Fixes this warning:
>> drivers/mtd/bcm63xxpart.c:175:4: note: in expansion of macro 'pr_err'
pr_err("invalid rootfs address: %*ph\n",
^
>> include/linux/kern_levels.h:4:18: warning: field width specifier '*' expects argument of type 'int', but argument 2 has type 'long unsigned int' [-Wformat=]
Reported-by: kbuild test robot <fengguang.wu@intel.com>
Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Move the NOR flash layout to a separate function to allow the NAND flash
layout to be supported.
Signed-off-by: Simon Arlott <simon@fire.lp0.eu>
Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Strings read from flash could be missing null termination characters, or
not contain valid integers.
Null terminate the strings and check for errors when converting them to
integers.
Also validate that the addresses are at least BCM963XX_EXTENDED_SIZE
because this will be subtracted from them.
Signed-off-by: Simon Arlott <simon@fire.lp0.eu>
Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Extract image tag reading and CRC check to a separate function.
Signed-off-by: Simon Arlott <simon@fire.lp0.eu>
Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Read nvram directly from flash instead of using the in-memory copy that
mach-bcm63xx has, to remove the dependency on mach-bcm63xx and allow the
parser to work on bmips too.
Rename remaining BCM63XX defines to BCM963XX as these are properties of
the flash layout on the board.
BCM963XX_DEFAULT_PSI_SIZE changes from SZ_64K to 64 because it will be
multiplied by SZ_1K later on.
Signed-off-by: Simon Arlott <simon@fire.lp0.eu>
Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Pull MIPS updates from Ralf Baechle:
"This is the main pull request for MIPS for 4.5 plus some 4.4 fixes.
The executive summary:
- ATH79 platform improvments, use DT bindings for the ATH79 USB PHY.
- Avoid useless rebuilds for zboot.
- jz4780: Add NEMC, BCH and NAND device tree nodes
- Initial support for the MicroChip's DT platform. As all the device
drivers are missing this is still of limited use.
- Some Loongson3 cleanups.
- The unavoidable whitespace polishing.
- Reduce clock skew when synchronizing the CPU cycle counters on CPU
startup.
- Add MIPS R6 fixes.
- Lots of cleanups across arch/mips as fallout from KVM.
- Lots of minor fixes and changes for IEEE 754-2008 support to the
FPU emulator / fp-assist software.
- Minor Ralink, BCM47xx and bcm963xx platform support improvments.
- Support SMP on BCM63168"
* 'upstream' of git://git.linux-mips.org/pub/scm/ralf/upstream-linus: (84 commits)
MIPS: zboot: Add support for serial debug using the PROM
MIPS: zboot: Avoid useless rebuilds
MIPS: BMIPS: Enable ARCH_WANT_OPTIONAL_GPIOLIB
MIPS: bcm63xx: nvram: Remove unused bcm63xx_nvram_get_psi_size() function
MIPS: bcm963xx: Update bcm_tag field image_sequence
MIPS: bcm963xx: Move extended flash address to bcm_tag header file
MIPS: bcm963xx: Move Broadcom BCM963xx image tag data structure
MIPS: bcm63xx: nvram: Use nvram structure definition from header file
MIPS: bcm963xx: Add Broadcom BCM963xx board nvram data structure
MAINTAINERS: Add KVM for MIPS entry
MIPS: KVM: Add missing newline to kvm_err()
MIPS: Move KVM specific opcodes into asm/inst.h
MIPS: KVM: Use cacheops.h definitions
MIPS: Break down cacheops.h definitions
MIPS: Use EXCCODE_ constants with set_except_vector()
MIPS: Update trap codes
MIPS: Move Cause.ExcCode trap codes to mipsregs.h
MIPS: KVM: Make kvm_mips_{init,exit}() static
MIPS: KVM: Refactor added offsetof()s
MIPS: KVM: Convert EXPORT_SYMBOL to _GPL
...
The extended flash address needs to be subtracted from bcm_tag flash
image offsets. Move this value to the bcm_tag header file.
Renamed define name to consistently use bcm963xx for flash layout
which should be considered a property of the board and not the SoC
(i.e. bcm63xx could theoretically be used on a board without CFE
or any flash).
Signed-off-by: Simon Arlott <simon@fire.lp0.eu>
Cc: David Woodhouse <dwmw2@infradead.org>
Cc: Brian Norris <computersforpeace@gmail.com>
Cc: Kevin Cernekee <cernekee@gmail.com>
Cc: Florian Fainelli <f.fainelli@gmail.com>
Cc: Jonas Gorski <jogo@openwrt.org>
Cc: Linux Kernel Mailing List <linux-kernel@vger.kernel.org>
Cc: MIPS Mailing List <linux-mips@linux-mips.org>
Cc: MTD Maling List <linux-mtd@lists.infradead.org>
Patchwork: https://patchwork.linux-mips.org/patch/11833/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
Move Broadcom BCM963xx image tag data structure to include/linux/
so that drivers outside of mach-bcm63xx can use it.
Signed-off-by: Simon Arlott <simon@fire.lp0.eu>
Cc: David Woodhouse <dwmw2@infradead.org>
Cc: Brian Norris <computersforpeace@gmail.com>
Cc: Kevin Cernekee <cernekee@gmail.com>
Cc: Florian Fainelli <f.fainelli@gmail.com>
Cc: Jonas Gorski <jogo@openwrt.org>
Cc: Linux Kernel Mailing List <linux-kernel@vger.kernel.org>
Cc: MIPS Mailing List <linux-mips@linux-mips.org>
Cc: MTD Maling List <linux-mtd@lists.infradead.org>
Patchwork: https://patchwork.linux-mips.org/patch/11832/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
We only want to modify these arrays inside the parser "drivers", so the
drivers should construct them however they like, then return them as
immutable arrays.
This will make other refactorings easier.
Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Reviewed-by: Boris Brezillon <boris.brezillon@free-electrons.com>
Most parsers can be handled with our new boilerplate-reducing macro.
There are a few that can't be (cmdlineparts and ofpart).
Also kill off the owner assignments, since register_mtd_parser() now
takes care of that.
Signed-off-by: Brian Norris <computersforpeace@gmail.com>
register_mtd_parser never fails; hence make it return void.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Read out the SPI size from nvram instead of defaulting to 64KiB — some
vendors actually use values larger than the "max" value of 64.
Signed-off-by: Jonas Gorski <jogo@openwrt.org>
Acked-by: Florian Fainelli <florian@openwrt.org>
Signed-off-by: Artem Bityutskiy <artem.bityutskiy@linux.intel.com>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
Use ll to be able to remove the casts.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Reviewed-by: Florian Fainelli <florian@openwrt.org>
Signed-off-by: Artem Bityutskiy <artem.bityutskiy@linux.intel.com>
The line belongs above the comment, not below it.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Reviewed-by: Florian Fainelli <florian@openwrt.org>
Signed-off-by: Artem Bityutskiy <artem.bityutskiy@linux.intel.com>
The CFE does not use 4K sectors even if the flash supports it, so
for the fixed partitions like CFE itself or NVRAM the erase block
size is always 64k or bigger.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Reviewed-by: Florian Fainelli <florian@openwrt.org>
Signed-off-by: Artem Bityutskiy <artem.bityutskiy@linux.intel.com>
The length of the spare part is calculated the same way in both branches
so move to a common place.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Reviewed-by: Florian Fainelli <florian@openwrt.org>
Signed-off-by: Artem Bityutskiy <artem.bityutskiy@linux.intel.com>
namelen is never used, so drop it.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Reviewed-by: Florian Fainelli <florian@openwrt.org>
Signed-off-by: Artem Bityutskiy <artem.bityutskiy@linux.intel.com>
The original Broadcom partition order has the root fs in front of the
kernel, which resulted in miscalculated partition sizes.
Detect when such an image is on the flash and also reorder the partitions
accordingly.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Acked-by: Florian Fainelli <florian@openwrt.org>
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@linux.intel.com>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
Only use the values from the image tag if it is valid. Always create
the CFE, NVRAM and linux partitions, to allow flashing a new image even
if the old is invalid without overwriting CFE or NVRAM.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@linux.intel.com>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
Instead of referencing the sizes of fixed partitions, use the
precomputed CFE/NVRAM lengths.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@linux.intel.com>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
The CFE boot loader on BCM63XX platforms assumes itself and the NVRAM
partition to be 64 KiB (or erase block sized, if larger).
Ensure this assumption is also met when creating the partitions to
prevent accidential erasure of CFE or NVRAM.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@linux.intel.com>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
Recent CFEs do not contain the CFE1CFE1 magic anymore, so check for the
"cfe-v" version marker string instead. As very old CFEs do not have
this string, leave the CFE1CFE1 magic as a fallback for detection.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@linux.intel.com>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
Recent BCM63XX devices support a variety of flash types (parallel, SPI,
NAND) and share the partition layout. To prevent code duplication make
the CFE partition parsing code a stand alone mtd parser to allow SPI or
NAND flash drivers to use it.
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
Acked-by: Florian Fainelli <florian@openwrt.org>
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@linux.intel.com>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>