Christian Eggers
23e0618ca0 iio: light: as73211: Increase measurement timeout
We found some sensors which are much slower (20% at room temperature)
than nominal. According to the data sheet, up to 27% is possible. Now I
add 33% to the nominal time out, hopefully this is enough.

Signed-off-by: Christian Eggers <ceggers@arri.de>
Link: https://lore.kernel.org/r/20200909154439.10308-1-ceggers@arri.de
Fixes: 403e5586b5 ("iio: light: as73211: New driver")
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-09-13 10:37:46 +01:00
Christian Eggers
403e5586b5 iio: light: as73211: New driver
Support for AMS AS73211 JENCOLOR(R) Digital XYZ Sensor.

This driver has no built-in trigger. In order for making triggered
measurements, an external (software) trigger driver like
iio-trig-hrtimer or iio-trig-sysfs is required.

The sensor supports single and continuous measurement modes. The latter
is not used by design as this would require tight timing synchronization
between hardware and driver without much benefit.

Datasheet: https://ams.com/documents/20143/36005/AS73211_DS000556_3-01.pdf
Signed-off-by: Christian Eggers <ceggers@arri.de>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-09-03 19:40:40 +01:00