crypto: safexcel - Raise firmware load failure message to error

At the moment if there is no firmware available for the safexcel driver
it will fail to load with a cryptic:

crypto-safexcel f2800000.crypto: TRC init: 15360d,80a (48r,256h)
crypto-safexcel f2800000.crypto: HW init failed (-2)

Raise the logging level of the firmware load failure to err rather than
dbg so that it's obvious what the reason for the HW init failure is.

Signed-off-by: Jonathan McDowell <noodles@earth.li>
Reviewed-by: Antoine Tenart <atenart@kernel.org>
Signed-off-by: Herbert Xu <herbert@gondor.apana.org.au>
This commit is contained in:
Jonathan McDowell 2023-02-28 18:28:40 +00:00 committed by Herbert Xu
parent 88fca80ec9
commit 86e8e3ce4b

View File

@ -474,7 +474,7 @@ release_fw:
goto retry_fw;
}
dev_dbg(priv->dev, "Firmware load failed.\n");
dev_err(priv->dev, "Firmware load failed.\n");
return ret;
}