mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-11-29 07:04:10 +08:00
thermal: hisilicon: increase temperature resolution
When calculate temperature, old code firstly do division and then convert to "millicelsius" unit. This will lose resolution and only can read back temperature with "Celsius" unit. So firstly scale step value to "millicelsius" and then do division, so finally we can increase resolution for temperature value. Also refine the calculation from temperature value to step value. Signed-off-by: Leo Yan <leo.yan@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
913f201083
commit
5fdfc48bb0
@ -68,12 +68,12 @@ static inline int _step_to_temp(int step)
|
||||
* Every step equals (1 * 200) / 255 celsius, and finally
|
||||
* need convert to millicelsius.
|
||||
*/
|
||||
return (HISI_TEMP_BASE + (step * 200 / 255)) * 1000;
|
||||
return (HISI_TEMP_BASE * 1000 + (step * 200000 / 255));
|
||||
}
|
||||
|
||||
static inline long _temp_to_step(long temp)
|
||||
{
|
||||
return ((temp / 1000 - HISI_TEMP_BASE) * 255 / 200);
|
||||
return ((temp - HISI_TEMP_BASE * 1000) * 255) / 200000;
|
||||
}
|
||||
|
||||
static long hisi_thermal_get_sensor_temp(struct hisi_thermal_data *data,
|
||||
|
Loading…
Reference in New Issue
Block a user