drm/msm/dp: use dp_ctrl_off_link_stream during PHY compliance test run

DP cable should always connect to DPU during the entire PHY compliance
testing run. Since DP PHY compliance test is executed at irq_hpd event
context, dp_ctrl_off_link_stream() should be used instead of dp_ctrl_off().
dp_ctrl_off() is used for unplug event which is triggered when DP cable is
dis connected.

Changes in V2:
-- add fixes statement

Fixes: f21c8a276c ("drm/msm/dp: handle irq_hpd with sink_count = 0 correctly")

Signed-off-by: Kuogee Hsieh <khsieh@codeaurora.org>
Reviewed-by: Stephen Boyd <swboyd@chromium.org>
Link: https://lore.kernel.org/r/1628196295-7382-2-git-send-email-khsieh@codeaurora.org
Signed-off-by: Rob Clark <robdclark@chromium.org>
This commit is contained in:
Kuogee Hsieh 2021-08-05 13:44:50 -07:00 committed by Rob Clark
parent 6977cc89c8
commit 52352fe2f8

View File

@ -1529,7 +1529,7 @@ static int dp_ctrl_process_phy_test_request(struct dp_ctrl_private *ctrl)
* running. Add the global reset just before disabling the
* link clocks and core clocks.
*/
ret = dp_ctrl_off(&ctrl->dp_ctrl);
ret = dp_ctrl_off_link_stream(&ctrl->dp_ctrl);
if (ret) {
DRM_ERROR("failed to disable DP controller\n");
return ret;