mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-12-28 05:24:47 +08:00
b350de6fa9
This code groups in one place default settings of trip points. It is used in SoCs with multiple instances of TMU sensor. Separate device tree file prevents from multiple copying of the same data. Signed-off-by: Lukasz Majewski <l.majewski@samsung.com> Acked-by: Eduardo Valentin <edubezval@gmail.com> Signed-off-by: Kukjin Kim <kgene@kernel.org>
36 lines
899 B
Plaintext
36 lines
899 B
Plaintext
/*
|
|
* Device tree sources for default Exynos5420 thermal zone definition
|
|
*
|
|
* Copyright (c) 2014 Lukasz Majewski <l.majewski@samsung.com>
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License version 2 as
|
|
* published by the Free Software Foundation.
|
|
*
|
|
*/
|
|
|
|
polling-delay-passive = <0>;
|
|
polling-delay = <0>;
|
|
trips {
|
|
cpu-alert-0 {
|
|
temperature = <85000>; /* millicelsius */
|
|
hysteresis = <10000>; /* millicelsius */
|
|
type = "active";
|
|
};
|
|
cpu-alert-1 {
|
|
temperature = <103000>; /* millicelsius */
|
|
hysteresis = <10000>; /* millicelsius */
|
|
type = "active";
|
|
};
|
|
cpu-alert-2 {
|
|
temperature = <110000>; /* millicelsius */
|
|
hysteresis = <10000>; /* millicelsius */
|
|
type = "active";
|
|
};
|
|
cpu-crit-0 {
|
|
temperature = <1200000>; /* millicelsius */
|
|
hysteresis = <0>; /* millicelsius */
|
|
type = "critical";
|
|
};
|
|
};
|