USB: ohci-pxa27x: Reconfigure power settings on resume

On resume, the power-related bits in UHCRHDA were not being set, so
they would default to the reset state.  For PXA3xx devices, OCPM must
be cleared, but it was remaining set from resume reset.

Signed-off-by: Aric D. Blumer <aric@sdgsystems.com>
Cc: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Signed-off-by: Eric Miao <eric.y.miao@gmail.com>
This commit is contained in:
Aric D. Blumer 2009-07-30 13:42:30 -04:00 committed by Eric Miao
parent 85c6102100
commit a75d048e14

View File

@ -497,6 +497,7 @@ static int ohci_hcd_pxa27x_drv_resume(struct device *dev)
{
struct usb_hcd *hcd = dev_get_drvdata(dev);
struct pxa27x_ohci *ohci = to_pxa27x_ohci(hcd);
struct pxaohci_platform_data *inf = dev->platform_data;
int status;
if (time_before(jiffies, ohci->ohci.next_statechange))
@ -506,6 +507,9 @@ static int ohci_hcd_pxa27x_drv_resume(struct device *dev)
if ((status = pxa27x_start_hc(ohci, dev)) < 0)
return status;
/* Select Power Management Mode */
pxa27x_ohci_select_pmm(ohci, inf->port_mode);
ohci_finish_controller_resume(hcd);
return 0;
}