The trip crossing detection in handle_thermal_trip() does not work correctly in the cases when a trip point is crossed on the way up and then the zone temperature stays above its low temperature (that is, its temperature decreased by its hysteresis). The trip temperature may be passed by the zone temperature subsequently in that case, even multiple times, but that does not count as the trip crossing as long as the zone temperature does not fall below the trip's low temperature or, in other words, until the trip is crossed on the way down. |-----------low--------high------------| |<--------->| | hyst | | | | -|--> crossed on the way up | <---|-- crossed on the way down However, handle_thermal_trip() will invoke thermal_notify_tz_trip_up() every time the trip temperature is passed by the zone temperature on the way up regardless of whether or not the trip has been crossed on the way down yet. Moreover, it will not call thermal_notify_tz_trip_down() if the last zone temperature was between the trip's temperature and its low temperature, so some "trip crossed on the way down" events may not be reported. To address this issue, introduce trip thresholds equal to either the temperature of the given trip, or its low temperature, such that if the trip's threshold is passed by the zone temperature on the way up, its value will be set to the trip's low temperature and thermal_notify_tz_trip_up() will be called, and if the trip's threshold is passed by the zone temperature on the way down, its value will be set to the trip's temperature (high) and thermal_notify_tz_trip_down() will be called. Accordingly, if the threshold is passed on the way up, it cannot be passed on the way up again until its passed on the way down and if it is passed on the way down, it cannot be passed on the way down again until it is passed on the way up which guarantees correct triggering of trip crossing notifications. If the last temperature of the zone is invalid, the trip's threshold will be set depending of the zone's current temperature: If that temperature is above the trip's temperature, its threshold will be set to its low temperature or otherwise its threshold will be set to its (high) temperature. Because the zone temperature is initially set to invalid and tz->last_temperature is only updated by update_temperature(), this is sufficient to set the correct initial threshold values for all trips. Link: https://lore.kernel.org/all/20220718145038.1114379-4-daniel.lezcano@linaro.org Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
1614 lines
41 KiB
C
1614 lines
41 KiB
C
// SPDX-License-Identifier: GPL-2.0
|
|
/*
|
|
* thermal.c - Generic Thermal Management Sysfs support.
|
|
*
|
|
* Copyright (C) 2008 Intel Corp
|
|
* Copyright (C) 2008 Zhang Rui <rui.zhang@intel.com>
|
|
* Copyright (C) 2008 Sujith Thomas <sujith.thomas@intel.com>
|
|
*/
|
|
|
|
#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
|
|
|
|
#include <linux/device.h>
|
|
#include <linux/err.h>
|
|
#include <linux/export.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/kdev_t.h>
|
|
#include <linux/idr.h>
|
|
#include <linux/thermal.h>
|
|
#include <linux/reboot.h>
|
|
#include <linux/string.h>
|
|
#include <linux/of.h>
|
|
#include <linux/suspend.h>
|
|
|
|
#define CREATE_TRACE_POINTS
|
|
#include "thermal_trace.h"
|
|
|
|
#include "thermal_core.h"
|
|
#include "thermal_hwmon.h"
|
|
|
|
static DEFINE_IDA(thermal_tz_ida);
|
|
static DEFINE_IDA(thermal_cdev_ida);
|
|
|
|
static LIST_HEAD(thermal_tz_list);
|
|
static LIST_HEAD(thermal_cdev_list);
|
|
static LIST_HEAD(thermal_governor_list);
|
|
|
|
static DEFINE_MUTEX(thermal_list_lock);
|
|
static DEFINE_MUTEX(thermal_governor_lock);
|
|
|
|
static atomic_t in_suspend;
|
|
|
|
static struct thermal_governor *def_governor;
|
|
|
|
/*
|
|
* Governor section: set of functions to handle thermal governors
|
|
*
|
|
* Functions to help in the life cycle of thermal governors within
|
|
* the thermal core and by the thermal governor code.
|
|
*/
|
|
|
|
static struct thermal_governor *__find_governor(const char *name)
|
|
{
|
|
struct thermal_governor *pos;
|
|
|
|
if (!name || !name[0])
|
|
return def_governor;
|
|
|
|
list_for_each_entry(pos, &thermal_governor_list, governor_list)
|
|
if (!strncasecmp(name, pos->name, THERMAL_NAME_LENGTH))
|
|
return pos;
|
|
|
|
return NULL;
|
|
}
|
|
|
|
/**
|
|
* bind_previous_governor() - bind the previous governor of the thermal zone
|
|
* @tz: a valid pointer to a struct thermal_zone_device
|
|
* @failed_gov_name: the name of the governor that failed to register
|
|
*
|
|
* Register the previous governor of the thermal zone after a new
|
|
* governor has failed to be bound.
|
|
*/
|
|
static void bind_previous_governor(struct thermal_zone_device *tz,
|
|
const char *failed_gov_name)
|
|
{
|
|
if (tz->governor && tz->governor->bind_to_tz) {
|
|
if (tz->governor->bind_to_tz(tz)) {
|
|
dev_err(&tz->device,
|
|
"governor %s failed to bind and the previous one (%s) failed to bind again, thermal zone %s has no governor\n",
|
|
failed_gov_name, tz->governor->name, tz->type);
|
|
tz->governor = NULL;
|
|
}
|
|
}
|
|
}
|
|
|
|
/**
|
|
* thermal_set_governor() - Switch to another governor
|
|
* @tz: a valid pointer to a struct thermal_zone_device
|
|
* @new_gov: pointer to the new governor
|
|
*
|
|
* Change the governor of thermal zone @tz.
|
|
*
|
|
* Return: 0 on success, an error if the new governor's bind_to_tz() failed.
|
|
*/
|
|
static int thermal_set_governor(struct thermal_zone_device *tz,
|
|
struct thermal_governor *new_gov)
|
|
{
|
|
int ret = 0;
|
|
|
|
if (tz->governor && tz->governor->unbind_from_tz)
|
|
tz->governor->unbind_from_tz(tz);
|
|
|
|
if (new_gov && new_gov->bind_to_tz) {
|
|
ret = new_gov->bind_to_tz(tz);
|
|
if (ret) {
|
|
bind_previous_governor(tz, new_gov->name);
|
|
|
|
return ret;
|
|
}
|
|
}
|
|
|
|
tz->governor = new_gov;
|
|
|
|
return ret;
|
|
}
|
|
|
|
int thermal_register_governor(struct thermal_governor *governor)
|
|
{
|
|
int err;
|
|
const char *name;
|
|
struct thermal_zone_device *pos;
|
|
|
|
if (!governor)
|
|
return -EINVAL;
|
|
|
|
mutex_lock(&thermal_governor_lock);
|
|
|
|
err = -EBUSY;
|
|
if (!__find_governor(governor->name)) {
|
|
bool match_default;
|
|
|
|
err = 0;
|
|
list_add(&governor->governor_list, &thermal_governor_list);
|
|
match_default = !strncmp(governor->name,
|
|
DEFAULT_THERMAL_GOVERNOR,
|
|
THERMAL_NAME_LENGTH);
|
|
|
|
if (!def_governor && match_default)
|
|
def_governor = governor;
|
|
}
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
|
|
list_for_each_entry(pos, &thermal_tz_list, node) {
|
|
/*
|
|
* only thermal zones with specified tz->tzp->governor_name
|
|
* may run with tz->govenor unset
|
|
*/
|
|
if (pos->governor)
|
|
continue;
|
|
|
|
name = pos->tzp->governor_name;
|
|
|
|
if (!strncasecmp(name, governor->name, THERMAL_NAME_LENGTH)) {
|
|
int ret;
|
|
|
|
ret = thermal_set_governor(pos, governor);
|
|
if (ret)
|
|
dev_err(&pos->device,
|
|
"Failed to set governor %s for thermal zone %s: %d\n",
|
|
governor->name, pos->type, ret);
|
|
}
|
|
}
|
|
|
|
mutex_unlock(&thermal_list_lock);
|
|
mutex_unlock(&thermal_governor_lock);
|
|
|
|
return err;
|
|
}
|
|
|
|
void thermal_unregister_governor(struct thermal_governor *governor)
|
|
{
|
|
struct thermal_zone_device *pos;
|
|
|
|
if (!governor)
|
|
return;
|
|
|
|
mutex_lock(&thermal_governor_lock);
|
|
|
|
if (!__find_governor(governor->name))
|
|
goto exit;
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
|
|
list_for_each_entry(pos, &thermal_tz_list, node) {
|
|
if (!strncasecmp(pos->governor->name, governor->name,
|
|
THERMAL_NAME_LENGTH))
|
|
thermal_set_governor(pos, NULL);
|
|
}
|
|
|
|
mutex_unlock(&thermal_list_lock);
|
|
list_del(&governor->governor_list);
|
|
exit:
|
|
mutex_unlock(&thermal_governor_lock);
|
|
}
|
|
|
|
int thermal_zone_device_set_policy(struct thermal_zone_device *tz,
|
|
char *policy)
|
|
{
|
|
struct thermal_governor *gov;
|
|
int ret = -EINVAL;
|
|
|
|
mutex_lock(&thermal_governor_lock);
|
|
mutex_lock(&tz->lock);
|
|
|
|
if (!device_is_registered(&tz->device))
|
|
goto exit;
|
|
|
|
gov = __find_governor(strim(policy));
|
|
if (!gov)
|
|
goto exit;
|
|
|
|
ret = thermal_set_governor(tz, gov);
|
|
|
|
exit:
|
|
mutex_unlock(&tz->lock);
|
|
mutex_unlock(&thermal_governor_lock);
|
|
|
|
thermal_notify_tz_gov_change(tz->id, policy);
|
|
|
|
return ret;
|
|
}
|
|
|
|
int thermal_build_list_of_policies(char *buf)
|
|
{
|
|
struct thermal_governor *pos;
|
|
ssize_t count = 0;
|
|
|
|
mutex_lock(&thermal_governor_lock);
|
|
|
|
list_for_each_entry(pos, &thermal_governor_list, governor_list) {
|
|
count += sysfs_emit_at(buf, count, "%s ", pos->name);
|
|
}
|
|
count += sysfs_emit_at(buf, count, "\n");
|
|
|
|
mutex_unlock(&thermal_governor_lock);
|
|
|
|
return count;
|
|
}
|
|
|
|
static void __init thermal_unregister_governors(void)
|
|
{
|
|
struct thermal_governor **governor;
|
|
|
|
for_each_governor_table(governor)
|
|
thermal_unregister_governor(*governor);
|
|
}
|
|
|
|
static int __init thermal_register_governors(void)
|
|
{
|
|
int ret = 0;
|
|
struct thermal_governor **governor;
|
|
|
|
for_each_governor_table(governor) {
|
|
ret = thermal_register_governor(*governor);
|
|
if (ret) {
|
|
pr_err("Failed to register governor: '%s'",
|
|
(*governor)->name);
|
|
break;
|
|
}
|
|
|
|
pr_info("Registered thermal governor '%s'",
|
|
(*governor)->name);
|
|
}
|
|
|
|
if (ret) {
|
|
struct thermal_governor **gov;
|
|
|
|
for_each_governor_table(gov) {
|
|
if (gov == governor)
|
|
break;
|
|
thermal_unregister_governor(*gov);
|
|
}
|
|
}
|
|
|
|
return ret;
|
|
}
|
|
|
|
/*
|
|
* Zone update section: main control loop applied to each zone while monitoring
|
|
*
|
|
* in polling mode. The monitoring is done using a workqueue.
|
|
* Same update may be done on a zone by calling thermal_zone_device_update().
|
|
*
|
|
* An update means:
|
|
* - Non-critical trips will invoke the governor responsible for that zone;
|
|
* - Hot trips will produce a notification to userspace;
|
|
* - Critical trip point will cause a system shutdown.
|
|
*/
|
|
static void thermal_zone_device_set_polling(struct thermal_zone_device *tz,
|
|
unsigned long delay)
|
|
{
|
|
if (delay)
|
|
mod_delayed_work(system_freezable_power_efficient_wq,
|
|
&tz->poll_queue, delay);
|
|
else
|
|
cancel_delayed_work(&tz->poll_queue);
|
|
}
|
|
|
|
static void monitor_thermal_zone(struct thermal_zone_device *tz)
|
|
{
|
|
if (tz->mode != THERMAL_DEVICE_ENABLED)
|
|
thermal_zone_device_set_polling(tz, 0);
|
|
else if (tz->passive)
|
|
thermal_zone_device_set_polling(tz, tz->passive_delay_jiffies);
|
|
else if (tz->polling_delay_jiffies)
|
|
thermal_zone_device_set_polling(tz, tz->polling_delay_jiffies);
|
|
}
|
|
|
|
static void handle_non_critical_trips(struct thermal_zone_device *tz,
|
|
const struct thermal_trip *trip)
|
|
{
|
|
tz->governor ? tz->governor->throttle(tz, trip) :
|
|
def_governor->throttle(tz, trip);
|
|
}
|
|
|
|
void thermal_zone_device_critical(struct thermal_zone_device *tz)
|
|
{
|
|
/*
|
|
* poweroff_delay_ms must be a carefully profiled positive value.
|
|
* Its a must for forced_emergency_poweroff_work to be scheduled.
|
|
*/
|
|
int poweroff_delay_ms = CONFIG_THERMAL_EMERGENCY_POWEROFF_DELAY_MS;
|
|
|
|
dev_emerg(&tz->device, "%s: critical temperature reached, "
|
|
"shutting down\n", tz->type);
|
|
|
|
hw_protection_shutdown("Temperature too high", poweroff_delay_ms);
|
|
}
|
|
EXPORT_SYMBOL(thermal_zone_device_critical);
|
|
|
|
static void handle_critical_trips(struct thermal_zone_device *tz,
|
|
const struct thermal_trip *trip)
|
|
{
|
|
/* If we have not crossed the trip_temp, we do not care. */
|
|
if (trip->temperature <= 0 || tz->temperature < trip->temperature)
|
|
return;
|
|
|
|
trace_thermal_zone_trip(tz, thermal_zone_trip_id(tz, trip), trip->type);
|
|
|
|
if (trip->type == THERMAL_TRIP_CRITICAL)
|
|
tz->ops->critical(tz);
|
|
else if (tz->ops->hot)
|
|
tz->ops->hot(tz);
|
|
}
|
|
|
|
static void handle_thermal_trip(struct thermal_zone_device *tz,
|
|
struct thermal_trip *trip)
|
|
{
|
|
if (trip->temperature == THERMAL_TEMP_INVALID)
|
|
return;
|
|
|
|
if (tz->last_temperature == THERMAL_TEMP_INVALID) {
|
|
/* Initialization. */
|
|
trip->threshold = trip->temperature;
|
|
if (tz->temperature >= trip->threshold)
|
|
trip->threshold -= trip->hysteresis;
|
|
} else if (tz->last_temperature < trip->threshold) {
|
|
/*
|
|
* The trip threshold is equal to the trip temperature, unless
|
|
* the latter has changed in the meantime. In either case,
|
|
* the trip is crossed if the current zone temperature is at
|
|
* least equal to its temperature, but otherwise ensure that
|
|
* the threshold and the trip temperature will be equal.
|
|
*/
|
|
if (tz->temperature >= trip->temperature) {
|
|
thermal_notify_tz_trip_up(tz->id,
|
|
thermal_zone_trip_id(tz, trip),
|
|
tz->temperature);
|
|
trip->threshold = trip->temperature - trip->hysteresis;
|
|
} else {
|
|
trip->threshold = trip->temperature;
|
|
}
|
|
} else {
|
|
/*
|
|
* The previous zone temperature was above or equal to the trip
|
|
* threshold, which would be equal to the "low temperature" of
|
|
* the trip (its temperature minus its hysteresis), unless the
|
|
* trip temperature or hysteresis had changed. In either case,
|
|
* the trip is crossed if the current zone temperature is below
|
|
* the low temperature of the trip, but otherwise ensure that
|
|
* the trip threshold will be equal to the low temperature of
|
|
* the trip.
|
|
*/
|
|
if (tz->temperature < trip->temperature - trip->hysteresis) {
|
|
thermal_notify_tz_trip_down(tz->id,
|
|
thermal_zone_trip_id(tz, trip),
|
|
tz->temperature);
|
|
trip->threshold = trip->temperature;
|
|
} else {
|
|
trip->threshold = trip->temperature - trip->hysteresis;
|
|
}
|
|
}
|
|
|
|
if (trip->type == THERMAL_TRIP_CRITICAL || trip->type == THERMAL_TRIP_HOT)
|
|
handle_critical_trips(tz, trip);
|
|
else
|
|
handle_non_critical_trips(tz, trip);
|
|
}
|
|
|
|
static void update_temperature(struct thermal_zone_device *tz)
|
|
{
|
|
int temp, ret;
|
|
|
|
ret = __thermal_zone_get_temp(tz, &temp);
|
|
if (ret) {
|
|
if (ret != -EAGAIN)
|
|
dev_warn(&tz->device,
|
|
"failed to read out thermal zone (%d)\n",
|
|
ret);
|
|
return;
|
|
}
|
|
|
|
tz->last_temperature = tz->temperature;
|
|
tz->temperature = temp;
|
|
|
|
trace_thermal_temperature(tz);
|
|
|
|
thermal_genl_sampling_temp(tz->id, temp);
|
|
}
|
|
|
|
static void thermal_zone_device_init(struct thermal_zone_device *tz)
|
|
{
|
|
struct thermal_instance *pos;
|
|
tz->temperature = THERMAL_TEMP_INVALID;
|
|
tz->prev_low_trip = -INT_MAX;
|
|
tz->prev_high_trip = INT_MAX;
|
|
list_for_each_entry(pos, &tz->thermal_instances, tz_node)
|
|
pos->initialized = false;
|
|
}
|
|
|
|
void __thermal_zone_device_update(struct thermal_zone_device *tz,
|
|
enum thermal_notify_event event)
|
|
{
|
|
struct thermal_trip *trip;
|
|
|
|
if (atomic_read(&in_suspend))
|
|
return;
|
|
|
|
if (WARN_ONCE(!tz->ops->get_temp,
|
|
"'%s' must not be called without 'get_temp' ops set\n",
|
|
__func__))
|
|
return;
|
|
|
|
if (!thermal_zone_device_is_enabled(tz))
|
|
return;
|
|
|
|
update_temperature(tz);
|
|
|
|
__thermal_zone_set_trips(tz);
|
|
|
|
tz->notify_event = event;
|
|
|
|
for_each_trip(tz, trip)
|
|
handle_thermal_trip(tz, trip);
|
|
|
|
monitor_thermal_zone(tz);
|
|
}
|
|
|
|
static int thermal_zone_device_set_mode(struct thermal_zone_device *tz,
|
|
enum thermal_device_mode mode)
|
|
{
|
|
int ret = 0;
|
|
|
|
mutex_lock(&tz->lock);
|
|
|
|
/* do nothing if mode isn't changing */
|
|
if (mode == tz->mode) {
|
|
mutex_unlock(&tz->lock);
|
|
|
|
return ret;
|
|
}
|
|
|
|
if (!device_is_registered(&tz->device)) {
|
|
mutex_unlock(&tz->lock);
|
|
|
|
return -ENODEV;
|
|
}
|
|
|
|
if (tz->ops->change_mode)
|
|
ret = tz->ops->change_mode(tz, mode);
|
|
|
|
if (!ret)
|
|
tz->mode = mode;
|
|
|
|
__thermal_zone_device_update(tz, THERMAL_EVENT_UNSPECIFIED);
|
|
|
|
mutex_unlock(&tz->lock);
|
|
|
|
if (mode == THERMAL_DEVICE_ENABLED)
|
|
thermal_notify_tz_enable(tz->id);
|
|
else
|
|
thermal_notify_tz_disable(tz->id);
|
|
|
|
return ret;
|
|
}
|
|
|
|
int thermal_zone_device_enable(struct thermal_zone_device *tz)
|
|
{
|
|
return thermal_zone_device_set_mode(tz, THERMAL_DEVICE_ENABLED);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_device_enable);
|
|
|
|
int thermal_zone_device_disable(struct thermal_zone_device *tz)
|
|
{
|
|
return thermal_zone_device_set_mode(tz, THERMAL_DEVICE_DISABLED);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_device_disable);
|
|
|
|
int thermal_zone_device_is_enabled(struct thermal_zone_device *tz)
|
|
{
|
|
lockdep_assert_held(&tz->lock);
|
|
|
|
return tz->mode == THERMAL_DEVICE_ENABLED;
|
|
}
|
|
|
|
void thermal_zone_device_update(struct thermal_zone_device *tz,
|
|
enum thermal_notify_event event)
|
|
{
|
|
mutex_lock(&tz->lock);
|
|
if (device_is_registered(&tz->device))
|
|
__thermal_zone_device_update(tz, event);
|
|
mutex_unlock(&tz->lock);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_device_update);
|
|
|
|
static void thermal_zone_device_check(struct work_struct *work)
|
|
{
|
|
struct thermal_zone_device *tz = container_of(work, struct
|
|
thermal_zone_device,
|
|
poll_queue.work);
|
|
thermal_zone_device_update(tz, THERMAL_EVENT_UNSPECIFIED);
|
|
}
|
|
|
|
int for_each_thermal_governor(int (*cb)(struct thermal_governor *, void *),
|
|
void *data)
|
|
{
|
|
struct thermal_governor *gov;
|
|
int ret = 0;
|
|
|
|
mutex_lock(&thermal_governor_lock);
|
|
list_for_each_entry(gov, &thermal_governor_list, governor_list) {
|
|
ret = cb(gov, data);
|
|
if (ret)
|
|
break;
|
|
}
|
|
mutex_unlock(&thermal_governor_lock);
|
|
|
|
return ret;
|
|
}
|
|
|
|
int for_each_thermal_cooling_device(int (*cb)(struct thermal_cooling_device *,
|
|
void *), void *data)
|
|
{
|
|
struct thermal_cooling_device *cdev;
|
|
int ret = 0;
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
list_for_each_entry(cdev, &thermal_cdev_list, node) {
|
|
ret = cb(cdev, data);
|
|
if (ret)
|
|
break;
|
|
}
|
|
mutex_unlock(&thermal_list_lock);
|
|
|
|
return ret;
|
|
}
|
|
|
|
int for_each_thermal_zone(int (*cb)(struct thermal_zone_device *, void *),
|
|
void *data)
|
|
{
|
|
struct thermal_zone_device *tz;
|
|
int ret = 0;
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
list_for_each_entry(tz, &thermal_tz_list, node) {
|
|
ret = cb(tz, data);
|
|
if (ret)
|
|
break;
|
|
}
|
|
mutex_unlock(&thermal_list_lock);
|
|
|
|
return ret;
|
|
}
|
|
|
|
struct thermal_zone_device *thermal_zone_get_by_id(int id)
|
|
{
|
|
struct thermal_zone_device *tz, *match = NULL;
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
list_for_each_entry(tz, &thermal_tz_list, node) {
|
|
if (tz->id == id) {
|
|
match = tz;
|
|
break;
|
|
}
|
|
}
|
|
mutex_unlock(&thermal_list_lock);
|
|
|
|
return match;
|
|
}
|
|
|
|
/*
|
|
* Device management section: cooling devices, zones devices, and binding
|
|
*
|
|
* Set of functions provided by the thermal core for:
|
|
* - cooling devices lifecycle: registration, unregistration,
|
|
* binding, and unbinding.
|
|
* - thermal zone devices lifecycle: registration, unregistration,
|
|
* binding, and unbinding.
|
|
*/
|
|
|
|
/**
|
|
* thermal_bind_cdev_to_trip - bind a cooling device to a thermal zone
|
|
* @tz: pointer to struct thermal_zone_device
|
|
* @trip: trip point the cooling devices is associated with in this zone.
|
|
* @cdev: pointer to struct thermal_cooling_device
|
|
* @upper: the Maximum cooling state for this trip point.
|
|
* THERMAL_NO_LIMIT means no upper limit,
|
|
* and the cooling device can be in max_state.
|
|
* @lower: the Minimum cooling state can be used for this trip point.
|
|
* THERMAL_NO_LIMIT means no lower limit,
|
|
* and the cooling device can be in cooling state 0.
|
|
* @weight: The weight of the cooling device to be bound to the
|
|
* thermal zone. Use THERMAL_WEIGHT_DEFAULT for the
|
|
* default value
|
|
*
|
|
* This interface function bind a thermal cooling device to the certain trip
|
|
* point of a thermal zone device.
|
|
* This function is usually called in the thermal zone device .bind callback.
|
|
*
|
|
* Return: 0 on success, the proper error value otherwise.
|
|
*/
|
|
int thermal_bind_cdev_to_trip(struct thermal_zone_device *tz,
|
|
const struct thermal_trip *trip,
|
|
struct thermal_cooling_device *cdev,
|
|
unsigned long upper, unsigned long lower,
|
|
unsigned int weight)
|
|
{
|
|
struct thermal_instance *dev;
|
|
struct thermal_instance *pos;
|
|
struct thermal_zone_device *pos1;
|
|
struct thermal_cooling_device *pos2;
|
|
bool upper_no_limit;
|
|
int result;
|
|
|
|
list_for_each_entry(pos1, &thermal_tz_list, node) {
|
|
if (pos1 == tz)
|
|
break;
|
|
}
|
|
list_for_each_entry(pos2, &thermal_cdev_list, node) {
|
|
if (pos2 == cdev)
|
|
break;
|
|
}
|
|
|
|
if (tz != pos1 || cdev != pos2)
|
|
return -EINVAL;
|
|
|
|
/* lower default 0, upper default max_state */
|
|
lower = lower == THERMAL_NO_LIMIT ? 0 : lower;
|
|
|
|
if (upper == THERMAL_NO_LIMIT) {
|
|
upper = cdev->max_state;
|
|
upper_no_limit = true;
|
|
} else {
|
|
upper_no_limit = false;
|
|
}
|
|
|
|
if (lower > upper || upper > cdev->max_state)
|
|
return -EINVAL;
|
|
|
|
dev = kzalloc(sizeof(*dev), GFP_KERNEL);
|
|
if (!dev)
|
|
return -ENOMEM;
|
|
dev->tz = tz;
|
|
dev->cdev = cdev;
|
|
dev->trip = trip;
|
|
dev->upper = upper;
|
|
dev->upper_no_limit = upper_no_limit;
|
|
dev->lower = lower;
|
|
dev->target = THERMAL_NO_TARGET;
|
|
dev->weight = weight;
|
|
|
|
result = ida_alloc(&tz->ida, GFP_KERNEL);
|
|
if (result < 0)
|
|
goto free_mem;
|
|
|
|
dev->id = result;
|
|
sprintf(dev->name, "cdev%d", dev->id);
|
|
result =
|
|
sysfs_create_link(&tz->device.kobj, &cdev->device.kobj, dev->name);
|
|
if (result)
|
|
goto release_ida;
|
|
|
|
snprintf(dev->attr_name, sizeof(dev->attr_name), "cdev%d_trip_point",
|
|
dev->id);
|
|
sysfs_attr_init(&dev->attr.attr);
|
|
dev->attr.attr.name = dev->attr_name;
|
|
dev->attr.attr.mode = 0444;
|
|
dev->attr.show = trip_point_show;
|
|
result = device_create_file(&tz->device, &dev->attr);
|
|
if (result)
|
|
goto remove_symbol_link;
|
|
|
|
snprintf(dev->weight_attr_name, sizeof(dev->weight_attr_name),
|
|
"cdev%d_weight", dev->id);
|
|
sysfs_attr_init(&dev->weight_attr.attr);
|
|
dev->weight_attr.attr.name = dev->weight_attr_name;
|
|
dev->weight_attr.attr.mode = S_IWUSR | S_IRUGO;
|
|
dev->weight_attr.show = weight_show;
|
|
dev->weight_attr.store = weight_store;
|
|
result = device_create_file(&tz->device, &dev->weight_attr);
|
|
if (result)
|
|
goto remove_trip_file;
|
|
|
|
mutex_lock(&tz->lock);
|
|
mutex_lock(&cdev->lock);
|
|
list_for_each_entry(pos, &tz->thermal_instances, tz_node)
|
|
if (pos->tz == tz && pos->trip == trip && pos->cdev == cdev) {
|
|
result = -EEXIST;
|
|
break;
|
|
}
|
|
if (!result) {
|
|
list_add_tail(&dev->tz_node, &tz->thermal_instances);
|
|
list_add_tail(&dev->cdev_node, &cdev->thermal_instances);
|
|
atomic_set(&tz->need_update, 1);
|
|
}
|
|
mutex_unlock(&cdev->lock);
|
|
mutex_unlock(&tz->lock);
|
|
|
|
if (!result)
|
|
return 0;
|
|
|
|
device_remove_file(&tz->device, &dev->weight_attr);
|
|
remove_trip_file:
|
|
device_remove_file(&tz->device, &dev->attr);
|
|
remove_symbol_link:
|
|
sysfs_remove_link(&tz->device.kobj, dev->name);
|
|
release_ida:
|
|
ida_free(&tz->ida, dev->id);
|
|
free_mem:
|
|
kfree(dev);
|
|
return result;
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_bind_cdev_to_trip);
|
|
|
|
int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
|
|
int trip_index,
|
|
struct thermal_cooling_device *cdev,
|
|
unsigned long upper, unsigned long lower,
|
|
unsigned int weight)
|
|
{
|
|
if (trip_index < 0 || trip_index >= tz->num_trips)
|
|
return -EINVAL;
|
|
|
|
return thermal_bind_cdev_to_trip(tz, &tz->trips[trip_index], cdev,
|
|
upper, lower, weight);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_bind_cooling_device);
|
|
|
|
/**
|
|
* thermal_unbind_cdev_from_trip - unbind a cooling device from a thermal zone.
|
|
* @tz: pointer to a struct thermal_zone_device.
|
|
* @trip: trip point the cooling devices is associated with in this zone.
|
|
* @cdev: pointer to a struct thermal_cooling_device.
|
|
*
|
|
* This interface function unbind a thermal cooling device from the certain
|
|
* trip point of a thermal zone device.
|
|
* This function is usually called in the thermal zone device .unbind callback.
|
|
*
|
|
* Return: 0 on success, the proper error value otherwise.
|
|
*/
|
|
int thermal_unbind_cdev_from_trip(struct thermal_zone_device *tz,
|
|
const struct thermal_trip *trip,
|
|
struct thermal_cooling_device *cdev)
|
|
{
|
|
struct thermal_instance *pos, *next;
|
|
|
|
mutex_lock(&tz->lock);
|
|
mutex_lock(&cdev->lock);
|
|
list_for_each_entry_safe(pos, next, &tz->thermal_instances, tz_node) {
|
|
if (pos->tz == tz && pos->trip == trip && pos->cdev == cdev) {
|
|
list_del(&pos->tz_node);
|
|
list_del(&pos->cdev_node);
|
|
mutex_unlock(&cdev->lock);
|
|
mutex_unlock(&tz->lock);
|
|
goto unbind;
|
|
}
|
|
}
|
|
mutex_unlock(&cdev->lock);
|
|
mutex_unlock(&tz->lock);
|
|
|
|
return -ENODEV;
|
|
|
|
unbind:
|
|
device_remove_file(&tz->device, &pos->weight_attr);
|
|
device_remove_file(&tz->device, &pos->attr);
|
|
sysfs_remove_link(&tz->device.kobj, pos->name);
|
|
ida_free(&tz->ida, pos->id);
|
|
kfree(pos);
|
|
return 0;
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_unbind_cdev_from_trip);
|
|
|
|
int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
|
|
int trip_index,
|
|
struct thermal_cooling_device *cdev)
|
|
{
|
|
if (trip_index < 0 || trip_index >= tz->num_trips)
|
|
return -EINVAL;
|
|
|
|
return thermal_unbind_cdev_from_trip(tz, &tz->trips[trip_index], cdev);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_unbind_cooling_device);
|
|
|
|
static void thermal_release(struct device *dev)
|
|
{
|
|
struct thermal_zone_device *tz;
|
|
struct thermal_cooling_device *cdev;
|
|
|
|
if (!strncmp(dev_name(dev), "thermal_zone",
|
|
sizeof("thermal_zone") - 1)) {
|
|
tz = to_thermal_zone(dev);
|
|
thermal_zone_destroy_device_groups(tz);
|
|
mutex_destroy(&tz->lock);
|
|
kfree(tz);
|
|
} else if (!strncmp(dev_name(dev), "cooling_device",
|
|
sizeof("cooling_device") - 1)) {
|
|
cdev = to_cooling_device(dev);
|
|
thermal_cooling_device_destroy_sysfs(cdev);
|
|
kfree(cdev->type);
|
|
ida_free(&thermal_cdev_ida, cdev->id);
|
|
kfree(cdev);
|
|
}
|
|
}
|
|
|
|
static struct class *thermal_class;
|
|
|
|
static inline
|
|
void print_bind_err_msg(struct thermal_zone_device *tz,
|
|
struct thermal_cooling_device *cdev, int ret)
|
|
{
|
|
dev_err(&tz->device, "binding zone %s with cdev %s failed:%d\n",
|
|
tz->type, cdev->type, ret);
|
|
}
|
|
|
|
static void bind_cdev(struct thermal_cooling_device *cdev)
|
|
{
|
|
int ret;
|
|
struct thermal_zone_device *pos = NULL;
|
|
|
|
list_for_each_entry(pos, &thermal_tz_list, node) {
|
|
if (pos->ops->bind) {
|
|
ret = pos->ops->bind(pos, cdev);
|
|
if (ret)
|
|
print_bind_err_msg(pos, cdev, ret);
|
|
}
|
|
}
|
|
}
|
|
|
|
/**
|
|
* __thermal_cooling_device_register() - register a new thermal cooling device
|
|
* @np: a pointer to a device tree node.
|
|
* @type: the thermal cooling device type.
|
|
* @devdata: device private data.
|
|
* @ops: standard thermal cooling devices callbacks.
|
|
*
|
|
* This interface function adds a new thermal cooling device (fan/processor/...)
|
|
* to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
|
|
* to all the thermal zone devices registered at the same time.
|
|
* It also gives the opportunity to link the cooling device to a device tree
|
|
* node, so that it can be bound to a thermal zone created out of device tree.
|
|
*
|
|
* Return: a pointer to the created struct thermal_cooling_device or an
|
|
* ERR_PTR. Caller must check return value with IS_ERR*() helpers.
|
|
*/
|
|
static struct thermal_cooling_device *
|
|
__thermal_cooling_device_register(struct device_node *np,
|
|
const char *type, void *devdata,
|
|
const struct thermal_cooling_device_ops *ops)
|
|
{
|
|
struct thermal_cooling_device *cdev;
|
|
struct thermal_zone_device *pos = NULL;
|
|
int id, ret;
|
|
|
|
if (!ops || !ops->get_max_state || !ops->get_cur_state ||
|
|
!ops->set_cur_state)
|
|
return ERR_PTR(-EINVAL);
|
|
|
|
if (!thermal_class)
|
|
return ERR_PTR(-ENODEV);
|
|
|
|
cdev = kzalloc(sizeof(*cdev), GFP_KERNEL);
|
|
if (!cdev)
|
|
return ERR_PTR(-ENOMEM);
|
|
|
|
ret = ida_alloc(&thermal_cdev_ida, GFP_KERNEL);
|
|
if (ret < 0)
|
|
goto out_kfree_cdev;
|
|
cdev->id = ret;
|
|
id = ret;
|
|
|
|
cdev->type = kstrdup(type ? type : "", GFP_KERNEL);
|
|
if (!cdev->type) {
|
|
ret = -ENOMEM;
|
|
goto out_ida_remove;
|
|
}
|
|
|
|
mutex_init(&cdev->lock);
|
|
INIT_LIST_HEAD(&cdev->thermal_instances);
|
|
cdev->np = np;
|
|
cdev->ops = ops;
|
|
cdev->updated = false;
|
|
cdev->device.class = thermal_class;
|
|
cdev->devdata = devdata;
|
|
|
|
ret = cdev->ops->get_max_state(cdev, &cdev->max_state);
|
|
if (ret)
|
|
goto out_cdev_type;
|
|
|
|
thermal_cooling_device_setup_sysfs(cdev);
|
|
|
|
ret = dev_set_name(&cdev->device, "cooling_device%d", cdev->id);
|
|
if (ret)
|
|
goto out_cooling_dev;
|
|
|
|
ret = device_register(&cdev->device);
|
|
if (ret) {
|
|
/* thermal_release() handles rest of the cleanup */
|
|
put_device(&cdev->device);
|
|
return ERR_PTR(ret);
|
|
}
|
|
|
|
/* Add 'this' new cdev to the global cdev list */
|
|
mutex_lock(&thermal_list_lock);
|
|
|
|
list_add(&cdev->node, &thermal_cdev_list);
|
|
|
|
/* Update binding information for 'this' new cdev */
|
|
bind_cdev(cdev);
|
|
|
|
list_for_each_entry(pos, &thermal_tz_list, node)
|
|
if (atomic_cmpxchg(&pos->need_update, 1, 0))
|
|
thermal_zone_device_update(pos,
|
|
THERMAL_EVENT_UNSPECIFIED);
|
|
|
|
mutex_unlock(&thermal_list_lock);
|
|
|
|
return cdev;
|
|
|
|
out_cooling_dev:
|
|
thermal_cooling_device_destroy_sysfs(cdev);
|
|
out_cdev_type:
|
|
kfree(cdev->type);
|
|
out_ida_remove:
|
|
ida_free(&thermal_cdev_ida, id);
|
|
out_kfree_cdev:
|
|
kfree(cdev);
|
|
return ERR_PTR(ret);
|
|
}
|
|
|
|
/**
|
|
* thermal_cooling_device_register() - register a new thermal cooling device
|
|
* @type: the thermal cooling device type.
|
|
* @devdata: device private data.
|
|
* @ops: standard thermal cooling devices callbacks.
|
|
*
|
|
* This interface function adds a new thermal cooling device (fan/processor/...)
|
|
* to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
|
|
* to all the thermal zone devices registered at the same time.
|
|
*
|
|
* Return: a pointer to the created struct thermal_cooling_device or an
|
|
* ERR_PTR. Caller must check return value with IS_ERR*() helpers.
|
|
*/
|
|
struct thermal_cooling_device *
|
|
thermal_cooling_device_register(const char *type, void *devdata,
|
|
const struct thermal_cooling_device_ops *ops)
|
|
{
|
|
return __thermal_cooling_device_register(NULL, type, devdata, ops);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_cooling_device_register);
|
|
|
|
/**
|
|
* thermal_of_cooling_device_register() - register an OF thermal cooling device
|
|
* @np: a pointer to a device tree node.
|
|
* @type: the thermal cooling device type.
|
|
* @devdata: device private data.
|
|
* @ops: standard thermal cooling devices callbacks.
|
|
*
|
|
* This function will register a cooling device with device tree node reference.
|
|
* This interface function adds a new thermal cooling device (fan/processor/...)
|
|
* to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
|
|
* to all the thermal zone devices registered at the same time.
|
|
*
|
|
* Return: a pointer to the created struct thermal_cooling_device or an
|
|
* ERR_PTR. Caller must check return value with IS_ERR*() helpers.
|
|
*/
|
|
struct thermal_cooling_device *
|
|
thermal_of_cooling_device_register(struct device_node *np,
|
|
const char *type, void *devdata,
|
|
const struct thermal_cooling_device_ops *ops)
|
|
{
|
|
return __thermal_cooling_device_register(np, type, devdata, ops);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_of_cooling_device_register);
|
|
|
|
static void thermal_cooling_device_release(struct device *dev, void *res)
|
|
{
|
|
thermal_cooling_device_unregister(
|
|
*(struct thermal_cooling_device **)res);
|
|
}
|
|
|
|
/**
|
|
* devm_thermal_of_cooling_device_register() - register an OF thermal cooling
|
|
* device
|
|
* @dev: a valid struct device pointer of a sensor device.
|
|
* @np: a pointer to a device tree node.
|
|
* @type: the thermal cooling device type.
|
|
* @devdata: device private data.
|
|
* @ops: standard thermal cooling devices callbacks.
|
|
*
|
|
* This function will register a cooling device with device tree node reference.
|
|
* This interface function adds a new thermal cooling device (fan/processor/...)
|
|
* to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
|
|
* to all the thermal zone devices registered at the same time.
|
|
*
|
|
* Return: a pointer to the created struct thermal_cooling_device or an
|
|
* ERR_PTR. Caller must check return value with IS_ERR*() helpers.
|
|
*/
|
|
struct thermal_cooling_device *
|
|
devm_thermal_of_cooling_device_register(struct device *dev,
|
|
struct device_node *np,
|
|
char *type, void *devdata,
|
|
const struct thermal_cooling_device_ops *ops)
|
|
{
|
|
struct thermal_cooling_device **ptr, *tcd;
|
|
|
|
ptr = devres_alloc(thermal_cooling_device_release, sizeof(*ptr),
|
|
GFP_KERNEL);
|
|
if (!ptr)
|
|
return ERR_PTR(-ENOMEM);
|
|
|
|
tcd = __thermal_cooling_device_register(np, type, devdata, ops);
|
|
if (IS_ERR(tcd)) {
|
|
devres_free(ptr);
|
|
return tcd;
|
|
}
|
|
|
|
*ptr = tcd;
|
|
devres_add(dev, ptr);
|
|
|
|
return tcd;
|
|
}
|
|
EXPORT_SYMBOL_GPL(devm_thermal_of_cooling_device_register);
|
|
|
|
static bool thermal_cooling_device_present(struct thermal_cooling_device *cdev)
|
|
{
|
|
struct thermal_cooling_device *pos = NULL;
|
|
|
|
list_for_each_entry(pos, &thermal_cdev_list, node) {
|
|
if (pos == cdev)
|
|
return true;
|
|
}
|
|
|
|
return false;
|
|
}
|
|
|
|
/**
|
|
* thermal_cooling_device_update - Update a cooling device object
|
|
* @cdev: Target cooling device.
|
|
*
|
|
* Update @cdev to reflect a change of the underlying hardware or platform.
|
|
*
|
|
* Must be called when the maximum cooling state of @cdev becomes invalid and so
|
|
* its .get_max_state() callback needs to be run to produce the new maximum
|
|
* cooling state value.
|
|
*/
|
|
void thermal_cooling_device_update(struct thermal_cooling_device *cdev)
|
|
{
|
|
struct thermal_instance *ti;
|
|
unsigned long state;
|
|
|
|
if (IS_ERR_OR_NULL(cdev))
|
|
return;
|
|
|
|
/*
|
|
* Hold thermal_list_lock throughout the update to prevent the device
|
|
* from going away while being updated.
|
|
*/
|
|
mutex_lock(&thermal_list_lock);
|
|
|
|
if (!thermal_cooling_device_present(cdev))
|
|
goto unlock_list;
|
|
|
|
/*
|
|
* Update under the cdev lock to prevent the state from being set beyond
|
|
* the new limit concurrently.
|
|
*/
|
|
mutex_lock(&cdev->lock);
|
|
|
|
if (cdev->ops->get_max_state(cdev, &cdev->max_state))
|
|
goto unlock;
|
|
|
|
thermal_cooling_device_stats_reinit(cdev);
|
|
|
|
list_for_each_entry(ti, &cdev->thermal_instances, cdev_node) {
|
|
if (ti->upper == cdev->max_state)
|
|
continue;
|
|
|
|
if (ti->upper < cdev->max_state) {
|
|
if (ti->upper_no_limit)
|
|
ti->upper = cdev->max_state;
|
|
|
|
continue;
|
|
}
|
|
|
|
ti->upper = cdev->max_state;
|
|
if (ti->lower > ti->upper)
|
|
ti->lower = ti->upper;
|
|
|
|
if (ti->target == THERMAL_NO_TARGET)
|
|
continue;
|
|
|
|
if (ti->target > ti->upper)
|
|
ti->target = ti->upper;
|
|
}
|
|
|
|
if (cdev->ops->get_cur_state(cdev, &state) || state > cdev->max_state)
|
|
goto unlock;
|
|
|
|
thermal_cooling_device_stats_update(cdev, state);
|
|
|
|
unlock:
|
|
mutex_unlock(&cdev->lock);
|
|
|
|
unlock_list:
|
|
mutex_unlock(&thermal_list_lock);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_cooling_device_update);
|
|
|
|
/**
|
|
* thermal_cooling_device_unregister - removes a thermal cooling device
|
|
* @cdev: the thermal cooling device to remove.
|
|
*
|
|
* thermal_cooling_device_unregister() must be called when a registered
|
|
* thermal cooling device is no longer needed.
|
|
*/
|
|
void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
|
|
{
|
|
struct thermal_zone_device *tz;
|
|
|
|
if (!cdev)
|
|
return;
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
|
|
if (!thermal_cooling_device_present(cdev)) {
|
|
mutex_unlock(&thermal_list_lock);
|
|
return;
|
|
}
|
|
|
|
list_del(&cdev->node);
|
|
|
|
/* Unbind all thermal zones associated with 'this' cdev */
|
|
list_for_each_entry(tz, &thermal_tz_list, node) {
|
|
if (tz->ops->unbind)
|
|
tz->ops->unbind(tz, cdev);
|
|
}
|
|
|
|
mutex_unlock(&thermal_list_lock);
|
|
|
|
device_unregister(&cdev->device);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_cooling_device_unregister);
|
|
|
|
static void bind_tz(struct thermal_zone_device *tz)
|
|
{
|
|
int ret;
|
|
struct thermal_cooling_device *pos = NULL;
|
|
|
|
if (!tz->ops->bind)
|
|
return;
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
|
|
list_for_each_entry(pos, &thermal_cdev_list, node) {
|
|
ret = tz->ops->bind(tz, pos);
|
|
if (ret)
|
|
print_bind_err_msg(tz, pos, ret);
|
|
}
|
|
|
|
mutex_unlock(&thermal_list_lock);
|
|
}
|
|
|
|
static void thermal_set_delay_jiffies(unsigned long *delay_jiffies, int delay_ms)
|
|
{
|
|
*delay_jiffies = msecs_to_jiffies(delay_ms);
|
|
if (delay_ms > 1000)
|
|
*delay_jiffies = round_jiffies(*delay_jiffies);
|
|
}
|
|
|
|
int thermal_zone_get_crit_temp(struct thermal_zone_device *tz, int *temp)
|
|
{
|
|
int i, ret = -EINVAL;
|
|
|
|
if (tz->ops->get_crit_temp)
|
|
return tz->ops->get_crit_temp(tz, temp);
|
|
|
|
if (!tz->trips)
|
|
return -EINVAL;
|
|
|
|
mutex_lock(&tz->lock);
|
|
|
|
for (i = 0; i < tz->num_trips; i++) {
|
|
if (tz->trips[i].type == THERMAL_TRIP_CRITICAL) {
|
|
*temp = tz->trips[i].temperature;
|
|
ret = 0;
|
|
break;
|
|
}
|
|
}
|
|
|
|
mutex_unlock(&tz->lock);
|
|
|
|
return ret;
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_get_crit_temp);
|
|
|
|
/**
|
|
* thermal_zone_device_register_with_trips() - register a new thermal zone device
|
|
* @type: the thermal zone device type
|
|
* @trips: a pointer to an array of thermal trips
|
|
* @num_trips: the number of trip points the thermal zone support
|
|
* @mask: a bit string indicating the writeablility of trip points
|
|
* @devdata: private device data
|
|
* @ops: standard thermal zone device callbacks
|
|
* @tzp: thermal zone platform parameters
|
|
* @passive_delay: number of milliseconds to wait between polls when
|
|
* performing passive cooling
|
|
* @polling_delay: number of milliseconds to wait between polls when checking
|
|
* whether trip points have been crossed (0 for interrupt
|
|
* driven systems)
|
|
*
|
|
* This interface function adds a new thermal zone device (sensor) to
|
|
* /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
|
|
* thermal cooling devices registered at the same time.
|
|
* thermal_zone_device_unregister() must be called when the device is no
|
|
* longer needed. The passive cooling depends on the .get_trend() return value.
|
|
*
|
|
* Return: a pointer to the created struct thermal_zone_device or an
|
|
* in case of error, an ERR_PTR. Caller must check return value with
|
|
* IS_ERR*() helpers.
|
|
*/
|
|
struct thermal_zone_device *
|
|
thermal_zone_device_register_with_trips(const char *type, struct thermal_trip *trips, int num_trips, int mask,
|
|
void *devdata, struct thermal_zone_device_ops *ops,
|
|
const struct thermal_zone_params *tzp, int passive_delay,
|
|
int polling_delay)
|
|
{
|
|
struct thermal_zone_device *tz;
|
|
int id;
|
|
int result;
|
|
struct thermal_governor *governor;
|
|
|
|
if (!type || strlen(type) == 0) {
|
|
pr_err("No thermal zone type defined\n");
|
|
return ERR_PTR(-EINVAL);
|
|
}
|
|
|
|
if (strlen(type) >= THERMAL_NAME_LENGTH) {
|
|
pr_err("Thermal zone name (%s) too long, should be under %d chars\n",
|
|
type, THERMAL_NAME_LENGTH);
|
|
return ERR_PTR(-EINVAL);
|
|
}
|
|
|
|
/*
|
|
* Max trip count can't exceed 31 as the "mask >> num_trips" condition.
|
|
* For example, shifting by 32 will result in compiler warning:
|
|
* warning: right shift count >= width of type [-Wshift-count- overflow]
|
|
*
|
|
* Also "mask >> num_trips" will always be true with 32 bit shift.
|
|
* E.g. mask = 0x80000000 for trip id 31 to be RW. Then
|
|
* mask >> 32 = 0x80000000
|
|
* This will result in failure for the below condition.
|
|
*
|
|
* Check will be true when the bit 31 of the mask is set.
|
|
* 32 bit shift will cause overflow of 4 byte integer.
|
|
*/
|
|
if (num_trips > (BITS_PER_TYPE(int) - 1) || num_trips < 0 || mask >> num_trips) {
|
|
pr_err("Incorrect number of thermal trips\n");
|
|
return ERR_PTR(-EINVAL);
|
|
}
|
|
|
|
if (!ops) {
|
|
pr_err("Thermal zone device ops not defined\n");
|
|
return ERR_PTR(-EINVAL);
|
|
}
|
|
|
|
if (num_trips > 0 && !trips)
|
|
return ERR_PTR(-EINVAL);
|
|
|
|
if (!thermal_class)
|
|
return ERR_PTR(-ENODEV);
|
|
|
|
tz = kzalloc(sizeof(*tz), GFP_KERNEL);
|
|
if (!tz)
|
|
return ERR_PTR(-ENOMEM);
|
|
|
|
if (tzp) {
|
|
tz->tzp = kmemdup(tzp, sizeof(*tzp), GFP_KERNEL);
|
|
if (!tz->tzp) {
|
|
result = -ENOMEM;
|
|
goto free_tz;
|
|
}
|
|
}
|
|
|
|
INIT_LIST_HEAD(&tz->thermal_instances);
|
|
ida_init(&tz->ida);
|
|
mutex_init(&tz->lock);
|
|
id = ida_alloc(&thermal_tz_ida, GFP_KERNEL);
|
|
if (id < 0) {
|
|
result = id;
|
|
goto free_tzp;
|
|
}
|
|
|
|
tz->id = id;
|
|
strscpy(tz->type, type, sizeof(tz->type));
|
|
|
|
if (!ops->critical)
|
|
ops->critical = thermal_zone_device_critical;
|
|
|
|
tz->ops = ops;
|
|
tz->device.class = thermal_class;
|
|
tz->devdata = devdata;
|
|
tz->trips = trips;
|
|
tz->num_trips = num_trips;
|
|
|
|
thermal_set_delay_jiffies(&tz->passive_delay_jiffies, passive_delay);
|
|
thermal_set_delay_jiffies(&tz->polling_delay_jiffies, polling_delay);
|
|
|
|
/* sys I/F */
|
|
/* Add nodes that are always present via .groups */
|
|
result = thermal_zone_create_device_groups(tz, mask);
|
|
if (result)
|
|
goto remove_id;
|
|
|
|
/* A new thermal zone needs to be updated anyway. */
|
|
atomic_set(&tz->need_update, 1);
|
|
|
|
result = dev_set_name(&tz->device, "thermal_zone%d", tz->id);
|
|
if (result) {
|
|
thermal_zone_destroy_device_groups(tz);
|
|
goto remove_id;
|
|
}
|
|
result = device_register(&tz->device);
|
|
if (result)
|
|
goto release_device;
|
|
|
|
/* Update 'this' zone's governor information */
|
|
mutex_lock(&thermal_governor_lock);
|
|
|
|
if (tz->tzp)
|
|
governor = __find_governor(tz->tzp->governor_name);
|
|
else
|
|
governor = def_governor;
|
|
|
|
result = thermal_set_governor(tz, governor);
|
|
if (result) {
|
|
mutex_unlock(&thermal_governor_lock);
|
|
goto unregister;
|
|
}
|
|
|
|
mutex_unlock(&thermal_governor_lock);
|
|
|
|
if (!tz->tzp || !tz->tzp->no_hwmon) {
|
|
result = thermal_add_hwmon_sysfs(tz);
|
|
if (result)
|
|
goto unregister;
|
|
}
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
list_add_tail(&tz->node, &thermal_tz_list);
|
|
mutex_unlock(&thermal_list_lock);
|
|
|
|
/* Bind cooling devices for this zone */
|
|
bind_tz(tz);
|
|
|
|
INIT_DELAYED_WORK(&tz->poll_queue, thermal_zone_device_check);
|
|
|
|
thermal_zone_device_init(tz);
|
|
/* Update the new thermal zone and mark it as already updated. */
|
|
if (atomic_cmpxchg(&tz->need_update, 1, 0))
|
|
thermal_zone_device_update(tz, THERMAL_EVENT_UNSPECIFIED);
|
|
|
|
thermal_notify_tz_create(tz->id, tz->type);
|
|
|
|
return tz;
|
|
|
|
unregister:
|
|
device_del(&tz->device);
|
|
release_device:
|
|
put_device(&tz->device);
|
|
tz = NULL;
|
|
remove_id:
|
|
ida_free(&thermal_tz_ida, id);
|
|
free_tzp:
|
|
kfree(tz->tzp);
|
|
free_tz:
|
|
kfree(tz);
|
|
return ERR_PTR(result);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_device_register_with_trips);
|
|
|
|
struct thermal_zone_device *thermal_tripless_zone_device_register(
|
|
const char *type,
|
|
void *devdata,
|
|
struct thermal_zone_device_ops *ops,
|
|
const struct thermal_zone_params *tzp)
|
|
{
|
|
return thermal_zone_device_register_with_trips(type, NULL, 0, 0, devdata,
|
|
ops, tzp, 0, 0);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_tripless_zone_device_register);
|
|
|
|
void *thermal_zone_device_priv(struct thermal_zone_device *tzd)
|
|
{
|
|
return tzd->devdata;
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_device_priv);
|
|
|
|
const char *thermal_zone_device_type(struct thermal_zone_device *tzd)
|
|
{
|
|
return tzd->type;
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_device_type);
|
|
|
|
int thermal_zone_device_id(struct thermal_zone_device *tzd)
|
|
{
|
|
return tzd->id;
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_device_id);
|
|
|
|
struct device *thermal_zone_device(struct thermal_zone_device *tzd)
|
|
{
|
|
return &tzd->device;
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_device);
|
|
|
|
/**
|
|
* thermal_zone_device_unregister - removes the registered thermal zone device
|
|
* @tz: the thermal zone device to remove
|
|
*/
|
|
void thermal_zone_device_unregister(struct thermal_zone_device *tz)
|
|
{
|
|
int tz_id;
|
|
struct thermal_cooling_device *cdev;
|
|
struct thermal_zone_device *pos = NULL;
|
|
|
|
if (!tz)
|
|
return;
|
|
|
|
tz_id = tz->id;
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
list_for_each_entry(pos, &thermal_tz_list, node)
|
|
if (pos == tz)
|
|
break;
|
|
if (pos != tz) {
|
|
/* thermal zone device not found */
|
|
mutex_unlock(&thermal_list_lock);
|
|
return;
|
|
}
|
|
list_del(&tz->node);
|
|
|
|
/* Unbind all cdevs associated with 'this' thermal zone */
|
|
list_for_each_entry(cdev, &thermal_cdev_list, node)
|
|
if (tz->ops->unbind)
|
|
tz->ops->unbind(tz, cdev);
|
|
|
|
mutex_unlock(&thermal_list_lock);
|
|
|
|
cancel_delayed_work_sync(&tz->poll_queue);
|
|
|
|
thermal_set_governor(tz, NULL);
|
|
|
|
thermal_remove_hwmon_sysfs(tz);
|
|
ida_free(&thermal_tz_ida, tz->id);
|
|
ida_destroy(&tz->ida);
|
|
|
|
mutex_lock(&tz->lock);
|
|
device_del(&tz->device);
|
|
mutex_unlock(&tz->lock);
|
|
|
|
kfree(tz->tzp);
|
|
|
|
put_device(&tz->device);
|
|
|
|
thermal_notify_tz_delete(tz_id);
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_device_unregister);
|
|
|
|
/**
|
|
* thermal_zone_get_zone_by_name() - search for a zone and returns its ref
|
|
* @name: thermal zone name to fetch the temperature
|
|
*
|
|
* When only one zone is found with the passed name, returns a reference to it.
|
|
*
|
|
* Return: On success returns a reference to an unique thermal zone with
|
|
* matching name equals to @name, an ERR_PTR otherwise (-EINVAL for invalid
|
|
* paramenters, -ENODEV for not found and -EEXIST for multiple matches).
|
|
*/
|
|
struct thermal_zone_device *thermal_zone_get_zone_by_name(const char *name)
|
|
{
|
|
struct thermal_zone_device *pos = NULL, *ref = ERR_PTR(-EINVAL);
|
|
unsigned int found = 0;
|
|
|
|
if (!name)
|
|
goto exit;
|
|
|
|
mutex_lock(&thermal_list_lock);
|
|
list_for_each_entry(pos, &thermal_tz_list, node)
|
|
if (!strncasecmp(name, pos->type, THERMAL_NAME_LENGTH)) {
|
|
found++;
|
|
ref = pos;
|
|
}
|
|
mutex_unlock(&thermal_list_lock);
|
|
|
|
/* nothing has been found, thus an error code for it */
|
|
if (found == 0)
|
|
ref = ERR_PTR(-ENODEV);
|
|
else if (found > 1)
|
|
/* Success only when an unique zone is found */
|
|
ref = ERR_PTR(-EEXIST);
|
|
|
|
exit:
|
|
return ref;
|
|
}
|
|
EXPORT_SYMBOL_GPL(thermal_zone_get_zone_by_name);
|
|
|
|
static int thermal_pm_notify(struct notifier_block *nb,
|
|
unsigned long mode, void *_unused)
|
|
{
|
|
struct thermal_zone_device *tz;
|
|
|
|
switch (mode) {
|
|
case PM_HIBERNATION_PREPARE:
|
|
case PM_RESTORE_PREPARE:
|
|
case PM_SUSPEND_PREPARE:
|
|
atomic_set(&in_suspend, 1);
|
|
break;
|
|
case PM_POST_HIBERNATION:
|
|
case PM_POST_RESTORE:
|
|
case PM_POST_SUSPEND:
|
|
atomic_set(&in_suspend, 0);
|
|
list_for_each_entry(tz, &thermal_tz_list, node) {
|
|
thermal_zone_device_init(tz);
|
|
thermal_zone_device_update(tz,
|
|
THERMAL_EVENT_UNSPECIFIED);
|
|
}
|
|
break;
|
|
default:
|
|
break;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
static struct notifier_block thermal_pm_nb = {
|
|
.notifier_call = thermal_pm_notify,
|
|
};
|
|
|
|
static int __init thermal_init(void)
|
|
{
|
|
int result;
|
|
|
|
result = thermal_netlink_init();
|
|
if (result)
|
|
goto error;
|
|
|
|
result = thermal_register_governors();
|
|
if (result)
|
|
goto unregister_netlink;
|
|
|
|
thermal_class = kzalloc(sizeof(*thermal_class), GFP_KERNEL);
|
|
if (!thermal_class) {
|
|
result = -ENOMEM;
|
|
goto unregister_governors;
|
|
}
|
|
|
|
thermal_class->name = "thermal";
|
|
thermal_class->dev_release = thermal_release;
|
|
|
|
result = class_register(thermal_class);
|
|
if (result) {
|
|
kfree(thermal_class);
|
|
thermal_class = NULL;
|
|
goto unregister_governors;
|
|
}
|
|
|
|
result = register_pm_notifier(&thermal_pm_nb);
|
|
if (result)
|
|
pr_warn("Thermal: Can not register suspend notifier, return %d\n",
|
|
result);
|
|
|
|
return 0;
|
|
|
|
unregister_governors:
|
|
thermal_unregister_governors();
|
|
unregister_netlink:
|
|
thermal_netlink_exit();
|
|
error:
|
|
mutex_destroy(&thermal_list_lock);
|
|
mutex_destroy(&thermal_governor_lock);
|
|
return result;
|
|
}
|
|
postcore_initcall(thermal_init);
|