iio: chemical: bme680: Fix calibration data variable

According to the BME68x Sensor API [1], the h6 calibration
data variable should be an unsigned integer of size 8.

[1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L789

Fixes: 1b3bd85927 ("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
Link: https://lore.kernel.org/r/20240606212313.207550-3-vassilisamir@gmail.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Vasileios Amoiridis 2024-06-06 23:22:54 +02:00 committed by Jonathan Cameron
parent ae1f7b93b5
commit b47c0fee73

View File

@ -38,7 +38,7 @@ struct bme680_calib {
s8 par_h3;
s8 par_h4;
s8 par_h5;
s8 par_h6;
u8 par_h6;
s8 par_h7;
s8 par_gh1;
s16 par_gh2;