bnxt: apply computed clamp value for coalece parameter

After executing "ethtool -C eth0 rx-usecs-irq 0", the box becomes
unresponsive, likely due to interrupt livelock.  It appears that
a minimum clamp value for the irq timer is computed, but is never
applied.

Fix by applying the corrected clamp value.

Fixes: 74706afa71 ("bnxt_en: Update interrupt coalescing logic.")
Signed-off-by: Jonathan Lemon <jonathan.lemon@gmail.com>
Signed-off-by: Michael Chan <michael.chan@broadcom.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
This commit is contained in:
Jonathan Lemon 2019-12-10 08:39:46 -08:00 committed by Jakub Kicinski
parent 692b93af71
commit 6adc4601c2

View File

@ -6190,7 +6190,7 @@ static void bnxt_hwrm_set_coal_params(struct bnxt *bp,
tmr = bnxt_usec_to_coal_tmr(bp, hw_coal->coal_ticks_irq);
val = clamp_t(u16, tmr, 1,
coal_cap->cmpl_aggr_dma_tmr_during_int_max);
req->cmpl_aggr_dma_tmr_during_int = cpu_to_le16(tmr);
req->cmpl_aggr_dma_tmr_during_int = cpu_to_le16(val);
req->enables |=
cpu_to_le16(BNXT_COAL_CMPL_AGGR_TMR_DURING_INT_ENABLE);
}