mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-11-17 17:24:17 +08:00
USB: ftdi_sio: add vendor and product id for Bayer glucose meter serial converter cable
Attached patch adds USB vendor and product IDs for Bayer's USB to serial converter cable used by Bayer blood glucose meters. It seems to be a FT232RL based device and works without any problem with ftdi_sio driver when this patch is applied. See: http://winglucofacts.com/cables/ Signed-off-by: Marko Hänninen <bugitus@gmail.com> Cc: stable <stable@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This commit is contained in:
parent
ef4638f955
commit
c47aacc67a
@ -699,6 +699,7 @@ static struct usb_device_id id_table_combined [] = {
|
||||
.driver_info = (kernel_ulong_t)&ftdi_jtag_quirk },
|
||||
{ USB_DEVICE(LARSENBRUSGAARD_VID, LB_ALTITRACK_PID) },
|
||||
{ USB_DEVICE(GN_OTOMETRICS_VID, AURICAL_USB_PID) },
|
||||
{ USB_DEVICE(BAYER_VID, BAYER_CONTOUR_CABLE_PID) },
|
||||
{ }, /* Optional parameter entry */
|
||||
{ } /* Terminating entry */
|
||||
};
|
||||
|
@ -953,6 +953,13 @@
|
||||
#define GN_OTOMETRICS_VID 0x0c33 /* Vendor ID */
|
||||
#define AURICAL_USB_PID 0x0010 /* Aurical USB Audiometer */
|
||||
|
||||
/*
|
||||
* Bayer Ascensia Contour blood glucose meter USB-converter cable.
|
||||
* http://winglucofacts.com/cables/
|
||||
*/
|
||||
#define BAYER_VID 0x1A79
|
||||
#define BAYER_CONTOUR_CABLE_PID 0x6001
|
||||
|
||||
/*
|
||||
* BmRequestType: 1100 0000b
|
||||
* bRequest: FTDI_E2_READ
|
||||
|
Loading…
Reference in New Issue
Block a user