bnxt_en: Improve logging of error recovery settings information.

We currently only log the error recovery settings if it is enabled.
In some cases, firmware disables error recovery after it was
initially enabled.  Without logging anything, the user will not be
aware of this change in setting.

Log it when error recovery is disabled.  Also, change the reset count
value from hexadecimal to decimal.

Reviewed-by: Edwin Peer <edwin.peer@broadcom.com>
Reviewed-by: Pavan Chebbi <pavan.chebbi@broadcom.com>
Signed-off-by: Michael Chan <michael.chan@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Michael Chan 2021-02-14 18:05:01 -05:00 committed by David S. Miller
parent df97b34d3a
commit f4d95c3c19

View File

@ -2055,14 +2055,11 @@ static int bnxt_async_event_process(struct bnxt *bp,
fw_health->enabled = EVENT_DATA1_RECOVERY_ENABLED(data1);
fw_health->master = EVENT_DATA1_RECOVERY_MASTER_FUNC(data1);
if (!fw_health->enabled)
break;
if (!fw_health->enabled) {
netif_info(bp, drv, bp->dev,
"Error recovery info: error recovery[%d], master[%d], reset count[0x%x], health status: 0x%x\n",
fw_health->enabled, fw_health->master,
bnxt_fw_health_readl(bp, BNXT_FW_RESET_CNT_REG),
bnxt_fw_health_readl(bp, BNXT_FW_HEALTH_REG));
"Error recovery info: error recovery[0]\n");
break;
}
fw_health->tmr_multiplier =
DIV_ROUND_UP(fw_health->polling_dsecs * HZ,
bp->current_interval * 10);
@ -2071,6 +2068,10 @@ static int bnxt_async_event_process(struct bnxt *bp,
bnxt_fw_health_readl(bp, BNXT_FW_HEARTBEAT_REG);
fw_health->last_fw_reset_cnt =
bnxt_fw_health_readl(bp, BNXT_FW_RESET_CNT_REG);
netif_info(bp, drv, bp->dev,
"Error recovery info: error recovery[1], master[%d], reset count[%u], health status: 0x%x\n",
fw_health->master, fw_health->last_fw_reset_cnt,
bnxt_fw_health_readl(bp, BNXT_FW_HEALTH_REG));
goto async_event_process_exit;
}
case ASYNC_EVENT_CMPL_EVENT_ID_DEBUG_NOTIFICATION: