Commit Graph

24 Commits

Author SHA1 Message Date
Sam Protsenko
6a734b3720 clk: samsung: clk-pll: Implement pll0831x PLL type
pll0831x PLL is used in Exynos850 SoC for top-level fractional PLLs. The
code was derived from very similar pll36xx type, with next differences:

1. Lock time for pll0831x is 500*P_DIV, when for pll36xx it's 3000*P_DIV
2. It's not suggested in Exynos850 TRM that S_DIV change doesn't require
   performing PLL lock procedure (which is done in pll36xx
   implementation)
3. The offset from PMS-values register to K-value register is 0x8 for
   pll0831x, when for pll36xx it's 0x4

When defining pll0831x type, CON3 register offset should be provided as
a "con" parameter of PLL() macro, like this:

    PLL(pll_0831x, 0, "fout_mmc_pll", "oscclk",
        PLL_LOCKTIME_PLL_MMC, PLL_CON3_PLL_MMC, pll0831x_26mhz_tbl),

To define PLL rates table, one can use PLL_36XX_RATE() macro, e.g.:

    PLL_36XX_RATE(26 * MHZ, 799999877, 31, 1, 0, -15124)

as it's completely appropriate for pl0831x type and there is no sense in
duplicating that.

If bit #1 (MANUAL_PLL_CTRL) is not set in CON1 register, it won't be
possible to set new rate, with next error showing in kernel log:

    Could not lock PLL fout_mmc_pll

That can happen for example if bootloader clears that bit beforehand.
PLL driver doesn't account for that, so if MANUAL_PLL_CTRL bit was
cleared, it's assumed it was done for a reason and it shouldn't be
possible to change that PLL's rate at all.

Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com>
Acked-by: Chanwoo Choi <cw00.choi@samsung.com>
Link: https://lore.kernel.org/r/20211008154352.19519-3-semen.protsenko@linaro.org
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
2021-10-09 22:21:04 +02:00
Sam Protsenko
8f90f43a09 clk: samsung: clk-pll: Implement pll0822x PLL type
pll0822x PLL is used in Exynos850 SoC for top-level integer PLLs. The
code was derived from very similar pll35xx type, with next differences:

1. Lock time for pll0822x is 150*P_DIV, when for pll35xx it's 270*P_DIV
2. It's not suggested in Exynos850 TRM that S_DIV change doesn't require
   performing PLL lock procedure (which is done in pll35xx
   implementation)

When defining pll0822x type, CON3 register offset should be provided as
a "con" parameter of PLL() macro, like this:

    PLL(pll_0822x, 0, "fout_shared0_pll", "oscclk",
        PLL_LOCKTIME_PLL_SHARED0, PLL_CON3_PLL_SHARED0,
        exynos850_shared0_pll_rates),

To define PLL rates table, one can use PLL_35XX_RATE() macro, e.g.:

    PLL_35XX_RATE(26 * MHZ, 1600 * MHZ, 800, 13, 0)

as it's completely appropriate for pl0822x type and there is no sense in
duplicating that.

If bit #1 (MANUAL_PLL_CTRL) is not set in CON1 register, it won't be
possible to set new rate, with next error showing in kernel log:

    Could not lock PLL fout_shared1_pll

That can happen for example if bootloader clears that bit beforehand.
PLL driver doesn't account for that, so if MANUAL_PLL_CTRL bit was
cleared, it's assumed it was done for a reason and it shouldn't be
possible to change that PLL's rate at all.

Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com>
Acked-by: Chanwoo Choi <cw00.choi@samsung.com>
Link: https://lore.kernel.org/r/20211008154352.19519-2-semen.protsenko@linaro.org
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
2021-10-09 22:19:58 +02:00
Thomas Gleixner
d2912cb15b treewide: Replace GPLv2 boilerplate/reference with SPDX - rule 500
Based on 2 normalized pattern(s):

  this program is free software you can redistribute it and or modify
  it under the terms of the gnu general public license version 2 as
  published by the free software foundation

  this program is free software you can redistribute it and or modify
  it under the terms of the gnu general public license version 2 as
  published by the free software foundation #

extracted by the scancode license scanner the SPDX license identifier

  GPL-2.0-only

has been chosen to replace the boilerplate/reference in 4122 file(s).

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Enrico Weigelt <info@metux.net>
Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org>
Reviewed-by: Allison Randal <allison@lohutok.net>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190604081206.933168790@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2019-06-19 17:09:55 +02:00
Andrzej Hajda
1d5013f1b6 clk: samsung: Add compile time PLL rate validators
Rates declared in PLL rate tables should match exactly rates calculated
from PLL coefficients. To avoid possible mistakes we can use compile
time validation.
The patch introduces such validators and expands all initializers
with additional input frequency parameter, required to validate rates.
Since S3C24xx PLLs requires different validators two new macros have
been introduced to deal with it. Also, since PLLs 4502 and 4508 have
different formulas PLL_45XX_RATE has been replaced with PLL_4508_RATE.

As the patch adds only compile time validators it should not have impact
on compiled code.

Signed-off-by: Andrzej Hajda <a.hajda@samsung.com>
Acked-by: Krzysztof Kozlowski <krzk@kernel.org>
Acked-by: Tomasz Figa <tomasz.figa@gmail.com>
Acked-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
2018-02-23 15:15:20 +01:00
Marek Szyprowski
9f57fd6ee4 clk: samsung: Remove dead code
samsung_clk_register_pll2550x() function is not used anymore,
so remove its declaration.

Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
Reviewed-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
2017-06-07 22:47:55 +02:00
Sylwester Nawrocki
be95d2c7d9 clk: samsung: Add support for EPLL on exynos5410
This patch adds code instantiating the EPLL, which is used as the
audio subsystem's root clock.
The requirement to specify the external root clock in clocks property
is documented.  Having the consumer 'clocks' property ensures proper
initialization order by explicitly specifying dependencies in DT.
It prevents situations when the SoC's clock controller driver has
initialized, the external oscillator clock is not yet registered
and setting clock frequencies through assigned-clock-rates property
doesn't work properly due to unknown external oscillator frequency.

Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Reviewed-by: Chanwoo Choi <cw00.choi@samsung.com>
2016-09-09 17:35:13 +02:00
Sylwester Nawrocki
1d9aa64c37 clk: samsung: Use common registration function for pll2550x
There is no such significant differences in pll2550x PLL type
to justify a separate registration function.  This patch adapts
exynos5440 driver to use the common function and removes
samsung_clk_register_pll2550x().

Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Reviewed-by: Chanwoo Choi <cw00.choi@samsung.com>
2016-09-09 17:35:10 +02:00
Naveen Krishna Ch
0c23e2af67 clk: samsung: add support for 145xx and 1460x PLLs
PLL145xx is similar to PLL35xx and PLL1460x is almost similar
to PLL46xx with minor differences in bit positions. Hence,
reuse the functions defined for pll_35xx and pll_46xx to
support 145xx and 1460x PLLs respectively.

Signed-off-by: Naveen Krishna Ch <naveenkrishna.ch@gmail.com>
Signed-off-by: Abhilash Kesavan <a.kesavan@samsung.com>
Reviewed-by: Thomas Abraham <thomas.ab@samsung.com>
Tested-by: Thomas Abraham <thomas.ab@samsung.com>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
2014-10-31 10:45:35 +01:00
Rahul Sharma
eefe119b81 clk/samsung: add support for pll2650xx
Add support for pll2650xx in samsung pll file. This PLL variant
is close to pll36xx but uses CON2 registers instead of CON1.

Aud_pll in Exynos5260 is pll2650xx and uses this code.

Signed-off-by: Rahul Sharma <rahul.sharma@samsung.com>
Reviewed-by: Pankaj Dubey <pankaj.dubey@samsung.com>
Signed-off-by: Tomasz Figa <t.figa@samsung.com>
2014-05-14 19:16:54 +02:00
Pankaj Dubey
8432984732 clk/samsung: add support for pll2550xx
exynos5260 use pll2550xx and it has different bit fields
for P,M,S values as compared to pll2550. Support for
pll2550xx is added here.

Signed-off-by: Pankaj Dubey <pankaj.dubey@samsung.com>
Signed-off-by: Rahul Sharma <rahul.sharma@samsung.com>
Signed-off-by: Arun Kumar K <arun.kk@samsung.com>
Signed-off-by: Tomasz Figa <t.figa@samsung.com>
2014-05-14 19:16:54 +02:00
Heiko Stuebner
ea5d6a8d3e clk: samsung: add plls used by the early s3c24xx cpus
The manuals do not give them explicit names like in later socs, so more
generic names with a s3c2410-prefix were used for them.

As it was common to do so in the previous implementation, functionality
to change the pll rate is already included.

Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Acked-by: Mike Turquette <mturquette@linaro.org>
Acked-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
2014-04-15 02:11:36 +09:00
Heiko Stuebner
a951b1d91d clk: samsung: add plls used by the s3c2443
The s3c2443 uses different plls that are not present yet. Therefore
add the two needed types.

Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Acked-by: Tomasz Figa <t.figa@samsung.com>
Acked-by: Mike Turquette <mturquette@linaro.org>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
2014-04-15 02:11:07 +09:00
Heiko Stuebner
06654acb66 clk: samsung: add pll_6552 variant for s3c2416
According to the manual s3c2416 and s3c2450 use a pll 6552 and 6553
and while the pll_6553 matches exactly the one already implemented
the pll_6552 differs to the one from the s3c64xx series.

The change is solely in the bit locations of the mdiv and pdiv values.
All calculations are the same for both implementatons and even the
proposed divider-values for specific frequencies in the manuals are
the same.

Therefore implement a variant that simply uses the changed bit
locations if necessary.

Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Acked-by: Tomasz Figa <t.figa@samsung.com>
Acked-by: Mike Turquette <mturquette@linaro.org>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
2014-04-15 02:11:07 +09:00
Tomasz Figa
5c89658a2e clk: samsung: pll: Add support for rate configuration of PLL46xx
This patch implements round_rate and set_rate callbacks of PLL46xx
driver to allow reconfiguration of PLL at runtime.

Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-09-06 13:33:47 -07:00
Tomasz Figa
c50d11f35a clk: samsung: pll: Use new registration method for PLL46xx
This patch modifies PLL46xx support code and its users to use the
recently introduced common PLL registration helper.

Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-09-06 13:33:43 -07:00
Tomasz Figa
b4054ac6a2 clk: samsung: pll: Add support for rate configuration of PLL45xx
This patch implements round_rate and set_rate callbacks of PLL45xx
driver to allow reconfiguration of PLL at runtime.

Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-09-06 13:33:39 -07:00
Tomasz Figa
52b0601637 clk: samsung: pll: Use new registration method for PLL45xx
This patch modifies PLL45xx support code and its users to use the
recently introduced common PLL registration helper.

Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-09-06 13:33:35 -07:00
Tomasz Figa
40ef723c8b clk: samsung: pll: Use new registration method for PLL6552 and PLL6553
This patch modifies PLL6552 and PLL6553 clock drivers to use recently
added common Samsung PLL registration method.

Signed-off-by: Tomasz Figa <tomasz.figa@gmail.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-08-26 18:09:56 -07:00
Mike Turquette
5cfe9614f3 Merge branch 'clk-next-s3c64xx' into clk-next 2013-08-08 15:57:26 -07:00
Tomasz Figa
eb5271215b clk: samsung: pll: Add support for PLL6552 and PLL6553
This patch adds support for PLL6552 and PLL6553 PLLs present on Samsung
S3C64xx SoCs.

Signed-off-by: Tomasz Figa <tomasz.figa@gmail.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-08-05 11:58:30 -07:00
Yadwinder Singh Brar
3ff6e0d8d6 clk: samsung: Add support to register rate_table for samsung plls
This patch defines a common rate_table which will contain recommended p, m, s,
k values for supported rates that needs to be changed for changing
corresponding PLL's rate.

Reviewed-by: Doug Anderson <dianders@chromium.org>
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-08-02 13:22:09 -07:00
Yadwinder Singh Brar
5ca8fbd8d1 clk: samsung: Remove unused pll registeration code for pll35xx and pll36xx
This patch removes samsung_clk_register_pll35xx() and
samsung_clk_register_pll36xx() registaration functions as users migrated to
new samsung_clk_register_pll().

Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-08-02 13:22:09 -07:00
Yadwinder Singh Brar
07dc76fa61 clk: samsung: Define a common samsung_clk_register_pll()
This patch defines a common samsung_clk_register_pll()
Since pll2550 & pll35xx and pll2650 & pll36xx have exactly same clk ops
implementation, added pll2550 and pll2650 also.

Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-08-02 13:19:18 -07:00
Thomas Abraham
1c4c5fe0b7 clk: samsung: add pll clock registration helper functions
There are several types of pll clocks used in Samsung SoC's and these
pll clocks can be represented as Samsung specific pll clock types and
registered with the common clock framework. Add support for pll35xx,
pll36xx, pll45xx, pll46xx and pll2550x clock types and helper functions
to register them.

Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Tested-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Reviewed-by: Tomasz Figa <t.figa@samsung.com>
Tested-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Thomas Abraham <thomas.abraham@linaro.org>
Acked-by: Mike Turquette <mturquette@linaro.org>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
2013-03-25 18:16:37 +09:00