dt-bindings: Add Mantix MLAF057WE51-X panel bindings

The panel uses a Focaltech FT8006p, the touch part is handled by the
already existing edt-ft5x06.

Signed-off-by: Guido Günther <agx@sigxcpu.org>
Reviewed-by: Sam Ravnborg <sam@ravnborg.org>
Signed-off-by: Sam Ravnborg <sam@ravnborg.org>
Link: https://patchwork.freedesktop.org/patch/msgid/b84c8c00ee1dcf545903a475872e1ae62b5f43ea.1597652012.git.agx@sigxcpu.org
This commit is contained in:
Guido Günther 2020-08-17 10:14:35 +02:00 committed by Sam Ravnborg
parent faa962bbae
commit b9ab1248d8

View File

@ -0,0 +1,70 @@
# SPDX-License-Identifier: (GPL-2.0-only or BSD-2-Clause)
%YAML 1.2
---
$id: http://devicetree.org/schemas/display/panel/mantix,mlaf057we51-x.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#
title: Mantix MLAF057WE51-X 5.7" 720x1440 TFT LCD panel
maintainers:
- Guido Günther <agx@sigxcpu.org>
description:
Mantix MLAF057WE51 X is a 720x1440 TFT LCD panel connected using
a MIPI-DSI video interface.
allOf:
- $ref: panel-common.yaml#
properties:
compatible:
enum:
- mantix,mlaf057we51-x
port: true
reg:
maxItems: 1
description: DSI virtual channel
avdd-supply:
description: Positive analog power supply
avee-supply:
description: Negative analog power supply
vddi-supply:
description: 1.8V I/O voltage supply
reset-gpios: true
backlight: true
required:
- compatible
- reg
- avdd-supply
- avee-supply
- vddi-supply
- reset-gpios
additionalProperties: false
examples:
- |
#include <dt-bindings/gpio/gpio.h>
dsi {
#address-cells = <1>;
#size-cells = <0>;
panel@0 {
compatible = "mantix,mlaf057we51-x";
reg = <0>;
avdd-supply = <&reg_avdd>;
avee-supply = <&reg_avee>;
vddi-supply = <&reg_1v8_p>;
reset-gpios = <&gpio1 29 GPIO_ACTIVE_LOW>;
backlight = <&backlight>;
};
};
...