The following build warning is seen in some configurations.
drivers/hwmon/ad7314.c: In function 'ad7314_show_temperature':
drivers/hwmon/ad7314.c:70: warning: 'data' may be used uninitialized in this function
Fix by overloading the return value from ad7314_spi_read with both data and
error code (the returned data is really u16 and needs to be converted into a
signed value anyway).
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Cc: Jonathan Cameron <jic23@cam.ac.uk>
Acked-by: Jean Delvare <khali@linux-fr.org>
This driver was recently moved from IIO (where it worked) to hwmon (where
it doesn't.) This breakage occured because the hwmon version neglected to
correctly initialize a reference to spi_dev in its drvdata. The result is a
segfault every time the temperature is queried.
Signed-off-by: Graeme Smecher <gsmecher@threespeedlogic.com>
Cc: stable@vger.kernel.org # 3.2+
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
This patch converts the drivers in drivers/hwmon/* to use the
module_spi_driver() macro which makes the code smaller and a bit simpler.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Cc: Sonic Zhang <sonic.zhang@analog.com>
Cc: Marc Pignat <marc.pignat@hevs.ch>
Cc: Paul Thomas <pthomas8589@gmail.com>
Cc: Eric Miao <eric.y.miao@gmail.com>
Acked-by: Sonic Zhang <sonic.zhang@analog.com>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
In ancient times it was necessary to manually initialize the bus field of an
spi_driver to spi_bus_type. These days this is done in spi_register_driver(),
so we can drop the manual assignment.
The patch was generated using the following coccinelle semantic patch:
// <smpl>
@@
identifier _driver;
@@
struct spi_driver _driver = {
.driver = {
- .bus = &spi_bus_type,
},
};
// </smpl>
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Cc: Jean Delvare <khali@linux-fr.org>
Cc: Guenter Roeck <guenter.roeck@ericsson.com>
Cc: lm-sensors@lm-sensors.org
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Driver for AD7314, ADT7301, and ADT7302, ported from IIO.
Currently dropped power down mode support.
Signed-off-by: Jonathan Cameron <jic23@cam.ac.uk>
[guenter.roeck@ericsson.com: Added MODULE_DEVICE_TABLE]
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>