The hdmi driver currently updates only the 'code' member of hdmi_config when
the op omapdss_hdmi_display_set_timing() is called by the hdmi panel driver.
The 'timing' field of hdmi_config is updated only when hdmi_power_on is called.
It makes more sense to configure the whole hdmi_config field in the set_timing
op called by the panel driver. This way, we don't need to call both functions
to ensure that our hdmi_config is configured correctly. Also, we don't need to
calculate hdmi_config during hdmi_power_on, or rely on the omap_video_timings
in the panel's omap_dss_device struct.
The default timings of the hdmi panel are represented in a cleaner form. Since
the hdmi output is now configured by it's own copy of timings (in
hdmi.ip_data.cfg), the panel driver needs to set it to a valid value before
enabling hdmi output. We now call omapdss_hdmi_set_timing() before enabling
hdmi output, this is done to atleast have the hdmi output configured to the
panel's default timings if the DSS user didn't call panel driver's set_timings()
op explicitly.
Signed-off-by: Archit Taneja <archit@ti.com>
During a command mode update using DISPC video port, we may need to swap the
connected overlay manager's width and height when 90 or 270 degree rotation is
done via the panel by changing it's address mode.
Call dss_mgr_set_timings() in update_screen_dispc() before starting the manager
update. The new manager size is updated in the 'timings' field of DSI driver's
private data via omapdss_dsi_set_size(). A panel driver is expected to call this
when performing rotation.
Signed-off-by: Archit Taneja <archit@ti.com>
DSI command mode panels don't need to configure a full set of timings to
configure DSI, they only require the width and the height of the panel in
pixels.
Use omapdss_dsi_set_size for command mode panels, omapdss_dsi_set_timings is
meant for video mode panels. When performing rotation via chaning the address
mode of the panel, we would need to swap width and height when doing 90 or 270
rotation. Make sure that omapdss_dsi_set_size() makes the new width and height
visible to DSI.
Signed-off-by: Archit Taneja <archit@ti.com>
The DSI driver currently relies on the timings in omap_dss_device struct to
configure the DISPC and DSI blocks accordingly. This makes the DSI interface
driver dependent on the omap_dss_device struct.
Make the DSI driver data maintain it's own timings field. A DSI video mode panel
driver is expected to call omapdss_dsi_set_timings() to set these timings before
the panel is enabled.
Signed-off-by: Archit Taneja <archit@ti.com>
The timings maintained in omap_dss_device(dssdev->panel.timings) should be
maintained by the panel driver itself. It's the panel drivers responsibility
to update it if a new set of timings is to be configured. The DPI interface
driver shouldn't be responsible of updating the panel timings, it's responsible
of maintianing it's own copy of timings.
Signed-off-by: Archit Taneja <archit@ti.com>
The DPI driver currently relies on the timings in omap_dss_device struct to
configure the DISPC accordingly. This makes the DPI interface driver dependent
on the omap_dss_device struct.
Make the DPI driver data maintain it's own timings field. The panel driver is
expected to call dpi_set_timings()(renamed to omapdss_dpi_set_timings) to set
these timings before the panel is enabled.
In the set_timings() op, we still ensure that the omap_dss_device timings
(dssdev->panel.timings) are configured. This will later be configured only by
the DPI panel drivers.
Signed-off-by: Archit Taneja <archit@ti.com>
The generic DPI panel driver doesn't currently have locking to ensure that
the display states and the driver data is maintained correctly. Add mutex
locking to take care of this. Add a new get_timings driver op to override the
default get_timings op. The new driver op contains locking to ensure the correct
panel timings are seen when a DSS2 user calls device->driver->get_timings.
Signed-off-by: Archit Taneja <archit@ti.com>
The DPI interface driver currently relies on the panel driver to ensure calls
like omapdss_dpi_display_enable() and omapdss_dpi_display_disable() are executed
sequentially. Also, currently, there is no way to protect the DPI driver data.
All DPI panel drivers don't ensure this, and in general, a DPI panel driver
should use it's lock to that ensure it's own driver data and omap_dss_device
states are taken care of, and not worry about the DPI interface.
Add mutex locking in the DPI enable/disable/set_timings ops.
Signed-off-by: Archit Taneja <archit@ti.com>
The function dss_mgr_set_timings is supposed to apply timings passed by an
interface driver. It is not supposed to change the timings. Add const qualifier
to the omap_video_timings pointer argument in dss_mgr_set_timings().
Signed-off-by: Archit Taneja <archit@ti.com>
omapfb does not currently set pseudo palette correctly for color depths
above 16bpp, making red text invisible, command like
echo -e '\e[0;31mRED' > /dev/tty1
will display nothing on framebuffer console in 24bpp mode.
This is because temporary variable is declared incorrectly, fix it.
Signed-off-by: Grazvydas Ignotas <notasas@gmail.com>
Cc: stable@vger.kernel.org
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
DSS code wrongly assumes that VENC is always available as source for the external
sync signal for the display controller DIGIT channel. One cannot blindly write/read
the value of DSS_CONTROL[15] as in certain processors (e.g., OMAP5) this operation
may not be valid. If the the sync source is not read correctly, the callers of
dss_get_hdmi_venc_clk_source might make wrong assumptions about, for instance,
video timings.
Logic is added to correctly get the sync signal based on the available displays
in the DIGIT channel. The source is set only if both VENC and HDMI are supported.
Signed-off-by: Ricardo Neri <ricardo.neri@ti.com>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
We have no reason to block in the error handler workqueue, so use msleep.
Signed-off-by: Jassi Brar <jaswinder.singh@linaro.org>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
Small patch to disable the PLL appropriately before runtime_put in case
an error occurs while enabling the PHY.
Signed-off-by: Ricardo Neri <ricardo.neri@ti.com>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
Replication logic for an overlay depends on the color mode in which it is
configured and the video port width of the manager it is connected to.
video port width now held in dss_lcd_mgr_config in the manager's private
data in APPLY. Use this instead of referring to the omap_dss_device connected to
the manager.
Replication is enabled in the case of TV manager, the video_port_width is set to
a default value of 24 for TV manager.
Make the replication checking an overlay function since it's more of an overlay
characteristic than a display characteristic.
Signed-off-by: Archit Taneja <archit@ti.com>
The RFBI driver uses a direct DISPC register write to enable the overlay
manager. Replace this with dss_mgr_enable() which checks if the connected
overlay and managers are correctly configured, and configure DSS for
fifomerge.
Signed-off-by: Archit Taneja <archit@ti.com>
dss_mgr_is_lcd() available in dss.h does the same thing as dispc_mgr_is_lcd()
in dispc.c. Remove the function from dispc.c and replace it with the one in
dss.h.
Signed-off-by: Archit Taneja <archit@ti.com>
APPLY needs to know at certain places whether an overlay manager is in manual
or auto update mode. The caps of the connected omap_dss_device were used to
check that.
A LCD manager is in manual update if stallmode is enabled for that manager. TV
managers for now always auto update.
Return the value of stallmode parameter in the private data 'lcd_confg' in
mgr_manual_update() and ovl_manual_update(), for TV managers stallmode field
will be false by default.
Signed-off-by: Archit Taneja <archit@ti.com>
The LCD related manager configurations are a part of the manager's private data
in APPLY. Pass this to dss_lcd_mgr_config to dss_mgr_check and create a function
to check the validity of some of the configurations.
To check some of the configurations, we require information of interface to
which the manager output is connected. These can be added once interfaces are
represented as an entity.
Signed-off-by: Archit Taneja <archit@ti.com>
Replace the DISPC fuctions used to configure LCD channel related manager
parameters with dss_mgr_set_lcd_config() in APPLY. This function ensures that
the DISPC registers are written at the right time by using the shadow register
programming model.
The LCD manager configurations is stored as a private data of manager in APPLY.
It is treated as an extra info as it's the panel drivers which trigger this
apply via interface drivers, and not a DSS2 user like omapfb or omapdrm.
Storing LCD manager related properties in APPLY also prevents the need to refer
to the panel connected to the manager for information. This helps in making the
DSS driver less dependent on panel.
A helper function is added to check whether the manager is LCD or TV. The direct
DISPC register writes are removed from the interface drivers.
Signed-off-by: Archit Taneja <archit@ti.com>
Create a dss_lcd_mgr_config struct instance in SDI. Fill up all the parameters
of the struct with configurations held by the panel, and the configurations
required by SDI.
Use these to write to the DISPC registers. These direct register writes would be
later replaced by a function which applies the configuration using the shadow
register programming model.
Create function sdi_config_lcd_manager() which fills the mgr_config parameters
and writes to the DISPC registers.
Signed-off-by: Archit Taneja <archit@ti.com>
Create a dss_lcd_mgr_config struct instance in DSI. Fill up all the parameters
of the struct with configurations held by the panel, and the configurations
required by DSI.
Use these to write to the DISPC registers. These direct register writes would be
later replaced by a function which applies the configuration using the shadow
register programming model.
The function dsi_configure_dispc_clocks() is now called in
dsi_display_init_dispc(), this lets all the lcd manager related configurations
happen in the same place. The DISPC_DIVISORo register was written in
dsi_configure_dispc_clock(), now it just fills up the dispc_clock_info parameter
in mgr_config. The clock_info is written later in dsi_display_init_dispc().
Signed-off-by: Archit Taneja <archit@ti.com>
Create a dss_lcd_mgr_config struct instance in RFBI. Fill up all the parameters
of the struct with configurations held by the panel, and the configurations
required by RFBI.
Use these to write to the DISPC registers. These direct register writes would be
later replaced by a function which applies the configuration using the shadow
register programming model.
Create function rfbi_config_lcd_manager() which fills up the mgr_config
parameters and writes to the DISPC regs.
Signed-off-by: Archit Taneja <archit@ti.com>
Create a dss_lcd_mgr_config struct instance in DPI. Fill up all the parameters
of the struct with configurations held by the panel, and the configurations
required by DPI.
Use these to write to the DISPC registers. These direct register writes would be
later replaced by a function which applies the configuration using the shadow
register programming model.
The DISPC_DIVISORo registers were written in the functions dpi_set_dispc_clk()
and dpi_set_dsi_clk(), now they just fill up the dispc_clock_info parameter in
mgr_config. They are written later in dpi_config_lcd_manager.
Signed-off-by: Archit Taneja <archit@ti.com>
Create a struct dss_lcd_mgr_config which holds LCD overlay manager related
parameters. These are currently partially contained in the omap_dss_device
connected to the manager, and the rest are in the interface driver.
The parameters are directly written to the DISPC registers in the interface
drivers. These should eventually be applied at the correct time using the
shadow register programming model. This struct would help in grouping these
parameters so that they can be applied together.
Signed-off-by: Archit Taneja <archit@ti.com>
dipsc_mgr_set_clock div has an int return type to report errors or success.
The function doesn't really check for errors and always returns 0. Change
the return type to void.
Checking for the correct DISPC clock divider ranges will be done when a DSS2
user does a manager apply. This support will be added later.
Signed-off-by: Archit Taneja <archit@ti.com>
For DSI operation in videomode, DISPC logic levels for the signals HSYNC, VSYNC
and DE need to be specified to DSI via the fields VP_HSYNC_POL, VP_VSYNC_POL and
VP_DE_POL in DSI_CTRL registers.
This information is completely internal to DSS as logic levels for the above
signals hold no meaning on the DSI bus. Hence a DSI panel driver should be
totally oblivious of these fields.
Fix the logic levels/polarities in the DISPC and DSI registers to a default
value. This is done by overriding these fields in omap_video_timings struct
filled by the panel driver for DISPC, and use the equivalent default values
when programming DSI_CTRL registers. Also, remove the redundant polarity related
fields in omap_dss_dsi_videomode_data.
Signed-off-by: Archit Taneja <archit@ti.com>
The hdmi CEA and VESA timings were represented by the struct hdmi_video_timings,
omap_video_timings couldn't be used as it didn't contain the fields hsync/vsync
polarities and interlaced/progressive information.
Remove hdmi_video_timings, and use omap_video_timings instead.
Cc: Mythri P K <mythripk@ti.com>
Signed-off-by: Archit Taneja <archit@ti.com>
Use the interlace field in omap_video_timings to configure/retrieve
corresponding fb mode flags in fb_var_screeninfo and fb_videomode.
The interlace field maps with the fb mode flags FB_VMODE_INTERLACED and
FB_VMODE_NONINTERLACED.
Signed-off-by: Archit Taneja <archit@ti.com>
Currently the interlace parameter passed to dispc_ovl_setup() is configured by
checking the display type, and set to true if the display type is VENC.
This isn't correct as other panels can take interlaced content too. The
omap_video_timings struct in manager's private data contains the info whether
the panel is in interlaced mode or not.
Signed-off-by: Archit Taneja <archit@ti.com>
Add a parameter called interlace which tells whether the timings are in
interlaced or progressive mode. This aligns the omap_video_timings struct with
the Xorg modeline configuration.
It also removes the hack needed to write to divide the manager height by 2 if
the connected interface is VENC.
Signed-off-by: Archit Taneja <archit@ti.com>
omap_panel_config contains fields which are finally written to DISPC_POL_FREQo
registers. These are now held by omap_video_timings and are set when the manager
timings are applied.
Remove the omap_panel_config enum, and remove all it's references from panel or
interface drivers.
Signed-off-by: Archit Taneja <archit@ti.com>
Use the newly added fields in omap_video_timings(hsync, vsync and data_enable
logic levels and data, hsync and vsync latching related info) to
configure/retrieve corresponding sync flags in fb_var_screeninfo and
fb_videomode.
Out of the new fields, hsync_level and vsync_level can be mapped to the fb sync
flags FB_SYNC_HOR_HIGH_ACT and FB_SYNC_VERT_HIGH_ACT.
When converting fb mode to omap_video_timings, the fields which don't have an
equivalent parameter in fb are kept as the original values if the panel driver
has a get_timings op, else they are set to default values.
Signed-off-by: Archit Taneja <archit@ti.com>
dispc_mgr_set_pol_freq() configures the fields in the register DISPC_POL_FREQo.
All these fields have been moved to omap_video_timings struct, and are now
programmed in dispc_mgr_set_lcd_timings(). These will be configured when timings
are applied via dss_mgr_set_timings().
Remove dispc_mgr_set_pol_freq() and it's calls from the interface drivers.
Signed-off-by: Archit Taneja <archit@ti.com>
Hsync, Vsync, Data enable enable logic levels and latching info of Data lanes,
Hsync and Vsync signals(with respect to pixel clock) are newly added parameters
in omap_video_timings.
Program these in dispc_mgr_set_lcd_timings. These will be configured when the
manager's timings are set via dss_mgr_set_timings().
Signed-off-by: Archit Taneja <archit@ti.com>
The display sysfs file for viewing/storing display timings is something which
will be deprecated. The new omap_video_timings fields (hsync_level, vsync_level
and others) are not configurable or viewable via this sysfs file.
This prevents the need to make the input more configurable to take the new
fields and at the same time work without these fields for backward
compatibility.
In display_timings_store, the omap_video_timings struct used to set the timings
is initialized to the existing panel timings so that the new fields are taken in
correctly. The other fields are taken from the user as before.
Signed-off-by: Archit Taneja <archit@ti.com>
Some panel timing related fields are contained in omap_panel_config in the form
of flags. The fields are:
- Hsync logic level
- Vsync logic level
- Data driven on rising/falling edge of pixel clock
- Output enable/Data enable logic level
- HSYNC/VSYNC driven on rising/falling edge of pixel clock
Out of these parameters, Hsync and Vsync logic levels are a part of the timings
in the Xorg modeline configuration. So it makes sense to move the to
omap_video_timings. The rest aren't a part of modeline, but it still makes
sense to move these since they are related to panel timings.
These fields stored in omap_panel_config in dssdev are configured for LCD
panels, and the corresponding LCD managers in the DISPC_POL_FREQo registers.
Add the above fields in omap_video_timings. Represent their state via new enums.
Add these parameters to the omap_video_timings instances in the panel drivers.
Keep the corresponding IVS, IHS, IPC, IEO, RF and ONOFF flags in
omap_panel_config for now. The struct will be removed later.
Signed-off-by: Archit Taneja <archit@ti.com>
Remove configuration of Ac-bias pins
Ac-bias pins need to be configured only for passive matrix displays. Remove
acbi and acb fields in omap_dss_device and their configuration in panel
drivers. Don't program these fields in DISP_POL_FREQo register any more.
The panel driver for sharp-ls037v7dw01, and the panel config for
Innolux AT070TN8 in generic dpi panel driver set acb to a non zero value. This
is most likely carried over from the old omapfb driver which supported passive
matrix displays.
Cc: Thomas Weber <weber@corscience.de>
Signed-off-by: Archit Taneja <archit@ti.com>
Remove omap_lcd_display_type enum
The enum omap_lcd_display_type is used to configure the lcd display type in
DISPC. Remove this enum and always set display type to TFT by creating function
dss_mgr_set_lcd_type_tft().
Signed-off-by: Archit Taneja <archit@ti.com>
Remove OMAP_DSS_LCD_TFT as a omap_panel_config flag.
We don't support passive matrix displays any more. Remove this flag from all the
panel drivers.
Force the display_type to OMAP_DSS_LCD_DISPLAY_TFT in the interface drivers.
Signed-off-by: Archit Taneja <archit@ti.com>
Remove clock constraints related to passive matrix displays.
There is a constraint (pcd_min should be 3) for passive matrix displays. Remove
this constraint in clock divider calculations as we won't support passive
matrix displays any more.
This cleans up the functions which calculate the clock dividers with DSI's PLL
or DSS_FCLK as the clock source.
Signed-off-by: Archit Taneja <archit@ti.com>
State change of HDMI PHY could potentially take many millisecs, we can do
better by protecting things in hdmi_set_phy_pwr() with a mutex rather than
a spin_lock_irqsave.
Signed-off-by: Jassi Brar <jaswinder.singh@linaro.org>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
It is simpler to read the current status from a register as compared
to maintaining a state variable to hold the information.
Signed-off-by: Jassi Brar <jaswinder.singh@linaro.org>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
DISPC functions have been modified to provide clock and register dumps and debug
support for the LCD3 manager.
Signed-off-by: Chandrabhanu Mahapatra <cmahapatra@ti.com>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
The support for LCD3 manager has been added into the manager module. LCD3 panel
has registers as DISPC_CONTROL3 and DISPC_CONFIG3 just like those in LCD and
LCD2 panels. These registers control the Display Controller (DISPC) module for
LCD3 output. The three LCDs support Display Serial Interface (DSI), Remote Frame
Buffer Interface (RFBI) and Parallel CMOS Output Interface (DPI). These LCDs can
be connected through parallel output interface using DISPC and RFBI or DPI. For
serial interface DSS uses DSI.
The LCD3 panel, just like LCD and LCD2 panels, has a clock switch in DSS_CTRL
register which has been enabled. The clock switch chooses between DSS_CLK and
DPLL_DSI1_C_CLK1 as source for LCD3_CLK. New IRQs as DISPC_IRQ_VSYNC3,
DISPC_IRQ_FRAMEDONE3, DISPC_IRQ_ACBIAS_COUNT_STAT3 and DISPC_IRQ_SYNC_LOST3 have
been added specific to the new manager.
Signed-off-by: Chandrabhanu Mahapatra <cmahapatra@ti.com>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
OMAP5 Display Subsystem (DSS) architecture comes with a additional LCD3 channel
with its own dedicated overlay manager. The current patch adds LCD3 channel and
basic register support for LCD3 channel. It adds register addresses for various
Display Controller (DISPC) registers like DISPC_DEFAULT_COLOR, DISPC_TIMING_H,
DISPC_DIVISORo, etc.
Signed-off-by: Chandrabhanu Mahapatra <cmahapatra@ti.com>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
The current implementation of LCD channels and managers consists of a number of
if-else construct which has been replaced by a simpler interface. A constant
structure mgr_desc has been created in Display Controller (DISPC) module. The
mgr_desc contains for each channel its name, irqs and is initialized one time
with all registers and their corresponding fields to be written to enable
various features of Display Subsystem. This structure is later used by various
functions of DISPC which simplifies the further implementation of LCD channels
and its corresponding managers.
Signed-off-by: Chandrabhanu Mahapatra <cmahapatra@ti.com>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
If runtime PM is not enabled in the kernel config, pm_runtime_get_sync()
will always return 1 and pm_runtime_put_sync() will always return
-ENOSYS. pm_runtime_get_sync() returning 1 presents no problem to the
driver, but -ENOSYS from pm_runtime_put_sync() causes the driver to
print a warning.
One option would be to ignore errors returned by pm_runtime_put_sync()
totally, as they only say that the call was unable to put the hardware
into suspend mode.
However, I chose to ignore the returned -ENOSYS explicitly, and print a
warning for other errors, as I think we should get notified if the HW
failed to go to suspend properly.
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
Cc: Jassi Brar <jaswinder.singh@linaro.org>
Cc: Grazvydas Ignotas <notasas@gmail.com>
The current way how omapdss handles system suspend and resume is that
omapdss device (a platform device, which is not part of the device
hierarchy of the DSS HW devices, like DISPC and DSI, or panels.) uses
the suspend and resume callbacks from platform_driver to handle system
suspend. It does this by disabling all enabled panels on suspend, and
resuming the previously disabled panels on resume.
This presents a few problems.
One is that as omapdss device is not related to the panel devices or the
DSS HW devices, there's no ordering in the suspend process. This means
that suspend could be first ran for DSS HW devices and panels, and only
then for omapdss device. Currently this is not a problem, as DSS HW
devices and panels do not handle suspend.
Another, more pressing problem, is that when suspending or resuming, the
runtime PM functions return -EACCES as runtime PM is disabled during
system suspend. This causes the driver to print warnings, and operations
to fail as they think that they failed to bring up the HW.
This patch changes the omapdss suspend handling to use PM notifiers,
which are called before suspend and after resume. This way we have a
normally functioning system when we are suspending and resuming the
panels.
This patch, I believe, creates a problem that somebody could enable or
disable a panel between PM_SUSPEND_PREPARE and the system suspend, and
similarly the other way around in resume. I choose to ignore the problem
for now, as it sounds rather unlikely, and if it happens, it's not
fatal.
In the long run the system suspend handling of omapdss and panels should
be thought out properly. The current approach feels rather hacky.
Perhaps the panel drivers should handle system suspend, or the users of
omapdss (omapfb, omapdrm) should handle system suspend.
Note that after this patch we could probably revert
0eaf9f52e9 (OMAPDSS: use sync versions of
pm_runtime_put). But as I said, this patch may be temporary, so let's
leave the sync version still in place.
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
Reported-by: Jassi Brar <jaswinder.singh@linaro.org>
Tested-by: Jassi Brar <jaswinder.singh@linaro.org>
In preparation of OMAP moving to Common Clk Framework(CCF) change
clk_enable() and clk_disable() calls to clk_prepare_enable() and
clk_disable_unprepare() in omapdss. This can be safely done, as omapdss
never enables or disables clocks in atomic context.
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
Cc: Tomi Valkeinen <tomi.valkeinen@ti.com>
Cc: <linux-fbdev@vger.kernel.org>
Cc: Paul Walmsley <paul@pwsan.com>
Cc: Mike Turquette <mturquette@linaro.org>
[tomi.valkeinen@ti.com: updated patch description]