linux/kernel/time/tick-oneshot.c
Christoph Lameter 909ea96468 core: Replace __get_cpu_var with __this_cpu_read if not used for an address.
__get_cpu_var() can be replaced with this_cpu_read and will then use a
single read instruction with implied address calculation to access the
correct per cpu instance.

However, the address of a per cpu variable passed to __this_cpu_read()
cannot be determined (since it's an implied address conversion through
segment prefixes).  Therefore apply this only to uses of __get_cpu_var
where the address of the variable is not used.

Cc: Pekka Enberg <penberg@cs.helsinki.fi>
Cc: Hugh Dickins <hughd@google.com>
Cc: Thomas Gleixner <tglx@linutronix.de>
Acked-by: H. Peter Anvin <hpa@zytor.com>
Signed-off-by: Christoph Lameter <cl@linux.com>
Signed-off-by: Tejun Heo <tj@kernel.org>
2010-12-17 15:07:19 +01:00

187 lines
4.5 KiB
C

/*
* linux/kernel/time/tick-oneshot.c
*
* This file contains functions which manage high resolution tick
* related events.
*
* Copyright(C) 2005-2006, Thomas Gleixner <tglx@linutronix.de>
* Copyright(C) 2005-2007, Red Hat, Inc., Ingo Molnar
* Copyright(C) 2006-2007, Timesys Corp., Thomas Gleixner
*
* This code is licenced under the GPL version 2. For details see
* kernel-base/COPYING.
*/
#include <linux/cpu.h>
#include <linux/err.h>
#include <linux/hrtimer.h>
#include <linux/interrupt.h>
#include <linux/percpu.h>
#include <linux/profile.h>
#include <linux/sched.h>
#include <linux/tick.h>
#include "tick-internal.h"
/* Limit min_delta to a jiffie */
#define MIN_DELTA_LIMIT (NSEC_PER_SEC / HZ)
static int tick_increase_min_delta(struct clock_event_device *dev)
{
/* Nothing to do if we already reached the limit */
if (dev->min_delta_ns >= MIN_DELTA_LIMIT)
return -ETIME;
if (dev->min_delta_ns < 5000)
dev->min_delta_ns = 5000;
else
dev->min_delta_ns += dev->min_delta_ns >> 1;
if (dev->min_delta_ns > MIN_DELTA_LIMIT)
dev->min_delta_ns = MIN_DELTA_LIMIT;
printk(KERN_WARNING "CE: %s increased min_delta_ns to %llu nsec\n",
dev->name ? dev->name : "?",
(unsigned long long) dev->min_delta_ns);
return 0;
}
/**
* tick_program_event internal worker function
*/
int tick_dev_program_event(struct clock_event_device *dev, ktime_t expires,
int force)
{
ktime_t now = ktime_get();
int i;
for (i = 0;;) {
int ret = clockevents_program_event(dev, expires, now);
if (!ret || !force)
return ret;
dev->retries++;
/*
* We tried 3 times to program the device with the given
* min_delta_ns. If that's not working then we increase it
* and emit a warning.
*/
if (++i > 2) {
/* Increase the min. delta and try again */
if (tick_increase_min_delta(dev)) {
/*
* Get out of the loop if min_delta_ns
* hit the limit already. That's
* better than staying here forever.
*
* We clear next_event so we have a
* chance that the box survives.
*/
printk(KERN_WARNING
"CE: Reprogramming failure. Giving up\n");
dev->next_event.tv64 = KTIME_MAX;
return -ETIME;
}
i = 0;
}
now = ktime_get();
expires = ktime_add_ns(now, dev->min_delta_ns);
}
}
/**
* tick_program_event
*/
int tick_program_event(ktime_t expires, int force)
{
struct clock_event_device *dev = __this_cpu_read(tick_cpu_device.evtdev);
return tick_dev_program_event(dev, expires, force);
}
/**
* tick_resume_onshot - resume oneshot mode
*/
void tick_resume_oneshot(void)
{
struct tick_device *td = &__get_cpu_var(tick_cpu_device);
struct clock_event_device *dev = td->evtdev;
clockevents_set_mode(dev, CLOCK_EVT_MODE_ONESHOT);
tick_program_event(ktime_get(), 1);
}
/**
* tick_setup_oneshot - setup the event device for oneshot mode (hres or nohz)
*/
void tick_setup_oneshot(struct clock_event_device *newdev,
void (*handler)(struct clock_event_device *),
ktime_t next_event)
{
newdev->event_handler = handler;
clockevents_set_mode(newdev, CLOCK_EVT_MODE_ONESHOT);
tick_dev_program_event(newdev, next_event, 1);
}
/**
* tick_switch_to_oneshot - switch to oneshot mode
*/
int tick_switch_to_oneshot(void (*handler)(struct clock_event_device *))
{
struct tick_device *td = &__get_cpu_var(tick_cpu_device);
struct clock_event_device *dev = td->evtdev;
if (!dev || !(dev->features & CLOCK_EVT_FEAT_ONESHOT) ||
!tick_device_is_functional(dev)) {
printk(KERN_INFO "Clockevents: "
"could not switch to one-shot mode:");
if (!dev) {
printk(" no tick device\n");
} else {
if (!tick_device_is_functional(dev))
printk(" %s is not functional.\n", dev->name);
else
printk(" %s does not support one-shot mode.\n",
dev->name);
}
return -EINVAL;
}
td->mode = TICKDEV_MODE_ONESHOT;
dev->event_handler = handler;
clockevents_set_mode(dev, CLOCK_EVT_MODE_ONESHOT);
tick_broadcast_switch_to_oneshot();
return 0;
}
/**
* tick_check_oneshot_mode - check whether the system is in oneshot mode
*
* returns 1 when either nohz or highres are enabled. otherwise 0.
*/
int tick_oneshot_mode_active(void)
{
unsigned long flags;
int ret;
local_irq_save(flags);
ret = __this_cpu_read(tick_cpu_device.mode) == TICKDEV_MODE_ONESHOT;
local_irq_restore(flags);
return ret;
}
#ifdef CONFIG_HIGH_RES_TIMERS
/**
* tick_init_highres - switch to high resolution mode
*
* Called with interrupts disabled.
*/
int tick_init_highres(void)
{
return tick_switch_to_oneshot(hrtimer_interrupt);
}
#endif