Currently, when we add the first sja1105 port to a bridge with
vlan_filtering 1, then we sometimes see this output:
sja1105 spi2.2: port 4 failed to read back entry for be:79:b4:9e:9e:96 vid 3088: -ENOENT
sja1105 spi2.2: Reset switch and programmed static config. Reason: VLAN filtering
sja1105 spi2.2: port 0 failed to add be:79:b4:9e:9e:96 vid 0 to fdb: -2
It is because sja1105_fdb_add() runs from the dsa_owq which is no longer
serialized with switch resets since it dropped the rtnl_lock() in the
blamed commit.
Either performing the FDB accesses before the reset, or after the reset,
is equally fine, because sja1105_static_fdb_change() backs up those
changes in the static config, but FDB access during reset isn't ok.
Make sja1105_static_config_reload() take the fdb_lock to fix that.
Fixes: 0faf890fc5 ("net: dsa: drop rtnl_lock from dsa_slave_switchdev_event_work")
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>