[SCSI] lpfc 8.3.0 : Rework RSCN netlink event to send entire RSCN payload
Rework RSCN netlink event to send entire RSCN payload Also replaces (SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX) with LPFC_NL_VENDOR_ID Signed-off-by: James Smart <James.Smart@emulex.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
This commit is contained in:
parent
5cd3bbfad0
commit
ddcc50f0f3
@ -3886,6 +3886,49 @@ lpfc_rscn_recovery_check(struct lpfc_vport *vport)
|
||||
return 0;
|
||||
}
|
||||
|
||||
/**
|
||||
* lpfc_send_rscn_event: Send an RSCN event to management application.
|
||||
* @vport: pointer to a host virtual N_Port data structure.
|
||||
* @cmdiocb: pointer to lpfc command iocb data structure.
|
||||
*
|
||||
* lpfc_send_rscn_event sends an RSCN netlink event to management
|
||||
* applications.
|
||||
*/
|
||||
static void
|
||||
lpfc_send_rscn_event(struct lpfc_vport *vport,
|
||||
struct lpfc_iocbq *cmdiocb)
|
||||
{
|
||||
struct lpfc_dmabuf *pcmd;
|
||||
struct Scsi_Host *shost = lpfc_shost_from_vport(vport);
|
||||
uint32_t *payload_ptr;
|
||||
uint32_t payload_len;
|
||||
struct lpfc_rscn_event_header *rscn_event_data;
|
||||
|
||||
pcmd = (struct lpfc_dmabuf *) cmdiocb->context2;
|
||||
payload_ptr = (uint32_t *) pcmd->virt;
|
||||
payload_len = be32_to_cpu(*payload_ptr & ~ELS_CMD_MASK);
|
||||
|
||||
rscn_event_data = kmalloc(sizeof(struct lpfc_rscn_event_header) +
|
||||
payload_len, GFP_KERNEL);
|
||||
if (!rscn_event_data) {
|
||||
lpfc_printf_vlog(vport, KERN_ERR, LOG_ELS,
|
||||
"0147 Failed to allocate memory for RSCN event\n");
|
||||
return;
|
||||
}
|
||||
rscn_event_data->event_type = FC_REG_RSCN_EVENT;
|
||||
rscn_event_data->payload_length = payload_len;
|
||||
memcpy(rscn_event_data->rscn_payload, payload_ptr,
|
||||
payload_len);
|
||||
|
||||
fc_host_post_vendor_event(shost,
|
||||
fc_get_event_number(),
|
||||
sizeof(struct lpfc_els_event_header) + payload_len,
|
||||
(char *)rscn_event_data,
|
||||
LPFC_NL_VENDOR_ID);
|
||||
|
||||
kfree(rscn_event_data);
|
||||
}
|
||||
|
||||
/**
|
||||
* lpfc_els_rcv_rscn: Process an unsolicited rscn iocb.
|
||||
* @vport: pointer to a host virtual N_Port data structure.
|
||||
@ -3933,6 +3976,10 @@ lpfc_els_rcv_rscn(struct lpfc_vport *vport, struct lpfc_iocbq *cmdiocb,
|
||||
"0214 RSCN received Data: x%x x%x x%x x%x\n",
|
||||
vport->fc_flag, payload_len, *lp,
|
||||
vport->fc_rscn_id_cnt);
|
||||
|
||||
/* Send an RSCN event to the management application */
|
||||
lpfc_send_rscn_event(vport, cmdiocb);
|
||||
|
||||
for (i = 0; i < payload_len/sizeof(uint32_t); i++)
|
||||
fc_host_post_event(shost, fc_get_event_number(),
|
||||
FCH_EVT_RSCN, lp[i]);
|
||||
@ -5128,7 +5175,7 @@ lpfc_send_els_failure_event(struct lpfc_hba *phba,
|
||||
fc_get_event_number(),
|
||||
sizeof(lsrjt_event),
|
||||
(char *)&lsrjt_event,
|
||||
SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX);
|
||||
LPFC_NL_VENDOR_ID);
|
||||
return;
|
||||
}
|
||||
if ((rspiocbp->iocb.ulpStatus == IOSTAT_NPORT_BSY) ||
|
||||
@ -5146,7 +5193,7 @@ lpfc_send_els_failure_event(struct lpfc_hba *phba,
|
||||
fc_get_event_number(),
|
||||
sizeof(fabric_event),
|
||||
(char *)&fabric_event,
|
||||
SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX);
|
||||
LPFC_NL_VENDOR_ID);
|
||||
return;
|
||||
}
|
||||
|
||||
@ -5164,32 +5211,68 @@ lpfc_send_els_failure_event(struct lpfc_hba *phba,
|
||||
static void
|
||||
lpfc_send_els_event(struct lpfc_vport *vport,
|
||||
struct lpfc_nodelist *ndlp,
|
||||
uint32_t cmd)
|
||||
uint32_t *payload)
|
||||
{
|
||||
struct lpfc_els_event_header els_data;
|
||||
struct lpfc_els_event_header *els_data = NULL;
|
||||
struct lpfc_logo_event *logo_data = NULL;
|
||||
struct Scsi_Host *shost = lpfc_shost_from_vport(vport);
|
||||
|
||||
els_data.event_type = FC_REG_ELS_EVENT;
|
||||
switch (cmd) {
|
||||
if (*payload == ELS_CMD_LOGO) {
|
||||
logo_data = kmalloc(sizeof(struct lpfc_logo_event), GFP_KERNEL);
|
||||
if (!logo_data) {
|
||||
lpfc_printf_vlog(vport, KERN_ERR, LOG_ELS,
|
||||
"0148 Failed to allocate memory "
|
||||
"for LOGO event\n");
|
||||
return;
|
||||
}
|
||||
els_data = &logo_data->header;
|
||||
} else {
|
||||
els_data = kmalloc(sizeof(struct lpfc_els_event_header),
|
||||
GFP_KERNEL);
|
||||
if (!els_data) {
|
||||
lpfc_printf_vlog(vport, KERN_ERR, LOG_ELS,
|
||||
"0149 Failed to allocate memory "
|
||||
"for ELS event\n");
|
||||
return;
|
||||
}
|
||||
}
|
||||
els_data->event_type = FC_REG_ELS_EVENT;
|
||||
switch (*payload) {
|
||||
case ELS_CMD_PLOGI:
|
||||
els_data.subcategory = LPFC_EVENT_PLOGI_RCV;
|
||||
els_data->subcategory = LPFC_EVENT_PLOGI_RCV;
|
||||
break;
|
||||
case ELS_CMD_PRLO:
|
||||
els_data.subcategory = LPFC_EVENT_PRLO_RCV;
|
||||
els_data->subcategory = LPFC_EVENT_PRLO_RCV;
|
||||
break;
|
||||
case ELS_CMD_ADISC:
|
||||
els_data.subcategory = LPFC_EVENT_ADISC_RCV;
|
||||
els_data->subcategory = LPFC_EVENT_ADISC_RCV;
|
||||
break;
|
||||
case ELS_CMD_LOGO:
|
||||
els_data->subcategory = LPFC_EVENT_LOGO_RCV;
|
||||
/* Copy the WWPN in the LOGO payload */
|
||||
memcpy(logo_data->logo_wwpn, &payload[2],
|
||||
sizeof(struct lpfc_name));
|
||||
break;
|
||||
default:
|
||||
return;
|
||||
}
|
||||
memcpy(els_data.wwpn, &ndlp->nlp_portname, sizeof(struct lpfc_name));
|
||||
memcpy(els_data.wwnn, &ndlp->nlp_nodename, sizeof(struct lpfc_name));
|
||||
fc_host_post_vendor_event(shost,
|
||||
fc_get_event_number(),
|
||||
sizeof(els_data),
|
||||
(char *)&els_data,
|
||||
SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX);
|
||||
memcpy(els_data->wwpn, &ndlp->nlp_portname, sizeof(struct lpfc_name));
|
||||
memcpy(els_data->wwnn, &ndlp->nlp_nodename, sizeof(struct lpfc_name));
|
||||
if (*payload == ELS_CMD_LOGO) {
|
||||
fc_host_post_vendor_event(shost,
|
||||
fc_get_event_number(),
|
||||
sizeof(struct lpfc_logo_event),
|
||||
(char *)logo_data,
|
||||
LPFC_NL_VENDOR_ID);
|
||||
kfree(logo_data);
|
||||
} else {
|
||||
fc_host_post_vendor_event(shost,
|
||||
fc_get_event_number(),
|
||||
sizeof(struct lpfc_els_event_header),
|
||||
(char *)els_data,
|
||||
LPFC_NL_VENDOR_ID);
|
||||
kfree(els_data);
|
||||
}
|
||||
|
||||
return;
|
||||
}
|
||||
@ -5296,7 +5379,7 @@ lpfc_els_unsol_buffer(struct lpfc_hba *phba, struct lpfc_sli_ring *pring,
|
||||
phba->fc_stat.elsRcvPLOGI++;
|
||||
ndlp = lpfc_plogi_confirm_nport(phba, payload, ndlp);
|
||||
|
||||
lpfc_send_els_event(vport, ndlp, cmd);
|
||||
lpfc_send_els_event(vport, ndlp, payload);
|
||||
if (vport->port_state < LPFC_DISC_AUTH) {
|
||||
if (!(phba->pport->fc_flag & FC_PT2PT) ||
|
||||
(phba->pport->fc_flag & FC_PT2PT_PLOGI)) {
|
||||
@ -5334,6 +5417,7 @@ lpfc_els_unsol_buffer(struct lpfc_hba *phba, struct lpfc_sli_ring *pring,
|
||||
did, vport->port_state, ndlp->nlp_flag);
|
||||
|
||||
phba->fc_stat.elsRcvLOGO++;
|
||||
lpfc_send_els_event(vport, ndlp, payload);
|
||||
if (vport->port_state < LPFC_DISC_AUTH) {
|
||||
rjt_err = LSRJT_UNABLE_TPC;
|
||||
break;
|
||||
@ -5346,7 +5430,7 @@ lpfc_els_unsol_buffer(struct lpfc_hba *phba, struct lpfc_sli_ring *pring,
|
||||
did, vport->port_state, ndlp->nlp_flag);
|
||||
|
||||
phba->fc_stat.elsRcvPRLO++;
|
||||
lpfc_send_els_event(vport, ndlp, cmd);
|
||||
lpfc_send_els_event(vport, ndlp, payload);
|
||||
if (vport->port_state < LPFC_DISC_AUTH) {
|
||||
rjt_err = LSRJT_UNABLE_TPC;
|
||||
break;
|
||||
@ -5364,7 +5448,7 @@ lpfc_els_unsol_buffer(struct lpfc_hba *phba, struct lpfc_sli_ring *pring,
|
||||
"RCV ADISC: did:x%x/ste:x%x flg:x%x",
|
||||
did, vport->port_state, ndlp->nlp_flag);
|
||||
|
||||
lpfc_send_els_event(vport, ndlp, cmd);
|
||||
lpfc_send_els_event(vport, ndlp, payload);
|
||||
phba->fc_stat.elsRcvADISC++;
|
||||
if (vport->port_state < LPFC_DISC_AUTH) {
|
||||
rjt_err = LSRJT_UNABLE_TPC;
|
||||
|
@ -387,7 +387,7 @@ lpfc_send_fastpath_evt(struct lpfc_hba *phba,
|
||||
fc_get_event_number(),
|
||||
evt_data_size,
|
||||
evt_data,
|
||||
SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX);
|
||||
LPFC_NL_VENDOR_ID);
|
||||
|
||||
lpfc_free_fast_evt(phba, fast_evt_data);
|
||||
return;
|
||||
|
@ -65,6 +65,9 @@
|
||||
#define SLI3_IOCB_RSP_SIZE 64
|
||||
|
||||
|
||||
/* vendor ID used in SCSI netlink calls */
|
||||
#define LPFC_NL_VENDOR_ID (SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX)
|
||||
|
||||
/* Common Transport structures and definitions */
|
||||
|
||||
union CtRevisionId {
|
||||
|
@ -833,8 +833,7 @@ lpfc_handle_eratt(struct lpfc_hba *phba)
|
||||
fc_host_post_vendor_event(shost, fc_get_event_number(),
|
||||
sizeof(board_event),
|
||||
(char *) &board_event,
|
||||
SCSI_NL_VID_TYPE_PCI
|
||||
| PCI_VENDOR_ID_EMULEX);
|
||||
LPFC_NL_VENDOR_ID);
|
||||
|
||||
if (phba->work_hs & HS_FFER6) {
|
||||
/* Re-establishing Link */
|
||||
@ -2646,7 +2645,7 @@ lpfc_pci_probe_one(struct pci_dev *pdev, const struct pci_device_id *pid)
|
||||
fc_host_post_vendor_event(shost, fc_get_event_number(),
|
||||
sizeof(adapter_event),
|
||||
(char *) &adapter_event,
|
||||
SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX);
|
||||
LPFC_NL_VENDOR_ID);
|
||||
|
||||
scsi_scan_host(shost);
|
||||
|
||||
|
@ -52,6 +52,13 @@
|
||||
* The payload sent via the fc transport is one-way driver->application.
|
||||
*/
|
||||
|
||||
/* RSCN event header */
|
||||
struct lpfc_rscn_event_header {
|
||||
uint32_t event_type;
|
||||
uint32_t payload_length; /* RSCN data length in bytes */
|
||||
uint32_t rscn_payload[];
|
||||
};
|
||||
|
||||
/* els event header */
|
||||
struct lpfc_els_event_header {
|
||||
uint32_t event_type;
|
||||
@ -65,6 +72,7 @@ struct lpfc_els_event_header {
|
||||
#define LPFC_EVENT_PRLO_RCV 0x02
|
||||
#define LPFC_EVENT_ADISC_RCV 0x04
|
||||
#define LPFC_EVENT_LSRJT_RCV 0x08
|
||||
#define LPFC_EVENT_LOGO_RCV 0x10
|
||||
|
||||
/* special els lsrjt event */
|
||||
struct lpfc_lsrjt_event {
|
||||
@ -74,6 +82,11 @@ struct lpfc_lsrjt_event {
|
||||
uint32_t explanation;
|
||||
};
|
||||
|
||||
/* special els logo event */
|
||||
struct lpfc_logo_event {
|
||||
struct lpfc_els_event_header header;
|
||||
uint8_t logo_wwpn[8];
|
||||
};
|
||||
|
||||
/* fabric event header */
|
||||
struct lpfc_fabric_event_header {
|
||||
@ -125,6 +138,7 @@ struct lpfc_scsi_varqueuedepth_event {
|
||||
/* special case scsi check condition event */
|
||||
struct lpfc_scsi_check_condition_event {
|
||||
struct lpfc_scsi_event_header scsi_event;
|
||||
uint8_t opcode;
|
||||
uint8_t sense_key;
|
||||
uint8_t asc;
|
||||
uint8_t ascq;
|
||||
|
@ -1560,7 +1560,7 @@ lpfc_device_reset_handler(struct scsi_cmnd *cmnd)
|
||||
fc_get_event_number(),
|
||||
sizeof(scsi_event),
|
||||
(char *)&scsi_event,
|
||||
SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX);
|
||||
LPFC_NL_VENDOR_ID);
|
||||
|
||||
if (!rdata || pnode->nlp_state != NLP_STE_MAPPED_NODE) {
|
||||
lpfc_printf_vlog(vport, KERN_ERR, LOG_FCP,
|
||||
@ -1657,7 +1657,7 @@ lpfc_bus_reset_handler(struct scsi_cmnd *cmnd)
|
||||
fc_get_event_number(),
|
||||
sizeof(scsi_event),
|
||||
(char *)&scsi_event,
|
||||
SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX);
|
||||
LPFC_NL_VENDOR_ID);
|
||||
|
||||
lpfc_block_error_handler(cmnd);
|
||||
/*
|
||||
|
@ -4005,7 +4005,7 @@ lpfc_sli_async_event_handler(struct lpfc_hba * phba,
|
||||
shost = lpfc_shost_from_vport(phba->pport);
|
||||
fc_host_post_vendor_event(shost, fc_get_event_number(),
|
||||
sizeof(temp_event_data), (char *) &temp_event_data,
|
||||
SCSI_NL_VID_TYPE_PCI | PCI_VENDOR_ID_EMULEX);
|
||||
LPFC_NL_VENDOR_ID);
|
||||
|
||||
}
|
||||
|
||||
|
Loading…