Add new compatible string for reset and sys-ctrl for the Oxford Semiconductor OX820 Support. Drop the OX810SE indices since they moved in a dedicated include file. Signed-off-by: Neil Armstrong <narmstrong@baylibre.com> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
33 lines
967 B
Plaintext
33 lines
967 B
Plaintext
Oxford Semiconductor OXNAS SoC Family RESET Controller
|
|
================================================
|
|
|
|
Please also refer to reset.txt in this directory for common reset
|
|
controller binding usage.
|
|
|
|
Required properties:
|
|
- compatible: For OX810SE, should be "oxsemi,ox810se-reset"
|
|
For OX820, should be "oxsemi,ox820-reset"
|
|
- #reset-cells: 1, see below
|
|
|
|
Parent node should have the following properties :
|
|
- compatible: For OX810SE, should be :
|
|
"oxsemi,ox810se-sys-ctrl", "syscon", "simple-mfd"
|
|
For OX820, should be :
|
|
"oxsemi,ox820-sys-ctrl", "syscon", "simple-mfd"
|
|
|
|
Reset indices are in dt-bindings include files :
|
|
- For OX810SE: include/dt-bindings/reset/oxsemi,ox810se.h
|
|
- For OX820: include/dt-bindings/reset/oxsemi,ox820.h
|
|
|
|
example:
|
|
|
|
sys: sys-ctrl@000000 {
|
|
compatible = "oxsemi,ox810se-sys-ctrl", "syscon", "simple-mfd";
|
|
reg = <0x000000 0x100000>;
|
|
|
|
reset: reset-controller {
|
|
compatible = "oxsemi,ox810se-reset";
|
|
#reset-cells = <1>;
|
|
};
|
|
};
|