If the caller does not pass a valid in_wc to process_mad(), return MAD
failure status, as it is not possible to generate a valid MAD redirect
response (and redirects are the only MAD responses ehca generates).
Signed-off-by: Alexander Schmidt <alexs@linux.vnet.ibm.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
The old code used a lot of hard-coded values, which might not be valid
in all environments (especially routed fabrics or partitioned
subnets). Copy as much information as possible from the incoming
request to correct that.
Signed-off-by: Joachim Fenkes <fenkes@de.ibm.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
The base versions handle constant folding just fine, use them
directly. The replacements are OK in the include/ files as they are
not exported to userspace so we don't need the __ prefixed versions.
This patch does not affect code generation at all.
Signed-off-by: Harvey Harrison <harvey.harrison@gmail.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
Commit fe333321 ("powerpc: Change u64/s64 to a long long integer
type") changed u64 from unsigned long to unsigned long long, which
means that printk formats for printing u64 values should use "ll"
instead of "l" to avoid warnings. Fix all the places affected by this
in ehca.
Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
This patch enables ehca to redirect any PMA queries to the
actual PMA QP.
Signed-off-by: Hoang-Nam Nguyen <hnguyen@de.ibm.com>
Reviewed-by: Joachim Fenkes <fenkes@de.ibm.com>
Reviewed-by: Christoph Raisch <raisch@de.ibm.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
This patch enhances ehca with a capability to "autodetect" the ports
being connected physically. In order to utilize that function the
module option nr_ports must be set to -1 (default is 2 - two
ports). This feature is experimental and will made the default later.
More detail:
If the user connects only one port to the switch, current code requires
1) port one to be connected and
2) module option nr_ports=1 to be given.
If autodetect is enabled, ehca will not wait at creation of the GSI QP
for the respective port to become active. Since firmware does not
accept modify_qp() while the port is down at initialization, we need
to cache all calls to modify_qp() for the SMI/GSI QP and just return a
good return code.
When a port is activated and we get a PORT_ACTIVE event, we replay the
cached modify-qp() parms and re-trigger any posted recv WRs. Only then
do we forward the PORT_ACTIVE event to registered clients.
The result of this autodetect patch is that all ports will be
accessible by the users. Depending on their respective cabling only
those ports that are connected properly will become operable. If a
user tries to modify a regular QP of a non-connected port, modify_qp()
will fail. Furthermore, ibv_devinfo should show the port state
accordingly.
Note that this patch primarily improves the loading behaviour of
ehca. If the cable is removed while the driver is operating and
plugged in again, firmware will handle that properly by sending an
appropriate async event.
Signed-off-by: Hoang-Nam Nguyen <hnguyen@de.ibm.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
Add a driver for IBM GX bus InfiniBand adapters, which are usable with
some pSeries/System p systems.
Signed-off-by: Heiko J Schick <schickhj.ibm.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>