mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-12-19 00:54:41 +08:00
fd4d58d1fe
For USB4 v2 routers we can also enable CL2 which allows better power savings and thermal management than CL0s and CL1. Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
424 lines
9.2 KiB
C
424 lines
9.2 KiB
C
// SPDX-License-Identifier: GPL-2.0
|
|
/*
|
|
* CLx support
|
|
*
|
|
* Copyright (C) 2020 - 2023, Intel Corporation
|
|
* Authors: Gil Fine <gil.fine@intel.com>
|
|
* Mika Westerberg <mika.westerberg@linux.intel.com>
|
|
*/
|
|
|
|
#include <linux/module.h>
|
|
|
|
#include "tb.h"
|
|
|
|
static bool clx_enabled = true;
|
|
module_param_named(clx, clx_enabled, bool, 0444);
|
|
MODULE_PARM_DESC(clx, "allow low power states on the high-speed lanes (default: true)");
|
|
|
|
static const char *clx_name(unsigned int clx)
|
|
{
|
|
switch (clx) {
|
|
case TB_CL0S | TB_CL1 | TB_CL2:
|
|
return "CL0s/CL1/CL2";
|
|
case TB_CL1 | TB_CL2:
|
|
return "CL1/CL2";
|
|
case TB_CL0S | TB_CL2:
|
|
return "CL0s/CL2";
|
|
case TB_CL0S | TB_CL1:
|
|
return "CL0s/CL1";
|
|
case TB_CL0S:
|
|
return "CL0s";
|
|
case 0:
|
|
return "disabled";
|
|
default:
|
|
return "unknown";
|
|
}
|
|
}
|
|
|
|
static int tb_port_pm_secondary_set(struct tb_port *port, bool secondary)
|
|
{
|
|
u32 phy;
|
|
int ret;
|
|
|
|
ret = tb_port_read(port, &phy, TB_CFG_PORT,
|
|
port->cap_phy + LANE_ADP_CS_1, 1);
|
|
if (ret)
|
|
return ret;
|
|
|
|
if (secondary)
|
|
phy |= LANE_ADP_CS_1_PMS;
|
|
else
|
|
phy &= ~LANE_ADP_CS_1_PMS;
|
|
|
|
return tb_port_write(port, &phy, TB_CFG_PORT,
|
|
port->cap_phy + LANE_ADP_CS_1, 1);
|
|
}
|
|
|
|
static int tb_port_pm_secondary_enable(struct tb_port *port)
|
|
{
|
|
return tb_port_pm_secondary_set(port, true);
|
|
}
|
|
|
|
static int tb_port_pm_secondary_disable(struct tb_port *port)
|
|
{
|
|
return tb_port_pm_secondary_set(port, false);
|
|
}
|
|
|
|
/* Called for USB4 or Titan Ridge routers only */
|
|
static bool tb_port_clx_supported(struct tb_port *port, unsigned int clx)
|
|
{
|
|
u32 val, mask = 0;
|
|
bool ret;
|
|
|
|
/* Don't enable CLx in case of two single-lane links */
|
|
if (!port->bonded && port->dual_link_port)
|
|
return false;
|
|
|
|
/* Don't enable CLx in case of inter-domain link */
|
|
if (port->xdomain)
|
|
return false;
|
|
|
|
if (tb_switch_is_usb4(port->sw)) {
|
|
if (!usb4_port_clx_supported(port))
|
|
return false;
|
|
} else if (!tb_lc_is_clx_supported(port)) {
|
|
return false;
|
|
}
|
|
|
|
if (clx & TB_CL0S)
|
|
mask |= LANE_ADP_CS_0_CL0S_SUPPORT;
|
|
if (clx & TB_CL1)
|
|
mask |= LANE_ADP_CS_0_CL1_SUPPORT;
|
|
if (clx & TB_CL2)
|
|
mask |= LANE_ADP_CS_0_CL2_SUPPORT;
|
|
|
|
ret = tb_port_read(port, &val, TB_CFG_PORT,
|
|
port->cap_phy + LANE_ADP_CS_0, 1);
|
|
if (ret)
|
|
return false;
|
|
|
|
return !!(val & mask);
|
|
}
|
|
|
|
static int tb_port_clx_set(struct tb_port *port, unsigned int clx, bool enable)
|
|
{
|
|
u32 phy, mask = 0;
|
|
int ret;
|
|
|
|
if (clx & TB_CL0S)
|
|
mask |= LANE_ADP_CS_1_CL0S_ENABLE;
|
|
if (clx & TB_CL1)
|
|
mask |= LANE_ADP_CS_1_CL1_ENABLE;
|
|
if (clx & TB_CL2)
|
|
mask |= LANE_ADP_CS_1_CL2_ENABLE;
|
|
|
|
if (!mask)
|
|
return -EOPNOTSUPP;
|
|
|
|
ret = tb_port_read(port, &phy, TB_CFG_PORT,
|
|
port->cap_phy + LANE_ADP_CS_1, 1);
|
|
if (ret)
|
|
return ret;
|
|
|
|
if (enable)
|
|
phy |= mask;
|
|
else
|
|
phy &= ~mask;
|
|
|
|
return tb_port_write(port, &phy, TB_CFG_PORT,
|
|
port->cap_phy + LANE_ADP_CS_1, 1);
|
|
}
|
|
|
|
static int tb_port_clx_disable(struct tb_port *port, unsigned int clx)
|
|
{
|
|
return tb_port_clx_set(port, clx, false);
|
|
}
|
|
|
|
static int tb_port_clx_enable(struct tb_port *port, unsigned int clx)
|
|
{
|
|
return tb_port_clx_set(port, clx, true);
|
|
}
|
|
|
|
static int tb_port_clx(struct tb_port *port)
|
|
{
|
|
u32 val;
|
|
int ret;
|
|
|
|
if (!tb_port_clx_supported(port, TB_CL0S | TB_CL1 | TB_CL2))
|
|
return 0;
|
|
|
|
ret = tb_port_read(port, &val, TB_CFG_PORT,
|
|
port->cap_phy + LANE_ADP_CS_1, 1);
|
|
if (ret)
|
|
return ret;
|
|
|
|
if (val & LANE_ADP_CS_1_CL0S_ENABLE)
|
|
ret |= TB_CL0S;
|
|
if (val & LANE_ADP_CS_1_CL1_ENABLE)
|
|
ret |= TB_CL1;
|
|
if (val & LANE_ADP_CS_1_CL2_ENABLE)
|
|
ret |= TB_CL2;
|
|
|
|
return ret;
|
|
}
|
|
|
|
/**
|
|
* tb_port_clx_is_enabled() - Is given CL state enabled
|
|
* @port: USB4 port to check
|
|
* @clx: Mask of CL states to check
|
|
*
|
|
* Returns true if any of the given CL states is enabled for @port.
|
|
*/
|
|
bool tb_port_clx_is_enabled(struct tb_port *port, unsigned int clx)
|
|
{
|
|
return !!(tb_port_clx(port) & clx);
|
|
}
|
|
|
|
/**
|
|
* tb_switch_clx_init() - Initialize router CL states
|
|
* @sw: Router
|
|
*
|
|
* Can be called for any router. Initializes the current CL state by
|
|
* reading it from the hardware.
|
|
*
|
|
* Returns %0 in case of success and negative errno in case of failure.
|
|
*/
|
|
int tb_switch_clx_init(struct tb_switch *sw)
|
|
{
|
|
struct tb_port *up, *down;
|
|
unsigned int clx, tmp;
|
|
|
|
if (tb_switch_is_icm(sw))
|
|
return 0;
|
|
|
|
if (!tb_route(sw))
|
|
return 0;
|
|
|
|
if (!tb_switch_clx_is_supported(sw))
|
|
return 0;
|
|
|
|
up = tb_upstream_port(sw);
|
|
down = tb_switch_downstream_port(sw);
|
|
|
|
clx = tb_port_clx(up);
|
|
tmp = tb_port_clx(down);
|
|
if (clx != tmp)
|
|
tb_sw_warn(sw, "CLx: inconsistent configuration %#x != %#x\n",
|
|
clx, tmp);
|
|
|
|
tb_sw_dbg(sw, "CLx: current mode: %s\n", clx_name(clx));
|
|
|
|
sw->clx = clx;
|
|
return 0;
|
|
}
|
|
|
|
static int tb_switch_pm_secondary_resolve(struct tb_switch *sw)
|
|
{
|
|
struct tb_port *up, *down;
|
|
int ret;
|
|
|
|
if (!tb_route(sw))
|
|
return 0;
|
|
|
|
up = tb_upstream_port(sw);
|
|
down = tb_switch_downstream_port(sw);
|
|
ret = tb_port_pm_secondary_enable(up);
|
|
if (ret)
|
|
return ret;
|
|
|
|
return tb_port_pm_secondary_disable(down);
|
|
}
|
|
|
|
static int tb_switch_mask_clx_objections(struct tb_switch *sw)
|
|
{
|
|
int up_port = sw->config.upstream_port_number;
|
|
u32 offset, val[2], mask_obj, unmask_obj;
|
|
int ret, i;
|
|
|
|
/* Only Titan Ridge of pre-USB4 devices support CLx states */
|
|
if (!tb_switch_is_titan_ridge(sw))
|
|
return 0;
|
|
|
|
if (!tb_route(sw))
|
|
return 0;
|
|
|
|
/*
|
|
* In Titan Ridge there are only 2 dual-lane Thunderbolt ports:
|
|
* Port A consists of lane adapters 1,2 and
|
|
* Port B consists of lane adapters 3,4
|
|
* If upstream port is A, (lanes are 1,2), we mask objections from
|
|
* port B (lanes 3,4) and unmask objections from Port A and vice-versa.
|
|
*/
|
|
if (up_port == 1) {
|
|
mask_obj = TB_LOW_PWR_C0_PORT_B_MASK;
|
|
unmask_obj = TB_LOW_PWR_C1_PORT_A_MASK;
|
|
offset = TB_LOW_PWR_C1_CL1;
|
|
} else {
|
|
mask_obj = TB_LOW_PWR_C1_PORT_A_MASK;
|
|
unmask_obj = TB_LOW_PWR_C0_PORT_B_MASK;
|
|
offset = TB_LOW_PWR_C3_CL1;
|
|
}
|
|
|
|
ret = tb_sw_read(sw, &val, TB_CFG_SWITCH,
|
|
sw->cap_lp + offset, ARRAY_SIZE(val));
|
|
if (ret)
|
|
return ret;
|
|
|
|
for (i = 0; i < ARRAY_SIZE(val); i++) {
|
|
val[i] |= mask_obj;
|
|
val[i] &= ~unmask_obj;
|
|
}
|
|
|
|
return tb_sw_write(sw, &val, TB_CFG_SWITCH,
|
|
sw->cap_lp + offset, ARRAY_SIZE(val));
|
|
}
|
|
|
|
/**
|
|
* tb_switch_clx_is_supported() - Is CLx supported on this type of router
|
|
* @sw: The router to check CLx support for
|
|
*/
|
|
bool tb_switch_clx_is_supported(const struct tb_switch *sw)
|
|
{
|
|
if (!clx_enabled)
|
|
return false;
|
|
|
|
if (sw->quirks & QUIRK_NO_CLX)
|
|
return false;
|
|
|
|
/*
|
|
* CLx is not enabled and validated on Intel USB4 platforms
|
|
* before Alder Lake.
|
|
*/
|
|
if (tb_switch_is_tiger_lake(sw))
|
|
return false;
|
|
|
|
return tb_switch_is_usb4(sw) || tb_switch_is_titan_ridge(sw);
|
|
}
|
|
|
|
static bool validate_mask(unsigned int clx)
|
|
{
|
|
/* Previous states need to be enabled */
|
|
if (clx & TB_CL1)
|
|
return (clx & TB_CL0S) == TB_CL0S;
|
|
return true;
|
|
}
|
|
|
|
/**
|
|
* tb_switch_clx_enable() - Enable CLx on upstream port of specified router
|
|
* @sw: Router to enable CLx for
|
|
* @clx: The CLx state to enable
|
|
*
|
|
* CLx is enabled only if both sides of the link support CLx, and if both sides
|
|
* of the link are not configured as two single lane links and only if the link
|
|
* is not inter-domain link. The complete set of conditions is described in CM
|
|
* Guide 1.0 section 8.1.
|
|
*
|
|
* Returns %0 on success or an error code on failure.
|
|
*/
|
|
int tb_switch_clx_enable(struct tb_switch *sw, unsigned int clx)
|
|
{
|
|
bool up_clx_support, down_clx_support;
|
|
struct tb_switch *parent_sw;
|
|
struct tb_port *up, *down;
|
|
int ret;
|
|
|
|
if (!clx || sw->clx == clx)
|
|
return 0;
|
|
|
|
if (!validate_mask(clx))
|
|
return -EINVAL;
|
|
|
|
parent_sw = tb_switch_parent(sw);
|
|
if (!parent_sw)
|
|
return 0;
|
|
|
|
if (!tb_switch_clx_is_supported(parent_sw) ||
|
|
!tb_switch_clx_is_supported(sw))
|
|
return 0;
|
|
|
|
/* Only support CL2 for v2 routers */
|
|
if ((clx & TB_CL2) &&
|
|
(usb4_switch_version(parent_sw) < 2 ||
|
|
usb4_switch_version(sw) < 2))
|
|
return -EOPNOTSUPP;
|
|
|
|
ret = tb_switch_pm_secondary_resolve(sw);
|
|
if (ret)
|
|
return ret;
|
|
|
|
up = tb_upstream_port(sw);
|
|
down = tb_switch_downstream_port(sw);
|
|
|
|
up_clx_support = tb_port_clx_supported(up, clx);
|
|
down_clx_support = tb_port_clx_supported(down, clx);
|
|
|
|
tb_port_dbg(up, "CLx: %s %ssupported\n", clx_name(clx),
|
|
up_clx_support ? "" : "not ");
|
|
tb_port_dbg(down, "CLx: %s %ssupported\n", clx_name(clx),
|
|
down_clx_support ? "" : "not ");
|
|
|
|
if (!up_clx_support || !down_clx_support)
|
|
return -EOPNOTSUPP;
|
|
|
|
ret = tb_port_clx_enable(up, clx);
|
|
if (ret)
|
|
return ret;
|
|
|
|
ret = tb_port_clx_enable(down, clx);
|
|
if (ret) {
|
|
tb_port_clx_disable(up, clx);
|
|
return ret;
|
|
}
|
|
|
|
ret = tb_switch_mask_clx_objections(sw);
|
|
if (ret) {
|
|
tb_port_clx_disable(up, clx);
|
|
tb_port_clx_disable(down, clx);
|
|
return ret;
|
|
}
|
|
|
|
sw->clx |= clx;
|
|
|
|
tb_sw_dbg(sw, "CLx: %s enabled\n", clx_name(clx));
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* tb_switch_clx_disable() - Disable CLx on upstream port of specified router
|
|
* @sw: Router to disable CLx for
|
|
*
|
|
* Disables all CL states of the given router. Can be called on any
|
|
* router and if the states were not enabled already does nothing.
|
|
*
|
|
* Returns the CL states that were disabled or negative errno in case of
|
|
* failure.
|
|
*/
|
|
int tb_switch_clx_disable(struct tb_switch *sw)
|
|
{
|
|
unsigned int clx = sw->clx;
|
|
struct tb_port *up, *down;
|
|
int ret;
|
|
|
|
if (!tb_switch_clx_is_supported(sw))
|
|
return 0;
|
|
|
|
if (!clx)
|
|
return 0;
|
|
|
|
up = tb_upstream_port(sw);
|
|
down = tb_switch_downstream_port(sw);
|
|
|
|
ret = tb_port_clx_disable(up, clx);
|
|
if (ret)
|
|
return ret;
|
|
|
|
ret = tb_port_clx_disable(down, clx);
|
|
if (ret)
|
|
return ret;
|
|
|
|
sw->clx = 0;
|
|
|
|
tb_sw_dbg(sw, "CLx: %s disabled\n", clx_name(clx));
|
|
return clx;
|
|
}
|