iio: fix center temperature of bmc150-accel-core
The center temperature of the supported devices stored in the constant BMC150_ACCEL_TEMP_CENTER_VAL is not 24 degrees but 23 degrees. It seems that some datasheets were inconsistent on this value leading to the error. For most usecases will only make minor difference so not queued for stable. Signed-off-by: Pascal Bouwmann <bouwmann@tau-tec.de> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
85ae3aeede
commit
6c59a962e0
@ -117,7 +117,7 @@
|
||||
#define BMC150_ACCEL_SLEEP_1_SEC 0x0F
|
||||
|
||||
#define BMC150_ACCEL_REG_TEMP 0x08
|
||||
#define BMC150_ACCEL_TEMP_CENTER_VAL 24
|
||||
#define BMC150_ACCEL_TEMP_CENTER_VAL 23
|
||||
|
||||
#define BMC150_ACCEL_AXIS_TO_REG(axis) (BMC150_ACCEL_REG_XOUT_L + (axis * 2))
|
||||