clk: ingenic-tcu: Properly enable registers before accessing timers
Access to registers is guarded by ingenic_tcu_{enable,disable}_regs()
so the stop bit can be cleared before accessing a timer channel, but
those functions did not clear the stop bit on SoCs with a global TCU
clock gate.
Testing on the X1000 has revealed that the stop bits must be cleared
_and_ the global TCU clock must be ungated to access timer registers.
This appears to be the norm on Ingenic SoCs, and is specified in the
documentation for the X1000 and numerous JZ47xx SoCs.
If the stop bit isn't cleared, register writes don't take effect and
the system can be left in a broken state, eg. the watchdog timer may
not run.
The bug probably went unnoticed because stop bits are zeroed when
the SoC is reset, and the kernel does not set them unless a timer
gets disabled at runtime. However, it is possible that a bootloader
or a previous kernel (if using kexec) leaves the stop bits set and
we should not rely on them being cleared.
Fixing this is easy: have ingenic_tcu_{enable,disable}_regs() always
clear the stop bit, regardless of the presence of a global TCU gate.
Reviewed-by: Paul Cercueil <paul@crapouillou.net>
Tested-by: Paul Cercueil <paul@crapouillou.net>
Fixes: 4f89e4b8f1
("clk: ingenic: Add driver for the TCU clocks")
Cc: stable@vger.kernel.org
Signed-off-by: Aidan MacDonald <aidanmacdonald.0x0@gmail.com>
Link: https://lore.kernel.org/r/20220617122254.738900-1-aidanmacdonald.0x0@gmail.com
Signed-off-by: Stephen Boyd <sboyd@kernel.org>
This commit is contained in:
parent
abb5f3f4b1
commit
6726d552a6
@ -101,15 +101,11 @@ static bool ingenic_tcu_enable_regs(struct clk_hw *hw)
|
||||
bool enabled = false;
|
||||
|
||||
/*
|
||||
* If the SoC has no global TCU clock, we must ungate the channel's
|
||||
* clock to be able to access its registers.
|
||||
* If we have a TCU clock, it will be enabled automatically as it has
|
||||
* been attached to the regmap.
|
||||
* According to the programming manual, a timer channel's registers can
|
||||
* only be accessed when the channel's stop bit is clear.
|
||||
*/
|
||||
if (!tcu->clk) {
|
||||
enabled = !!ingenic_tcu_is_enabled(hw);
|
||||
regmap_write(tcu->map, TCU_REG_TSCR, BIT(info->gate_bit));
|
||||
}
|
||||
|
||||
return enabled;
|
||||
}
|
||||
@ -120,7 +116,6 @@ static void ingenic_tcu_disable_regs(struct clk_hw *hw)
|
||||
const struct ingenic_tcu_clk_info *info = tcu_clk->info;
|
||||
struct ingenic_tcu *tcu = tcu_clk->tcu;
|
||||
|
||||
if (!tcu->clk)
|
||||
regmap_write(tcu->map, TCU_REG_TSSR, BIT(info->gate_bit));
|
||||
}
|
||||
|
||||
|
Loading…