PM / OPP: Reword binding supporting multiple regulators per device

On certain platforms (like TI), DVFS for a single device (CPU) requires
configuring multiple power supplies.

The OPP bindings already contains binding and example to explain this
case, but it isn't sufficient.

- There is no way for the code parsing these bindings to know which
  voltage values belong to which power supply.

- It is not possible to know the order in which the supplies need to be
  configured while switching OPPs.

This patch clarifies on those details by mentioning that such
information is left for the implementation specific bindings to explain.
They may want to hardcode such details or implement their own properties
to get such information. All implementations using multiple regulators
for their devices must provide a binding document explaining their
implementation.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Acked-by: Rob Herring <robh@kernel.org>
Reviewed-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
This commit is contained in:
Viresh Kumar 2016-12-01 16:28:15 +05:30 committed by Rafael J. Wysocki
parent 309fe8d650
commit 579c49efdf

View File

@ -86,8 +86,14 @@ Optional properties:
Single entry is for target voltage and three entries are for <target min max>
voltages.
Entries for multiple regulators must be present in the same order as
regulators are specified in device's DT node.
Entries for multiple regulators shall be provided in the same field separated
by angular brackets <>. The OPP binding doesn't provide any provisions to
relate the values to their power supplies or the order in which the supplies
need to be configured and that is left for the implementation specific
binding.
Entries for all regulators shall be of the same size, i.e. either all use a
single value or triplets.
- opp-microvolt-<name>: Named opp-microvolt property. This is exactly similar to
the above opp-microvolt property, but allows multiple voltage ranges to be
@ -104,10 +110,13 @@ Optional properties:
Should only be set if opp-microvolt is set for the OPP.
Entries for multiple regulators must be present in the same order as
regulators are specified in device's DT node. If this property isn't required
for few regulators, then this should be marked as zero for them. If it isn't
required for any regulator, then this property need not be present.
Entries for multiple regulators shall be provided in the same field separated
by angular brackets <>. If current values aren't required for a regulator,
then it shall be filled with 0. If current values aren't required for any of
the regulators, then this field is not required. The OPP binding doesn't
provide any provisions to relate the values to their power supplies or the
order in which the supplies need to be configured and that is left for the
implementation specific binding.
- opp-microamp-<name>: Named opp-microamp property. Similar to
opp-microvolt-<name> property, but for microamp instead.