media: Documentation: Additional streams generally don't harm capture
Having extra streams on the source end of the link that cannot be captured by the sink sub-device generally are not an issue, at least not on CSI-2 bus. Still document that there may be hardware-specific limitations. For example on parallel bus this might not work on all cases. Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com> Reviewed-by: Tomi Valkeinen <tomi.valkeinen@ideasonboard.com> Reviewed-by: Laurent Pinchart <laurent.pinchart+renesas@ideasonboard.com> Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
This commit is contained in:
parent
21828609f0
commit
744910906d
@ -529,9 +529,9 @@ the its sink pad and allows to route them individually to one of its source
|
||||
pads.
|
||||
|
||||
Subdevice drivers that support multiplexed streams are compatible with
|
||||
non-multiplexed subdev drivers, but, of course, require a routing configuration
|
||||
where the link between those two types of drivers contains only a single
|
||||
stream.
|
||||
non-multiplexed subdev drivers. However, if the driver at the sink end of a link
|
||||
does not support streams, then only stream 0 of source end may be captured.
|
||||
There may be additional limitations specific to the sink device.
|
||||
|
||||