e63273c1bc Documentation: admin-guide: Add toctree entry for thermal docs
kernel test robot reported htmldocs warnings:

Documentation/admin-guide/index.rst:62: WARNING: toctree contains reference to nonexisting document 'admin-guide/thermal'
Documentation/admin-guide/thermal/intel_powerclamp.rst: WARNING: document isn't included in any toctree

Add toctree entry for thermal/ docs to fix these warnings.

Link: https://lore.kernel.org/linux-doc/202302121759.MmJgDTxc-lkp@intel.com/
Fixes: 707bf8e1df ("Documentation: admin-guide: Move intel_powerclamp documentation")
Reported-by: kernel test robot <lkp@intel.com>
Signed-off-by: Bagas Sanjaya <bagasdotme@gmail.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2023-02-13 16:30:43 +01:00
Srinivas Pandruvada
ebf5197102 thermal: intel: powerclamp: Add two module parameters
In some use cases, it is desirable to only inject idle on certain set
of CPUs. For example on Alder Lake systems, it is possible that we force
idle only on P-Cores for thermal reasons. Also the idle percent can be
more than 50% if we only choose partial set of CPUs in the system.

Introduce 2 new module parameters for this purpose. They can be only
changed when the cooling device is inactive.

cpumask (Read/Write): A bit mask of CPUs to inject idle. The format of
this bitmask is same as used in other subsystems like in
/proc/irq/*/smp_affinity. The mask is comma separated 32 bit groups.
Each CPU is one bit. For example for 256 CPU system the full mask is:
ffffffff,ffffffff,ffffffff,ffffffff,ffffffff,ffffffff,ffffffff,ffffffff
The rightmost mask is for CPU 0-32.

max_idle (Read/Write): Maximum injected idle time to the total CPU time
ratio in percent range from 1 to 100. Even if the cooling device max_state
is always 100 (100%), this parameter allows to add a max idle percent
limit. The default is 50, to match the current implementation of powerclamp
driver. Also doesn't allow value more than 75, if the cpumask includes
every CPU present in the system.

Also when the cpumask doesn't include every CPU, there is no use of
compensation using package C-state idle counters. Hence don't start
package C-state polling thread even for a single package or a single die
system in this case.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2023-02-09 21:01:06 +01:00
Srinivas Pandruvada
707bf8e1df Documentation: admin-guide: Move intel_powerclamp documentation
Create a folder "thermal" under Documentation/admin-guide and move
intel_powerclamp documentation to this folder.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2023-02-09 20:53:39 +01:00