ARM: dts: imx6dl: Add missing cooling device properties for CPUs
The cooling device properties "#cooling-cells" should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Signed-off-by: Anson Huang <Anson.Huang@nxp.com> Signed-off-by: Shawn Guo <shawnguo@kernel.org>
This commit is contained in:
parent
b533323760
commit
def76ebc7c
@ -64,6 +64,7 @@
|
||||
396000 1175000
|
||||
>;
|
||||
clock-latency = <61036>; /* two CLK32 periods */
|
||||
#cooling-cells = <2>;
|
||||
clocks = <&clks IMX6QDL_CLK_ARM>,
|
||||
<&clks IMX6QDL_CLK_PLL2_PFD2_396M>,
|
||||
<&clks IMX6QDL_CLK_STEP>,
|
||||
|