FLAG_FD_CLOEXEC);
|
|
if (fd < 0 && pid == -1 && errno == EACCES) {
|
|
pid = 0;
|
|
continue;
|
|
}
|
|
break;
|
|
}
|
|
err = errno;
|
|
|
|
if (fd >= 0) {
|
|
close(fd);
|
|
return 1;
|
|
}
|
|
|
|
WARN_ONCE(err != EINVAL && err != EBUSY,
|
|
"perf_event_open(..., PERF_FLAG_FD_CLOEXEC) failed with unexpected error %d (%s)\n",
|
|
err, strerror_r(err, sbuf, sizeof(sbuf)));
|
|
|
|
/* not supported, confirm error related to PERF_FLAG_FD_CLOEXEC */
|
|
while (1) {
|
|
fd = sys_perf_event_open(&attr, pid, cpu, -1, 0);
|
|
if (fd < 0 && pid == -1 && errno == EACCES) {
|
|
pid = 0;
|
|
continue;
|
|
}
|
|
break;
|
|
}
|
|
err = errno;
|
|
|
|
if (fd >= 0)
|
|
close(fd);
|
|
|
|
if (WARN_ONCE(fd < 0 && err != EBUSY,
|
|
"perf_event_open(..., 0) failed unexpectedly with error %d (%s)\n",
|
|
err, strerror_r(err, sbuf, sizeof(sbuf))))
|
|
return -1;
|
|
|
|
return 0;
|
|
}
|
|
|
|
unsigned long perf_event_open_cloexec_flag(void)
|
|
{
|
|
static bool probed;
|
|
|
|
if (!probed) {
|
|
if (perf_flag_probe() <= 0)
|
|
flag = 0;
|
|
probed = true;
|
|
}
|
|
|
|
return flag;
|
|
}
|