If thermal bank with 4 sensors, thermal driver should read TEMP_MSR3.
However, currently thermal driver would not read TEMP_MSR3 since mt8173
thermal driver only use 3 sensors on each thermal bank at the same time,
so this patch would not effect temperature.
Only if mt mt8173 thermal driver use 4 sensors on any thermal bank, would
read third sensor two times, and lose fourth sensor of vale.
cc: stable@vger.kernel.org
Fixes: b7cf005373 ("thermal: Add Mediatek thermal driver for mt2701.")
Reviewed-by: Matthias Brugger <matthias.bgg@gmail.com>
Signed-off-by: Dawei Chien <dawei.chien@mediatek.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Sparse throws following warnings:
drivers/thermal/mtk_thermal.c:186:11: warning: symbol 'mt8173_bank_data' was not declared. Should it be static?
drivers/thermal/mtk_thermal.c:193:11: warning: symbol 'mt8173_msr' was not declared. Should it be static?
drivers/thermal/mtk_thermal.c:197:11: warning: symbol 'mt8173_adcpnp' was not declared. Should it be static?
drivers/thermal/mtk_thermal.c:201:11: warning: symbol 'mt8173_mux_values' was not declared. Should it be static?
drivers/thermal/mtk_thermal.c:204:11: warning: symbol 'mt2701_bank_data' was not declared. Should it be static?
drivers/thermal/mtk_thermal.c:208:11: warning: symbol 'mt2701_msr' was not declared. Should it be static?
drivers/thermal/mtk_thermal.c:212:11: warning: symbol 'mt2701_adcpnp' was not declared. Should it be static?
drivers/thermal/mtk_thermal.c:216:11: warning: symbol 'mt2701_mux_values' was not declared. Should it be static?
Make these variables as static to fix these warnings.
Signed-off-by: Vivek Gautam <vivek.gautam@codeaurora.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
devm_thermal_zone_of_sensor_register can fail, so check it's return value.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Reviewed-by: Matthias Brugger <matthias.bgg@gmail.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This patch adds support for mt2701 chip to mtk_thermal,
and integrate both mt8173 and mt2701 on the same driver.
MT8173 has four banks and five sensors, and MT2701 has
only one bank and three sensors.
Signed-off-by: Dawei Chien <dawei.chien@mediatek.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This adds support for the Mediatek thermal controller found on MT8173
and likely other SoCs.
The controller is a bit special. It does not have its own ADC, instead
it controls the on-SoC AUXADC via AHB bus accesses. For this reason
we need the physical address of the AUXADC. Also it controls a mux
using AHB bus accesses, so we need the APMIXEDSYS physical address aswell.
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>