Commit Graph

3 Commits

Author SHA1 Message Date
Daniel Lezcano
ccc42592d4 clocksource/drivers/rockchip: Fix bad NO_IRQ usage
The current code assumes the 'irq_of_parse_and_map' will return NO_IRQ in case
of failure. Unfortunately, the NO_IRQ is not consistent across the different
architectures and we must not rely on it.

NO_IRQ is equal to '-1' on ARM and 'irq_of_parse_and_map' returns '0' in case
of an error. Hence, the latter won't be detected and will lead to a crash.

Fix this by just checking 'irq' is different from zero.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
2015-09-29 14:33:34 +02:00
Viresh Kumar
99b3fa72ef clockevents/drivers/rockchip: Migrate to new 'set-state' interface
Migrate rockchip driver to the new 'set-state' interface provided by
clockevents core, the earlier 'set-mode' interface is marked obsolete
now.

This also enables us to implement callbacks for new states of clockevent
devices, for example: ONESHOT_STOPPED.

We weren't doing anything for oneshot or resume modes, and so the
callbacks aren't provided.

Cc: Heiko Stuebner <heiko@sntech.de>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
2015-08-10 11:40:36 +02:00
Daniel Lezcano
468b8c4cf3 clockevents: rockchip: Add rockchip timer for rk3288
The rk3288 board uses the architected timers and these ones are shutdown when
the cpu is powered down. There is a need of a broadcast timer in this case to
ensure proper wakeup when the cpus are in sleep mode and a timer expires.

This driver provides the basic timer functionnality as a backup for the local
timers at sleep time.

The timer belongs to the alive subsystem. It includes two programmables 64 bits
timer channels but the driver only uses 32bits. It works with two operations
mode: free running and user defined count.

Programing sequence:

1. Timer initialization:
 * Disable the timer by writing '0' to the CONTROLREG register
 * Program the timer mode by writing the mode to the CONTROLREG register
 * Set the interrupt mask

2. Setting the count value:
 * Load the count value to the registers COUNT0 and COUNT1 (not used).

3. Enable the timer
 * Write '1' to the CONTROLREG register with the mode (free running or user)

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Reviewed-by: Heiko Stuebner <heiko@sntech.de>
2015-01-29 14:02:13 +01:00