scsi: lpfc: Reinitialize an NPIV's VMID data structures after FDISC

After a follow up FDISC cmpl, an NPIV's VMID data structures are not
updated.

Fix by calling lpfc_reinit_vmid and copying the physical port's vmid_flag
to the NPIV's vmid_flag in the NPIV registration cmpl code path.

Signed-off-by: Justin Tee <justin.tee@broadcom.com>
Link: https://lore.kernel.org/r/20231207224039.35466-3-justintee8345@gmail.com
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
Justin Tee 2023-12-07 14:40:37 -08:00 committed by Martin K. Petersen
parent 0653d40935
commit 8dc8eb89f4

View File

@ -11143,6 +11143,14 @@ mbox_err_exit:
lpfc_nlp_put(ndlp);
mempool_free(pmb, phba->mbox_mem_pool);
/* reinitialize the VMID datastructure before returning.
* this is specifically for vport
*/
if (lpfc_is_vmid_enabled(phba))
lpfc_reinit_vmid(vport);
vport->vmid_flag = vport->phba->pport->vmid_flag;
return;
}