ARM: dts: am43xx-epos-evm: Keep DCDC5 and DCDC6 always on

These regulator outputs are needed even in deep sleep modes to prevent
low-voltage detection events. Make these always ON to avoid this.

Signed-off-by: Kabir Sahane <x0153567@ti.com>
Signed-off-by: Andrew F. Davis <afd@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
This commit is contained in:
Kabir Sahane 2019-03-29 12:53:32 -05:00 committed by Tony Lindgren
parent b5acec09e2
commit d921e53a51

View File

@ -634,12 +634,16 @@
regulator-name = "v1_0bat"; regulator-name = "v1_0bat";
regulator-min-microvolt = <1000000>; regulator-min-microvolt = <1000000>;
regulator-max-microvolt = <1000000>; regulator-max-microvolt = <1000000>;
regulator-boot-on;
regulator-always-on;
}; };
dcdc6: regulator-dcdc6 { dcdc6: regulator-dcdc6 {
regulator-name = "v1_8bat"; regulator-name = "v1_8bat";
regulator-min-microvolt = <1800000>; regulator-min-microvolt = <1800000>;
regulator-max-microvolt = <1800000>; regulator-max-microvolt = <1800000>;
regulator-boot-on;
regulator-always-on;
}; };
ldo1: regulator-ldo1 { ldo1: regulator-ldo1 {