nvme-fabrics: allow to queue requests for live queues

Right now we are failing requests based on the controller state (which
is checked inline in nvmf_check_ready) however we should definitely
accept requests if the queue is live.

When entering controller reset, we transition the controller into
NVME_CTRL_RESETTING, and then return BLK_STS_RESOURCE for non-mpath
requests (have blk_noretry_request set).

This is also the case for NVME_REQ_USER for the wrong reason. There
shouldn't be any reason for us to reject this I/O in a controller reset.
We do want to prevent passthru commands on the admin queue because we
need the controller to fully initialize first before we let user passthru
admin commands to be issued.

In a non-mpath setup, this means that the requests will simply be
requeued over and over forever not allowing the q_usage_counter to drop
its final reference, causing controller reset to hang if running
concurrently with heavy I/O.

Fixes: 35897b920c ("nvme-fabrics: fix and refine state checks in __nvmf_check_ready")
Reviewed-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This commit is contained in:
Sagi Grimberg 2020-09-08 12:56:08 -07:00 committed by Christoph Hellwig
parent ceb1e0874d
commit 73a5379937

View File

@ -565,10 +565,14 @@ bool __nvmf_check_ready(struct nvme_ctrl *ctrl, struct request *rq,
struct nvme_request *req = nvme_req(rq);
/*
* If we are in some state of setup or teardown only allow
* internally generated commands.
* currently we have a problem sending passthru commands
* on the admin_q if the controller is not LIVE because we can't
* make sure that they are going out after the admin connect,
* controller enable and/or other commands in the initialization
* sequence. until the controller will be LIVE, fail with
* BLK_STS_RESOURCE so that they will be rescheduled.
*/
if (!blk_rq_is_passthrough(rq) || (req->flags & NVME_REQ_USERCMD))
if (rq->q == ctrl->admin_q && (req->flags & NVME_REQ_USERCMD))
return false;
/*
@ -577,7 +581,7 @@ bool __nvmf_check_ready(struct nvme_ctrl *ctrl, struct request *rq,
*/
switch (ctrl->state) {
case NVME_CTRL_CONNECTING:
if (nvme_is_fabrics(req->cmd) &&
if (blk_rq_is_passthrough(rq) && nvme_is_fabrics(req->cmd) &&
req->cmd->fabrics.fctype == nvme_fabrics_type_connect)
return true;
break;