Recently, the sof_pcm_dai_link_fixup() function was
updated to match SSP config with the PCM hw_params
and set the current_config for the DAI widget.
But the sof_restore_pipelines() function still chooses the
default config for the DAI widget upon resuming. Fix this
to use the last used config when setting up the DAI widget
during resume.
Fixes: c943a586f6 ("ASoC: SOF: match SSP config with pcm hw params")
Reviewed-by: Kai Vehmanen <kai.vehmanen@linux.intel.com>
Signed-off-by: Ranjani Sridharan <ranjani.sridharan@linux.intel.com>
Signed-off-by: Pierre-Louis Bossart <pierre-louis.bossart@linux.intel.com>
Link: https://lore.kernel.org/r/20210415162107.130963-1-pierre-louis.bossart@linux.intel.com
Signed-off-by: Mark Brown <broonie@kernel.org>