The FSI protocol defines two modes of recovery from CRC errors, this implements both: - If the device returns an ECRC (it detected a CRC error in the command), then we simply issue the command again. - If the master detects a CRC error in the response, we send an E_POLL command which requests a resend of the response without actually re-executing the command (which could otherwise have unwanted side effects such as dequeuing a FIFO twice). Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org> Reviewed-by: Christopher Bostic <cbostic@linux.vnet.ibm.com> Tested-by: Joel Stanley <joel@jms.id.au> --- Note: This was actually tested by removing some of my fixes, thus causing us to hit occasional CRC errors during high LPC activity. |
||
---|---|---|
.. | ||