mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-11-15 08:14:15 +08:00
thermal/drivers/cpufreq_cooling: Use device name instead of auto-numbering
Currently the naming of a cooling device is just a cooling technique followed by a number. When there are multiple cooling devices using the same technique, it is impossible to clearly identify the related device as this one is just a number. For instance: thermal-cpufreq-0 thermal-cpufreq-1 etc ... The 'thermal' prefix is redundant with the subsystem namespace. This patch removes the 'thermal' prefix and changes the number by the device name. So the naming above becomes: cpufreq-cpu0 cpufreq-cpu4 etc ... Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Link: https://lore.kernel.org/r/20210314111333.16551-2-daniel.lezcano@linaro.org
This commit is contained in:
parent
5848376181
commit
ef37d1f9ac
@ -13,10 +13,10 @@
|
||||
#include <linux/cpu.h>
|
||||
#include <linux/cpufreq.h>
|
||||
#include <linux/cpu_cooling.h>
|
||||
#include <linux/device.h>
|
||||
#include <linux/energy_model.h>
|
||||
#include <linux/err.h>
|
||||
#include <linux/export.h>
|
||||
#include <linux/idr.h>
|
||||
#include <linux/pm_opp.h>
|
||||
#include <linux/pm_qos.h>
|
||||
#include <linux/slab.h>
|
||||
@ -50,8 +50,6 @@ struct time_in_idle {
|
||||
|
||||
/**
|
||||
* struct cpufreq_cooling_device - data for cooling device with cpufreq
|
||||
* @id: unique integer value corresponding to each cpufreq_cooling_device
|
||||
* registered.
|
||||
* @last_load: load measured by the latest call to cpufreq_get_requested_power()
|
||||
* @cpufreq_state: integer value representing the current state of cpufreq
|
||||
* cooling devices.
|
||||
@ -69,7 +67,6 @@ struct time_in_idle {
|
||||
* cpufreq_cooling_device.
|
||||
*/
|
||||
struct cpufreq_cooling_device {
|
||||
int id;
|
||||
u32 last_load;
|
||||
unsigned int cpufreq_state;
|
||||
unsigned int max_level;
|
||||
@ -82,7 +79,6 @@ struct cpufreq_cooling_device {
|
||||
struct freq_qos_request qos_req;
|
||||
};
|
||||
|
||||
static DEFINE_IDA(cpufreq_ida);
|
||||
static DEFINE_MUTEX(cooling_list_lock);
|
||||
static LIST_HEAD(cpufreq_cdev_list);
|
||||
|
||||
@ -528,11 +524,11 @@ __cpufreq_cooling_register(struct device_node *np,
|
||||
{
|
||||
struct thermal_cooling_device *cdev;
|
||||
struct cpufreq_cooling_device *cpufreq_cdev;
|
||||
char dev_name[THERMAL_NAME_LENGTH];
|
||||
unsigned int i;
|
||||
struct device *dev;
|
||||
int ret;
|
||||
struct thermal_cooling_device_ops *cooling_ops;
|
||||
char *name;
|
||||
|
||||
dev = get_cpu_device(policy->cpu);
|
||||
if (unlikely(!dev)) {
|
||||
@ -567,16 +563,6 @@ __cpufreq_cooling_register(struct device_node *np,
|
||||
/* max_level is an index, not a counter */
|
||||
cpufreq_cdev->max_level = i - 1;
|
||||
|
||||
ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL);
|
||||
if (ret < 0) {
|
||||
cdev = ERR_PTR(ret);
|
||||
goto free_idle_time;
|
||||
}
|
||||
cpufreq_cdev->id = ret;
|
||||
|
||||
snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
|
||||
cpufreq_cdev->id);
|
||||
|
||||
cooling_ops = &cpufreq_cooling_ops;
|
||||
|
||||
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
|
||||
@ -591,7 +577,7 @@ __cpufreq_cooling_register(struct device_node *np,
|
||||
pr_err("%s: unsorted frequency tables are not supported\n",
|
||||
__func__);
|
||||
cdev = ERR_PTR(-EINVAL);
|
||||
goto remove_ida;
|
||||
goto free_idle_time;
|
||||
}
|
||||
|
||||
ret = freq_qos_add_request(&policy->constraints,
|
||||
@ -601,11 +587,18 @@ __cpufreq_cooling_register(struct device_node *np,
|
||||
pr_err("%s: Failed to add freq constraint (%d)\n", __func__,
|
||||
ret);
|
||||
cdev = ERR_PTR(ret);
|
||||
goto remove_ida;
|
||||
goto free_idle_time;
|
||||
}
|
||||
|
||||
cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev,
|
||||
cdev = ERR_PTR(-ENOMEM);
|
||||
name = kasprintf(GFP_KERNEL, "cpufreq-%s", dev_name(dev));
|
||||
if (!name)
|
||||
goto remove_qos_req;
|
||||
|
||||
cdev = thermal_of_cooling_device_register(np, name, cpufreq_cdev,
|
||||
cooling_ops);
|
||||
kfree(name);
|
||||
|
||||
if (IS_ERR(cdev))
|
||||
goto remove_qos_req;
|
||||
|
||||
@ -617,8 +610,6 @@ __cpufreq_cooling_register(struct device_node *np,
|
||||
|
||||
remove_qos_req:
|
||||
freq_qos_remove_request(&cpufreq_cdev->qos_req);
|
||||
remove_ida:
|
||||
ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
|
||||
free_idle_time:
|
||||
free_idle_time(cpufreq_cdev);
|
||||
free_cdev:
|
||||
@ -712,7 +703,6 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
||||
|
||||
thermal_cooling_device_unregister(cdev);
|
||||
freq_qos_remove_request(&cpufreq_cdev->qos_req);
|
||||
ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
|
||||
free_idle_time(cpufreq_cdev);
|
||||
kfree(cpufreq_cdev);
|
||||
}
|
||||
|
Loading…
Reference in New Issue