mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-11-25 05:04:09 +08:00
2ad8ccc17d
The thermal pressure signal gives information to the scheduler about
reduced CPU capacity due to thermal. It is based on a value stored in
a per-cpu 'thermal_pressure' variable. The online CPUs will get the
new value there, while the offline won't. Unfortunately, when the CPU
is back online, the value read from per-cpu variable might be wrong
(stale data). This might affect the scheduler decisions, since it
sees the CPU capacity differently than what is actually available.
Fix it by making sure that all online+offline CPUs would get the
proper value in their per-cpu variable when thermal framework sets
capping.
Fixes: f12e4f66ab
("thermal/cpu-cooling: Update thermal pressure in case of a maximum frequency capping")
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Link: https://lore.kernel.org/r/20210614191030.22241-1-lukasz.luba@arm.com
697 lines
20 KiB
C
697 lines
20 KiB
C
// SPDX-License-Identifier: GPL-2.0
|
|
/*
|
|
* linux/drivers/thermal/cpufreq_cooling.c
|
|
*
|
|
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
|
*
|
|
* Copyright (C) 2012-2018 Linaro Limited.
|
|
*
|
|
* Authors: Amit Daniel <amit.kachhap@linaro.org>
|
|
* Viresh Kumar <viresh.kumar@linaro.org>
|
|
*
|
|
*/
|
|
#include <linux/cpu.h>
|
|
#include <linux/cpufreq.h>
|
|
#include <linux/cpu_cooling.h>
|
|
#include <linux/device.h>
|
|
#include <linux/energy_model.h>
|
|
#include <linux/err.h>
|
|
#include <linux/export.h>
|
|
#include <linux/pm_opp.h>
|
|
#include <linux/pm_qos.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/thermal.h>
|
|
|
|
#include <trace/events/thermal.h>
|
|
|
|
/*
|
|
* Cooling state <-> CPUFreq frequency
|
|
*
|
|
* Cooling states are translated to frequencies throughout this driver and this
|
|
* is the relation between them.
|
|
*
|
|
* Highest cooling state corresponds to lowest possible frequency.
|
|
*
|
|
* i.e.
|
|
* level 0 --> 1st Max Freq
|
|
* level 1 --> 2nd Max Freq
|
|
* ...
|
|
*/
|
|
|
|
/**
|
|
* struct time_in_idle - Idle time stats
|
|
* @time: previous reading of the absolute time that this cpu was idle
|
|
* @timestamp: wall time of the last invocation of get_cpu_idle_time_us()
|
|
*/
|
|
struct time_in_idle {
|
|
u64 time;
|
|
u64 timestamp;
|
|
};
|
|
|
|
/**
|
|
* struct cpufreq_cooling_device - data for cooling device with cpufreq
|
|
* @last_load: load measured by the latest call to cpufreq_get_requested_power()
|
|
* @cpufreq_state: integer value representing the current state of cpufreq
|
|
* cooling devices.
|
|
* @max_level: maximum cooling level. One less than total number of valid
|
|
* cpufreq frequencies.
|
|
* @em: Reference on the Energy Model of the device
|
|
* @cdev: thermal_cooling_device pointer to keep track of the
|
|
* registered cooling device.
|
|
* @policy: cpufreq policy.
|
|
* @idle_time: idle time stats
|
|
* @qos_req: PM QoS contraint to apply
|
|
*
|
|
* This structure is required for keeping information of each registered
|
|
* cpufreq_cooling_device.
|
|
*/
|
|
struct cpufreq_cooling_device {
|
|
u32 last_load;
|
|
unsigned int cpufreq_state;
|
|
unsigned int max_level;
|
|
struct em_perf_domain *em;
|
|
struct cpufreq_policy *policy;
|
|
#ifndef CONFIG_SMP
|
|
struct time_in_idle *idle_time;
|
|
#endif
|
|
struct freq_qos_request qos_req;
|
|
};
|
|
|
|
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
|
|
/**
|
|
* get_level: Find the level for a particular frequency
|
|
* @cpufreq_cdev: cpufreq_cdev for which the property is required
|
|
* @freq: Frequency
|
|
*
|
|
* Return: level corresponding to the frequency.
|
|
*/
|
|
static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
unsigned int freq)
|
|
{
|
|
int i;
|
|
|
|
for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) {
|
|
if (freq > cpufreq_cdev->em->table[i].frequency)
|
|
break;
|
|
}
|
|
|
|
return cpufreq_cdev->max_level - i - 1;
|
|
}
|
|
|
|
static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
u32 freq)
|
|
{
|
|
int i;
|
|
|
|
for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) {
|
|
if (freq > cpufreq_cdev->em->table[i].frequency)
|
|
break;
|
|
}
|
|
|
|
return cpufreq_cdev->em->table[i + 1].power;
|
|
}
|
|
|
|
static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
u32 power)
|
|
{
|
|
int i;
|
|
|
|
for (i = cpufreq_cdev->max_level; i > 0; i--) {
|
|
if (power >= cpufreq_cdev->em->table[i].power)
|
|
break;
|
|
}
|
|
|
|
return cpufreq_cdev->em->table[i].frequency;
|
|
}
|
|
|
|
/**
|
|
* get_load() - get load for a cpu
|
|
* @cpufreq_cdev: struct cpufreq_cooling_device for the cpu
|
|
* @cpu: cpu number
|
|
* @cpu_idx: index of the cpu in time_in_idle array
|
|
*
|
|
* Return: The average load of cpu @cpu in percentage since this
|
|
* function was last called.
|
|
*/
|
|
#ifdef CONFIG_SMP
|
|
static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
|
|
int cpu_idx)
|
|
{
|
|
unsigned long max = arch_scale_cpu_capacity(cpu);
|
|
unsigned long util;
|
|
|
|
util = sched_cpu_util(cpu, max);
|
|
return (util * 100) / max;
|
|
}
|
|
#else /* !CONFIG_SMP */
|
|
static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
|
|
int cpu_idx)
|
|
{
|
|
u32 load;
|
|
u64 now, now_idle, delta_time, delta_idle;
|
|
struct time_in_idle *idle_time = &cpufreq_cdev->idle_time[cpu_idx];
|
|
|
|
now_idle = get_cpu_idle_time(cpu, &now, 0);
|
|
delta_idle = now_idle - idle_time->time;
|
|
delta_time = now - idle_time->timestamp;
|
|
|
|
if (delta_time <= delta_idle)
|
|
load = 0;
|
|
else
|
|
load = div64_u64(100 * (delta_time - delta_idle), delta_time);
|
|
|
|
idle_time->time = now_idle;
|
|
idle_time->timestamp = now;
|
|
|
|
return load;
|
|
}
|
|
#endif /* CONFIG_SMP */
|
|
|
|
/**
|
|
* get_dynamic_power() - calculate the dynamic power
|
|
* @cpufreq_cdev: &cpufreq_cooling_device for this cdev
|
|
* @freq: current frequency
|
|
*
|
|
* Return: the dynamic power consumed by the cpus described by
|
|
* @cpufreq_cdev.
|
|
*/
|
|
static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
unsigned long freq)
|
|
{
|
|
u32 raw_cpu_power;
|
|
|
|
raw_cpu_power = cpu_freq_to_power(cpufreq_cdev, freq);
|
|
return (raw_cpu_power * cpufreq_cdev->last_load) / 100;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_get_requested_power() - get the current power
|
|
* @cdev: &thermal_cooling_device pointer
|
|
* @power: pointer in which to store the resulting power
|
|
*
|
|
* Calculate the current power consumption of the cpus in milliwatts
|
|
* and store it in @power. This function should actually calculate
|
|
* the requested power, but it's hard to get the frequency that
|
|
* cpufreq would have assigned if there were no thermal limits.
|
|
* Instead, we calculate the current power on the assumption that the
|
|
* immediate future will look like the immediate past.
|
|
*
|
|
* We use the current frequency and the average load since this
|
|
* function was last called. In reality, there could have been
|
|
* multiple opps since this function was last called and that affects
|
|
* the load calculation. While it's not perfectly accurate, this
|
|
* simplification is good enough and works. REVISIT this, as more
|
|
* complex code may be needed if experiments show that it's not
|
|
* accurate enough.
|
|
*
|
|
* Return: 0 on success, -E* if getting the static power failed.
|
|
*/
|
|
static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
|
|
u32 *power)
|
|
{
|
|
unsigned long freq;
|
|
int i = 0, cpu;
|
|
u32 total_load = 0;
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
struct cpufreq_policy *policy = cpufreq_cdev->policy;
|
|
u32 *load_cpu = NULL;
|
|
|
|
freq = cpufreq_quick_get(policy->cpu);
|
|
|
|
if (trace_thermal_power_cpu_get_power_enabled()) {
|
|
u32 ncpus = cpumask_weight(policy->related_cpus);
|
|
|
|
load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL);
|
|
}
|
|
|
|
for_each_cpu(cpu, policy->related_cpus) {
|
|
u32 load;
|
|
|
|
if (cpu_online(cpu))
|
|
load = get_load(cpufreq_cdev, cpu, i);
|
|
else
|
|
load = 0;
|
|
|
|
total_load += load;
|
|
if (load_cpu)
|
|
load_cpu[i] = load;
|
|
|
|
i++;
|
|
}
|
|
|
|
cpufreq_cdev->last_load = total_load;
|
|
|
|
*power = get_dynamic_power(cpufreq_cdev, freq);
|
|
|
|
if (load_cpu) {
|
|
trace_thermal_power_cpu_get_power(policy->related_cpus, freq,
|
|
load_cpu, i, *power);
|
|
|
|
kfree(load_cpu);
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_state2power() - convert a cpu cdev state to power consumed
|
|
* @cdev: &thermal_cooling_device pointer
|
|
* @state: cooling device state to be converted
|
|
* @power: pointer in which to store the resulting power
|
|
*
|
|
* Convert cooling device state @state into power consumption in
|
|
* milliwatts assuming 100% load. Store the calculated power in
|
|
* @power.
|
|
*
|
|
* Return: 0 on success, -EINVAL if the cooling device state could not
|
|
* be converted into a frequency or other -E* if there was an error
|
|
* when calculating the static power.
|
|
*/
|
|
static int cpufreq_state2power(struct thermal_cooling_device *cdev,
|
|
unsigned long state, u32 *power)
|
|
{
|
|
unsigned int freq, num_cpus, idx;
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
|
|
/* Request state should be less than max_level */
|
|
if (state > cpufreq_cdev->max_level)
|
|
return -EINVAL;
|
|
|
|
num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus);
|
|
|
|
idx = cpufreq_cdev->max_level - state;
|
|
freq = cpufreq_cdev->em->table[idx].frequency;
|
|
*power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_power2state() - convert power to a cooling device state
|
|
* @cdev: &thermal_cooling_device pointer
|
|
* @power: power in milliwatts to be converted
|
|
* @state: pointer in which to store the resulting state
|
|
*
|
|
* Calculate a cooling device state for the cpus described by @cdev
|
|
* that would allow them to consume at most @power mW and store it in
|
|
* @state. Note that this calculation depends on external factors
|
|
* such as the cpu load or the current static power. Calling this
|
|
* function with the same power as input can yield different cooling
|
|
* device states depending on those external factors.
|
|
*
|
|
* Return: 0 on success, -ENODEV if no cpus are online or -EINVAL if
|
|
* the calculated frequency could not be converted to a valid state.
|
|
* The latter should not happen unless the frequencies available to
|
|
* cpufreq have changed since the initialization of the cpu cooling
|
|
* device.
|
|
*/
|
|
static int cpufreq_power2state(struct thermal_cooling_device *cdev,
|
|
u32 power, unsigned long *state)
|
|
{
|
|
unsigned int target_freq;
|
|
u32 last_load, normalised_power;
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
struct cpufreq_policy *policy = cpufreq_cdev->policy;
|
|
|
|
last_load = cpufreq_cdev->last_load ?: 1;
|
|
normalised_power = (power * 100) / last_load;
|
|
target_freq = cpu_power_to_freq(cpufreq_cdev, normalised_power);
|
|
|
|
*state = get_level(cpufreq_cdev, target_freq);
|
|
trace_thermal_power_cpu_limit(policy->related_cpus, target_freq, *state,
|
|
power);
|
|
return 0;
|
|
}
|
|
|
|
static inline bool em_is_sane(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
struct em_perf_domain *em) {
|
|
struct cpufreq_policy *policy;
|
|
unsigned int nr_levels;
|
|
|
|
if (!em)
|
|
return false;
|
|
|
|
policy = cpufreq_cdev->policy;
|
|
if (!cpumask_equal(policy->related_cpus, em_span_cpus(em))) {
|
|
pr_err("The span of pd %*pbl is misaligned with cpufreq policy %*pbl\n",
|
|
cpumask_pr_args(em_span_cpus(em)),
|
|
cpumask_pr_args(policy->related_cpus));
|
|
return false;
|
|
}
|
|
|
|
nr_levels = cpufreq_cdev->max_level + 1;
|
|
if (em_pd_nr_perf_states(em) != nr_levels) {
|
|
pr_err("The number of performance states in pd %*pbl (%u) doesn't match the number of cooling levels (%u)\n",
|
|
cpumask_pr_args(em_span_cpus(em)),
|
|
em_pd_nr_perf_states(em), nr_levels);
|
|
return false;
|
|
}
|
|
|
|
return true;
|
|
}
|
|
#endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */
|
|
|
|
#ifdef CONFIG_SMP
|
|
static inline int allocate_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
|
|
{
|
|
return 0;
|
|
}
|
|
|
|
static inline void free_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
|
|
{
|
|
}
|
|
#else
|
|
static int allocate_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
|
|
{
|
|
unsigned int num_cpus = cpumask_weight(cpufreq_cdev->policy->related_cpus);
|
|
|
|
cpufreq_cdev->idle_time = kcalloc(num_cpus,
|
|
sizeof(*cpufreq_cdev->idle_time),
|
|
GFP_KERNEL);
|
|
if (!cpufreq_cdev->idle_time)
|
|
return -ENOMEM;
|
|
|
|
return 0;
|
|
}
|
|
|
|
static void free_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
|
|
{
|
|
kfree(cpufreq_cdev->idle_time);
|
|
cpufreq_cdev->idle_time = NULL;
|
|
}
|
|
#endif /* CONFIG_SMP */
|
|
|
|
static unsigned int get_state_freq(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
unsigned long state)
|
|
{
|
|
struct cpufreq_policy *policy;
|
|
unsigned long idx;
|
|
|
|
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
|
|
/* Use the Energy Model table if available */
|
|
if (cpufreq_cdev->em) {
|
|
idx = cpufreq_cdev->max_level - state;
|
|
return cpufreq_cdev->em->table[idx].frequency;
|
|
}
|
|
#endif
|
|
|
|
/* Otherwise, fallback on the CPUFreq table */
|
|
policy = cpufreq_cdev->policy;
|
|
if (policy->freq_table_sorted == CPUFREQ_TABLE_SORTED_ASCENDING)
|
|
idx = cpufreq_cdev->max_level - state;
|
|
else
|
|
idx = state;
|
|
|
|
return policy->freq_table[idx].frequency;
|
|
}
|
|
|
|
/* cpufreq cooling device callback functions are defined below */
|
|
|
|
/**
|
|
* cpufreq_get_max_state - callback function to get the max cooling state.
|
|
* @cdev: thermal cooling device pointer.
|
|
* @state: fill this variable with the max cooling state.
|
|
*
|
|
* Callback for the thermal cooling device to return the cpufreq
|
|
* max cooling state.
|
|
*
|
|
* Return: 0 on success, an error code otherwise.
|
|
*/
|
|
static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
|
|
unsigned long *state)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
|
|
*state = cpufreq_cdev->max_level;
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_get_cur_state - callback function to get the current cooling state.
|
|
* @cdev: thermal cooling device pointer.
|
|
* @state: fill this variable with the current cooling state.
|
|
*
|
|
* Callback for the thermal cooling device to return the cpufreq
|
|
* current cooling state.
|
|
*
|
|
* Return: 0 on success, an error code otherwise.
|
|
*/
|
|
static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
|
|
unsigned long *state)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
|
|
*state = cpufreq_cdev->cpufreq_state;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_set_cur_state - callback function to set the current cooling state.
|
|
* @cdev: thermal cooling device pointer.
|
|
* @state: set this variable to the current cooling state.
|
|
*
|
|
* Callback for the thermal cooling device to change the cpufreq
|
|
* current cooling state.
|
|
*
|
|
* Return: 0 on success, an error code otherwise.
|
|
*/
|
|
static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
|
|
unsigned long state)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
struct cpumask *cpus;
|
|
unsigned int frequency;
|
|
unsigned long max_capacity, capacity;
|
|
int ret;
|
|
|
|
/* Request state should be less than max_level */
|
|
if (state > cpufreq_cdev->max_level)
|
|
return -EINVAL;
|
|
|
|
/* Check if the old cooling action is same as new cooling action */
|
|
if (cpufreq_cdev->cpufreq_state == state)
|
|
return 0;
|
|
|
|
frequency = get_state_freq(cpufreq_cdev, state);
|
|
|
|
ret = freq_qos_update_request(&cpufreq_cdev->qos_req, frequency);
|
|
if (ret >= 0) {
|
|
cpufreq_cdev->cpufreq_state = state;
|
|
cpus = cpufreq_cdev->policy->related_cpus;
|
|
max_capacity = arch_scale_cpu_capacity(cpumask_first(cpus));
|
|
capacity = frequency * max_capacity;
|
|
capacity /= cpufreq_cdev->policy->cpuinfo.max_freq;
|
|
arch_set_thermal_pressure(cpus, max_capacity - capacity);
|
|
ret = 0;
|
|
}
|
|
|
|
return ret;
|
|
}
|
|
|
|
/* Bind cpufreq callbacks to thermal cooling device ops */
|
|
|
|
static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
|
|
.get_max_state = cpufreq_get_max_state,
|
|
.get_cur_state = cpufreq_get_cur_state,
|
|
.set_cur_state = cpufreq_set_cur_state,
|
|
};
|
|
|
|
/**
|
|
* __cpufreq_cooling_register - helper function to create cpufreq cooling device
|
|
* @np: a valid struct device_node to the cooling device device tree node
|
|
* @policy: cpufreq policy
|
|
* Normally this should be same as cpufreq policy->related_cpus.
|
|
* @em: Energy Model of the cpufreq policy
|
|
*
|
|
* This interface function registers the cpufreq cooling device with the name
|
|
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
|
|
* cooling devices. It also gives the opportunity to link the cooling device
|
|
* with a device tree node, in order to bind it via the thermal DT code.
|
|
*
|
|
* Return: a valid struct thermal_cooling_device pointer on success,
|
|
* on failure, it returns a corresponding ERR_PTR().
|
|
*/
|
|
static struct thermal_cooling_device *
|
|
__cpufreq_cooling_register(struct device_node *np,
|
|
struct cpufreq_policy *policy,
|
|
struct em_perf_domain *em)
|
|
{
|
|
struct thermal_cooling_device *cdev;
|
|
struct cpufreq_cooling_device *cpufreq_cdev;
|
|
unsigned int i;
|
|
struct device *dev;
|
|
int ret;
|
|
struct thermal_cooling_device_ops *cooling_ops;
|
|
char *name;
|
|
|
|
dev = get_cpu_device(policy->cpu);
|
|
if (unlikely(!dev)) {
|
|
pr_warn("No cpu device for cpu %d\n", policy->cpu);
|
|
return ERR_PTR(-ENODEV);
|
|
}
|
|
|
|
if (IS_ERR_OR_NULL(policy)) {
|
|
pr_err("%s: cpufreq policy isn't valid: %p\n", __func__, policy);
|
|
return ERR_PTR(-EINVAL);
|
|
}
|
|
|
|
i = cpufreq_table_count_valid_entries(policy);
|
|
if (!i) {
|
|
pr_debug("%s: CPUFreq table not found or has no valid entries\n",
|
|
__func__);
|
|
return ERR_PTR(-ENODEV);
|
|
}
|
|
|
|
cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL);
|
|
if (!cpufreq_cdev)
|
|
return ERR_PTR(-ENOMEM);
|
|
|
|
cpufreq_cdev->policy = policy;
|
|
|
|
ret = allocate_idle_time(cpufreq_cdev);
|
|
if (ret) {
|
|
cdev = ERR_PTR(ret);
|
|
goto free_cdev;
|
|
}
|
|
|
|
/* max_level is an index, not a counter */
|
|
cpufreq_cdev->max_level = i - 1;
|
|
|
|
cooling_ops = &cpufreq_cooling_ops;
|
|
|
|
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
|
|
if (em_is_sane(cpufreq_cdev, em)) {
|
|
cpufreq_cdev->em = em;
|
|
cooling_ops->get_requested_power = cpufreq_get_requested_power;
|
|
cooling_ops->state2power = cpufreq_state2power;
|
|
cooling_ops->power2state = cpufreq_power2state;
|
|
} else
|
|
#endif
|
|
if (policy->freq_table_sorted == CPUFREQ_TABLE_UNSORTED) {
|
|
pr_err("%s: unsorted frequency tables are not supported\n",
|
|
__func__);
|
|
cdev = ERR_PTR(-EINVAL);
|
|
goto free_idle_time;
|
|
}
|
|
|
|
ret = freq_qos_add_request(&policy->constraints,
|
|
&cpufreq_cdev->qos_req, FREQ_QOS_MAX,
|
|
get_state_freq(cpufreq_cdev, 0));
|
|
if (ret < 0) {
|
|
pr_err("%s: Failed to add freq constraint (%d)\n", __func__,
|
|
ret);
|
|
cdev = ERR_PTR(ret);
|
|
goto free_idle_time;
|
|
}
|
|
|
|
cdev = ERR_PTR(-ENOMEM);
|
|
name = kasprintf(GFP_KERNEL, "cpufreq-%s", dev_name(dev));
|
|
if (!name)
|
|
goto remove_qos_req;
|
|
|
|
cdev = thermal_of_cooling_device_register(np, name, cpufreq_cdev,
|
|
cooling_ops);
|
|
kfree(name);
|
|
|
|
if (IS_ERR(cdev))
|
|
goto remove_qos_req;
|
|
|
|
return cdev;
|
|
|
|
remove_qos_req:
|
|
freq_qos_remove_request(&cpufreq_cdev->qos_req);
|
|
free_idle_time:
|
|
free_idle_time(cpufreq_cdev);
|
|
free_cdev:
|
|
kfree(cpufreq_cdev);
|
|
return cdev;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_cooling_register - function to create cpufreq cooling device.
|
|
* @policy: cpufreq policy
|
|
*
|
|
* This interface function registers the cpufreq cooling device with the name
|
|
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
|
|
* cooling devices.
|
|
*
|
|
* Return: a valid struct thermal_cooling_device pointer on success,
|
|
* on failure, it returns a corresponding ERR_PTR().
|
|
*/
|
|
struct thermal_cooling_device *
|
|
cpufreq_cooling_register(struct cpufreq_policy *policy)
|
|
{
|
|
return __cpufreq_cooling_register(NULL, policy, NULL);
|
|
}
|
|
EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
|
|
|
|
/**
|
|
* of_cpufreq_cooling_register - function to create cpufreq cooling device.
|
|
* @policy: cpufreq policy
|
|
*
|
|
* This interface function registers the cpufreq cooling device with the name
|
|
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
|
|
* cooling devices. Using this API, the cpufreq cooling device will be
|
|
* linked to the device tree node provided.
|
|
*
|
|
* Using this function, the cooling device will implement the power
|
|
* extensions by using a simple cpu power model. The cpus must have
|
|
* registered their OPPs using the OPP library.
|
|
*
|
|
* It also takes into account, if property present in policy CPU node, the
|
|
* static power consumed by the cpu.
|
|
*
|
|
* Return: a valid struct thermal_cooling_device pointer on success,
|
|
* and NULL on failure.
|
|
*/
|
|
struct thermal_cooling_device *
|
|
of_cpufreq_cooling_register(struct cpufreq_policy *policy)
|
|
{
|
|
struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
|
|
struct thermal_cooling_device *cdev = NULL;
|
|
|
|
if (!np) {
|
|
pr_err("cpufreq_cooling: OF node not available for cpu%d\n",
|
|
policy->cpu);
|
|
return NULL;
|
|
}
|
|
|
|
if (of_find_property(np, "#cooling-cells", NULL)) {
|
|
struct em_perf_domain *em = em_cpu_get(policy->cpu);
|
|
|
|
cdev = __cpufreq_cooling_register(np, policy, em);
|
|
if (IS_ERR(cdev)) {
|
|
pr_err("cpufreq_cooling: cpu%d failed to register as cooling device: %ld\n",
|
|
policy->cpu, PTR_ERR(cdev));
|
|
cdev = NULL;
|
|
}
|
|
}
|
|
|
|
of_node_put(np);
|
|
return cdev;
|
|
}
|
|
EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
|
|
|
|
/**
|
|
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
|
|
* @cdev: thermal cooling device pointer.
|
|
*
|
|
* This interface function unregisters the "thermal-cpufreq-%x" cooling device.
|
|
*/
|
|
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_cdev;
|
|
|
|
if (!cdev)
|
|
return;
|
|
|
|
cpufreq_cdev = cdev->devdata;
|
|
|
|
thermal_cooling_device_unregister(cdev);
|
|
freq_qos_remove_request(&cpufreq_cdev->qos_req);
|
|
free_idle_time(cpufreq_cdev);
|
|
kfree(cpufreq_cdev);
|
|
}
|
|
EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);
|