mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-12-05 10:04:12 +08:00
d81f734462
A MegaRAID PCI card in my rp5470 acts as PCI-PCI bridge. Resource allocation for PCI devices behind such a bridge is quite incomplete, so that syslog reports those warnings: LBA 0:10: PCI host bridge to bus 0000:50 pci_bus 0000:50: root bus resource [io 0x80000-0x8ffff] (bus address [0x0000-0xffff]) pci_bus 0000:50: root bus resource [mem 0xffffffff94000000-0xffffffff95ffffff] (bus address [0x94000000-0x95ffffff]) pci_bus 0000:50: root bus resource [bus 50-57] pci 0000:50:00.0: [8086:0964] type 01 class 0x060400 pci 0000:50:00.1: [8086:1960] type 00 class 0x0e0001 pci 0000:50:00.1: reg 0x10: [mem 0x00000000-0x003fffff pref] pci 0000:50:00.1: reg 0x30: [mem 0x00000000-0x00007fff pref] pci 0000:50:00.0: Changing bridge control from 0x00000000 to 0x00000023 pci_bus 0000:51: busn_res: can not insert [bus 51-ff] under [bus 50-57] (conflicts with (null) [bus 50-57]) pci 0000:50:00.0: PCI bridge to [bus 51-ff] pci 0000:50:00.0: bridge window [io 0x80000-0x80fff] pci 0000:50:00.0: bridge window [mem 0x00000000-0x000fffff] pci 0000:50:00.0: bridge window [mem 0x00000000-0x000fffff pref] pci 0000:50:00.0: can't claim BAR 14 [mem 0x00000000-0x000fffff]: no compatible bridge window pci 0000:50:00.0: can't claim BAR 15 [mem 0x00000000-0x000fffff pref]: no compatible bridge window pci 0000:50:00.0: can't claim BAR 16 [??? 0x00000000 flags 0x0]: no compatible bridge window pci_bus 0000:51: busn_res: [bus 51-ff] end is updated to 51 pci 0000:50:00.0: BAR 16: [??? 0x00000000 flags 0x20000000] has bogus alignment pci 0000:50:00.1: BAR 0: assigned [mem 0xffffffff94000000-0xffffffff943fffff pref] pci 0000:50:00.0: BAR 14: assigned [mem 0xffffffff94400000-0xffffffff944fffff] pci 0000:50:00.0: BAR 15: assigned [mem 0xffffffff94500000-0xffffffff945fffff pref] pci 0000:50:00.1: BAR 6: assigned [mem 0xffffffff94600000-0xffffffff94607fff pref] pci 0000:50:00.0: PCI bridge to [bus 51] pci 0000:50:00.0: bridge window [io 0x80000-0x80fff] pci 0000:50:00.0: bridge window [mem 0xffffffff94400000-0xffffffff944fffff] pci 0000:50:00.0: bridge window [mem 0xffffffff94500000-0xffffffff945fffff pref] The patch below tries to improve the resource allocation. Output is now: LBA 0:10: PCI host bridge to bus 0000:50 pci_bus 0000:50: root bus resource [io 0x80000-0x8ffff] (bus address [0x0000-0xffff]) pci_bus 0000:50: root bus resource [mem 0xffffffff94000000-0xffffffff95ffffff] (bus address [0x94000000-0x95ffffff]) pci_bus 0000:50: root bus resource [bus 50-57] pci 0000:50:00.0: Changing bridge control from 0x00000000 to 0x00000023 pci 0000:50:00.0: PCI bridge to [bus 51-ff] pci 0000:50:00.1: BAR 0: assigned [mem 0xffffffff94000000-0xffffffff943fffff pref] pci 0000:50:00.1: BAR 6: assigned [mem 0xffffffff94400000-0xffffffff94407fff pref] pci 0000:50:00.0: PCI bridge to [bus 51] pci 0000:50:00.0: bridge window [io 0x80000-0x80fff] Signed-off-by: Helge Deller <deller@gmx.de> |
||
---|---|---|
.. | ||
asp.c | ||
ccio-dma.c | ||
ccio-rm-dma.c | ||
dino.c | ||
eisa_eeprom.c | ||
eisa_enumerator.c | ||
eisa.c | ||
gsc.c | ||
gsc.h | ||
hppb.c | ||
iommu-helpers.h | ||
iosapic_private.h | ||
iosapic.c | ||
Kconfig | ||
lasi.c | ||
lba_pci.c | ||
led.c | ||
Makefile | ||
pdc_stable.c | ||
power.c | ||
README.dino | ||
sba_iommu.c | ||
superio.c | ||
wax.c |
/* ** HP VISUALIZE Workstation PCI Bus Defect ** ** "HP has discovered a potential system defect that can affect ** the behavior of five models of HP VISUALIZE workstations when ** equipped with third-party or customer-installed PCI I/O expansion ** cards. The defect is limited to the HP C180, C160, C160L, B160L, ** and B132L VISUALIZE workstations, and will only be encountered ** when data is transmitted through PCI I/O expansion cards on the ** PCI bus. HP-supplied graphics cards that utilize the PCI bus are ** not affected." ** ** http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp?locale=en_US&prodTypeId=12454&prodSeriesId=44443 ** ** Product First Good Serial Number ** C200/C240 (US) US67350000 **B132L+/B180 (US) US67390000 ** C200 (Europe) 3713G01000 ** B180L (Europe) 3720G01000 ** ** Note that many boards were fixed/replaced under a free replacement ** program. Assume a machine is only "suspect" until proven otherwise. ** ** "The pci_check program will also be available as application ** patch PHSS_12295" */