Versions of VMD with the Host Physical Address shadow register use this
register to calculate the bus address offset needed to do guest
passthrough of the domain. This register shadows the Host Physical
Address registers including the resource type bits. After calculating
the offset, the extra resource type bits lead to the VMD resources being
over-provisioned at the front and under-provisioned at the back.
Example:
pci 10000:80:02.0: reg 0x10: [mem 0xf801fffc-0xf803fffb 64bit]
Expected:
pci 10000:80:02.0: reg 0x10: [mem 0xf8020000-0xf803ffff 64bit]
If other devices are mapped in the over-provisioned front, it could lead
to resource conflict issues with VMD or those devices.
Link: https://lore.kernel.org/r/20200528030240.16024-3-jonathan.derrick@intel.com
Fixes: a1a3017013
("PCI: vmd: Fix shadow offsets to reflect spec changes")
Signed-off-by: Jon Derrick <jonathan.derrick@intel.com>
Signed-off-by: Lorenzo Pieralisi <lorenzo.pieralisi@arm.com>
747 lines
19 KiB
C
747 lines
19 KiB
C
// SPDX-License-Identifier: GPL-2.0
|
|
/*
|
|
* Volume Management Device driver
|
|
* Copyright (c) 2015, Intel Corporation.
|
|
*/
|
|
|
|
#include <linux/device.h>
|
|
#include <linux/interrupt.h>
|
|
#include <linux/irq.h>
|
|
#include <linux/kernel.h>
|
|
#include <linux/module.h>
|
|
#include <linux/msi.h>
|
|
#include <linux/pci.h>
|
|
#include <linux/srcu.h>
|
|
#include <linux/rculist.h>
|
|
#include <linux/rcupdate.h>
|
|
|
|
#include <asm/irqdomain.h>
|
|
#include <asm/device.h>
|
|
#include <asm/msi.h>
|
|
#include <asm/msidef.h>
|
|
|
|
#define VMD_CFGBAR 0
|
|
#define VMD_MEMBAR1 2
|
|
#define VMD_MEMBAR2 4
|
|
|
|
#define PCI_REG_VMCAP 0x40
|
|
#define BUS_RESTRICT_CAP(vmcap) (vmcap & 0x1)
|
|
#define PCI_REG_VMCONFIG 0x44
|
|
#define BUS_RESTRICT_CFG(vmcfg) ((vmcfg >> 8) & 0x3)
|
|
#define PCI_REG_VMLOCK 0x70
|
|
#define MB2_SHADOW_EN(vmlock) (vmlock & 0x2)
|
|
|
|
#define MB2_SHADOW_OFFSET 0x2000
|
|
#define MB2_SHADOW_SIZE 16
|
|
|
|
enum vmd_features {
|
|
/*
|
|
* Device may contain registers which hint the physical location of the
|
|
* membars, in order to allow proper address translation during
|
|
* resource assignment to enable guest virtualization
|
|
*/
|
|
VMD_FEAT_HAS_MEMBAR_SHADOW = (1 << 0),
|
|
|
|
/*
|
|
* Device may provide root port configuration information which limits
|
|
* bus numbering
|
|
*/
|
|
VMD_FEAT_HAS_BUS_RESTRICTIONS = (1 << 1),
|
|
};
|
|
|
|
/*
|
|
* Lock for manipulating VMD IRQ lists.
|
|
*/
|
|
static DEFINE_RAW_SPINLOCK(list_lock);
|
|
|
|
/**
|
|
* struct vmd_irq - private data to map driver IRQ to the VMD shared vector
|
|
* @node: list item for parent traversal.
|
|
* @irq: back pointer to parent.
|
|
* @enabled: true if driver enabled IRQ
|
|
* @virq: the virtual IRQ value provided to the requesting driver.
|
|
*
|
|
* Every MSI/MSI-X IRQ requested for a device in a VMD domain will be mapped to
|
|
* a VMD IRQ using this structure.
|
|
*/
|
|
struct vmd_irq {
|
|
struct list_head node;
|
|
struct vmd_irq_list *irq;
|
|
bool enabled;
|
|
unsigned int virq;
|
|
};
|
|
|
|
/**
|
|
* struct vmd_irq_list - list of driver requested IRQs mapping to a VMD vector
|
|
* @irq_list: the list of irq's the VMD one demuxes to.
|
|
* @srcu: SRCU struct for local synchronization.
|
|
* @count: number of child IRQs assigned to this vector; used to track
|
|
* sharing.
|
|
*/
|
|
struct vmd_irq_list {
|
|
struct list_head irq_list;
|
|
struct srcu_struct srcu;
|
|
unsigned int count;
|
|
};
|
|
|
|
struct vmd_dev {
|
|
struct pci_dev *dev;
|
|
|
|
spinlock_t cfg_lock;
|
|
char __iomem *cfgbar;
|
|
|
|
int msix_count;
|
|
struct vmd_irq_list *irqs;
|
|
|
|
struct pci_sysdata sysdata;
|
|
struct resource resources[3];
|
|
struct irq_domain *irq_domain;
|
|
struct pci_bus *bus;
|
|
u8 busn_start;
|
|
};
|
|
|
|
static inline struct vmd_dev *vmd_from_bus(struct pci_bus *bus)
|
|
{
|
|
return container_of(bus->sysdata, struct vmd_dev, sysdata);
|
|
}
|
|
|
|
static inline unsigned int index_from_irqs(struct vmd_dev *vmd,
|
|
struct vmd_irq_list *irqs)
|
|
{
|
|
return irqs - vmd->irqs;
|
|
}
|
|
|
|
/*
|
|
* Drivers managing a device in a VMD domain allocate their own IRQs as before,
|
|
* but the MSI entry for the hardware it's driving will be programmed with a
|
|
* destination ID for the VMD MSI-X table. The VMD muxes interrupts in its
|
|
* domain into one of its own, and the VMD driver de-muxes these for the
|
|
* handlers sharing that VMD IRQ. The vmd irq_domain provides the operations
|
|
* and irq_chip to set this up.
|
|
*/
|
|
static void vmd_compose_msi_msg(struct irq_data *data, struct msi_msg *msg)
|
|
{
|
|
struct vmd_irq *vmdirq = data->chip_data;
|
|
struct vmd_irq_list *irq = vmdirq->irq;
|
|
struct vmd_dev *vmd = irq_data_get_irq_handler_data(data);
|
|
|
|
msg->address_hi = MSI_ADDR_BASE_HI;
|
|
msg->address_lo = MSI_ADDR_BASE_LO |
|
|
MSI_ADDR_DEST_ID(index_from_irqs(vmd, irq));
|
|
msg->data = 0;
|
|
}
|
|
|
|
/*
|
|
* We rely on MSI_FLAG_USE_DEF_CHIP_OPS to set the IRQ mask/unmask ops.
|
|
*/
|
|
static void vmd_irq_enable(struct irq_data *data)
|
|
{
|
|
struct vmd_irq *vmdirq = data->chip_data;
|
|
unsigned long flags;
|
|
|
|
raw_spin_lock_irqsave(&list_lock, flags);
|
|
WARN_ON(vmdirq->enabled);
|
|
list_add_tail_rcu(&vmdirq->node, &vmdirq->irq->irq_list);
|
|
vmdirq->enabled = true;
|
|
raw_spin_unlock_irqrestore(&list_lock, flags);
|
|
|
|
data->chip->irq_unmask(data);
|
|
}
|
|
|
|
static void vmd_irq_disable(struct irq_data *data)
|
|
{
|
|
struct vmd_irq *vmdirq = data->chip_data;
|
|
unsigned long flags;
|
|
|
|
data->chip->irq_mask(data);
|
|
|
|
raw_spin_lock_irqsave(&list_lock, flags);
|
|
if (vmdirq->enabled) {
|
|
list_del_rcu(&vmdirq->node);
|
|
vmdirq->enabled = false;
|
|
}
|
|
raw_spin_unlock_irqrestore(&list_lock, flags);
|
|
}
|
|
|
|
/*
|
|
* XXX: Stubbed until we develop acceptable way to not create conflicts with
|
|
* other devices sharing the same vector.
|
|
*/
|
|
static int vmd_irq_set_affinity(struct irq_data *data,
|
|
const struct cpumask *dest, bool force)
|
|
{
|
|
return -EINVAL;
|
|
}
|
|
|
|
static struct irq_chip vmd_msi_controller = {
|
|
.name = "VMD-MSI",
|
|
.irq_enable = vmd_irq_enable,
|
|
.irq_disable = vmd_irq_disable,
|
|
.irq_compose_msi_msg = vmd_compose_msi_msg,
|
|
.irq_set_affinity = vmd_irq_set_affinity,
|
|
};
|
|
|
|
static irq_hw_number_t vmd_get_hwirq(struct msi_domain_info *info,
|
|
msi_alloc_info_t *arg)
|
|
{
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* XXX: We can be even smarter selecting the best IRQ once we solve the
|
|
* affinity problem.
|
|
*/
|
|
static struct vmd_irq_list *vmd_next_irq(struct vmd_dev *vmd, struct msi_desc *desc)
|
|
{
|
|
int i, best = 1;
|
|
unsigned long flags;
|
|
|
|
if (vmd->msix_count == 1)
|
|
return &vmd->irqs[0];
|
|
|
|
/*
|
|
* White list for fast-interrupt handlers. All others will share the
|
|
* "slow" interrupt vector.
|
|
*/
|
|
switch (msi_desc_to_pci_dev(desc)->class) {
|
|
case PCI_CLASS_STORAGE_EXPRESS:
|
|
break;
|
|
default:
|
|
return &vmd->irqs[0];
|
|
}
|
|
|
|
raw_spin_lock_irqsave(&list_lock, flags);
|
|
for (i = 1; i < vmd->msix_count; i++)
|
|
if (vmd->irqs[i].count < vmd->irqs[best].count)
|
|
best = i;
|
|
vmd->irqs[best].count++;
|
|
raw_spin_unlock_irqrestore(&list_lock, flags);
|
|
|
|
return &vmd->irqs[best];
|
|
}
|
|
|
|
static int vmd_msi_init(struct irq_domain *domain, struct msi_domain_info *info,
|
|
unsigned int virq, irq_hw_number_t hwirq,
|
|
msi_alloc_info_t *arg)
|
|
{
|
|
struct msi_desc *desc = arg->desc;
|
|
struct vmd_dev *vmd = vmd_from_bus(msi_desc_to_pci_dev(desc)->bus);
|
|
struct vmd_irq *vmdirq = kzalloc(sizeof(*vmdirq), GFP_KERNEL);
|
|
unsigned int index, vector;
|
|
|
|
if (!vmdirq)
|
|
return -ENOMEM;
|
|
|
|
INIT_LIST_HEAD(&vmdirq->node);
|
|
vmdirq->irq = vmd_next_irq(vmd, desc);
|
|
vmdirq->virq = virq;
|
|
index = index_from_irqs(vmd, vmdirq->irq);
|
|
vector = pci_irq_vector(vmd->dev, index);
|
|
|
|
irq_domain_set_info(domain, virq, vector, info->chip, vmdirq,
|
|
handle_untracked_irq, vmd, NULL);
|
|
return 0;
|
|
}
|
|
|
|
static void vmd_msi_free(struct irq_domain *domain,
|
|
struct msi_domain_info *info, unsigned int virq)
|
|
{
|
|
struct vmd_irq *vmdirq = irq_get_chip_data(virq);
|
|
unsigned long flags;
|
|
|
|
synchronize_srcu(&vmdirq->irq->srcu);
|
|
|
|
/* XXX: Potential optimization to rebalance */
|
|
raw_spin_lock_irqsave(&list_lock, flags);
|
|
vmdirq->irq->count--;
|
|
raw_spin_unlock_irqrestore(&list_lock, flags);
|
|
|
|
kfree(vmdirq);
|
|
}
|
|
|
|
static int vmd_msi_prepare(struct irq_domain *domain, struct device *dev,
|
|
int nvec, msi_alloc_info_t *arg)
|
|
{
|
|
struct pci_dev *pdev = to_pci_dev(dev);
|
|
struct vmd_dev *vmd = vmd_from_bus(pdev->bus);
|
|
|
|
if (nvec > vmd->msix_count)
|
|
return vmd->msix_count;
|
|
|
|
memset(arg, 0, sizeof(*arg));
|
|
return 0;
|
|
}
|
|
|
|
static void vmd_set_desc(msi_alloc_info_t *arg, struct msi_desc *desc)
|
|
{
|
|
arg->desc = desc;
|
|
}
|
|
|
|
static struct msi_domain_ops vmd_msi_domain_ops = {
|
|
.get_hwirq = vmd_get_hwirq,
|
|
.msi_init = vmd_msi_init,
|
|
.msi_free = vmd_msi_free,
|
|
.msi_prepare = vmd_msi_prepare,
|
|
.set_desc = vmd_set_desc,
|
|
};
|
|
|
|
static struct msi_domain_info vmd_msi_domain_info = {
|
|
.flags = MSI_FLAG_USE_DEF_DOM_OPS | MSI_FLAG_USE_DEF_CHIP_OPS |
|
|
MSI_FLAG_PCI_MSIX,
|
|
.ops = &vmd_msi_domain_ops,
|
|
.chip = &vmd_msi_controller,
|
|
};
|
|
|
|
static char __iomem *vmd_cfg_addr(struct vmd_dev *vmd, struct pci_bus *bus,
|
|
unsigned int devfn, int reg, int len)
|
|
{
|
|
char __iomem *addr = vmd->cfgbar +
|
|
((bus->number - vmd->busn_start) << 20) +
|
|
(devfn << 12) + reg;
|
|
|
|
if ((addr - vmd->cfgbar) + len >=
|
|
resource_size(&vmd->dev->resource[VMD_CFGBAR]))
|
|
return NULL;
|
|
|
|
return addr;
|
|
}
|
|
|
|
/*
|
|
* CPU may deadlock if config space is not serialized on some versions of this
|
|
* hardware, so all config space access is done under a spinlock.
|
|
*/
|
|
static int vmd_pci_read(struct pci_bus *bus, unsigned int devfn, int reg,
|
|
int len, u32 *value)
|
|
{
|
|
struct vmd_dev *vmd = vmd_from_bus(bus);
|
|
char __iomem *addr = vmd_cfg_addr(vmd, bus, devfn, reg, len);
|
|
unsigned long flags;
|
|
int ret = 0;
|
|
|
|
if (!addr)
|
|
return -EFAULT;
|
|
|
|
spin_lock_irqsave(&vmd->cfg_lock, flags);
|
|
switch (len) {
|
|
case 1:
|
|
*value = readb(addr);
|
|
break;
|
|
case 2:
|
|
*value = readw(addr);
|
|
break;
|
|
case 4:
|
|
*value = readl(addr);
|
|
break;
|
|
default:
|
|
ret = -EINVAL;
|
|
break;
|
|
}
|
|
spin_unlock_irqrestore(&vmd->cfg_lock, flags);
|
|
return ret;
|
|
}
|
|
|
|
/*
|
|
* VMD h/w converts non-posted config writes to posted memory writes. The
|
|
* read-back in this function forces the completion so it returns only after
|
|
* the config space was written, as expected.
|
|
*/
|
|
static int vmd_pci_write(struct pci_bus *bus, unsigned int devfn, int reg,
|
|
int len, u32 value)
|
|
{
|
|
struct vmd_dev *vmd = vmd_from_bus(bus);
|
|
char __iomem *addr = vmd_cfg_addr(vmd, bus, devfn, reg, len);
|
|
unsigned long flags;
|
|
int ret = 0;
|
|
|
|
if (!addr)
|
|
return -EFAULT;
|
|
|
|
spin_lock_irqsave(&vmd->cfg_lock, flags);
|
|
switch (len) {
|
|
case 1:
|
|
writeb(value, addr);
|
|
readb(addr);
|
|
break;
|
|
case 2:
|
|
writew(value, addr);
|
|
readw(addr);
|
|
break;
|
|
case 4:
|
|
writel(value, addr);
|
|
readl(addr);
|
|
break;
|
|
default:
|
|
ret = -EINVAL;
|
|
break;
|
|
}
|
|
spin_unlock_irqrestore(&vmd->cfg_lock, flags);
|
|
return ret;
|
|
}
|
|
|
|
static struct pci_ops vmd_ops = {
|
|
.read = vmd_pci_read,
|
|
.write = vmd_pci_write,
|
|
};
|
|
|
|
static void vmd_attach_resources(struct vmd_dev *vmd)
|
|
{
|
|
vmd->dev->resource[VMD_MEMBAR1].child = &vmd->resources[1];
|
|
vmd->dev->resource[VMD_MEMBAR2].child = &vmd->resources[2];
|
|
}
|
|
|
|
static void vmd_detach_resources(struct vmd_dev *vmd)
|
|
{
|
|
vmd->dev->resource[VMD_MEMBAR1].child = NULL;
|
|
vmd->dev->resource[VMD_MEMBAR2].child = NULL;
|
|
}
|
|
|
|
/*
|
|
* VMD domains start at 0x10000 to not clash with ACPI _SEG domains.
|
|
* Per ACPI r6.0, sec 6.5.6, _SEG returns an integer, of which the lower
|
|
* 16 bits are the PCI Segment Group (domain) number. Other bits are
|
|
* currently reserved.
|
|
*/
|
|
static int vmd_find_free_domain(void)
|
|
{
|
|
int domain = 0xffff;
|
|
struct pci_bus *bus = NULL;
|
|
|
|
while ((bus = pci_find_next_bus(bus)) != NULL)
|
|
domain = max_t(int, domain, pci_domain_nr(bus));
|
|
return domain + 1;
|
|
}
|
|
|
|
static int vmd_enable_domain(struct vmd_dev *vmd, unsigned long features)
|
|
{
|
|
struct pci_sysdata *sd = &vmd->sysdata;
|
|
struct fwnode_handle *fn;
|
|
struct resource *res;
|
|
u32 upper_bits;
|
|
unsigned long flags;
|
|
LIST_HEAD(resources);
|
|
resource_size_t offset[2] = {0};
|
|
resource_size_t membar2_offset = 0x2000;
|
|
struct pci_bus *child;
|
|
|
|
/*
|
|
* Shadow registers may exist in certain VMD device ids which allow
|
|
* guests to correctly assign host physical addresses to the root ports
|
|
* and child devices. These registers will either return the host value
|
|
* or 0, depending on an enable bit in the VMD device.
|
|
*/
|
|
if (features & VMD_FEAT_HAS_MEMBAR_SHADOW) {
|
|
u32 vmlock;
|
|
int ret;
|
|
|
|
membar2_offset = MB2_SHADOW_OFFSET + MB2_SHADOW_SIZE;
|
|
ret = pci_read_config_dword(vmd->dev, PCI_REG_VMLOCK, &vmlock);
|
|
if (ret || vmlock == ~0)
|
|
return -ENODEV;
|
|
|
|
if (MB2_SHADOW_EN(vmlock)) {
|
|
void __iomem *membar2;
|
|
|
|
membar2 = pci_iomap(vmd->dev, VMD_MEMBAR2, 0);
|
|
if (!membar2)
|
|
return -ENOMEM;
|
|
offset[0] = vmd->dev->resource[VMD_MEMBAR1].start -
|
|
(readq(membar2 + MB2_SHADOW_OFFSET) &
|
|
PCI_BASE_ADDRESS_MEM_MASK);
|
|
offset[1] = vmd->dev->resource[VMD_MEMBAR2].start -
|
|
(readq(membar2 + MB2_SHADOW_OFFSET + 8) &
|
|
PCI_BASE_ADDRESS_MEM_MASK);
|
|
pci_iounmap(vmd->dev, membar2);
|
|
}
|
|
}
|
|
|
|
/*
|
|
* Certain VMD devices may have a root port configuration option which
|
|
* limits the bus range to between 0-127, 128-255, or 224-255
|
|
*/
|
|
if (features & VMD_FEAT_HAS_BUS_RESTRICTIONS) {
|
|
u16 reg16;
|
|
|
|
pci_read_config_word(vmd->dev, PCI_REG_VMCAP, ®16);
|
|
if (BUS_RESTRICT_CAP(reg16)) {
|
|
pci_read_config_word(vmd->dev, PCI_REG_VMCONFIG,
|
|
®16);
|
|
|
|
switch (BUS_RESTRICT_CFG(reg16)) {
|
|
case 1:
|
|
vmd->busn_start = 128;
|
|
break;
|
|
case 2:
|
|
vmd->busn_start = 224;
|
|
break;
|
|
case 3:
|
|
pci_err(vmd->dev, "Unknown Bus Offset Setting\n");
|
|
return -ENODEV;
|
|
default:
|
|
break;
|
|
}
|
|
}
|
|
}
|
|
|
|
res = &vmd->dev->resource[VMD_CFGBAR];
|
|
vmd->resources[0] = (struct resource) {
|
|
.name = "VMD CFGBAR",
|
|
.start = vmd->busn_start,
|
|
.end = vmd->busn_start + (resource_size(res) >> 20) - 1,
|
|
.flags = IORESOURCE_BUS | IORESOURCE_PCI_FIXED,
|
|
};
|
|
|
|
/*
|
|
* If the window is below 4GB, clear IORESOURCE_MEM_64 so we can
|
|
* put 32-bit resources in the window.
|
|
*
|
|
* There's no hardware reason why a 64-bit window *couldn't*
|
|
* contain a 32-bit resource, but pbus_size_mem() computes the
|
|
* bridge window size assuming a 64-bit window will contain no
|
|
* 32-bit resources. __pci_assign_resource() enforces that
|
|
* artificial restriction to make sure everything will fit.
|
|
*
|
|
* The only way we could use a 64-bit non-prefetchable MEMBAR is
|
|
* if its address is <4GB so that we can convert it to a 32-bit
|
|
* resource. To be visible to the host OS, all VMD endpoints must
|
|
* be initially configured by platform BIOS, which includes setting
|
|
* up these resources. We can assume the device is configured
|
|
* according to the platform needs.
|
|
*/
|
|
res = &vmd->dev->resource[VMD_MEMBAR1];
|
|
upper_bits = upper_32_bits(res->end);
|
|
flags = res->flags & ~IORESOURCE_SIZEALIGN;
|
|
if (!upper_bits)
|
|
flags &= ~IORESOURCE_MEM_64;
|
|
vmd->resources[1] = (struct resource) {
|
|
.name = "VMD MEMBAR1",
|
|
.start = res->start,
|
|
.end = res->end,
|
|
.flags = flags,
|
|
.parent = res,
|
|
};
|
|
|
|
res = &vmd->dev->resource[VMD_MEMBAR2];
|
|
upper_bits = upper_32_bits(res->end);
|
|
flags = res->flags & ~IORESOURCE_SIZEALIGN;
|
|
if (!upper_bits)
|
|
flags &= ~IORESOURCE_MEM_64;
|
|
vmd->resources[2] = (struct resource) {
|
|
.name = "VMD MEMBAR2",
|
|
.start = res->start + membar2_offset,
|
|
.end = res->end,
|
|
.flags = flags,
|
|
.parent = res,
|
|
};
|
|
|
|
sd->vmd_dev = vmd->dev;
|
|
sd->domain = vmd_find_free_domain();
|
|
if (sd->domain < 0)
|
|
return sd->domain;
|
|
|
|
sd->node = pcibus_to_node(vmd->dev->bus);
|
|
|
|
fn = irq_domain_alloc_named_id_fwnode("VMD-MSI", vmd->sysdata.domain);
|
|
if (!fn)
|
|
return -ENODEV;
|
|
|
|
vmd->irq_domain = pci_msi_create_irq_domain(fn, &vmd_msi_domain_info,
|
|
x86_vector_domain);
|
|
irq_domain_free_fwnode(fn);
|
|
if (!vmd->irq_domain)
|
|
return -ENODEV;
|
|
|
|
pci_add_resource(&resources, &vmd->resources[0]);
|
|
pci_add_resource_offset(&resources, &vmd->resources[1], offset[0]);
|
|
pci_add_resource_offset(&resources, &vmd->resources[2], offset[1]);
|
|
|
|
vmd->bus = pci_create_root_bus(&vmd->dev->dev, vmd->busn_start,
|
|
&vmd_ops, sd, &resources);
|
|
if (!vmd->bus) {
|
|
pci_free_resource_list(&resources);
|
|
irq_domain_remove(vmd->irq_domain);
|
|
return -ENODEV;
|
|
}
|
|
|
|
vmd_attach_resources(vmd);
|
|
dev_set_msi_domain(&vmd->bus->dev, vmd->irq_domain);
|
|
|
|
pci_scan_child_bus(vmd->bus);
|
|
pci_assign_unassigned_bus_resources(vmd->bus);
|
|
|
|
/*
|
|
* VMD root buses are virtual and don't return true on pci_is_pcie()
|
|
* and will fail pcie_bus_configure_settings() early. It can instead be
|
|
* run on each of the real root ports.
|
|
*/
|
|
list_for_each_entry(child, &vmd->bus->children, node)
|
|
pcie_bus_configure_settings(child);
|
|
|
|
pci_bus_add_devices(vmd->bus);
|
|
|
|
WARN(sysfs_create_link(&vmd->dev->dev.kobj, &vmd->bus->dev.kobj,
|
|
"domain"), "Can't create symlink to domain\n");
|
|
return 0;
|
|
}
|
|
|
|
static irqreturn_t vmd_irq(int irq, void *data)
|
|
{
|
|
struct vmd_irq_list *irqs = data;
|
|
struct vmd_irq *vmdirq;
|
|
int idx;
|
|
|
|
idx = srcu_read_lock(&irqs->srcu);
|
|
list_for_each_entry_rcu(vmdirq, &irqs->irq_list, node)
|
|
generic_handle_irq(vmdirq->virq);
|
|
srcu_read_unlock(&irqs->srcu, idx);
|
|
|
|
return IRQ_HANDLED;
|
|
}
|
|
|
|
static int vmd_probe(struct pci_dev *dev, const struct pci_device_id *id)
|
|
{
|
|
struct vmd_dev *vmd;
|
|
int i, err;
|
|
|
|
if (resource_size(&dev->resource[VMD_CFGBAR]) < (1 << 20))
|
|
return -ENOMEM;
|
|
|
|
vmd = devm_kzalloc(&dev->dev, sizeof(*vmd), GFP_KERNEL);
|
|
if (!vmd)
|
|
return -ENOMEM;
|
|
|
|
vmd->dev = dev;
|
|
err = pcim_enable_device(dev);
|
|
if (err < 0)
|
|
return err;
|
|
|
|
vmd->cfgbar = pcim_iomap(dev, VMD_CFGBAR, 0);
|
|
if (!vmd->cfgbar)
|
|
return -ENOMEM;
|
|
|
|
pci_set_master(dev);
|
|
if (dma_set_mask_and_coherent(&dev->dev, DMA_BIT_MASK(64)) &&
|
|
dma_set_mask_and_coherent(&dev->dev, DMA_BIT_MASK(32)))
|
|
return -ENODEV;
|
|
|
|
vmd->msix_count = pci_msix_vec_count(dev);
|
|
if (vmd->msix_count < 0)
|
|
return -ENODEV;
|
|
|
|
vmd->msix_count = pci_alloc_irq_vectors(dev, 1, vmd->msix_count,
|
|
PCI_IRQ_MSIX);
|
|
if (vmd->msix_count < 0)
|
|
return vmd->msix_count;
|
|
|
|
vmd->irqs = devm_kcalloc(&dev->dev, vmd->msix_count, sizeof(*vmd->irqs),
|
|
GFP_KERNEL);
|
|
if (!vmd->irqs)
|
|
return -ENOMEM;
|
|
|
|
for (i = 0; i < vmd->msix_count; i++) {
|
|
err = init_srcu_struct(&vmd->irqs[i].srcu);
|
|
if (err)
|
|
return err;
|
|
|
|
INIT_LIST_HEAD(&vmd->irqs[i].irq_list);
|
|
err = devm_request_irq(&dev->dev, pci_irq_vector(dev, i),
|
|
vmd_irq, IRQF_NO_THREAD,
|
|
"vmd", &vmd->irqs[i]);
|
|
if (err)
|
|
return err;
|
|
}
|
|
|
|
spin_lock_init(&vmd->cfg_lock);
|
|
pci_set_drvdata(dev, vmd);
|
|
err = vmd_enable_domain(vmd, (unsigned long) id->driver_data);
|
|
if (err)
|
|
return err;
|
|
|
|
dev_info(&vmd->dev->dev, "Bound to PCI domain %04x\n",
|
|
vmd->sysdata.domain);
|
|
return 0;
|
|
}
|
|
|
|
static void vmd_cleanup_srcu(struct vmd_dev *vmd)
|
|
{
|
|
int i;
|
|
|
|
for (i = 0; i < vmd->msix_count; i++)
|
|
cleanup_srcu_struct(&vmd->irqs[i].srcu);
|
|
}
|
|
|
|
static void vmd_remove(struct pci_dev *dev)
|
|
{
|
|
struct vmd_dev *vmd = pci_get_drvdata(dev);
|
|
|
|
sysfs_remove_link(&vmd->dev->dev.kobj, "domain");
|
|
pci_stop_root_bus(vmd->bus);
|
|
pci_remove_root_bus(vmd->bus);
|
|
vmd_cleanup_srcu(vmd);
|
|
vmd_detach_resources(vmd);
|
|
irq_domain_remove(vmd->irq_domain);
|
|
}
|
|
|
|
#ifdef CONFIG_PM_SLEEP
|
|
static int vmd_suspend(struct device *dev)
|
|
{
|
|
struct pci_dev *pdev = to_pci_dev(dev);
|
|
struct vmd_dev *vmd = pci_get_drvdata(pdev);
|
|
int i;
|
|
|
|
for (i = 0; i < vmd->msix_count; i++)
|
|
devm_free_irq(dev, pci_irq_vector(pdev, i), &vmd->irqs[i]);
|
|
|
|
pci_save_state(pdev);
|
|
return 0;
|
|
}
|
|
|
|
static int vmd_resume(struct device *dev)
|
|
{
|
|
struct pci_dev *pdev = to_pci_dev(dev);
|
|
struct vmd_dev *vmd = pci_get_drvdata(pdev);
|
|
int err, i;
|
|
|
|
for (i = 0; i < vmd->msix_count; i++) {
|
|
err = devm_request_irq(dev, pci_irq_vector(pdev, i),
|
|
vmd_irq, IRQF_NO_THREAD,
|
|
"vmd", &vmd->irqs[i]);
|
|
if (err)
|
|
return err;
|
|
}
|
|
|
|
pci_restore_state(pdev);
|
|
return 0;
|
|
}
|
|
#endif
|
|
static SIMPLE_DEV_PM_OPS(vmd_dev_pm_ops, vmd_suspend, vmd_resume);
|
|
|
|
static const struct pci_device_id vmd_ids[] = {
|
|
{PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_VMD_201D),},
|
|
{PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_VMD_28C0),
|
|
.driver_data = VMD_FEAT_HAS_MEMBAR_SHADOW |
|
|
VMD_FEAT_HAS_BUS_RESTRICTIONS,},
|
|
{PCI_DEVICE(PCI_VENDOR_ID_INTEL, 0x467f),
|
|
.driver_data = VMD_FEAT_HAS_BUS_RESTRICTIONS,},
|
|
{PCI_DEVICE(PCI_VENDOR_ID_INTEL, 0x4c3d),
|
|
.driver_data = VMD_FEAT_HAS_BUS_RESTRICTIONS,},
|
|
{PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_VMD_9A0B),
|
|
.driver_data = VMD_FEAT_HAS_BUS_RESTRICTIONS,},
|
|
{0,}
|
|
};
|
|
MODULE_DEVICE_TABLE(pci, vmd_ids);
|
|
|
|
static struct pci_driver vmd_drv = {
|
|
.name = "vmd",
|
|
.id_table = vmd_ids,
|
|
.probe = vmd_probe,
|
|
.remove = vmd_remove,
|
|
.driver = {
|
|
.pm = &vmd_dev_pm_ops,
|
|
},
|
|
};
|
|
module_pci_driver(vmd_drv);
|
|
|
|
MODULE_AUTHOR("Intel Corporation");
|
|
MODULE_LICENSE("GPL v2");
|
|
MODULE_VERSION("0.6");
|