KVM: s390: allow injecting all kinds of machine checks

Allow to specify CR14, logout area, external damage code
and failed storage address.

Since more then one machine check can be indicated to the guest at
a time we need to combine all indication bits with already pending
requests.

Signed-off-by: Jens Freimann <jfrei@linux.vnet.ibm.com>
Reviewed-by: Cornelia Huck <cornelia.huck@de.ibm.com>
Reviewed-by: David Hildenbrand <dahi@linux.vnet.ibm.com>
Signed-off-by: Christian Borntraeger <borntraeger@de.ibm.com>
This commit is contained in:
Jens Freimann 2014-08-13 10:09:04 +02:00 committed by Christian Borntraeger
parent 383d0b0501
commit fc2020cfe9

View File

@ -1063,11 +1063,19 @@ static int __inject_mchk(struct kvm_vcpu *vcpu, struct kvm_s390_irq *irq)
mchk->mcic, 2);
/*
* Combine mcic with previously injected machine checks and
* indicate them all together as described in the Principles
* of Operation, Chapter 11, Interruption action
* Because repressible machine checks can be indicated along with
* exigent machine checks (PoP, Chapter 11, Interruption action)
* we need to combine cr14, mcic and external damage code.
* Failing storage address and the logout area should not be or'ed
* together, we just indicate the last occurrence of the corresponding
* machine check
*/
mchk->cr14 |= irq->u.mchk.cr14;
mchk->mcic |= irq->u.mchk.mcic;
mchk->ext_damage_code |= irq->u.mchk.ext_damage_code;
mchk->failing_storage_address = irq->u.mchk.failing_storage_address;
memcpy(&mchk->fixed_logout, &irq->u.mchk.fixed_logout,
sizeof(mchk->fixed_logout));
if (mchk->mcic & MCHK_EX_MASK)
set_bit(IRQ_PEND_MCHK_EX, &li->pending_irqs);
else if (mchk->mcic & MCHK_REP_MASK)