OMAP1: PM: register notifiers with generic clock ops even when !PM_RUNTIME

When runtime PM is disabled, device clocks need to be enabled on
device add and disabled on device remove.  This currently is not
happening because in the !PM_RUNTIME case, no notifiers are registered
for OMAP1 devices.

Fix this by ensuring notifiers are registered, even in the !PM_RUNTIME case.

Reported-by: Janusz Krzysztofik <jkrzyszt@tis.icnet.pl>
Tested-by: Janusz Krzysztofik <jkrzyszt@tis.icnet.pl>
Signed-off-by: Kevin Hilman <khilman@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
This commit is contained in:
Kevin Hilman 2011-06-14 05:53:18 -07:00 committed by Tony Lindgren
parent 2c53b436a3
commit e9e35c5a2b
2 changed files with 8 additions and 4 deletions

View File

@ -4,14 +4,14 @@
# Common support
obj-y := io.o id.o sram.o time.o irq.o mux.o flash.o serial.o devices.o dma.o
obj-y += clock.o clock_data.o opp_data.o reset.o
obj-y += clock.o clock_data.o opp_data.o reset.o pm_bus.o
obj-$(CONFIG_OMAP_MCBSP) += mcbsp.o
obj-$(CONFIG_OMAP_32K_TIMER) += timer32k.o
# Power Management
obj-$(CONFIG_PM) += pm.o sleep.o pm_bus.o
obj-$(CONFIG_PM) += pm.o sleep.o
# DSP
obj-$(CONFIG_OMAP_MBOX_FWK) += mailbox_mach.o

View File

@ -56,9 +56,13 @@ static struct dev_power_domain default_power_domain = {
USE_PLATFORM_PM_SLEEP_OPS
},
};
#define OMAP1_PWR_DOMAIN (&default_power_domain)
#else
#define OMAP1_PWR_DOMAIN NULL
#endif /* CONFIG_PM_RUNTIME */
static struct pm_clk_notifier_block platform_bus_notifier = {
.pwr_domain = &default_power_domain,
.pwr_domain = OMAP1_PWR_DOMAIN,
.con_ids = { "ick", "fck", NULL, },
};
@ -72,4 +76,4 @@ static int __init omap1_pm_runtime_init(void)
return 0;
}
core_initcall(omap1_pm_runtime_init);
#endif /* CONFIG_PM_RUNTIME */