[TIPC]: Unrecognized configuration command now returns error message

This patch causes TIPC to return an error message when it receives
an unrecognized configuration command.  (Previously, the sender
received no feedback.)

Signed-off-by: Allan Stephens <allan.stephens@windriver.com>
Signed-off-by: Per Liden <per.liden@ericsson.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Allan Stephens 2006-10-16 22:00:56 -07:00 committed by David S. Miller
parent eb409460b1
commit 53cfd1e102

View File

@ -2,7 +2,7 @@
* net/tipc/config.c: TIPC configuration management code
*
* Copyright (c) 2002-2006, Ericsson AB
* Copyright (c) 2004-2005, Wind River Systems
* Copyright (c) 2004-2006, Wind River Systems
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
@ -613,7 +613,8 @@ struct sk_buff *tipc_cfg_do_cmd(u32 orig_node, u16 cmd, const void *request_area
rep_tlv_buf = tipc_cfg_reply_unsigned(tipc_net_id);
break;
default:
rep_tlv_buf = NULL;
rep_tlv_buf = tipc_cfg_reply_error_string(TIPC_CFG_NOT_SUPPORTED
" (unknown command)");
break;
}