Commit Graph

7 Commits

Author SHA1 Message Date
Sumit.Saxena@lsi.com
bc93d425fc [SCSI] megaraid_sas: Add support for Uneven Span PRL11
MegaRAID older Firmware does not support uneven span configuration for PRL11.
E.g User wants to create 34 Driver PRL11 config, it was not possible using old
firmware, since it was not supported configuration in old firmware

Old Firmware expect even number of Drives in each span and same number of
physical drives at each span.  Considering above design, 17 Drives at Span-0
and 17 drives at span-1 was not possible.

Now, using this new feature Firmware and Driver both required changes.  New
Firmware can allow user to create 16 Drives at span-0 and 18 Drives at
span-1. This will allow user to create 34 Drives Uneven span PRL11.

RAID map is interface between Driver and FW to fetch all required
fields(attributes) for each Virtual Drives.  Since legacy RAID map consider
Even Span design, there was no place to keep Uneven span information in
existing Raid map.  Because of this limitation, for Uneven span VD, driver can
not use RAID map.

This patch address the changes required in Driver to support Uneven span PRL11
support.

1. Driver will find if Firmware has UnevenSpanSupport or not by reading
   Controller Info.
2. If Firmware has UnvenSpan PRL11 support, then Driver will inform about its
   capability of handling UnevenSpan PRL11 to the firmware.
3. Driver will update its copy of span info on each time Raid map update is
   called.
4. Follow different IO path if it is Uneven Span. (For Uneven Span, Driver
   uses Span Set info to find relavent fields for that particular Virtual
   Disk)

More verbose prints will be available by setting "SPAN_DEBUG" to 1 at
compilation time.

Signed-off-by: Sumit Saxena <sumit.saxena@lsi.com>
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
2013-06-24 17:48:12 -07:00
Sumit.Saxena@lsi.com
d46a3ad679 [SCSI] megaraid_sas: Add support for Extended MSI-x vectors for 12Gb/s controller
This Driver will use more than 8 MSI-x support provided by Invader/Fury max
upto 128 MSI-x.

[jejb: fix checkpatch warning]
Signed-off-by: Sumit Saxena <sumit.saxena@lsi.com>
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
2013-06-24 17:46:31 -07:00
adam radford
046c9ec259 [SCSI] megaraid_sas: Add 4k FastPath DIF support
The following patch for megaraid_sas will allow Fastpath T10PI/DIF
frame builds to work with 4k sector size.

Signed-off-by: Adam Radford <aradford@gmail.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
2013-02-22 15:25:18 +00:00
adam radford
ae59057b64 [SCSI] megaraid_sas: Version, Changelog, Copyright update
Signed-off-by: Adam Radford <aradford@gmail.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
2012-10-09 11:21:48 +01:00
adam radford
c8e858fe72 [SCSI] megaraid_sas: Add multiple MSI-X vector/multiple reply queue support
Signed-off-by: Adam Radford <aradford@gmail.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
2011-10-16 11:21:36 -05:00
adam radford
36807e6799 [SCSI] megaraid_sas: Add support for MegaRAID 9360/9380 12GB/s controllers
Signed-off-by: Adam Radford <aradford@gmail.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
2011-10-16 11:21:08 -05:00
adam radford
9c915a8c99 [SCSI] megaraid_sas: Add 9565/9285 specific code
This patch adds MegaRAID 9265/9285 (Device id 0x5b) specific code

Signed-off-by: Adam Radford <aradford@gmail.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2010-12-22 23:26:53 -06:00