Merge branch 'release' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management update from Zhang Rui: "Highlights: - Introduction of thermal policy support, together with three new thermal governors, including step_wise, user_space, fire_share. - Introduction of ST-Ericsson db8500_thermal driver and ST-Ericsson db8500_cpufreq_cooling driver. - Thermal Kconfig file and Makefile refactor. - Fixes for generic thermal layer, generic cpucooling, rcar thermal driver and Exynos thermal driver." * 'release' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (36 commits) Thermal: Fix DEFAULT_THERMAL_GOVERNOR Thermal: fix a NULL pointer dereference when generic thermal layer is built as a module thermal: rcar: add rcar_zone_to_priv() macro thermal: rcar: fixup the unit of temperature thermal: cpu cooling: allow module builds thermal: cpu cooling: use const parameter while registering Thermal: Add ST-Ericsson DB8500 thermal properties and platform data. Thermal: Add ST-Ericsson DB8500 thermal driver. drivers/thermal/Makefile refactor Exynos: Add missing dependency Refactor drivers/thermal/Kconfig thermal: cpu_cooling: Make 'notify_device' static Thermal: Remove the cooling_cpufreq_list. Thermal: fix bug of counting cpu frequencies. Thermal: add indent for code alignment. thermal: rcar_thermal: remove explicitly used devm_kfree/iounap() thermal: user_space: Add missing static storage class specifiers thermal: fair_share: Add missing static storage class specifiers thermal: step_wise: Add missing static storage class specifiers Thermal: Fix oops and unlocking in thermal_sys.c ...
This commit is contained in:
commit
50851c6248
44
Documentation/devicetree/bindings/thermal/db8500-thermal.txt
Normal file
44
Documentation/devicetree/bindings/thermal/db8500-thermal.txt
Normal file
@ -0,0 +1,44 @@
|
||||
* ST-Ericsson DB8500 Thermal
|
||||
|
||||
** Thermal node properties:
|
||||
|
||||
- compatible : "stericsson,db8500-thermal";
|
||||
- reg : address range of the thermal sensor registers;
|
||||
- interrupts : interrupts generated from PRCMU;
|
||||
- interrupt-names : "IRQ_HOTMON_LOW" and "IRQ_HOTMON_HIGH";
|
||||
- num-trips : number of total trip points, this is required, set it 0 if none,
|
||||
if greater than 0, the following properties must be defined;
|
||||
- tripN-temp : temperature of trip point N, should be in ascending order;
|
||||
- tripN-type : type of trip point N, should be one of "active" "passive" "hot"
|
||||
"critical";
|
||||
- tripN-cdev-num : number of the cooling devices which can be bound to trip
|
||||
point N, this is required if trip point N is defined, set it 0 if none,
|
||||
otherwise the following cooling device names must be defined;
|
||||
- tripN-cdev-nameM : name of the No. M cooling device of trip point N;
|
||||
|
||||
Usually the num-trips and tripN-*** are separated in board related dts files.
|
||||
|
||||
Example:
|
||||
thermal@801573c0 {
|
||||
compatible = "stericsson,db8500-thermal";
|
||||
reg = <0x801573c0 0x40>;
|
||||
interrupts = <21 0x4>, <22 0x4>;
|
||||
interrupt-names = "IRQ_HOTMON_LOW", "IRQ_HOTMON_HIGH";
|
||||
|
||||
num-trips = <3>;
|
||||
|
||||
trip0-temp = <75000>;
|
||||
trip0-type = "active";
|
||||
trip0-cdev-num = <1>;
|
||||
trip0-cdev-name0 = "thermal-cpufreq-0";
|
||||
|
||||
trip1-temp = <80000>;
|
||||
trip1-type = "active";
|
||||
trip1-cdev-num = <2>;
|
||||
trip1-cdev-name0 = "thermal-cpufreq-0";
|
||||
trip1-cdev-name1 = "thermal-fan";
|
||||
|
||||
trip2-temp = <85000>;
|
||||
trip2-type = "critical";
|
||||
trip2-cdev-num = <0>;
|
||||
}
|
@ -112,6 +112,29 @@ temperature) and throttle appropriate devices.
|
||||
trip: indicates which trip point the cooling devices is associated with
|
||||
in this thermal zone.
|
||||
|
||||
1.4 Thermal Zone Parameters
|
||||
1.4.1 struct thermal_bind_params
|
||||
This structure defines the following parameters that are used to bind
|
||||
a zone with a cooling device for a particular trip point.
|
||||
.cdev: The cooling device pointer
|
||||
.weight: The 'influence' of a particular cooling device on this zone.
|
||||
This is on a percentage scale. The sum of all these weights
|
||||
(for a particular zone) cannot exceed 100.
|
||||
.trip_mask:This is a bit mask that gives the binding relation between
|
||||
this thermal zone and cdev, for a particular trip point.
|
||||
If nth bit is set, then the cdev and thermal zone are bound
|
||||
for trip point n.
|
||||
.match: This call back returns success(0) if the 'tz and cdev' need to
|
||||
be bound, as per platform data.
|
||||
1.4.2 struct thermal_zone_params
|
||||
This structure defines the platform level parameters for a thermal zone.
|
||||
This data, for each thermal zone should come from the platform layer.
|
||||
This is an optional feature where some platforms can choose not to
|
||||
provide this data.
|
||||
.governor_name: Name of the thermal governor used for this zone
|
||||
.num_tbps: Number of thermal_bind_params entries for this zone
|
||||
.tbp: thermal_bind_params entries
|
||||
|
||||
2. sysfs attributes structure
|
||||
|
||||
RO read only value
|
||||
@ -126,6 +149,7 @@ Thermal zone device sys I/F, created once it's registered:
|
||||
|---type: Type of the thermal zone
|
||||
|---temp: Current temperature
|
||||
|---mode: Working mode of the thermal zone
|
||||
|---policy: Thermal governor used for this zone
|
||||
|---trip_point_[0-*]_temp: Trip point temperature
|
||||
|---trip_point_[0-*]_type: Trip point type
|
||||
|---trip_point_[0-*]_hyst: Hysteresis value for this trip point
|
||||
@ -187,6 +211,10 @@ mode
|
||||
charge of the thermal management.
|
||||
RW, Optional
|
||||
|
||||
policy
|
||||
One of the various thermal governors used for a particular zone.
|
||||
RW, Required
|
||||
|
||||
trip_point_[0-*]_temp
|
||||
The temperature above which trip point will be fired.
|
||||
Unit: millidegree Celsius
|
||||
@ -264,6 +292,7 @@ method, the sys I/F structure will be built like this:
|
||||
|---type: acpitz
|
||||
|---temp: 37000
|
||||
|---mode: enabled
|
||||
|---policy: step_wise
|
||||
|---trip_point_0_temp: 100000
|
||||
|---trip_point_0_type: critical
|
||||
|---trip_point_1_temp: 80000
|
||||
@ -305,3 +334,38 @@ to a thermal_zone_device when it registers itself with the framework. The
|
||||
event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
|
||||
THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
|
||||
crosses any of the configured thresholds.
|
||||
|
||||
5. Export Symbol APIs:
|
||||
|
||||
5.1: get_tz_trend:
|
||||
This function returns the trend of a thermal zone, i.e the rate of change
|
||||
of temperature of the thermal zone. Ideally, the thermal sensor drivers
|
||||
are supposed to implement the callback. If they don't, the thermal
|
||||
framework calculated the trend by comparing the previous and the current
|
||||
temperature values.
|
||||
|
||||
5.2:get_thermal_instance:
|
||||
This function returns the thermal_instance corresponding to a given
|
||||
{thermal_zone, cooling_device, trip_point} combination. Returns NULL
|
||||
if such an instance does not exist.
|
||||
|
||||
5.3:notify_thermal_framework:
|
||||
This function handles the trip events from sensor drivers. It starts
|
||||
throttling the cooling devices according to the policy configured.
|
||||
For CRITICAL and HOT trip points, this notifies the respective drivers,
|
||||
and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
|
||||
The throttling policy is based on the configured platform data; if no
|
||||
platform data is provided, this uses the step_wise throttling policy.
|
||||
|
||||
5.4:thermal_cdev_update:
|
||||
This function serves as an arbitrator to set the state of a cooling
|
||||
device. It sets the cooling device to the deepest cooling state if
|
||||
possible.
|
||||
|
||||
5.5:thermal_register_governor:
|
||||
This function lets the various thermal governors to register themselves
|
||||
with the Thermal framework. At run time, depending on a zone's platform
|
||||
data, a particular governor is used for throttling.
|
||||
|
||||
5.6:thermal_unregister_governor:
|
||||
This function unregisters a governor from the thermal framework.
|
||||
|
@ -203,6 +203,14 @@
|
||||
reg = <0x80157450 0xC>;
|
||||
};
|
||||
|
||||
thermal@801573c0 {
|
||||
compatible = "stericsson,db8500-thermal";
|
||||
reg = <0x801573c0 0x40>;
|
||||
interrupts = <21 0x4>, <22 0x4>;
|
||||
interrupt-names = "IRQ_HOTMON_LOW", "IRQ_HOTMON_HIGH";
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
db8500-prcmu-regulators {
|
||||
compatible = "stericsson,db8500-prcmu-regulator";
|
||||
|
||||
@ -660,5 +668,11 @@
|
||||
ranges = <0 0x50000000 0x4000000>;
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
cpufreq-cooling {
|
||||
compatible = "stericsson,db8500-cpufreq-cooling";
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
};
|
||||
};
|
||||
|
@ -99,6 +99,33 @@
|
||||
status = "okay";
|
||||
};
|
||||
|
||||
prcmu@80157000 {
|
||||
thermal@801573c0 {
|
||||
num-trips = <4>;
|
||||
|
||||
trip0-temp = <70000>;
|
||||
trip0-type = "active";
|
||||
trip0-cdev-num = <1>;
|
||||
trip0-cdev-name0 = "thermal-cpufreq-0";
|
||||
|
||||
trip1-temp = <75000>;
|
||||
trip1-type = "active";
|
||||
trip1-cdev-num = <1>;
|
||||
trip1-cdev-name0 = "thermal-cpufreq-0";
|
||||
|
||||
trip2-temp = <80000>;
|
||||
trip2-type = "active";
|
||||
trip2-cdev-num = <1>;
|
||||
trip2-cdev-name0 = "thermal-cpufreq-0";
|
||||
|
||||
trip3-temp = <85000>;
|
||||
trip3-type = "critical";
|
||||
trip3-cdev-num = <0>;
|
||||
|
||||
status = "okay";
|
||||
};
|
||||
};
|
||||
|
||||
external-bus@50000000 {
|
||||
status = "okay";
|
||||
|
||||
@ -183,5 +210,9 @@
|
||||
reg = <0x33>;
|
||||
};
|
||||
};
|
||||
|
||||
cpufreq-cooling {
|
||||
status = "okay";
|
||||
};
|
||||
};
|
||||
};
|
||||
|
@ -69,6 +69,8 @@ CONFIG_GPIO_TC3589X=y
|
||||
CONFIG_POWER_SUPPLY=y
|
||||
CONFIG_AB8500_BM=y
|
||||
CONFIG_AB8500_BATTERY_THERM_ON_BATCTRL=y
|
||||
CONFIG_THERMAL=y
|
||||
CONFIG_CPU_THERMAL=y
|
||||
CONFIG_MFD_STMPE=y
|
||||
CONFIG_MFD_TC3589X=y
|
||||
CONFIG_AB5500_CORE=y
|
||||
|
@ -16,6 +16,7 @@
|
||||
#include <linux/io.h>
|
||||
#include <linux/i2c.h>
|
||||
#include <linux/platform_data/i2c-nomadik.h>
|
||||
#include <linux/platform_data/db8500_thermal.h>
|
||||
#include <linux/gpio.h>
|
||||
#include <linux/amba/bus.h>
|
||||
#include <linux/amba/pl022.h>
|
||||
@ -228,6 +229,67 @@ static struct ab8500_platform_data ab8500_platdata = {
|
||||
.codec = &ab8500_codec_pdata,
|
||||
};
|
||||
|
||||
/*
|
||||
* Thermal Sensor
|
||||
*/
|
||||
|
||||
static struct resource db8500_thsens_resources[] = {
|
||||
{
|
||||
.name = "IRQ_HOTMON_LOW",
|
||||
.start = IRQ_PRCMU_HOTMON_LOW,
|
||||
.end = IRQ_PRCMU_HOTMON_LOW,
|
||||
.flags = IORESOURCE_IRQ,
|
||||
},
|
||||
{
|
||||
.name = "IRQ_HOTMON_HIGH",
|
||||
.start = IRQ_PRCMU_HOTMON_HIGH,
|
||||
.end = IRQ_PRCMU_HOTMON_HIGH,
|
||||
.flags = IORESOURCE_IRQ,
|
||||
},
|
||||
};
|
||||
|
||||
static struct db8500_thsens_platform_data db8500_thsens_data = {
|
||||
.trip_points[0] = {
|
||||
.temp = 70000,
|
||||
.type = THERMAL_TRIP_ACTIVE,
|
||||
.cdev_name = {
|
||||
[0] = "thermal-cpufreq-0",
|
||||
},
|
||||
},
|
||||
.trip_points[1] = {
|
||||
.temp = 75000,
|
||||
.type = THERMAL_TRIP_ACTIVE,
|
||||
.cdev_name = {
|
||||
[0] = "thermal-cpufreq-0",
|
||||
},
|
||||
},
|
||||
.trip_points[2] = {
|
||||
.temp = 80000,
|
||||
.type = THERMAL_TRIP_ACTIVE,
|
||||
.cdev_name = {
|
||||
[0] = "thermal-cpufreq-0",
|
||||
},
|
||||
},
|
||||
.trip_points[3] = {
|
||||
.temp = 85000,
|
||||
.type = THERMAL_TRIP_CRITICAL,
|
||||
},
|
||||
.num_trips = 4,
|
||||
};
|
||||
|
||||
static struct platform_device u8500_thsens_device = {
|
||||
.name = "db8500-thermal",
|
||||
.resource = db8500_thsens_resources,
|
||||
.num_resources = ARRAY_SIZE(db8500_thsens_resources),
|
||||
.dev = {
|
||||
.platform_data = &db8500_thsens_data,
|
||||
},
|
||||
};
|
||||
|
||||
static struct platform_device u8500_cpufreq_cooling_device = {
|
||||
.name = "db8500-cpufreq-cooling",
|
||||
};
|
||||
|
||||
/*
|
||||
* TPS61052
|
||||
*/
|
||||
@ -583,6 +645,8 @@ static struct platform_device *snowball_platform_devs[] __initdata = {
|
||||
&snowball_key_dev,
|
||||
&snowball_sbnet_dev,
|
||||
&snowball_gpio_en_3v3_regulator_dev,
|
||||
&u8500_thsens_device,
|
||||
&u8500_cpufreq_cooling_device,
|
||||
};
|
||||
|
||||
static void __init mop500_init_machine(void)
|
||||
|
@ -900,14 +900,14 @@ static int acpi_thermal_register_thermal_zone(struct acpi_thermal *tz)
|
||||
if (tz->trips.passive.flags.valid)
|
||||
tz->thermal_zone =
|
||||
thermal_zone_device_register("acpitz", trips, 0, tz,
|
||||
&acpi_thermal_zone_ops,
|
||||
&acpi_thermal_zone_ops, NULL,
|
||||
tz->trips.passive.tsp*100,
|
||||
tz->polling_frequency*100);
|
||||
else
|
||||
tz->thermal_zone =
|
||||
thermal_zone_device_register("acpitz", trips, 0, tz,
|
||||
&acpi_thermal_zone_ops, 0,
|
||||
tz->polling_frequency*100);
|
||||
&acpi_thermal_zone_ops, NULL,
|
||||
0, tz->polling_frequency*100);
|
||||
if (IS_ERR(tz->thermal_zone))
|
||||
return -ENODEV;
|
||||
|
||||
|
@ -662,7 +662,7 @@ static int acerhdf_register_thermal(void)
|
||||
return -EINVAL;
|
||||
|
||||
thz_dev = thermal_zone_device_register("acerhdf", 1, 0, NULL,
|
||||
&acerhdf_dev_ops, 0,
|
||||
&acerhdf_dev_ops, NULL, 0,
|
||||
(kernelmode) ? interval*1000 : 0);
|
||||
if (IS_ERR(thz_dev))
|
||||
return -EINVAL;
|
||||
|
@ -502,7 +502,7 @@ static int mid_thermal_probe(struct platform_device *pdev)
|
||||
goto err;
|
||||
}
|
||||
pinfo->tzd[i] = thermal_zone_device_register(name[i],
|
||||
0, 0, td_info, &tzd_ops, 0, 0);
|
||||
0, 0, td_info, &tzd_ops, NULL, 0, 0);
|
||||
if (IS_ERR(pinfo->tzd[i])) {
|
||||
kfree(td_info);
|
||||
ret = PTR_ERR(pinfo->tzd[i]);
|
||||
|
@ -201,7 +201,7 @@ static int psy_register_thermal(struct power_supply *psy)
|
||||
for (i = 0; i < psy->num_properties; i++) {
|
||||
if (psy->properties[i] == POWER_SUPPLY_PROP_TEMP) {
|
||||
psy->tzd = thermal_zone_device_register(psy->name, 0, 0,
|
||||
psy, &psy_tzd_ops, 0, 0);
|
||||
psy, &psy_tzd_ops, NULL, 0, 0);
|
||||
if (IS_ERR(psy->tzd))
|
||||
return PTR_ERR(psy->tzd);
|
||||
break;
|
||||
|
@ -270,7 +270,7 @@ int omap_thermal_expose_sensor(struct omap_bandgap *bg_ptr, int id,
|
||||
/* Create thermal zone */
|
||||
data->omap_thermal = thermal_zone_device_register(domain,
|
||||
OMAP_TRIP_NUMBER, 0, data, &omap_thermal_ops,
|
||||
FAST_TEMP_MONITORING_RATE,
|
||||
NULL, FAST_TEMP_MONITORING_RATE,
|
||||
FAST_TEMP_MONITORING_RATE);
|
||||
if (IS_ERR_OR_NULL(data->omap_thermal)) {
|
||||
dev_err(bg_ptr->dev, "thermal zone device is NULL\n");
|
||||
|
@ -13,15 +13,62 @@ menuconfig THERMAL
|
||||
All platforms with ACPI thermal support can use this driver.
|
||||
If you want this support, you should say Y or M here.
|
||||
|
||||
if THERMAL
|
||||
|
||||
config THERMAL_HWMON
|
||||
bool
|
||||
depends on THERMAL
|
||||
depends on HWMON=y || HWMON=THERMAL
|
||||
default y
|
||||
|
||||
choice
|
||||
prompt "Default Thermal governor"
|
||||
default THERMAL_DEFAULT_GOV_STEP_WISE
|
||||
help
|
||||
This option sets which thermal governor shall be loaded at
|
||||
startup. If in doubt, select 'step_wise'.
|
||||
|
||||
config THERMAL_DEFAULT_GOV_STEP_WISE
|
||||
bool "step_wise"
|
||||
select STEP_WISE
|
||||
help
|
||||
Use the step_wise governor as default. This throttles the
|
||||
devices one step at a time.
|
||||
|
||||
config THERMAL_DEFAULT_GOV_FAIR_SHARE
|
||||
bool "fair_share"
|
||||
select FAIR_SHARE
|
||||
help
|
||||
Use the fair_share governor as default. This throttles the
|
||||
devices based on their 'contribution' to a zone. The
|
||||
contribution should be provided through platform data.
|
||||
|
||||
config THERMAL_DEFAULT_GOV_USER_SPACE
|
||||
bool "user_space"
|
||||
select USER_SPACE
|
||||
help
|
||||
Select this if you want to let the user space manage the
|
||||
lpatform thermals.
|
||||
|
||||
endchoice
|
||||
|
||||
config FAIR_SHARE
|
||||
bool "Fair-share thermal governor"
|
||||
help
|
||||
Enable this to manage platform thermals using fair-share governor.
|
||||
|
||||
config STEP_WISE
|
||||
bool "Step_wise thermal governor"
|
||||
help
|
||||
Enable this to manage platform thermals using a simple linear
|
||||
|
||||
config USER_SPACE
|
||||
bool "User_space thermal governor"
|
||||
help
|
||||
Enable this to let the user space manage the platform thermals.
|
||||
|
||||
config CPU_THERMAL
|
||||
bool "generic cpu cooling support"
|
||||
depends on THERMAL && CPU_FREQ
|
||||
tristate "generic cpu cooling support"
|
||||
depends on CPU_FREQ
|
||||
select CPU_FREQ_TABLE
|
||||
help
|
||||
This implements the generic cpu cooling mechanism through frequency
|
||||
@ -33,7 +80,6 @@ config CPU_THERMAL
|
||||
|
||||
config SPEAR_THERMAL
|
||||
bool "SPEAr thermal sensor driver"
|
||||
depends on THERMAL
|
||||
depends on PLAT_SPEAR
|
||||
depends on OF
|
||||
help
|
||||
@ -42,7 +88,6 @@ config SPEAR_THERMAL
|
||||
|
||||
config RCAR_THERMAL
|
||||
tristate "Renesas R-Car thermal driver"
|
||||
depends on THERMAL
|
||||
depends on ARCH_SHMOBILE
|
||||
help
|
||||
Enable this to plug the R-Car thermal sensor driver into the Linux
|
||||
@ -50,8 +95,31 @@ config RCAR_THERMAL
|
||||
|
||||
config EXYNOS_THERMAL
|
||||
tristate "Temperature sensor on Samsung EXYNOS"
|
||||
depends on (ARCH_EXYNOS4 || ARCH_EXYNOS5) && THERMAL
|
||||
select CPU_FREQ_TABLE
|
||||
depends on (ARCH_EXYNOS4 || ARCH_EXYNOS5)
|
||||
depends on CPU_THERMAL
|
||||
help
|
||||
If you say yes here you get support for TMU (Thermal Managment
|
||||
Unit) on SAMSUNG EXYNOS series of SoC.
|
||||
|
||||
config DB8500_THERMAL
|
||||
bool "DB8500 thermal management"
|
||||
depends on ARCH_U8500
|
||||
default y
|
||||
help
|
||||
Adds DB8500 thermal management implementation according to the thermal
|
||||
management framework. A thermal zone with several trip points will be
|
||||
created. Cooling devices can be bound to the trip points to cool this
|
||||
thermal zone if trip points reached.
|
||||
|
||||
config DB8500_CPUFREQ_COOLING
|
||||
tristate "DB8500 cpufreq cooling"
|
||||
depends on ARCH_U8500
|
||||
depends on CPU_THERMAL
|
||||
default y
|
||||
help
|
||||
Adds DB8500 cpufreq cooling devices, and these cooling devices can be
|
||||
bound to thermal zone trip points. When a trip point reached, the
|
||||
bound cpufreq cooling device turns active to set CPU frequency low to
|
||||
cool down the CPU.
|
||||
|
||||
endif
|
||||
|
@ -3,7 +3,18 @@
|
||||
#
|
||||
|
||||
obj-$(CONFIG_THERMAL) += thermal_sys.o
|
||||
obj-$(CONFIG_CPU_THERMAL) += cpu_cooling.o
|
||||
obj-$(CONFIG_SPEAR_THERMAL) += spear_thermal.o
|
||||
|
||||
# governors
|
||||
obj-$(CONFIG_FAIR_SHARE) += fair_share.o
|
||||
obj-$(CONFIG_STEP_WISE) += step_wise.o
|
||||
obj-$(CONFIG_USER_SPACE) += user_space.o
|
||||
|
||||
# cpufreq cooling
|
||||
obj-$(CONFIG_CPU_THERMAL) += cpu_cooling.o
|
||||
|
||||
# platform thermal drivers
|
||||
obj-$(CONFIG_SPEAR_THERMAL) += spear_thermal.o
|
||||
obj-$(CONFIG_RCAR_THERMAL) += rcar_thermal.o
|
||||
obj-$(CONFIG_EXYNOS_THERMAL) += exynos_thermal.o
|
||||
obj-$(CONFIG_EXYNOS_THERMAL) += exynos_thermal.o
|
||||
obj-$(CONFIG_DB8500_THERMAL) += db8500_thermal.o
|
||||
obj-$(CONFIG_DB8500_CPUFREQ_COOLING) += db8500_cpufreq_cooling.o
|
||||
|
@ -58,12 +58,13 @@ struct cpufreq_cooling_device {
|
||||
};
|
||||
static LIST_HEAD(cooling_cpufreq_list);
|
||||
static DEFINE_IDR(cpufreq_idr);
|
||||
static DEFINE_MUTEX(cooling_cpufreq_lock);
|
||||
|
||||
static struct mutex cooling_cpufreq_lock;
|
||||
static unsigned int cpufreq_dev_count;
|
||||
|
||||
/* notify_table passes value to the CPUFREQ_ADJUST callback function. */
|
||||
#define NOTIFY_INVALID NULL
|
||||
struct cpufreq_cooling_device *notify_device;
|
||||
static struct cpufreq_cooling_device *notify_device;
|
||||
|
||||
/**
|
||||
* get_idr - function to get a unique id.
|
||||
@ -240,42 +241,32 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
|
||||
static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
|
||||
unsigned long *state)
|
||||
{
|
||||
int ret = -EINVAL, i = 0;
|
||||
struct cpufreq_cooling_device *cpufreq_device;
|
||||
struct cpumask *maskPtr;
|
||||
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
|
||||
struct cpumask *maskPtr = &cpufreq_device->allowed_cpus;
|
||||
unsigned int cpu;
|
||||
struct cpufreq_frequency_table *table;
|
||||
unsigned long count = 0;
|
||||
int i = 0;
|
||||
|
||||
mutex_lock(&cooling_cpufreq_lock);
|
||||
list_for_each_entry(cpufreq_device, &cooling_cpufreq_list, node) {
|
||||
if (cpufreq_device && cpufreq_device->cool_dev == cdev)
|
||||
break;
|
||||
}
|
||||
if (cpufreq_device == NULL)
|
||||
goto return_get_max_state;
|
||||
|
||||
maskPtr = &cpufreq_device->allowed_cpus;
|
||||
cpu = cpumask_any(maskPtr);
|
||||
table = cpufreq_frequency_get_table(cpu);
|
||||
if (!table) {
|
||||
*state = 0;
|
||||
ret = 0;
|
||||
goto return_get_max_state;
|
||||
return 0;
|
||||
}
|
||||
|
||||
while (table[i].frequency != CPUFREQ_TABLE_END) {
|
||||
for (i = 0; (table[i].frequency != CPUFREQ_TABLE_END); i++) {
|
||||
if (table[i].frequency == CPUFREQ_ENTRY_INVALID)
|
||||
continue;
|
||||
i++;
|
||||
}
|
||||
if (i > 0) {
|
||||
*state = --i;
|
||||
ret = 0;
|
||||
count++;
|
||||
}
|
||||
|
||||
return_get_max_state:
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
return ret;
|
||||
if (count > 0) {
|
||||
*state = --count;
|
||||
return 0;
|
||||
}
|
||||
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
/**
|
||||
@ -286,20 +277,10 @@ return_get_max_state:
|
||||
static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
|
||||
unsigned long *state)
|
||||
{
|
||||
int ret = -EINVAL;
|
||||
struct cpufreq_cooling_device *cpufreq_device;
|
||||
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
|
||||
|
||||
mutex_lock(&cooling_cpufreq_lock);
|
||||
list_for_each_entry(cpufreq_device, &cooling_cpufreq_list, node) {
|
||||
if (cpufreq_device && cpufreq_device->cool_dev == cdev) {
|
||||
*state = cpufreq_device->cpufreq_state;
|
||||
ret = 0;
|
||||
break;
|
||||
}
|
||||
}
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
|
||||
return ret;
|
||||
*state = cpufreq_device->cpufreq_state;
|
||||
return 0;
|
||||
}
|
||||
|
||||
/**
|
||||
@ -310,22 +291,9 @@ static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
|
||||
static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
|
||||
unsigned long state)
|
||||
{
|
||||
int ret = -EINVAL;
|
||||
struct cpufreq_cooling_device *cpufreq_device;
|
||||
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
|
||||
|
||||
mutex_lock(&cooling_cpufreq_lock);
|
||||
list_for_each_entry(cpufreq_device, &cooling_cpufreq_list, node) {
|
||||
if (cpufreq_device && cpufreq_device->cool_dev == cdev) {
|
||||
ret = 0;
|
||||
break;
|
||||
}
|
||||
}
|
||||
if (!ret)
|
||||
ret = cpufreq_apply_cooling(cpufreq_device, state);
|
||||
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
|
||||
return ret;
|
||||
return cpufreq_apply_cooling(cpufreq_device, state);
|
||||
}
|
||||
|
||||
/* Bind cpufreq callbacks to thermal cooling device ops */
|
||||
@ -345,18 +313,15 @@ static struct notifier_block thermal_cpufreq_notifier_block = {
|
||||
* @clip_cpus: cpumask of cpus where the frequency constraints will happen.
|
||||
*/
|
||||
struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
struct cpumask *clip_cpus)
|
||||
const struct cpumask *clip_cpus)
|
||||
{
|
||||
struct thermal_cooling_device *cool_dev;
|
||||
struct cpufreq_cooling_device *cpufreq_dev = NULL;
|
||||
unsigned int cpufreq_dev_count = 0, min = 0, max = 0;
|
||||
unsigned int min = 0, max = 0;
|
||||
char dev_name[THERMAL_NAME_LENGTH];
|
||||
int ret = 0, i;
|
||||
struct cpufreq_policy policy;
|
||||
|
||||
list_for_each_entry(cpufreq_dev, &cooling_cpufreq_list, node)
|
||||
cpufreq_dev_count++;
|
||||
|
||||
/*Verify that all the clip cpus have same freq_min, freq_max limit*/
|
||||
for_each_cpu(i, clip_cpus) {
|
||||
/*continue if cpufreq policy not found and not return error*/
|
||||
@ -369,7 +334,7 @@ struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
if (min != policy.cpuinfo.min_freq ||
|
||||
max != policy.cpuinfo.max_freq)
|
||||
return ERR_PTR(-EINVAL);
|
||||
}
|
||||
}
|
||||
}
|
||||
cpufreq_dev = kzalloc(sizeof(struct cpufreq_cooling_device),
|
||||
GFP_KERNEL);
|
||||
@ -378,9 +343,6 @@ struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
|
||||
cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
|
||||
|
||||
if (cpufreq_dev_count == 0)
|
||||
mutex_init(&cooling_cpufreq_lock);
|
||||
|
||||
ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);
|
||||
if (ret) {
|
||||
kfree(cpufreq_dev);
|
||||
@ -399,12 +361,12 @@ struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
cpufreq_dev->cool_dev = cool_dev;
|
||||
cpufreq_dev->cpufreq_state = 0;
|
||||
mutex_lock(&cooling_cpufreq_lock);
|
||||
list_add_tail(&cpufreq_dev->node, &cooling_cpufreq_list);
|
||||
|
||||
/* Register the notifier for first cpufreq cooling device */
|
||||
if (cpufreq_dev_count == 0)
|
||||
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
|
||||
CPUFREQ_POLICY_NOTIFIER);
|
||||
cpufreq_dev_count++;
|
||||
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
return cool_dev;
|
||||
@ -417,33 +379,20 @@ EXPORT_SYMBOL(cpufreq_cooling_register);
|
||||
*/
|
||||
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
||||
{
|
||||
struct cpufreq_cooling_device *cpufreq_dev = NULL;
|
||||
unsigned int cpufreq_dev_count = 0;
|
||||
struct cpufreq_cooling_device *cpufreq_dev = cdev->devdata;
|
||||
|
||||
mutex_lock(&cooling_cpufreq_lock);
|
||||
list_for_each_entry(cpufreq_dev, &cooling_cpufreq_list, node) {
|
||||
if (cpufreq_dev && cpufreq_dev->cool_dev == cdev)
|
||||
break;
|
||||
cpufreq_dev_count++;
|
||||
}
|
||||
|
||||
if (!cpufreq_dev || cpufreq_dev->cool_dev != cdev) {
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
return;
|
||||
}
|
||||
|
||||
list_del(&cpufreq_dev->node);
|
||||
cpufreq_dev_count--;
|
||||
|
||||
/* Unregister the notifier for the last cpufreq cooling device */
|
||||
if (cpufreq_dev_count == 1) {
|
||||
if (cpufreq_dev_count == 0) {
|
||||
cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
|
||||
CPUFREQ_POLICY_NOTIFIER);
|
||||
}
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
|
||||
thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
|
||||
release_idr(&cpufreq_idr, cpufreq_dev->id);
|
||||
if (cpufreq_dev_count == 1)
|
||||
mutex_destroy(&cooling_cpufreq_lock);
|
||||
kfree(cpufreq_dev);
|
||||
}
|
||||
EXPORT_SYMBOL(cpufreq_cooling_unregister);
|
||||
|
108
drivers/thermal/db8500_cpufreq_cooling.c
Normal file
108
drivers/thermal/db8500_cpufreq_cooling.c
Normal file
@ -0,0 +1,108 @@
|
||||
/*
|
||||
* db8500_cpufreq_cooling.c - DB8500 cpufreq works as cooling device.
|
||||
*
|
||||
* Copyright (C) 2012 ST-Ericsson
|
||||
* Copyright (C) 2012 Linaro Ltd.
|
||||
*
|
||||
* Author: Hongbo Zhang <hongbo.zhang@linaro.com>
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License as published by
|
||||
* the Free Software Foundation; either version 2 of the License, or
|
||||
* (at your option) any later version.
|
||||
*
|
||||
* This program is distributed in the hope that it will be useful,
|
||||
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||||
* GNU General Public License for more details.
|
||||
*/
|
||||
|
||||
#include <linux/cpu_cooling.h>
|
||||
#include <linux/cpufreq.h>
|
||||
#include <linux/err.h>
|
||||
#include <linux/module.h>
|
||||
#include <linux/platform_device.h>
|
||||
#include <linux/slab.h>
|
||||
|
||||
static int db8500_cpufreq_cooling_probe(struct platform_device *pdev)
|
||||
{
|
||||
struct thermal_cooling_device *cdev;
|
||||
struct cpumask mask_val;
|
||||
|
||||
/* make sure cpufreq driver has been initialized */
|
||||
if (!cpufreq_frequency_get_table(0))
|
||||
return -EPROBE_DEFER;
|
||||
|
||||
cpumask_set_cpu(0, &mask_val);
|
||||
cdev = cpufreq_cooling_register(&mask_val);
|
||||
|
||||
if (IS_ERR_OR_NULL(cdev)) {
|
||||
dev_err(&pdev->dev, "Failed to register cooling device\n");
|
||||
return PTR_ERR(cdev);
|
||||
}
|
||||
|
||||
platform_set_drvdata(pdev, cdev);
|
||||
|
||||
dev_info(&pdev->dev, "Cooling device registered: %s\n", cdev->type);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int db8500_cpufreq_cooling_remove(struct platform_device *pdev)
|
||||
{
|
||||
struct thermal_cooling_device *cdev = platform_get_drvdata(pdev);
|
||||
|
||||
cpufreq_cooling_unregister(cdev);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int db8500_cpufreq_cooling_suspend(struct platform_device *pdev,
|
||||
pm_message_t state)
|
||||
{
|
||||
return -ENOSYS;
|
||||
}
|
||||
|
||||
static int db8500_cpufreq_cooling_resume(struct platform_device *pdev)
|
||||
{
|
||||
return -ENOSYS;
|
||||
}
|
||||
|
||||
#ifdef CONFIG_OF
|
||||
static const struct of_device_id db8500_cpufreq_cooling_match[] = {
|
||||
{ .compatible = "stericsson,db8500-cpufreq-cooling" },
|
||||
{},
|
||||
};
|
||||
#else
|
||||
#define db8500_cpufreq_cooling_match NULL
|
||||
#endif
|
||||
|
||||
static struct platform_driver db8500_cpufreq_cooling_driver = {
|
||||
.driver = {
|
||||
.owner = THIS_MODULE,
|
||||
.name = "db8500-cpufreq-cooling",
|
||||
.of_match_table = db8500_cpufreq_cooling_match,
|
||||
},
|
||||
.probe = db8500_cpufreq_cooling_probe,
|
||||
.suspend = db8500_cpufreq_cooling_suspend,
|
||||
.resume = db8500_cpufreq_cooling_resume,
|
||||
.remove = db8500_cpufreq_cooling_remove,
|
||||
};
|
||||
|
||||
static int __init db8500_cpufreq_cooling_init(void)
|
||||
{
|
||||
return platform_driver_register(&db8500_cpufreq_cooling_driver);
|
||||
}
|
||||
|
||||
static void __exit db8500_cpufreq_cooling_exit(void)
|
||||
{
|
||||
platform_driver_unregister(&db8500_cpufreq_cooling_driver);
|
||||
}
|
||||
|
||||
/* Should be later than db8500_cpufreq_register */
|
||||
late_initcall(db8500_cpufreq_cooling_init);
|
||||
module_exit(db8500_cpufreq_cooling_exit);
|
||||
|
||||
MODULE_AUTHOR("Hongbo Zhang <hongbo.zhang@stericsson.com>");
|
||||
MODULE_DESCRIPTION("DB8500 cpufreq cooling driver");
|
||||
MODULE_LICENSE("GPL");
|
531
drivers/thermal/db8500_thermal.c
Normal file
531
drivers/thermal/db8500_thermal.c
Normal file
@ -0,0 +1,531 @@
|
||||
/*
|
||||
* db8500_thermal.c - DB8500 Thermal Management Implementation
|
||||
*
|
||||
* Copyright (C) 2012 ST-Ericsson
|
||||
* Copyright (C) 2012 Linaro Ltd.
|
||||
*
|
||||
* Author: Hongbo Zhang <hongbo.zhang@linaro.com>
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License as published by
|
||||
* the Free Software Foundation; either version 2 of the License, or
|
||||
* (at your option) any later version.
|
||||
*
|
||||
* This program is distributed in the hope that it will be useful,
|
||||
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||||
* GNU General Public License for more details.
|
||||
*/
|
||||
|
||||
#include <linux/cpu_cooling.h>
|
||||
#include <linux/interrupt.h>
|
||||
#include <linux/mfd/dbx500-prcmu.h>
|
||||
#include <linux/module.h>
|
||||
#include <linux/of.h>
|
||||
#include <linux/platform_data/db8500_thermal.h>
|
||||
#include <linux/platform_device.h>
|
||||
#include <linux/slab.h>
|
||||
#include <linux/thermal.h>
|
||||
|
||||
#define PRCMU_DEFAULT_MEASURE_TIME 0xFFF
|
||||
#define PRCMU_DEFAULT_LOW_TEMP 0
|
||||
|
||||
struct db8500_thermal_zone {
|
||||
struct thermal_zone_device *therm_dev;
|
||||
struct mutex th_lock;
|
||||
struct work_struct therm_work;
|
||||
struct db8500_thsens_platform_data *trip_tab;
|
||||
enum thermal_device_mode mode;
|
||||
enum thermal_trend trend;
|
||||
unsigned long cur_temp_pseudo;
|
||||
unsigned int cur_index;
|
||||
};
|
||||
|
||||
/* Local function to check if thermal zone matches cooling devices */
|
||||
static int db8500_thermal_match_cdev(struct thermal_cooling_device *cdev,
|
||||
struct db8500_trip_point *trip_point)
|
||||
{
|
||||
int i;
|
||||
|
||||
if (!strlen(cdev->type))
|
||||
return -EINVAL;
|
||||
|
||||
for (i = 0; i < COOLING_DEV_MAX; i++) {
|
||||
if (!strcmp(trip_point->cdev_name[i], cdev->type))
|
||||
return 0;
|
||||
}
|
||||
|
||||
return -ENODEV;
|
||||
}
|
||||
|
||||
/* Callback to bind cooling device to thermal zone */
|
||||
static int db8500_cdev_bind(struct thermal_zone_device *thermal,
|
||||
struct thermal_cooling_device *cdev)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = thermal->devdata;
|
||||
struct db8500_thsens_platform_data *ptrips = pzone->trip_tab;
|
||||
unsigned long max_state, upper, lower;
|
||||
int i, ret = -EINVAL;
|
||||
|
||||
cdev->ops->get_max_state(cdev, &max_state);
|
||||
|
||||
for (i = 0; i < ptrips->num_trips; i++) {
|
||||
if (db8500_thermal_match_cdev(cdev, &ptrips->trip_points[i]))
|
||||
continue;
|
||||
|
||||
upper = lower = i > max_state ? max_state : i;
|
||||
|
||||
ret = thermal_zone_bind_cooling_device(thermal, i, cdev,
|
||||
upper, lower);
|
||||
|
||||
dev_info(&cdev->device, "%s bind to %d: %d-%s\n", cdev->type,
|
||||
i, ret, ret ? "fail" : "succeed");
|
||||
}
|
||||
|
||||
return ret;
|
||||
}
|
||||
|
||||
/* Callback to unbind cooling device from thermal zone */
|
||||
static int db8500_cdev_unbind(struct thermal_zone_device *thermal,
|
||||
struct thermal_cooling_device *cdev)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = thermal->devdata;
|
||||
struct db8500_thsens_platform_data *ptrips = pzone->trip_tab;
|
||||
int i, ret = -EINVAL;
|
||||
|
||||
for (i = 0; i < ptrips->num_trips; i++) {
|
||||
if (db8500_thermal_match_cdev(cdev, &ptrips->trip_points[i]))
|
||||
continue;
|
||||
|
||||
ret = thermal_zone_unbind_cooling_device(thermal, i, cdev);
|
||||
|
||||
dev_info(&cdev->device, "%s unbind from %d: %s\n", cdev->type,
|
||||
i, ret ? "fail" : "succeed");
|
||||
}
|
||||
|
||||
return ret;
|
||||
}
|
||||
|
||||
/* Callback to get current temperature */
|
||||
static int db8500_sys_get_temp(struct thermal_zone_device *thermal,
|
||||
unsigned long *temp)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = thermal->devdata;
|
||||
|
||||
/*
|
||||
* TODO: There is no PRCMU interface to get temperature data currently,
|
||||
* so a pseudo temperature is returned , it works for thermal framework
|
||||
* and this will be fixed when the PRCMU interface is available.
|
||||
*/
|
||||
*temp = pzone->cur_temp_pseudo;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
/* Callback to get temperature changing trend */
|
||||
static int db8500_sys_get_trend(struct thermal_zone_device *thermal,
|
||||
int trip, enum thermal_trend *trend)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = thermal->devdata;
|
||||
|
||||
*trend = pzone->trend;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
/* Callback to get thermal zone mode */
|
||||
static int db8500_sys_get_mode(struct thermal_zone_device *thermal,
|
||||
enum thermal_device_mode *mode)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = thermal->devdata;
|
||||
|
||||
mutex_lock(&pzone->th_lock);
|
||||
*mode = pzone->mode;
|
||||
mutex_unlock(&pzone->th_lock);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
/* Callback to set thermal zone mode */
|
||||
static int db8500_sys_set_mode(struct thermal_zone_device *thermal,
|
||||
enum thermal_device_mode mode)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = thermal->devdata;
|
||||
|
||||
mutex_lock(&pzone->th_lock);
|
||||
|
||||
pzone->mode = mode;
|
||||
if (mode == THERMAL_DEVICE_ENABLED)
|
||||
schedule_work(&pzone->therm_work);
|
||||
|
||||
mutex_unlock(&pzone->th_lock);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
/* Callback to get trip point type */
|
||||
static int db8500_sys_get_trip_type(struct thermal_zone_device *thermal,
|
||||
int trip, enum thermal_trip_type *type)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = thermal->devdata;
|
||||
struct db8500_thsens_platform_data *ptrips = pzone->trip_tab;
|
||||
|
||||
if (trip >= ptrips->num_trips)
|
||||
return -EINVAL;
|
||||
|
||||
*type = ptrips->trip_points[trip].type;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
/* Callback to get trip point temperature */
|
||||
static int db8500_sys_get_trip_temp(struct thermal_zone_device *thermal,
|
||||
int trip, unsigned long *temp)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = thermal->devdata;
|
||||
struct db8500_thsens_platform_data *ptrips = pzone->trip_tab;
|
||||
|
||||
if (trip >= ptrips->num_trips)
|
||||
return -EINVAL;
|
||||
|
||||
*temp = ptrips->trip_points[trip].temp;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
/* Callback to get critical trip point temperature */
|
||||
static int db8500_sys_get_crit_temp(struct thermal_zone_device *thermal,
|
||||
unsigned long *temp)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = thermal->devdata;
|
||||
struct db8500_thsens_platform_data *ptrips = pzone->trip_tab;
|
||||
int i;
|
||||
|
||||
for (i = ptrips->num_trips - 1; i > 0; i--) {
|
||||
if (ptrips->trip_points[i].type == THERMAL_TRIP_CRITICAL) {
|
||||
*temp = ptrips->trip_points[i].temp;
|
||||
return 0;
|
||||
}
|
||||
}
|
||||
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
static struct thermal_zone_device_ops thdev_ops = {
|
||||
.bind = db8500_cdev_bind,
|
||||
.unbind = db8500_cdev_unbind,
|
||||
.get_temp = db8500_sys_get_temp,
|
||||
.get_trend = db8500_sys_get_trend,
|
||||
.get_mode = db8500_sys_get_mode,
|
||||
.set_mode = db8500_sys_set_mode,
|
||||
.get_trip_type = db8500_sys_get_trip_type,
|
||||
.get_trip_temp = db8500_sys_get_trip_temp,
|
||||
.get_crit_temp = db8500_sys_get_crit_temp,
|
||||
};
|
||||
|
||||
static void db8500_thermal_update_config(struct db8500_thermal_zone *pzone,
|
||||
unsigned int idx, enum thermal_trend trend,
|
||||
unsigned long next_low, unsigned long next_high)
|
||||
{
|
||||
prcmu_stop_temp_sense();
|
||||
|
||||
pzone->cur_index = idx;
|
||||
pzone->cur_temp_pseudo = (next_low + next_high)/2;
|
||||
pzone->trend = trend;
|
||||
|
||||
prcmu_config_hotmon((u8)(next_low/1000), (u8)(next_high/1000));
|
||||
prcmu_start_temp_sense(PRCMU_DEFAULT_MEASURE_TIME);
|
||||
}
|
||||
|
||||
static irqreturn_t prcmu_low_irq_handler(int irq, void *irq_data)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = irq_data;
|
||||
struct db8500_thsens_platform_data *ptrips = pzone->trip_tab;
|
||||
unsigned int idx = pzone->cur_index;
|
||||
unsigned long next_low, next_high;
|
||||
|
||||
if (unlikely(idx == 0))
|
||||
/* Meaningless for thermal management, ignoring it */
|
||||
return IRQ_HANDLED;
|
||||
|
||||
if (idx == 1) {
|
||||
next_high = ptrips->trip_points[0].temp;
|
||||
next_low = PRCMU_DEFAULT_LOW_TEMP;
|
||||
} else {
|
||||
next_high = ptrips->trip_points[idx-1].temp;
|
||||
next_low = ptrips->trip_points[idx-2].temp;
|
||||
}
|
||||
idx -= 1;
|
||||
|
||||
db8500_thermal_update_config(pzone, idx, THERMAL_TREND_DROPPING,
|
||||
next_low, next_high);
|
||||
|
||||
dev_dbg(&pzone->therm_dev->device,
|
||||
"PRCMU set max %ld, min %ld\n", next_high, next_low);
|
||||
|
||||
schedule_work(&pzone->therm_work);
|
||||
|
||||
return IRQ_HANDLED;
|
||||
}
|
||||
|
||||
static irqreturn_t prcmu_high_irq_handler(int irq, void *irq_data)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = irq_data;
|
||||
struct db8500_thsens_platform_data *ptrips = pzone->trip_tab;
|
||||
unsigned int idx = pzone->cur_index;
|
||||
unsigned long next_low, next_high;
|
||||
|
||||
if (idx < ptrips->num_trips - 1) {
|
||||
next_high = ptrips->trip_points[idx+1].temp;
|
||||
next_low = ptrips->trip_points[idx].temp;
|
||||
idx += 1;
|
||||
|
||||
db8500_thermal_update_config(pzone, idx, THERMAL_TREND_RAISING,
|
||||
next_low, next_high);
|
||||
|
||||
dev_dbg(&pzone->therm_dev->device,
|
||||
"PRCMU set max %ld, min %ld\n", next_high, next_low);
|
||||
} else if (idx == ptrips->num_trips - 1)
|
||||
pzone->cur_temp_pseudo = ptrips->trip_points[idx].temp + 1;
|
||||
|
||||
schedule_work(&pzone->therm_work);
|
||||
|
||||
return IRQ_HANDLED;
|
||||
}
|
||||
|
||||
static void db8500_thermal_work(struct work_struct *work)
|
||||
{
|
||||
enum thermal_device_mode cur_mode;
|
||||
struct db8500_thermal_zone *pzone;
|
||||
|
||||
pzone = container_of(work, struct db8500_thermal_zone, therm_work);
|
||||
|
||||
mutex_lock(&pzone->th_lock);
|
||||
cur_mode = pzone->mode;
|
||||
mutex_unlock(&pzone->th_lock);
|
||||
|
||||
if (cur_mode == THERMAL_DEVICE_DISABLED)
|
||||
return;
|
||||
|
||||
thermal_zone_device_update(pzone->therm_dev);
|
||||
dev_dbg(&pzone->therm_dev->device, "thermal work finished.\n");
|
||||
}
|
||||
|
||||
#ifdef CONFIG_OF
|
||||
static struct db8500_thsens_platform_data*
|
||||
db8500_thermal_parse_dt(struct platform_device *pdev)
|
||||
{
|
||||
struct db8500_thsens_platform_data *ptrips;
|
||||
struct device_node *np = pdev->dev.of_node;
|
||||
char prop_name[32];
|
||||
const char *tmp_str;
|
||||
u32 tmp_data;
|
||||
int i, j;
|
||||
|
||||
ptrips = devm_kzalloc(&pdev->dev, sizeof(*ptrips), GFP_KERNEL);
|
||||
if (!ptrips)
|
||||
return NULL;
|
||||
|
||||
if (of_property_read_u32(np, "num-trips", &tmp_data))
|
||||
goto err_parse_dt;
|
||||
|
||||
if (tmp_data > THERMAL_MAX_TRIPS)
|
||||
goto err_parse_dt;
|
||||
|
||||
ptrips->num_trips = tmp_data;
|
||||
|
||||
for (i = 0; i < ptrips->num_trips; i++) {
|
||||
sprintf(prop_name, "trip%d-temp", i);
|
||||
if (of_property_read_u32(np, prop_name, &tmp_data))
|
||||
goto err_parse_dt;
|
||||
|
||||
ptrips->trip_points[i].temp = tmp_data;
|
||||
|
||||
sprintf(prop_name, "trip%d-type", i);
|
||||
if (of_property_read_string(np, prop_name, &tmp_str))
|
||||
goto err_parse_dt;
|
||||
|
||||
if (!strcmp(tmp_str, "active"))
|
||||
ptrips->trip_points[i].type = THERMAL_TRIP_ACTIVE;
|
||||
else if (!strcmp(tmp_str, "passive"))
|
||||
ptrips->trip_points[i].type = THERMAL_TRIP_PASSIVE;
|
||||
else if (!strcmp(tmp_str, "hot"))
|
||||
ptrips->trip_points[i].type = THERMAL_TRIP_HOT;
|
||||
else if (!strcmp(tmp_str, "critical"))
|
||||
ptrips->trip_points[i].type = THERMAL_TRIP_CRITICAL;
|
||||
else
|
||||
goto err_parse_dt;
|
||||
|
||||
sprintf(prop_name, "trip%d-cdev-num", i);
|
||||
if (of_property_read_u32(np, prop_name, &tmp_data))
|
||||
goto err_parse_dt;
|
||||
|
||||
if (tmp_data > COOLING_DEV_MAX)
|
||||
goto err_parse_dt;
|
||||
|
||||
for (j = 0; j < tmp_data; j++) {
|
||||
sprintf(prop_name, "trip%d-cdev-name%d", i, j);
|
||||
if (of_property_read_string(np, prop_name, &tmp_str))
|
||||
goto err_parse_dt;
|
||||
|
||||
if (strlen(tmp_str) >= THERMAL_NAME_LENGTH)
|
||||
goto err_parse_dt;
|
||||
|
||||
strcpy(ptrips->trip_points[i].cdev_name[j], tmp_str);
|
||||
}
|
||||
}
|
||||
return ptrips;
|
||||
|
||||
err_parse_dt:
|
||||
dev_err(&pdev->dev, "Parsing device tree data error.\n");
|
||||
return NULL;
|
||||
}
|
||||
#else
|
||||
static inline struct db8500_thsens_platform_data*
|
||||
db8500_thermal_parse_dt(struct platform_device *pdev)
|
||||
{
|
||||
return NULL;
|
||||
}
|
||||
#endif
|
||||
|
||||
static int db8500_thermal_probe(struct platform_device *pdev)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = NULL;
|
||||
struct db8500_thsens_platform_data *ptrips = NULL;
|
||||
struct device_node *np = pdev->dev.of_node;
|
||||
int low_irq, high_irq, ret = 0;
|
||||
unsigned long dft_low, dft_high;
|
||||
|
||||
if (np)
|
||||
ptrips = db8500_thermal_parse_dt(pdev);
|
||||
else
|
||||
ptrips = dev_get_platdata(&pdev->dev);
|
||||
|
||||
if (!ptrips)
|
||||
return -EINVAL;
|
||||
|
||||
pzone = devm_kzalloc(&pdev->dev, sizeof(*pzone), GFP_KERNEL);
|
||||
if (!pzone)
|
||||
return -ENOMEM;
|
||||
|
||||
mutex_init(&pzone->th_lock);
|
||||
mutex_lock(&pzone->th_lock);
|
||||
|
||||
pzone->mode = THERMAL_DEVICE_DISABLED;
|
||||
pzone->trip_tab = ptrips;
|
||||
|
||||
INIT_WORK(&pzone->therm_work, db8500_thermal_work);
|
||||
|
||||
low_irq = platform_get_irq_byname(pdev, "IRQ_HOTMON_LOW");
|
||||
if (low_irq < 0) {
|
||||
dev_err(&pdev->dev, "Get IRQ_HOTMON_LOW failed.\n");
|
||||
return low_irq;
|
||||
}
|
||||
|
||||
ret = devm_request_threaded_irq(&pdev->dev, low_irq, NULL,
|
||||
prcmu_low_irq_handler, IRQF_NO_SUSPEND | IRQF_ONESHOT,
|
||||
"dbx500_temp_low", pzone);
|
||||
if (ret < 0) {
|
||||
dev_err(&pdev->dev, "Failed to allocate temp low irq.\n");
|
||||
return ret;
|
||||
}
|
||||
|
||||
high_irq = platform_get_irq_byname(pdev, "IRQ_HOTMON_HIGH");
|
||||
if (high_irq < 0) {
|
||||
dev_err(&pdev->dev, "Get IRQ_HOTMON_HIGH failed.\n");
|
||||
return high_irq;
|
||||
}
|
||||
|
||||
ret = devm_request_threaded_irq(&pdev->dev, high_irq, NULL,
|
||||
prcmu_high_irq_handler, IRQF_NO_SUSPEND | IRQF_ONESHOT,
|
||||
"dbx500_temp_high", pzone);
|
||||
if (ret < 0) {
|
||||
dev_err(&pdev->dev, "Failed to allocate temp high irq.\n");
|
||||
return ret;
|
||||
}
|
||||
|
||||
pzone->therm_dev = thermal_zone_device_register("db8500_thermal_zone",
|
||||
ptrips->num_trips, 0, pzone, &thdev_ops, NULL, 0, 0);
|
||||
|
||||
if (IS_ERR_OR_NULL(pzone->therm_dev)) {
|
||||
dev_err(&pdev->dev, "Register thermal zone device failed.\n");
|
||||
return PTR_ERR(pzone->therm_dev);
|
||||
}
|
||||
dev_info(&pdev->dev, "Thermal zone device registered.\n");
|
||||
|
||||
dft_low = PRCMU_DEFAULT_LOW_TEMP;
|
||||
dft_high = ptrips->trip_points[0].temp;
|
||||
|
||||
db8500_thermal_update_config(pzone, 0, THERMAL_TREND_STABLE,
|
||||
dft_low, dft_high);
|
||||
|
||||
platform_set_drvdata(pdev, pzone);
|
||||
pzone->mode = THERMAL_DEVICE_ENABLED;
|
||||
mutex_unlock(&pzone->th_lock);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int db8500_thermal_remove(struct platform_device *pdev)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = platform_get_drvdata(pdev);
|
||||
|
||||
thermal_zone_device_unregister(pzone->therm_dev);
|
||||
cancel_work_sync(&pzone->therm_work);
|
||||
mutex_destroy(&pzone->th_lock);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int db8500_thermal_suspend(struct platform_device *pdev,
|
||||
pm_message_t state)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = platform_get_drvdata(pdev);
|
||||
|
||||
flush_work(&pzone->therm_work);
|
||||
prcmu_stop_temp_sense();
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int db8500_thermal_resume(struct platform_device *pdev)
|
||||
{
|
||||
struct db8500_thermal_zone *pzone = platform_get_drvdata(pdev);
|
||||
struct db8500_thsens_platform_data *ptrips = pzone->trip_tab;
|
||||
unsigned long dft_low, dft_high;
|
||||
|
||||
dft_low = PRCMU_DEFAULT_LOW_TEMP;
|
||||
dft_high = ptrips->trip_points[0].temp;
|
||||
|
||||
db8500_thermal_update_config(pzone, 0, THERMAL_TREND_STABLE,
|
||||
dft_low, dft_high);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
#ifdef CONFIG_OF
|
||||
static const struct of_device_id db8500_thermal_match[] = {
|
||||
{ .compatible = "stericsson,db8500-thermal" },
|
||||
{},
|
||||
};
|
||||
#else
|
||||
#define db8500_thermal_match NULL
|
||||
#endif
|
||||
|
||||
static struct platform_driver db8500_thermal_driver = {
|
||||
.driver = {
|
||||
.owner = THIS_MODULE,
|
||||
.name = "db8500-thermal",
|
||||
.of_match_table = db8500_thermal_match,
|
||||
},
|
||||
.probe = db8500_thermal_probe,
|
||||
.suspend = db8500_thermal_suspend,
|
||||
.resume = db8500_thermal_resume,
|
||||
.remove = db8500_thermal_remove,
|
||||
};
|
||||
|
||||
module_platform_driver(db8500_thermal_driver);
|
||||
|
||||
MODULE_AUTHOR("Hongbo Zhang <hongbo.zhang@stericsson.com>");
|
||||
MODULE_DESCRIPTION("DB8500 thermal driver");
|
||||
MODULE_LICENSE("GPL");
|
@ -451,7 +451,7 @@ static int exynos_register_thermal(struct thermal_sensor_conf *sensor_conf)
|
||||
th_zone->cool_dev_size++;
|
||||
|
||||
th_zone->therm_dev = thermal_zone_device_register(sensor_conf->name,
|
||||
EXYNOS_ZONE_COUNT, 0, NULL, &exynos_dev_ops, 0,
|
||||
EXYNOS_ZONE_COUNT, 0, NULL, &exynos_dev_ops, NULL, 0,
|
||||
IDLE_INTERVAL);
|
||||
|
||||
if (IS_ERR(th_zone->therm_dev)) {
|
||||
|
133
drivers/thermal/fair_share.c
Normal file
133
drivers/thermal/fair_share.c
Normal file
@ -0,0 +1,133 @@
|
||||
/*
|
||||
* fair_share.c - A simple weight based Thermal governor
|
||||
*
|
||||
* Copyright (C) 2012 Intel Corp
|
||||
* Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com>
|
||||
*
|
||||
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License as published by
|
||||
* the Free Software Foundation; version 2 of the License.
|
||||
*
|
||||
* This program is distributed in the hope that it will be useful, but
|
||||
* WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
||||
* General Public License for more details.
|
||||
*
|
||||
* You should have received a copy of the GNU General Public License along
|
||||
* with this program; if not, write to the Free Software Foundation, Inc.,
|
||||
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
|
||||
*
|
||||
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
*/
|
||||
|
||||
#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
|
||||
|
||||
#include <linux/module.h>
|
||||
#include <linux/thermal.h>
|
||||
|
||||
#include "thermal_core.h"
|
||||
|
||||
/**
|
||||
* get_trip_level: - obtains the current trip level for a zone
|
||||
* @tz: thermal zone device
|
||||
*/
|
||||
static int get_trip_level(struct thermal_zone_device *tz)
|
||||
{
|
||||
int count = 0;
|
||||
unsigned long trip_temp;
|
||||
|
||||
if (tz->trips == 0 || !tz->ops->get_trip_temp)
|
||||
return 0;
|
||||
|
||||
for (count = 0; count < tz->trips; count++) {
|
||||
tz->ops->get_trip_temp(tz, count, &trip_temp);
|
||||
if (tz->temperature < trip_temp)
|
||||
break;
|
||||
}
|
||||
return count;
|
||||
}
|
||||
|
||||
static long get_target_state(struct thermal_zone_device *tz,
|
||||
struct thermal_cooling_device *cdev, int weight, int level)
|
||||
{
|
||||
unsigned long max_state;
|
||||
|
||||
cdev->ops->get_max_state(cdev, &max_state);
|
||||
|
||||
return (long)(weight * level * max_state) / (100 * tz->trips);
|
||||
}
|
||||
|
||||
/**
|
||||
* fair_share_throttle - throttles devices asscciated with the given zone
|
||||
* @tz - thermal_zone_device
|
||||
*
|
||||
* Throttling Logic: This uses three parameters to calculate the new
|
||||
* throttle state of the cooling devices associated with the given zone.
|
||||
*
|
||||
* Parameters used for Throttling:
|
||||
* P1. max_state: Maximum throttle state exposed by the cooling device.
|
||||
* P2. weight[i]/100:
|
||||
* How 'effective' the 'i'th device is, in cooling the given zone.
|
||||
* P3. cur_trip_level/max_no_of_trips:
|
||||
* This describes the extent to which the devices should be throttled.
|
||||
* We do not want to throttle too much when we trip a lower temperature,
|
||||
* whereas the throttling is at full swing if we trip critical levels.
|
||||
* (Heavily assumes the trip points are in ascending order)
|
||||
* new_state of cooling device = P3 * P2 * P1
|
||||
*/
|
||||
static int fair_share_throttle(struct thermal_zone_device *tz, int trip)
|
||||
{
|
||||
const struct thermal_zone_params *tzp;
|
||||
struct thermal_cooling_device *cdev;
|
||||
struct thermal_instance *instance;
|
||||
int i;
|
||||
int cur_trip_level = get_trip_level(tz);
|
||||
|
||||
if (!tz->tzp || !tz->tzp->tbp)
|
||||
return -EINVAL;
|
||||
|
||||
tzp = tz->tzp;
|
||||
|
||||
for (i = 0; i < tzp->num_tbps; i++) {
|
||||
if (!tzp->tbp[i].cdev)
|
||||
continue;
|
||||
|
||||
cdev = tzp->tbp[i].cdev;
|
||||
instance = get_thermal_instance(tz, cdev, trip);
|
||||
if (!instance)
|
||||
continue;
|
||||
|
||||
instance->target = get_target_state(tz, cdev,
|
||||
tzp->tbp[i].weight, cur_trip_level);
|
||||
|
||||
instance->cdev->updated = false;
|
||||
thermal_cdev_update(cdev);
|
||||
}
|
||||
return 0;
|
||||
}
|
||||
|
||||
static struct thermal_governor thermal_gov_fair_share = {
|
||||
.name = "fair_share",
|
||||
.throttle = fair_share_throttle,
|
||||
.owner = THIS_MODULE,
|
||||
};
|
||||
|
||||
static int __init thermal_gov_fair_share_init(void)
|
||||
{
|
||||
return thermal_register_governor(&thermal_gov_fair_share);
|
||||
}
|
||||
|
||||
static void __exit thermal_gov_fair_share_exit(void)
|
||||
{
|
||||
thermal_unregister_governor(&thermal_gov_fair_share);
|
||||
}
|
||||
|
||||
/* This should load after thermal framework */
|
||||
fs_initcall(thermal_gov_fair_share_init);
|
||||
module_exit(thermal_gov_fair_share_exit);
|
||||
|
||||
MODULE_AUTHOR("Durgadoss R");
|
||||
MODULE_DESCRIPTION("A simple weight based thermal throttling governor");
|
||||
MODULE_LICENSE("GPL");
|
@ -43,6 +43,9 @@ struct rcar_thermal_priv {
|
||||
u32 comp;
|
||||
};
|
||||
|
||||
#define MCELSIUS(temp) ((temp) * 1000)
|
||||
#define rcar_zone_to_priv(zone) (zone->devdata)
|
||||
|
||||
/*
|
||||
* basic functions
|
||||
*/
|
||||
@ -96,7 +99,7 @@ static void rcar_thermal_bset(struct rcar_thermal_priv *priv, u32 reg,
|
||||
static int rcar_thermal_get_temp(struct thermal_zone_device *zone,
|
||||
unsigned long *temp)
|
||||
{
|
||||
struct rcar_thermal_priv *priv = zone->devdata;
|
||||
struct rcar_thermal_priv *priv = rcar_zone_to_priv(zone);
|
||||
int val, min, max, tmp;
|
||||
|
||||
tmp = -200; /* default */
|
||||
@ -169,7 +172,7 @@ static int rcar_thermal_get_temp(struct thermal_zone_device *zone,
|
||||
}
|
||||
}
|
||||
|
||||
*temp = tmp;
|
||||
*temp = MCELSIUS(tmp);
|
||||
return 0;
|
||||
}
|
||||
|
||||
@ -185,7 +188,6 @@ static int rcar_thermal_probe(struct platform_device *pdev)
|
||||
struct thermal_zone_device *zone;
|
||||
struct rcar_thermal_priv *priv;
|
||||
struct resource *res;
|
||||
int ret;
|
||||
|
||||
res = platform_get_resource(pdev, IORESOURCE_MEM, 0);
|
||||
if (!res) {
|
||||
@ -206,16 +208,14 @@ static int rcar_thermal_probe(struct platform_device *pdev)
|
||||
res->start, resource_size(res));
|
||||
if (!priv->base) {
|
||||
dev_err(&pdev->dev, "Unable to ioremap thermal register\n");
|
||||
ret = -ENOMEM;
|
||||
goto error_free_priv;
|
||||
return -ENOMEM;
|
||||
}
|
||||
|
||||
zone = thermal_zone_device_register("rcar_thermal", 0, 0, priv,
|
||||
&rcar_thermal_zone_ops, 0, 0);
|
||||
&rcar_thermal_zone_ops, NULL, 0, 0);
|
||||
if (IS_ERR(zone)) {
|
||||
dev_err(&pdev->dev, "thermal zone device is NULL\n");
|
||||
ret = PTR_ERR(zone);
|
||||
goto error_iounmap;
|
||||
return PTR_ERR(zone);
|
||||
}
|
||||
|
||||
platform_set_drvdata(pdev, zone);
|
||||
@ -223,26 +223,15 @@ static int rcar_thermal_probe(struct platform_device *pdev)
|
||||
dev_info(&pdev->dev, "proved\n");
|
||||
|
||||
return 0;
|
||||
|
||||
error_iounmap:
|
||||
devm_iounmap(&pdev->dev, priv->base);
|
||||
error_free_priv:
|
||||
devm_kfree(&pdev->dev, priv);
|
||||
|
||||
return ret;
|
||||
}
|
||||
|
||||
static int rcar_thermal_remove(struct platform_device *pdev)
|
||||
{
|
||||
struct thermal_zone_device *zone = platform_get_drvdata(pdev);
|
||||
struct rcar_thermal_priv *priv = zone->devdata;
|
||||
|
||||
thermal_zone_device_unregister(zone);
|
||||
platform_set_drvdata(pdev, NULL);
|
||||
|
||||
devm_iounmap(&pdev->dev, priv->base);
|
||||
devm_kfree(&pdev->dev, priv);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
|
@ -147,7 +147,7 @@ static int spear_thermal_probe(struct platform_device *pdev)
|
||||
writel_relaxed(stdev->flags, stdev->thermal_base);
|
||||
|
||||
spear_thermal = thermal_zone_device_register("spear_thermal", 0, 0,
|
||||
stdev, &ops, 0, 0);
|
||||
stdev, &ops, NULL, 0, 0);
|
||||
if (IS_ERR(spear_thermal)) {
|
||||
dev_err(&pdev->dev, "thermal zone device is NULL\n");
|
||||
ret = PTR_ERR(spear_thermal);
|
||||
|
194
drivers/thermal/step_wise.c
Normal file
194
drivers/thermal/step_wise.c
Normal file
@ -0,0 +1,194 @@
|
||||
/*
|
||||
* step_wise.c - A step-by-step Thermal throttling governor
|
||||
*
|
||||
* Copyright (C) 2012 Intel Corp
|
||||
* Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com>
|
||||
*
|
||||
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License as published by
|
||||
* the Free Software Foundation; version 2 of the License.
|
||||
*
|
||||
* This program is distributed in the hope that it will be useful, but
|
||||
* WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
||||
* General Public License for more details.
|
||||
*
|
||||
* You should have received a copy of the GNU General Public License along
|
||||
* with this program; if not, write to the Free Software Foundation, Inc.,
|
||||
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
|
||||
*
|
||||
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
*/
|
||||
|
||||
#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
|
||||
|
||||
#include <linux/module.h>
|
||||
#include <linux/thermal.h>
|
||||
|
||||
#include "thermal_core.h"
|
||||
|
||||
/*
|
||||
* If the temperature is higher than a trip point,
|
||||
* a. if the trend is THERMAL_TREND_RAISING, use higher cooling
|
||||
* state for this trip point
|
||||
* b. if the trend is THERMAL_TREND_DROPPING, use lower cooling
|
||||
* state for this trip point
|
||||
*/
|
||||
static unsigned long get_target_state(struct thermal_instance *instance,
|
||||
enum thermal_trend trend)
|
||||
{
|
||||
struct thermal_cooling_device *cdev = instance->cdev;
|
||||
unsigned long cur_state;
|
||||
|
||||
cdev->ops->get_cur_state(cdev, &cur_state);
|
||||
|
||||
if (trend == THERMAL_TREND_RAISING) {
|
||||
cur_state = cur_state < instance->upper ?
|
||||
(cur_state + 1) : instance->upper;
|
||||
} else if (trend == THERMAL_TREND_DROPPING) {
|
||||
cur_state = cur_state > instance->lower ?
|
||||
(cur_state - 1) : instance->lower;
|
||||
}
|
||||
|
||||
return cur_state;
|
||||
}
|
||||
|
||||
static void update_passive_instance(struct thermal_zone_device *tz,
|
||||
enum thermal_trip_type type, int value)
|
||||
{
|
||||
/*
|
||||
* If value is +1, activate a passive instance.
|
||||
* If value is -1, deactivate a passive instance.
|
||||
*/
|
||||
if (type == THERMAL_TRIP_PASSIVE || type == THERMAL_TRIPS_NONE)
|
||||
tz->passive += value;
|
||||
}
|
||||
|
||||
static void update_instance_for_throttle(struct thermal_zone_device *tz,
|
||||
int trip, enum thermal_trip_type trip_type,
|
||||
enum thermal_trend trend)
|
||||
{
|
||||
struct thermal_instance *instance;
|
||||
|
||||
list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
|
||||
if (instance->trip != trip)
|
||||
continue;
|
||||
|
||||
instance->target = get_target_state(instance, trend);
|
||||
|
||||
/* Activate a passive thermal instance */
|
||||
if (instance->target == THERMAL_NO_TARGET)
|
||||
update_passive_instance(tz, trip_type, 1);
|
||||
|
||||
instance->cdev->updated = false; /* cdev needs update */
|
||||
}
|
||||
}
|
||||
|
||||
static void update_instance_for_dethrottle(struct thermal_zone_device *tz,
|
||||
int trip, enum thermal_trip_type trip_type)
|
||||
{
|
||||
struct thermal_instance *instance;
|
||||
struct thermal_cooling_device *cdev;
|
||||
unsigned long cur_state;
|
||||
|
||||
list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
|
||||
if (instance->trip != trip ||
|
||||
instance->target == THERMAL_NO_TARGET)
|
||||
continue;
|
||||
|
||||
cdev = instance->cdev;
|
||||
cdev->ops->get_cur_state(cdev, &cur_state);
|
||||
|
||||
instance->target = cur_state > instance->lower ?
|
||||
(cur_state - 1) : THERMAL_NO_TARGET;
|
||||
|
||||
/* Deactivate a passive thermal instance */
|
||||
if (instance->target == THERMAL_NO_TARGET)
|
||||
update_passive_instance(tz, trip_type, -1);
|
||||
|
||||
cdev->updated = false; /* cdev needs update */
|
||||
}
|
||||
}
|
||||
|
||||
static void thermal_zone_trip_update(struct thermal_zone_device *tz, int trip)
|
||||
{
|
||||
long trip_temp;
|
||||
enum thermal_trip_type trip_type;
|
||||
enum thermal_trend trend;
|
||||
|
||||
if (trip == THERMAL_TRIPS_NONE) {
|
||||
trip_temp = tz->forced_passive;
|
||||
trip_type = THERMAL_TRIPS_NONE;
|
||||
} else {
|
||||
tz->ops->get_trip_temp(tz, trip, &trip_temp);
|
||||
tz->ops->get_trip_type(tz, trip, &trip_type);
|
||||
}
|
||||
|
||||
trend = get_tz_trend(tz, trip);
|
||||
|
||||
mutex_lock(&tz->lock);
|
||||
|
||||
if (tz->temperature >= trip_temp)
|
||||
update_instance_for_throttle(tz, trip, trip_type, trend);
|
||||
else
|
||||
update_instance_for_dethrottle(tz, trip, trip_type);
|
||||
|
||||
mutex_unlock(&tz->lock);
|
||||
}
|
||||
|
||||
/**
|
||||
* step_wise_throttle - throttles devices asscciated with the given zone
|
||||
* @tz - thermal_zone_device
|
||||
* @trip - the trip point
|
||||
* @trip_type - type of the trip point
|
||||
*
|
||||
* Throttling Logic: This uses the trend of the thermal zone to throttle.
|
||||
* If the thermal zone is 'heating up' this throttles all the cooling
|
||||
* devices associated with the zone and its particular trip point, by one
|
||||
* step. If the zone is 'cooling down' it brings back the performance of
|
||||
* the devices by one step.
|
||||
*/
|
||||
static int step_wise_throttle(struct thermal_zone_device *tz, int trip)
|
||||
{
|
||||
struct thermal_instance *instance;
|
||||
|
||||
thermal_zone_trip_update(tz, trip);
|
||||
|
||||
if (tz->forced_passive)
|
||||
thermal_zone_trip_update(tz, THERMAL_TRIPS_NONE);
|
||||
|
||||
mutex_lock(&tz->lock);
|
||||
|
||||
list_for_each_entry(instance, &tz->thermal_instances, tz_node)
|
||||
thermal_cdev_update(instance->cdev);
|
||||
|
||||
mutex_unlock(&tz->lock);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static struct thermal_governor thermal_gov_step_wise = {
|
||||
.name = "step_wise",
|
||||
.throttle = step_wise_throttle,
|
||||
.owner = THIS_MODULE,
|
||||
};
|
||||
|
||||
static int __init thermal_gov_step_wise_init(void)
|
||||
{
|
||||
return thermal_register_governor(&thermal_gov_step_wise);
|
||||
}
|
||||
|
||||
static void __exit thermal_gov_step_wise_exit(void)
|
||||
{
|
||||
thermal_unregister_governor(&thermal_gov_step_wise);
|
||||
}
|
||||
|
||||
/* This should load after thermal framework */
|
||||
fs_initcall(thermal_gov_step_wise_init);
|
||||
module_exit(thermal_gov_step_wise_exit);
|
||||
|
||||
MODULE_AUTHOR("Durgadoss R");
|
||||
MODULE_DESCRIPTION("A step-by-step thermal throttling governor");
|
||||
MODULE_LICENSE("GPL");
|
53
drivers/thermal/thermal_core.h
Normal file
53
drivers/thermal/thermal_core.h
Normal file
@ -0,0 +1,53 @@
|
||||
/*
|
||||
* thermal_core.h
|
||||
*
|
||||
* Copyright (C) 2012 Intel Corp
|
||||
* Author: Durgadoss R <durgadoss.r@intel.com>
|
||||
*
|
||||
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License as published by
|
||||
* the Free Software Foundation; version 2 of the License.
|
||||
*
|
||||
* This program is distributed in the hope that it will be useful, but
|
||||
* WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
||||
* General Public License for more details.
|
||||
*
|
||||
* You should have received a copy of the GNU General Public License along
|
||||
* with this program; if not, write to the Free Software Foundation, Inc.,
|
||||
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
|
||||
*
|
||||
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
*/
|
||||
|
||||
#ifndef __THERMAL_CORE_H__
|
||||
#define __THERMAL_CORE_H__
|
||||
|
||||
#include <linux/device.h>
|
||||
#include <linux/thermal.h>
|
||||
|
||||
/* Initial state of a cooling device during binding */
|
||||
#define THERMAL_NO_TARGET -1UL
|
||||
|
||||
/*
|
||||
* This structure is used to describe the behavior of
|
||||
* a certain cooling device on a certain trip point
|
||||
* in a certain thermal zone
|
||||
*/
|
||||
struct thermal_instance {
|
||||
int id;
|
||||
char name[THERMAL_NAME_LENGTH];
|
||||
struct thermal_zone_device *tz;
|
||||
struct thermal_cooling_device *cdev;
|
||||
int trip;
|
||||
unsigned long upper; /* Highest cooling state for this trip point */
|
||||
unsigned long lower; /* Lowest cooling state for this trip point */
|
||||
unsigned long target; /* expected cooling state */
|
||||
char attr_name[THERMAL_NAME_LENGTH];
|
||||
struct device_attribute attr;
|
||||
struct list_head tz_node; /* node in tz->thermal_instances */
|
||||
struct list_head cdev_node; /* node in cdev->thermal_instances */
|
||||
};
|
||||
|
||||
#endif /* __THERMAL_CORE_H__ */
|
@ -37,38 +37,98 @@
|
||||
#include <net/netlink.h>
|
||||
#include <net/genetlink.h>
|
||||
|
||||
#include "thermal_core.h"
|
||||
|
||||
MODULE_AUTHOR("Zhang Rui");
|
||||
MODULE_DESCRIPTION("Generic thermal management sysfs support");
|
||||
MODULE_LICENSE("GPL");
|
||||
|
||||
#define THERMAL_NO_TARGET -1UL
|
||||
/*
|
||||
* This structure is used to describe the behavior of
|
||||
* a certain cooling device on a certain trip point
|
||||
* in a certain thermal zone
|
||||
*/
|
||||
struct thermal_instance {
|
||||
int id;
|
||||
char name[THERMAL_NAME_LENGTH];
|
||||
struct thermal_zone_device *tz;
|
||||
struct thermal_cooling_device *cdev;
|
||||
int trip;
|
||||
unsigned long upper; /* Highest cooling state for this trip point */
|
||||
unsigned long lower; /* Lowest cooling state for this trip point */
|
||||
unsigned long target; /* expected cooling state */
|
||||
char attr_name[THERMAL_NAME_LENGTH];
|
||||
struct device_attribute attr;
|
||||
struct list_head tz_node; /* node in tz->thermal_instances */
|
||||
struct list_head cdev_node; /* node in cdev->thermal_instances */
|
||||
};
|
||||
|
||||
static DEFINE_IDR(thermal_tz_idr);
|
||||
static DEFINE_IDR(thermal_cdev_idr);
|
||||
static DEFINE_MUTEX(thermal_idr_lock);
|
||||
|
||||
static LIST_HEAD(thermal_tz_list);
|
||||
static LIST_HEAD(thermal_cdev_list);
|
||||
static LIST_HEAD(thermal_governor_list);
|
||||
|
||||
static DEFINE_MUTEX(thermal_list_lock);
|
||||
static DEFINE_MUTEX(thermal_governor_lock);
|
||||
|
||||
static struct thermal_governor *__find_governor(const char *name)
|
||||
{
|
||||
struct thermal_governor *pos;
|
||||
|
||||
list_for_each_entry(pos, &thermal_governor_list, governor_list)
|
||||
if (!strnicmp(name, pos->name, THERMAL_NAME_LENGTH))
|
||||
return pos;
|
||||
|
||||
return NULL;
|
||||
}
|
||||
|
||||
int thermal_register_governor(struct thermal_governor *governor)
|
||||
{
|
||||
int err;
|
||||
const char *name;
|
||||
struct thermal_zone_device *pos;
|
||||
|
||||
if (!governor)
|
||||
return -EINVAL;
|
||||
|
||||
mutex_lock(&thermal_governor_lock);
|
||||
|
||||
err = -EBUSY;
|
||||
if (__find_governor(governor->name) == NULL) {
|
||||
err = 0;
|
||||
list_add(&governor->governor_list, &thermal_governor_list);
|
||||
}
|
||||
|
||||
mutex_lock(&thermal_list_lock);
|
||||
|
||||
list_for_each_entry(pos, &thermal_tz_list, node) {
|
||||
if (pos->governor)
|
||||
continue;
|
||||
if (pos->tzp)
|
||||
name = pos->tzp->governor_name;
|
||||
else
|
||||
name = DEFAULT_THERMAL_GOVERNOR;
|
||||
if (!strnicmp(name, governor->name, THERMAL_NAME_LENGTH))
|
||||
pos->governor = governor;
|
||||
}
|
||||
|
||||
mutex_unlock(&thermal_list_lock);
|
||||
mutex_unlock(&thermal_governor_lock);
|
||||
|
||||
return err;
|
||||
}
|
||||
EXPORT_SYMBOL_GPL(thermal_register_governor);
|
||||
|
||||
void thermal_unregister_governor(struct thermal_governor *governor)
|
||||
{
|
||||
struct thermal_zone_device *pos;
|
||||
|
||||
if (!governor)
|
||||
return;
|
||||
|
||||
mutex_lock(&thermal_governor_lock);
|
||||
|
||||
if (__find_governor(governor->name) == NULL)
|
||||
goto exit;
|
||||
|
||||
mutex_lock(&thermal_list_lock);
|
||||
|
||||
list_for_each_entry(pos, &thermal_tz_list, node) {
|
||||
if (!strnicmp(pos->governor->name, governor->name,
|
||||
THERMAL_NAME_LENGTH))
|
||||
pos->governor = NULL;
|
||||
}
|
||||
|
||||
mutex_unlock(&thermal_list_lock);
|
||||
list_del(&governor->governor_list);
|
||||
exit:
|
||||
mutex_unlock(&thermal_governor_lock);
|
||||
return;
|
||||
}
|
||||
EXPORT_SYMBOL_GPL(thermal_unregister_governor);
|
||||
|
||||
static int get_idr(struct idr *idr, struct mutex *lock, int *id)
|
||||
{
|
||||
@ -101,6 +161,262 @@ static void release_idr(struct idr *idr, struct mutex *lock, int id)
|
||||
mutex_unlock(lock);
|
||||
}
|
||||
|
||||
int get_tz_trend(struct thermal_zone_device *tz, int trip)
|
||||
{
|
||||
enum thermal_trend trend;
|
||||
|
||||
if (!tz->ops->get_trend || tz->ops->get_trend(tz, trip, &trend)) {
|
||||
if (tz->temperature > tz->last_temperature)
|
||||
trend = THERMAL_TREND_RAISING;
|
||||
else if (tz->temperature < tz->last_temperature)
|
||||
trend = THERMAL_TREND_DROPPING;
|
||||
else
|
||||
trend = THERMAL_TREND_STABLE;
|
||||
}
|
||||
|
||||
return trend;
|
||||
}
|
||||
EXPORT_SYMBOL(get_tz_trend);
|
||||
|
||||
struct thermal_instance *get_thermal_instance(struct thermal_zone_device *tz,
|
||||
struct thermal_cooling_device *cdev, int trip)
|
||||
{
|
||||
struct thermal_instance *pos = NULL;
|
||||
struct thermal_instance *target_instance = NULL;
|
||||
|
||||
mutex_lock(&tz->lock);
|
||||
mutex_lock(&cdev->lock);
|
||||
|
||||
list_for_each_entry(pos, &tz->thermal_instances, tz_node) {
|
||||
if (pos->tz == tz && pos->trip == trip && pos->cdev == cdev) {
|
||||
target_instance = pos;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
mutex_unlock(&cdev->lock);
|
||||
mutex_unlock(&tz->lock);
|
||||
|
||||
return target_instance;
|
||||
}
|
||||
EXPORT_SYMBOL(get_thermal_instance);
|
||||
|
||||
static void print_bind_err_msg(struct thermal_zone_device *tz,
|
||||
struct thermal_cooling_device *cdev, int ret)
|
||||
{
|
||||
dev_err(&tz->device, "binding zone %s with cdev %s failed:%d\n",
|
||||
tz->type, cdev->type, ret);
|
||||
}
|
||||
|
||||
static void __bind(struct thermal_zone_device *tz, int mask,
|
||||
struct thermal_cooling_device *cdev)
|
||||
{
|
||||
int i, ret;
|
||||
|
||||
for (i = 0; i < tz->trips; i++) {
|
||||
if (mask & (1 << i)) {
|
||||
ret = thermal_zone_bind_cooling_device(tz, i, cdev,
|
||||
THERMAL_NO_LIMIT, THERMAL_NO_LIMIT);
|
||||
if (ret)
|
||||
print_bind_err_msg(tz, cdev, ret);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
static void __unbind(struct thermal_zone_device *tz, int mask,
|
||||
struct thermal_cooling_device *cdev)
|
||||
{
|
||||
int i;
|
||||
|
||||
for (i = 0; i < tz->trips; i++)
|
||||
if (mask & (1 << i))
|
||||
thermal_zone_unbind_cooling_device(tz, i, cdev);
|
||||
}
|
||||
|
||||
static void bind_cdev(struct thermal_cooling_device *cdev)
|
||||
{
|
||||
int i, ret;
|
||||
const struct thermal_zone_params *tzp;
|
||||
struct thermal_zone_device *pos = NULL;
|
||||
|
||||
mutex_lock(&thermal_list_lock);
|
||||
|
||||
list_for_each_entry(pos, &thermal_tz_list, node) {
|
||||
if (!pos->tzp && !pos->ops->bind)
|
||||
continue;
|
||||
|
||||
if (!pos->tzp && pos->ops->bind) {
|
||||
ret = pos->ops->bind(pos, cdev);
|
||||
if (ret)
|
||||
print_bind_err_msg(pos, cdev, ret);
|
||||
}
|
||||
|
||||
tzp = pos->tzp;
|
||||
if (!tzp || !tzp->tbp)
|
||||
continue;
|
||||
|
||||
for (i = 0; i < tzp->num_tbps; i++) {
|
||||
if (tzp->tbp[i].cdev || !tzp->tbp[i].match)
|
||||
continue;
|
||||
if (tzp->tbp[i].match(pos, cdev))
|
||||
continue;
|
||||
tzp->tbp[i].cdev = cdev;
|
||||
__bind(pos, tzp->tbp[i].trip_mask, cdev);
|
||||
}
|
||||
}
|
||||
|
||||
mutex_unlock(&thermal_list_lock);
|
||||
}
|
||||
|
||||
static void bind_tz(struct thermal_zone_device *tz)
|
||||
{
|
||||
int i, ret;
|
||||
struct thermal_cooling_device *pos = NULL;
|
||||
const struct thermal_zone_params *tzp = tz->tzp;
|
||||
|
||||
if (!tzp && !tz->ops->bind)
|
||||
return;
|
||||
|
||||
mutex_lock(&thermal_list_lock);
|
||||
|
||||
/* If there is no platform data, try to use ops->bind */
|
||||
if (!tzp && tz->ops->bind) {
|
||||
list_for_each_entry(pos, &thermal_cdev_list, node) {
|
||||
ret = tz->ops->bind(tz, pos);
|
||||
if (ret)
|
||||
print_bind_err_msg(tz, pos, ret);
|
||||
}
|
||||
goto exit;
|
||||
}
|
||||
|
||||
if (!tzp || !tzp->tbp)
|
||||
goto exit;
|
||||
|
||||
list_for_each_entry(pos, &thermal_cdev_list, node) {
|
||||
for (i = 0; i < tzp->num_tbps; i++) {
|
||||
if (tzp->tbp[i].cdev || !tzp->tbp[i].match)
|
||||
continue;
|
||||
if (tzp->tbp[i].match(tz, pos))
|
||||
continue;
|
||||
tzp->tbp[i].cdev = pos;
|
||||
__bind(tz, tzp->tbp[i].trip_mask, pos);
|
||||
}
|
||||
}
|
||||
exit:
|
||||
mutex_unlock(&thermal_list_lock);
|
||||
}
|
||||
|
||||
static void thermal_zone_device_set_polling(struct thermal_zone_device *tz,
|
||||
int delay)
|
||||
{
|
||||
if (delay > 1000)
|
||||
mod_delayed_work(system_freezable_wq, &tz->poll_queue,
|
||||
round_jiffies(msecs_to_jiffies(delay)));
|
||||
else if (delay)
|
||||
mod_delayed_work(system_freezable_wq, &tz->poll_queue,
|
||||
msecs_to_jiffies(delay));
|
||||
else
|
||||
cancel_delayed_work(&tz->poll_queue);
|
||||
}
|
||||
|
||||
static void monitor_thermal_zone(struct thermal_zone_device *tz)
|
||||
{
|
||||
mutex_lock(&tz->lock);
|
||||
|
||||
if (tz->passive)
|
||||
thermal_zone_device_set_polling(tz, tz->passive_delay);
|
||||
else if (tz->polling_delay)
|
||||
thermal_zone_device_set_polling(tz, tz->polling_delay);
|
||||
else
|
||||
thermal_zone_device_set_polling(tz, 0);
|
||||
|
||||
mutex_unlock(&tz->lock);
|
||||
}
|
||||
|
||||
static void handle_non_critical_trips(struct thermal_zone_device *tz,
|
||||
int trip, enum thermal_trip_type trip_type)
|
||||
{
|
||||
if (tz->governor)
|
||||
tz->governor->throttle(tz, trip);
|
||||
}
|
||||
|
||||
static void handle_critical_trips(struct thermal_zone_device *tz,
|
||||
int trip, enum thermal_trip_type trip_type)
|
||||
{
|
||||
long trip_temp;
|
||||
|
||||
tz->ops->get_trip_temp(tz, trip, &trip_temp);
|
||||
|
||||
/* If we have not crossed the trip_temp, we do not care. */
|
||||
if (tz->temperature < trip_temp)
|
||||
return;
|
||||
|
||||
if (tz->ops->notify)
|
||||
tz->ops->notify(tz, trip, trip_type);
|
||||
|
||||
if (trip_type == THERMAL_TRIP_CRITICAL) {
|
||||
pr_emerg("Critical temperature reached(%d C),shutting down\n",
|
||||
tz->temperature / 1000);
|
||||
orderly_poweroff(true);
|
||||
}
|
||||
}
|
||||
|
||||
static void handle_thermal_trip(struct thermal_zone_device *tz, int trip)
|
||||
{
|
||||
enum thermal_trip_type type;
|
||||
|
||||
tz->ops->get_trip_type(tz, trip, &type);
|
||||
|
||||
if (type == THERMAL_TRIP_CRITICAL || type == THERMAL_TRIP_HOT)
|
||||
handle_critical_trips(tz, trip, type);
|
||||
else
|
||||
handle_non_critical_trips(tz, trip, type);
|
||||
/*
|
||||
* Alright, we handled this trip successfully.
|
||||
* So, start monitoring again.
|
||||
*/
|
||||
monitor_thermal_zone(tz);
|
||||
}
|
||||
|
||||
static void update_temperature(struct thermal_zone_device *tz)
|
||||
{
|
||||
long temp;
|
||||
int ret;
|
||||
|
||||
mutex_lock(&tz->lock);
|
||||
|
||||
ret = tz->ops->get_temp(tz, &temp);
|
||||
if (ret) {
|
||||
pr_warn("failed to read out thermal zone %d\n", tz->id);
|
||||
goto exit;
|
||||
}
|
||||
|
||||
tz->last_temperature = tz->temperature;
|
||||
tz->temperature = temp;
|
||||
|
||||
exit:
|
||||
mutex_unlock(&tz->lock);
|
||||
}
|
||||
|
||||
void thermal_zone_device_update(struct thermal_zone_device *tz)
|
||||
{
|
||||
int count;
|
||||
|
||||
update_temperature(tz);
|
||||
|
||||
for (count = 0; count < tz->trips; count++)
|
||||
handle_thermal_trip(tz, count);
|
||||
}
|
||||
EXPORT_SYMBOL(thermal_zone_device_update);
|
||||
|
||||
static void thermal_zone_device_check(struct work_struct *work)
|
||||
{
|
||||
struct thermal_zone_device *tz = container_of(work, struct
|
||||
thermal_zone_device,
|
||||
poll_queue.work);
|
||||
thermal_zone_device_update(tz);
|
||||
}
|
||||
|
||||
/* sys I/F for thermal zone */
|
||||
|
||||
#define to_thermal_zone(_dev) \
|
||||
@ -354,10 +670,41 @@ passive_show(struct device *dev, struct device_attribute *attr,
|
||||
return sprintf(buf, "%d\n", tz->forced_passive);
|
||||
}
|
||||
|
||||
static ssize_t
|
||||
policy_store(struct device *dev, struct device_attribute *attr,
|
||||
const char *buf, size_t count)
|
||||
{
|
||||
int ret = -EINVAL;
|
||||
struct thermal_zone_device *tz = to_thermal_zone(dev);
|
||||
struct thermal_governor *gov;
|
||||
|
||||
mutex_lock(&thermal_governor_lock);
|
||||
|
||||
gov = __find_governor(buf);
|
||||
if (!gov)
|
||||
goto exit;
|
||||
|
||||
tz->governor = gov;
|
||||
ret = count;
|
||||
|
||||
exit:
|
||||
mutex_unlock(&thermal_governor_lock);
|
||||
return ret;
|
||||
}
|
||||
|
||||
static ssize_t
|
||||
policy_show(struct device *dev, struct device_attribute *devattr, char *buf)
|
||||
{
|
||||
struct thermal_zone_device *tz = to_thermal_zone(dev);
|
||||
|
||||
return sprintf(buf, "%s\n", tz->governor->name);
|
||||
}
|
||||
|
||||
static DEVICE_ATTR(type, 0444, type_show, NULL);
|
||||
static DEVICE_ATTR(temp, 0444, temp_show, NULL);
|
||||
static DEVICE_ATTR(mode, 0644, mode_show, mode_store);
|
||||
static DEVICE_ATTR(passive, S_IRUGO | S_IWUSR, passive_show, passive_store);
|
||||
static DEVICE_ATTR(policy, S_IRUGO | S_IWUSR, policy_show, policy_store);
|
||||
|
||||
/* sys I/F for cooling device */
|
||||
#define to_cooling_device(_dev) \
|
||||
@ -700,27 +1047,6 @@ thermal_remove_hwmon_sysfs(struct thermal_zone_device *tz)
|
||||
}
|
||||
#endif
|
||||
|
||||
static void thermal_zone_device_set_polling(struct thermal_zone_device *tz,
|
||||
int delay)
|
||||
{
|
||||
if (delay > 1000)
|
||||
mod_delayed_work(system_freezable_wq, &tz->poll_queue,
|
||||
round_jiffies(msecs_to_jiffies(delay)));
|
||||
else if (delay)
|
||||
mod_delayed_work(system_freezable_wq, &tz->poll_queue,
|
||||
msecs_to_jiffies(delay));
|
||||
else
|
||||
cancel_delayed_work(&tz->poll_queue);
|
||||
}
|
||||
|
||||
static void thermal_zone_device_check(struct work_struct *work)
|
||||
{
|
||||
struct thermal_zone_device *tz = container_of(work, struct
|
||||
thermal_zone_device,
|
||||
poll_queue.work);
|
||||
thermal_zone_device_update(tz);
|
||||
}
|
||||
|
||||
/**
|
||||
* thermal_zone_bind_cooling_device - bind a cooling device to a thermal zone
|
||||
* @tz: thermal zone device
|
||||
@ -895,7 +1221,6 @@ thermal_cooling_device_register(char *type, void *devdata,
|
||||
const struct thermal_cooling_device_ops *ops)
|
||||
{
|
||||
struct thermal_cooling_device *cdev;
|
||||
struct thermal_zone_device *pos;
|
||||
int result;
|
||||
|
||||
if (type && strlen(type) >= THERMAL_NAME_LENGTH)
|
||||
@ -945,20 +1270,15 @@ thermal_cooling_device_register(char *type, void *devdata,
|
||||
if (result)
|
||||
goto unregister;
|
||||
|
||||
/* Add 'this' new cdev to the global cdev list */
|
||||
mutex_lock(&thermal_list_lock);
|
||||
list_add(&cdev->node, &thermal_cdev_list);
|
||||
list_for_each_entry(pos, &thermal_tz_list, node) {
|
||||
if (!pos->ops->bind)
|
||||
continue;
|
||||
result = pos->ops->bind(pos, cdev);
|
||||
if (result)
|
||||
break;
|
||||
|
||||
}
|
||||
mutex_unlock(&thermal_list_lock);
|
||||
|
||||
if (!result)
|
||||
return cdev;
|
||||
/* Update binding information for 'this' new cdev */
|
||||
bind_cdev(cdev);
|
||||
|
||||
return cdev;
|
||||
|
||||
unregister:
|
||||
release_idr(&thermal_cdev_idr, &thermal_idr_lock, cdev->id);
|
||||
@ -974,10 +1294,10 @@ EXPORT_SYMBOL(thermal_cooling_device_register);
|
||||
* thermal_cooling_device_unregister() must be called when the device is no
|
||||
* longer needed.
|
||||
*/
|
||||
void thermal_cooling_device_unregister(struct
|
||||
thermal_cooling_device
|
||||
*cdev)
|
||||
void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
|
||||
{
|
||||
int i;
|
||||
const struct thermal_zone_params *tzp;
|
||||
struct thermal_zone_device *tz;
|
||||
struct thermal_cooling_device *pos = NULL;
|
||||
|
||||
@ -994,12 +1314,28 @@ void thermal_cooling_device_unregister(struct
|
||||
return;
|
||||
}
|
||||
list_del(&cdev->node);
|
||||
|
||||
/* Unbind all thermal zones associated with 'this' cdev */
|
||||
list_for_each_entry(tz, &thermal_tz_list, node) {
|
||||
if (!tz->ops->unbind)
|
||||
if (tz->ops->unbind) {
|
||||
tz->ops->unbind(tz, cdev);
|
||||
continue;
|
||||
tz->ops->unbind(tz, cdev);
|
||||
}
|
||||
|
||||
if (!tz->tzp || !tz->tzp->tbp)
|
||||
continue;
|
||||
|
||||
tzp = tz->tzp;
|
||||
for (i = 0; i < tzp->num_tbps; i++) {
|
||||
if (tzp->tbp[i].cdev == cdev) {
|
||||
__unbind(tz, tzp->tbp[i].trip_mask, cdev);
|
||||
tzp->tbp[i].cdev = NULL;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
mutex_unlock(&thermal_list_lock);
|
||||
|
||||
if (cdev->type[0])
|
||||
device_remove_file(&cdev->device, &dev_attr_cdev_type);
|
||||
device_remove_file(&cdev->device, &dev_attr_max_state);
|
||||
@ -1011,7 +1347,7 @@ void thermal_cooling_device_unregister(struct
|
||||
}
|
||||
EXPORT_SYMBOL(thermal_cooling_device_unregister);
|
||||
|
||||
static void thermal_cdev_do_update(struct thermal_cooling_device *cdev)
|
||||
void thermal_cdev_update(struct thermal_cooling_device *cdev)
|
||||
{
|
||||
struct thermal_instance *instance;
|
||||
unsigned long target = 0;
|
||||
@ -1032,183 +1368,25 @@ static void thermal_cdev_do_update(struct thermal_cooling_device *cdev)
|
||||
cdev->ops->set_cur_state(cdev, target);
|
||||
cdev->updated = true;
|
||||
}
|
||||
EXPORT_SYMBOL(thermal_cdev_update);
|
||||
|
||||
static void thermal_zone_do_update(struct thermal_zone_device *tz)
|
||||
{
|
||||
struct thermal_instance *instance;
|
||||
|
||||
list_for_each_entry(instance, &tz->thermal_instances, tz_node)
|
||||
thermal_cdev_do_update(instance->cdev);
|
||||
}
|
||||
|
||||
/*
|
||||
* Cooling algorithm for both active and passive cooling
|
||||
*
|
||||
* 1. if the temperature is higher than a trip point,
|
||||
* a. if the trend is THERMAL_TREND_RAISING, use higher cooling
|
||||
* state for this trip point
|
||||
* b. if the trend is THERMAL_TREND_DROPPING, use lower cooling
|
||||
* state for this trip point
|
||||
*
|
||||
* 2. if the temperature is lower than a trip point, use lower
|
||||
* cooling state for this trip point
|
||||
*
|
||||
* Note that this behaves the same as the previous passive cooling
|
||||
* algorithm.
|
||||
*/
|
||||
|
||||
static void thermal_zone_trip_update(struct thermal_zone_device *tz,
|
||||
int trip, long temp)
|
||||
{
|
||||
struct thermal_instance *instance;
|
||||
struct thermal_cooling_device *cdev = NULL;
|
||||
unsigned long cur_state, max_state;
|
||||
long trip_temp;
|
||||
enum thermal_trip_type trip_type;
|
||||
enum thermal_trend trend;
|
||||
|
||||
if (trip == THERMAL_TRIPS_NONE) {
|
||||
trip_temp = tz->forced_passive;
|
||||
trip_type = THERMAL_TRIPS_NONE;
|
||||
} else {
|
||||
tz->ops->get_trip_temp(tz, trip, &trip_temp);
|
||||
tz->ops->get_trip_type(tz, trip, &trip_type);
|
||||
}
|
||||
|
||||
if (!tz->ops->get_trend || tz->ops->get_trend(tz, trip, &trend)) {
|
||||
/*
|
||||
* compare the current temperature and previous temperature
|
||||
* to get the thermal trend, if no special requirement
|
||||
*/
|
||||
if (tz->temperature > tz->last_temperature)
|
||||
trend = THERMAL_TREND_RAISING;
|
||||
else if (tz->temperature < tz->last_temperature)
|
||||
trend = THERMAL_TREND_DROPPING;
|
||||
else
|
||||
trend = THERMAL_TREND_STABLE;
|
||||
}
|
||||
|
||||
if (temp >= trip_temp) {
|
||||
list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
|
||||
if (instance->trip != trip)
|
||||
continue;
|
||||
|
||||
cdev = instance->cdev;
|
||||
|
||||
cdev->ops->get_cur_state(cdev, &cur_state);
|
||||
cdev->ops->get_max_state(cdev, &max_state);
|
||||
|
||||
if (trend == THERMAL_TREND_RAISING) {
|
||||
cur_state = cur_state < instance->upper ?
|
||||
(cur_state + 1) : instance->upper;
|
||||
} else if (trend == THERMAL_TREND_DROPPING) {
|
||||
cur_state = cur_state > instance->lower ?
|
||||
(cur_state - 1) : instance->lower;
|
||||
}
|
||||
|
||||
/* activate a passive thermal instance */
|
||||
if ((trip_type == THERMAL_TRIP_PASSIVE ||
|
||||
trip_type == THERMAL_TRIPS_NONE) &&
|
||||
instance->target == THERMAL_NO_TARGET)
|
||||
tz->passive++;
|
||||
|
||||
instance->target = cur_state;
|
||||
cdev->updated = false; /* cooling device needs update */
|
||||
}
|
||||
} else { /* below trip */
|
||||
list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
|
||||
if (instance->trip != trip)
|
||||
continue;
|
||||
|
||||
/* Do not use the inactive thermal instance */
|
||||
if (instance->target == THERMAL_NO_TARGET)
|
||||
continue;
|
||||
cdev = instance->cdev;
|
||||
cdev->ops->get_cur_state(cdev, &cur_state);
|
||||
|
||||
cur_state = cur_state > instance->lower ?
|
||||
(cur_state - 1) : THERMAL_NO_TARGET;
|
||||
|
||||
/* deactivate a passive thermal instance */
|
||||
if ((trip_type == THERMAL_TRIP_PASSIVE ||
|
||||
trip_type == THERMAL_TRIPS_NONE) &&
|
||||
cur_state == THERMAL_NO_TARGET)
|
||||
tz->passive--;
|
||||
instance->target = cur_state;
|
||||
cdev->updated = false; /* cooling device needs update */
|
||||
}
|
||||
}
|
||||
|
||||
return;
|
||||
}
|
||||
/**
|
||||
* thermal_zone_device_update - force an update of a thermal zone's state
|
||||
* @ttz: the thermal zone to update
|
||||
* notify_thermal_framework - Sensor drivers use this API to notify framework
|
||||
* @tz: thermal zone device
|
||||
* @trip: indicates which trip point has been crossed
|
||||
*
|
||||
* This function handles the trip events from sensor drivers. It starts
|
||||
* throttling the cooling devices according to the policy configured.
|
||||
* For CRITICAL and HOT trip points, this notifies the respective drivers,
|
||||
* and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
|
||||
* The throttling policy is based on the configured platform data; if no
|
||||
* platform data is provided, this uses the step_wise throttling policy.
|
||||
*/
|
||||
|
||||
void thermal_zone_device_update(struct thermal_zone_device *tz)
|
||||
void notify_thermal_framework(struct thermal_zone_device *tz, int trip)
|
||||
{
|
||||
int count, ret = 0;
|
||||
long temp, trip_temp;
|
||||
enum thermal_trip_type trip_type;
|
||||
|
||||
mutex_lock(&tz->lock);
|
||||
|
||||
if (tz->ops->get_temp(tz, &temp)) {
|
||||
/* get_temp failed - retry it later */
|
||||
pr_warn("failed to read out thermal zone %d\n", tz->id);
|
||||
goto leave;
|
||||
}
|
||||
|
||||
tz->last_temperature = tz->temperature;
|
||||
tz->temperature = temp;
|
||||
|
||||
for (count = 0; count < tz->trips; count++) {
|
||||
tz->ops->get_trip_type(tz, count, &trip_type);
|
||||
tz->ops->get_trip_temp(tz, count, &trip_temp);
|
||||
|
||||
switch (trip_type) {
|
||||
case THERMAL_TRIP_CRITICAL:
|
||||
if (temp >= trip_temp) {
|
||||
if (tz->ops->notify)
|
||||
ret = tz->ops->notify(tz, count,
|
||||
trip_type);
|
||||
if (!ret) {
|
||||
pr_emerg("Critical temperature reached (%ld C), shutting down\n",
|
||||
temp/1000);
|
||||
orderly_poweroff(true);
|
||||
}
|
||||
}
|
||||
break;
|
||||
case THERMAL_TRIP_HOT:
|
||||
if (temp >= trip_temp)
|
||||
if (tz->ops->notify)
|
||||
tz->ops->notify(tz, count, trip_type);
|
||||
break;
|
||||
case THERMAL_TRIP_ACTIVE:
|
||||
thermal_zone_trip_update(tz, count, temp);
|
||||
break;
|
||||
case THERMAL_TRIP_PASSIVE:
|
||||
if (temp >= trip_temp || tz->passive)
|
||||
thermal_zone_trip_update(tz, count, temp);
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
if (tz->forced_passive)
|
||||
thermal_zone_trip_update(tz, THERMAL_TRIPS_NONE, temp);
|
||||
thermal_zone_do_update(tz);
|
||||
|
||||
leave:
|
||||
if (tz->passive)
|
||||
thermal_zone_device_set_polling(tz, tz->passive_delay);
|
||||
else if (tz->polling_delay)
|
||||
thermal_zone_device_set_polling(tz, tz->polling_delay);
|
||||
else
|
||||
thermal_zone_device_set_polling(tz, 0);
|
||||
mutex_unlock(&tz->lock);
|
||||
handle_thermal_trip(tz, trip);
|
||||
}
|
||||
EXPORT_SYMBOL(thermal_zone_device_update);
|
||||
EXPORT_SYMBOL(notify_thermal_framework);
|
||||
|
||||
/**
|
||||
* create_trip_attrs - create attributes for trip points
|
||||
@ -1320,6 +1498,7 @@ static void remove_trip_attrs(struct thermal_zone_device *tz)
|
||||
* @mask: a bit string indicating the writeablility of trip points
|
||||
* @devdata: private device data
|
||||
* @ops: standard thermal zone device callbacks
|
||||
* @tzp: thermal zone platform parameters
|
||||
* @passive_delay: number of milliseconds to wait between polls when
|
||||
* performing passive cooling
|
||||
* @polling_delay: number of milliseconds to wait between polls when checking
|
||||
@ -1332,10 +1511,10 @@ static void remove_trip_attrs(struct thermal_zone_device *tz)
|
||||
struct thermal_zone_device *thermal_zone_device_register(const char *type,
|
||||
int trips, int mask, void *devdata,
|
||||
const struct thermal_zone_device_ops *ops,
|
||||
const struct thermal_zone_params *tzp,
|
||||
int passive_delay, int polling_delay)
|
||||
{
|
||||
struct thermal_zone_device *tz;
|
||||
struct thermal_cooling_device *pos;
|
||||
enum thermal_trip_type trip_type;
|
||||
int result;
|
||||
int count;
|
||||
@ -1365,6 +1544,7 @@ struct thermal_zone_device *thermal_zone_device_register(const char *type,
|
||||
|
||||
strcpy(tz->type, type ? : "");
|
||||
tz->ops = ops;
|
||||
tz->tzp = tzp;
|
||||
tz->device.class = &thermal_class;
|
||||
tz->devdata = devdata;
|
||||
tz->trips = trips;
|
||||
@ -1406,27 +1586,38 @@ struct thermal_zone_device *thermal_zone_device_register(const char *type,
|
||||
passive = 1;
|
||||
}
|
||||
|
||||
if (!passive)
|
||||
result = device_create_file(&tz->device,
|
||||
&dev_attr_passive);
|
||||
if (!passive) {
|
||||
result = device_create_file(&tz->device, &dev_attr_passive);
|
||||
if (result)
|
||||
goto unregister;
|
||||
}
|
||||
|
||||
/* Create policy attribute */
|
||||
result = device_create_file(&tz->device, &dev_attr_policy);
|
||||
if (result)
|
||||
goto unregister;
|
||||
|
||||
/* Update 'this' zone's governor information */
|
||||
mutex_lock(&thermal_governor_lock);
|
||||
|
||||
if (tz->tzp)
|
||||
tz->governor = __find_governor(tz->tzp->governor_name);
|
||||
else
|
||||
tz->governor = __find_governor(DEFAULT_THERMAL_GOVERNOR);
|
||||
|
||||
mutex_unlock(&thermal_governor_lock);
|
||||
|
||||
result = thermal_add_hwmon_sysfs(tz);
|
||||
if (result)
|
||||
goto unregister;
|
||||
|
||||
mutex_lock(&thermal_list_lock);
|
||||
list_add_tail(&tz->node, &thermal_tz_list);
|
||||
if (ops->bind)
|
||||
list_for_each_entry(pos, &thermal_cdev_list, node) {
|
||||
result = ops->bind(tz, pos);
|
||||
if (result)
|
||||
break;
|
||||
}
|
||||
mutex_unlock(&thermal_list_lock);
|
||||
|
||||
/* Bind cooling devices for this zone */
|
||||
bind_tz(tz);
|
||||
|
||||
INIT_DELAYED_WORK(&(tz->poll_queue), thermal_zone_device_check);
|
||||
|
||||
thermal_zone_device_update(tz);
|
||||
@ -1447,12 +1638,16 @@ EXPORT_SYMBOL(thermal_zone_device_register);
|
||||
*/
|
||||
void thermal_zone_device_unregister(struct thermal_zone_device *tz)
|
||||
{
|
||||
int i;
|
||||
const struct thermal_zone_params *tzp;
|
||||
struct thermal_cooling_device *cdev;
|
||||
struct thermal_zone_device *pos = NULL;
|
||||
|
||||
if (!tz)
|
||||
return;
|
||||
|
||||
tzp = tz->tzp;
|
||||
|
||||
mutex_lock(&thermal_list_lock);
|
||||
list_for_each_entry(pos, &thermal_tz_list, node)
|
||||
if (pos == tz)
|
||||
@ -1463,9 +1658,25 @@ void thermal_zone_device_unregister(struct thermal_zone_device *tz)
|
||||
return;
|
||||
}
|
||||
list_del(&tz->node);
|
||||
if (tz->ops->unbind)
|
||||
list_for_each_entry(cdev, &thermal_cdev_list, node)
|
||||
tz->ops->unbind(tz, cdev);
|
||||
|
||||
/* Unbind all cdevs associated with 'this' thermal zone */
|
||||
list_for_each_entry(cdev, &thermal_cdev_list, node) {
|
||||
if (tz->ops->unbind) {
|
||||
tz->ops->unbind(tz, cdev);
|
||||
continue;
|
||||
}
|
||||
|
||||
if (!tzp || !tzp->tbp)
|
||||
break;
|
||||
|
||||
for (i = 0; i < tzp->num_tbps; i++) {
|
||||
if (tzp->tbp[i].cdev == cdev) {
|
||||
__unbind(tz, tzp->tbp[i].trip_mask, cdev);
|
||||
tzp->tbp[i].cdev = NULL;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
mutex_unlock(&thermal_list_lock);
|
||||
|
||||
thermal_zone_device_set_polling(tz, 0);
|
||||
@ -1475,7 +1686,9 @@ void thermal_zone_device_unregister(struct thermal_zone_device *tz)
|
||||
device_remove_file(&tz->device, &dev_attr_temp);
|
||||
if (tz->ops->get_mode)
|
||||
device_remove_file(&tz->device, &dev_attr_mode);
|
||||
device_remove_file(&tz->device, &dev_attr_policy);
|
||||
remove_trip_attrs(tz);
|
||||
tz->governor = NULL;
|
||||
|
||||
thermal_remove_hwmon_sysfs(tz);
|
||||
release_idr(&thermal_tz_idr, &thermal_idr_lock, tz->id);
|
||||
|
68
drivers/thermal/user_space.c
Normal file
68
drivers/thermal/user_space.c
Normal file
@ -0,0 +1,68 @@
|
||||
/*
|
||||
* user_space.c - A simple user space Thermal events notifier
|
||||
*
|
||||
* Copyright (C) 2012 Intel Corp
|
||||
* Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com>
|
||||
*
|
||||
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License as published by
|
||||
* the Free Software Foundation; version 2 of the License.
|
||||
*
|
||||
* This program is distributed in the hope that it will be useful, but
|
||||
* WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
||||
* General Public License for more details.
|
||||
*
|
||||
* You should have received a copy of the GNU General Public License along
|
||||
* with this program; if not, write to the Free Software Foundation, Inc.,
|
||||
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
|
||||
*
|
||||
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
*/
|
||||
|
||||
#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
|
||||
|
||||
#include <linux/module.h>
|
||||
#include <linux/thermal.h>
|
||||
|
||||
#include "thermal_core.h"
|
||||
|
||||
/**
|
||||
* notify_user_space - Notifies user space about thermal events
|
||||
* @tz - thermal_zone_device
|
||||
*
|
||||
* This function notifies the user space through UEvents.
|
||||
*/
|
||||
static int notify_user_space(struct thermal_zone_device *tz, int trip)
|
||||
{
|
||||
mutex_lock(&tz->lock);
|
||||
kobject_uevent(&tz->device.kobj, KOBJ_CHANGE);
|
||||
mutex_unlock(&tz->lock);
|
||||
return 0;
|
||||
}
|
||||
|
||||
static struct thermal_governor thermal_gov_user_space = {
|
||||
.name = "user_space",
|
||||
.throttle = notify_user_space,
|
||||
.owner = THIS_MODULE,
|
||||
};
|
||||
|
||||
static int __init thermal_gov_user_space_init(void)
|
||||
{
|
||||
return thermal_register_governor(&thermal_gov_user_space);
|
||||
}
|
||||
|
||||
static void __exit thermal_gov_user_space_exit(void)
|
||||
{
|
||||
thermal_unregister_governor(&thermal_gov_user_space);
|
||||
}
|
||||
|
||||
/* This should load after thermal framework */
|
||||
fs_initcall(thermal_gov_user_space_init);
|
||||
module_exit(thermal_gov_user_space_exit);
|
||||
|
||||
MODULE_AUTHOR("Durgadoss R");
|
||||
MODULE_DESCRIPTION("A user space Thermal notifier");
|
||||
MODULE_LICENSE("GPL");
|
@ -29,13 +29,13 @@
|
||||
#define CPUFREQ_COOLING_START 0
|
||||
#define CPUFREQ_COOLING_STOP 1
|
||||
|
||||
#ifdef CONFIG_CPU_THERMAL
|
||||
#if defined(CONFIG_CPU_THERMAL) || defined(CONFIG_CPU_THERMAL_MODULE)
|
||||
/**
|
||||
* cpufreq_cooling_register - function to create cpufreq cooling device.
|
||||
* @clip_cpus: cpumask of cpus where the frequency constraints will happen
|
||||
*/
|
||||
struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
struct cpumask *clip_cpus);
|
||||
const struct cpumask *clip_cpus);
|
||||
|
||||
/**
|
||||
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
|
||||
@ -44,7 +44,7 @@ struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
|
||||
#else /* !CONFIG_CPU_THERMAL */
|
||||
static inline struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
struct cpumask *clip_cpus)
|
||||
const struct cpumask *clip_cpus)
|
||||
{
|
||||
return NULL;
|
||||
}
|
||||
|
38
include/linux/platform_data/db8500_thermal.h
Normal file
38
include/linux/platform_data/db8500_thermal.h
Normal file
@ -0,0 +1,38 @@
|
||||
/*
|
||||
* db8500_thermal.h - DB8500 Thermal Management Implementation
|
||||
*
|
||||
* Copyright (C) 2012 ST-Ericsson
|
||||
* Copyright (C) 2012 Linaro Ltd.
|
||||
*
|
||||
* Author: Hongbo Zhang <hongbo.zhang@linaro.com>
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License as published by
|
||||
* the Free Software Foundation; either version 2 of the License, or
|
||||
* (at your option) any later version.
|
||||
*
|
||||
* This program is distributed in the hope that it will be useful,
|
||||
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||||
* GNU General Public License for more details.
|
||||
*/
|
||||
|
||||
#ifndef _DB8500_THERMAL_H_
|
||||
#define _DB8500_THERMAL_H_
|
||||
|
||||
#include <linux/thermal.h>
|
||||
|
||||
#define COOLING_DEV_MAX 8
|
||||
|
||||
struct db8500_trip_point {
|
||||
unsigned long temp;
|
||||
enum thermal_trip_type type;
|
||||
char cdev_name[COOLING_DEV_MAX][THERMAL_NAME_LENGTH];
|
||||
};
|
||||
|
||||
struct db8500_thsens_platform_data {
|
||||
struct db8500_trip_point trip_points[THERMAL_MAX_TRIPS];
|
||||
int num_trips;
|
||||
};
|
||||
|
||||
#endif /* _DB8500_THERMAL_H_ */
|
@ -29,6 +29,32 @@
|
||||
#include <linux/device.h>
|
||||
#include <linux/workqueue.h>
|
||||
|
||||
#define THERMAL_TRIPS_NONE -1
|
||||
#define THERMAL_MAX_TRIPS 12
|
||||
#define THERMAL_NAME_LENGTH 20
|
||||
|
||||
/* No upper/lower limit requirement */
|
||||
#define THERMAL_NO_LIMIT -1UL
|
||||
|
||||
/* Unit conversion macros */
|
||||
#define KELVIN_TO_CELSIUS(t) (long)(((long)t-2732 >= 0) ? \
|
||||
((long)t-2732+5)/10 : ((long)t-2732-5)/10)
|
||||
#define CELSIUS_TO_KELVIN(t) ((t)*10+2732)
|
||||
|
||||
/* Adding event notification support elements */
|
||||
#define THERMAL_GENL_FAMILY_NAME "thermal_event"
|
||||
#define THERMAL_GENL_VERSION 0x01
|
||||
#define THERMAL_GENL_MCAST_GROUP_NAME "thermal_mc_group"
|
||||
|
||||
/* Default Thermal Governor */
|
||||
#if defined(CONFIG_THERMAL_DEFAULT_GOV_STEP_WISE)
|
||||
#define DEFAULT_THERMAL_GOVERNOR "step_wise"
|
||||
#elif defined(CONFIG_THERMAL_DEFAULT_GOV_FAIR_SHARE)
|
||||
#define DEFAULT_THERMAL_GOVERNOR "fair_share"
|
||||
#elif defined(CONFIG_THERMAL_DEFAULT_GOV_USER_SPACE)
|
||||
#define DEFAULT_THERMAL_GOVERNOR "user_space"
|
||||
#endif
|
||||
|
||||
struct thermal_zone_device;
|
||||
struct thermal_cooling_device;
|
||||
|
||||
@ -50,6 +76,30 @@ enum thermal_trend {
|
||||
THERMAL_TREND_DROPPING, /* temperature is dropping */
|
||||
};
|
||||
|
||||
/* Events supported by Thermal Netlink */
|
||||
enum events {
|
||||
THERMAL_AUX0,
|
||||
THERMAL_AUX1,
|
||||
THERMAL_CRITICAL,
|
||||
THERMAL_DEV_FAULT,
|
||||
};
|
||||
|
||||
/* attributes of thermal_genl_family */
|
||||
enum {
|
||||
THERMAL_GENL_ATTR_UNSPEC,
|
||||
THERMAL_GENL_ATTR_EVENT,
|
||||
__THERMAL_GENL_ATTR_MAX,
|
||||
};
|
||||
#define THERMAL_GENL_ATTR_MAX (__THERMAL_GENL_ATTR_MAX - 1)
|
||||
|
||||
/* commands supported by the thermal_genl_family */
|
||||
enum {
|
||||
THERMAL_GENL_CMD_UNSPEC,
|
||||
THERMAL_GENL_CMD_EVENT,
|
||||
__THERMAL_GENL_CMD_MAX,
|
||||
};
|
||||
#define THERMAL_GENL_CMD_MAX (__THERMAL_GENL_CMD_MAX - 1)
|
||||
|
||||
struct thermal_zone_device_ops {
|
||||
int (*bind) (struct thermal_zone_device *,
|
||||
struct thermal_cooling_device *);
|
||||
@ -83,11 +133,6 @@ struct thermal_cooling_device_ops {
|
||||
int (*set_cur_state) (struct thermal_cooling_device *, unsigned long);
|
||||
};
|
||||
|
||||
#define THERMAL_NO_LIMIT -1UL /* no upper/lower limit requirement */
|
||||
|
||||
#define THERMAL_TRIPS_NONE -1
|
||||
#define THERMAL_MAX_TRIPS 12
|
||||
#define THERMAL_NAME_LENGTH 20
|
||||
struct thermal_cooling_device {
|
||||
int id;
|
||||
char type[THERMAL_NAME_LENGTH];
|
||||
@ -100,10 +145,6 @@ struct thermal_cooling_device {
|
||||
struct list_head node;
|
||||
};
|
||||
|
||||
#define KELVIN_TO_CELSIUS(t) (long)(((long)t-2732 >= 0) ? \
|
||||
((long)t-2732+5)/10 : ((long)t-2732-5)/10)
|
||||
#define CELSIUS_TO_KELVIN(t) ((t)*10+2732)
|
||||
|
||||
struct thermal_attr {
|
||||
struct device_attribute attr;
|
||||
char name[THERMAL_NAME_LENGTH];
|
||||
@ -125,46 +166,61 @@ struct thermal_zone_device {
|
||||
int passive;
|
||||
unsigned int forced_passive;
|
||||
const struct thermal_zone_device_ops *ops;
|
||||
const struct thermal_zone_params *tzp;
|
||||
struct thermal_governor *governor;
|
||||
struct list_head thermal_instances;
|
||||
struct idr idr;
|
||||
struct mutex lock; /* protect thermal_instances list */
|
||||
struct list_head node;
|
||||
struct delayed_work poll_queue;
|
||||
};
|
||||
/* Adding event notification support elements */
|
||||
#define THERMAL_GENL_FAMILY_NAME "thermal_event"
|
||||
#define THERMAL_GENL_VERSION 0x01
|
||||
#define THERMAL_GENL_MCAST_GROUP_NAME "thermal_mc_group"
|
||||
|
||||
enum events {
|
||||
THERMAL_AUX0,
|
||||
THERMAL_AUX1,
|
||||
THERMAL_CRITICAL,
|
||||
THERMAL_DEV_FAULT,
|
||||
/* Structure that holds thermal governor information */
|
||||
struct thermal_governor {
|
||||
char name[THERMAL_NAME_LENGTH];
|
||||
int (*throttle)(struct thermal_zone_device *tz, int trip);
|
||||
struct list_head governor_list;
|
||||
struct module *owner;
|
||||
};
|
||||
|
||||
/* Structure that holds binding parameters for a zone */
|
||||
struct thermal_bind_params {
|
||||
struct thermal_cooling_device *cdev;
|
||||
|
||||
/*
|
||||
* This is a measure of 'how effectively these devices can
|
||||
* cool 'this' thermal zone. The shall be determined by platform
|
||||
* characterization. This is on a 'percentage' scale.
|
||||
* See Documentation/thermal/sysfs-api.txt for more information.
|
||||
*/
|
||||
int weight;
|
||||
|
||||
/*
|
||||
* This is a bit mask that gives the binding relation between this
|
||||
* thermal zone and cdev, for a particular trip point.
|
||||
* See Documentation/thermal/sysfs-api.txt for more information.
|
||||
*/
|
||||
int trip_mask;
|
||||
int (*match) (struct thermal_zone_device *tz,
|
||||
struct thermal_cooling_device *cdev);
|
||||
};
|
||||
|
||||
/* Structure to define Thermal Zone parameters */
|
||||
struct thermal_zone_params {
|
||||
char governor_name[THERMAL_NAME_LENGTH];
|
||||
int num_tbps; /* Number of tbp entries */
|
||||
struct thermal_bind_params *tbp;
|
||||
};
|
||||
|
||||
struct thermal_genl_event {
|
||||
u32 orig;
|
||||
enum events event;
|
||||
};
|
||||
/* attributes of thermal_genl_family */
|
||||
enum {
|
||||
THERMAL_GENL_ATTR_UNSPEC,
|
||||
THERMAL_GENL_ATTR_EVENT,
|
||||
__THERMAL_GENL_ATTR_MAX,
|
||||
};
|
||||
#define THERMAL_GENL_ATTR_MAX (__THERMAL_GENL_ATTR_MAX - 1)
|
||||
|
||||
/* commands supported by the thermal_genl_family */
|
||||
enum {
|
||||
THERMAL_GENL_CMD_UNSPEC,
|
||||
THERMAL_GENL_CMD_EVENT,
|
||||
__THERMAL_GENL_CMD_MAX,
|
||||
};
|
||||
#define THERMAL_GENL_CMD_MAX (__THERMAL_GENL_CMD_MAX - 1)
|
||||
|
||||
/* Function declarations */
|
||||
struct thermal_zone_device *thermal_zone_device_register(const char *, int, int,
|
||||
void *, const struct thermal_zone_device_ops *, int, int);
|
||||
void *, const struct thermal_zone_device_ops *,
|
||||
const struct thermal_zone_params *, int, int);
|
||||
void thermal_zone_device_unregister(struct thermal_zone_device *);
|
||||
|
||||
int thermal_zone_bind_cooling_device(struct thermal_zone_device *, int,
|
||||
@ -173,10 +229,20 @@ int thermal_zone_bind_cooling_device(struct thermal_zone_device *, int,
|
||||
int thermal_zone_unbind_cooling_device(struct thermal_zone_device *, int,
|
||||
struct thermal_cooling_device *);
|
||||
void thermal_zone_device_update(struct thermal_zone_device *);
|
||||
|
||||
struct thermal_cooling_device *thermal_cooling_device_register(char *, void *,
|
||||
const struct thermal_cooling_device_ops *);
|
||||
void thermal_cooling_device_unregister(struct thermal_cooling_device *);
|
||||
|
||||
int get_tz_trend(struct thermal_zone_device *, int);
|
||||
struct thermal_instance *get_thermal_instance(struct thermal_zone_device *,
|
||||
struct thermal_cooling_device *, int);
|
||||
void thermal_cdev_update(struct thermal_cooling_device *);
|
||||
void notify_thermal_framework(struct thermal_zone_device *, int);
|
||||
|
||||
int thermal_register_governor(struct thermal_governor *);
|
||||
void thermal_unregister_governor(struct thermal_governor *);
|
||||
|
||||