The low-level interrupt handler on s390 checks for _TIF_WORK_INT and
exits the guest context, if work is pending.
TIF_WORK_INT is defined as_TIF_SIGPENDING | _TIF_NEED_RESCHED |
_TIF_MCCK_PENDING. Currently the sie loop checks for signals and
reschedule, but it does not check for machine checks. That means that
we exit the guest context if a machine check is pending, but we do not
handle the machine check.
Signed-off-by: Christian Borntraeger <borntraeger@de.ibm.com>
CC: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Carsten Otte <cotte@de.ibm.com>
Signed-off-by: Avi Kivity <avi@qumranet.com>